Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Tooth Preparation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Managing congenitally missing lateral incisors. Part II: tooth-supported restorations.

Three treatment options exist for the replacement of congenitally missing lateral incisors: canine substitution, a tooth-supported restoration, or a single-tooth implant. Selecting the appropriate treatment option depends on the malocclusion, the anterior relationship, specific space requirements, and the condition of the adjacent teeth. The ideal treatment is the most conservative alternative that satisfies individual esthetic and functional requirements. This article closely examines the three options when replacing a missing lateral incisor with a tooth-supported restoration. These options are a resin-bonded fixed partial denture, a cantilevered fixed partial denture, and a conventional full-coverage fixed partial denture. The specific criteria that must be evaluated for each option is addressed to illustrate the importance of interdisciplinary treatment planning to achieve optimal esthetics and long-term predictability. This article is the second of a three-part series discussing the three treatment alternatives for replacing congenitally missing lateral incisors.

Anodontia↗

Biologic perspectives to support clinical choices in root canal treatment.

Some of the most keenly debated issues in endodontics have revolved around the where to end the root filling, as well as cleaning and shaping and obturation techniques. In some respects, original scientifically-based concepts have been abandoned in favour of clinical techniques that may provide aesthetically pleasing radiographs, but do not necessarily support tissue regeneration around the root apex following obturation. Recently advocated obturation techniques supporting the use of resin-based and bonded materials have not had the same extensive evaluation that gutta-percha, when in contact with the periradicular tissues, has had. Further studies are necessary so that evidence-based data can support the confident use of these innovative materials.

Extravasation of Diagnostic and Therapeutic Materi↗

Effect of Waterlase laser retrograde root-end cavity preparation on the integrity of root apices of extracted teeth as demonstrated by light microscopy.

Most endodontists use ultrasonic instruments for retrograde root-end cavity preparations even though they have been found to produce cracks. In this laboratory study, thirty-six randomly chosen roots had root-end cavity preparations made with the Waterlase laser and only one questionable intra-canal crack was found. It was concluded that the Waterlase laser when used to make endodontic root-end cavity preparations produces either no cracks, or a very low percentage (2.8%) of cracks.

Apicoectomy↗

Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters.

BACKGROUND: The aim of this ex vivo study was to evaluate the accuracy of four electronic apex locators (EALs) to determine the working length in teeth with various foramen diameters. Our previous study revealed that electronically measured canal length was influenced by the root canal diameter. It is not known whether foramen size would interfere with the reading accuracy of an EAL. METHODS: A total of 36 extracted human lower single rooted premolar teeth were divided into four groups of nine teeth each. In groups A, B and C, the root canals were instrumented using #10-80, #10-100 and #10-120 K-files, and the tip of size #80, #100 and #120 K-files were permitted to pass through the apical foramen to a length of 1mm, respectively. In group D, the teeth were instrumented using #10-140 K-files and the tip of #140 K-file was permitted to pass through the apical foramen to a length of 5 mm. Thus, the average apical foramen diameters in groups A, B, C and D were approximately 0.82 mm, 1.02 mm, 1.22mm and 1.5 mm, respectively. The teeth were then mounted in 1% agar and four EALs were used: Root ZX, Foramatron D10, Apex NRG and Apit 7. For electronic measurement, sizes #10 and #80, #10 and #100, #10 and #120, and #10 and #140 K-files were used for groups A, B, C and D, respectively. During electronic measurement the canals were flushed with 6% sodium hypochlorite solution. RESULTS: Three-way ANOVA and Bonferroni test showed that EAL, file size and foramen size all had a significant influence on the measurement error (P<0.0001), with all the interactions between these three factors being significant (P<0.0001). CONCLUSIONS: The four EALs were unreliable to determine the working length of teeth with a wide apical foramen, when using a small size file. The Root ZX and Foramatron D10 showed significantly better scores than the other two EALs and may be more reliable to determine the working length of teeth with a wide apical foramen, if a tight-fit file is used.

Bicuspid↗

Restitution of maxillary anterior aesthetics with all-ceramic components.

This paper discusses the use of four types of ceramics; zirconia, leucite reinforced glass, densely-sintered pure aluminium oxide and a low fusing porcelain, for the restitution of anterior aesthetics. Recent advances in dental ceramic technology have made this scenario a reality, which only a decade ago, was thought elusive. While ceramics offer obvious advantageous properties of enhanced appearance, they also need to satisfy functional and longevity criteria to be considered viable restorative materials. Numerous studies have cited data to fulfil these criteria, including sustained function and survival rates similar to porcelain fused to metal (PFM) restorations. This discussion will focus on current dental ceramic advances, and present a clinical case study using all ceramic constituents to rectify a deteriorating dentition.

Computer-Aided Design↗

Testing sealing properties of restorative materials against moist dentin.

The objectives of this investigation were (1) to develop a sensitive laboratory system that simulates the physiological and clinical conditions of a prepared human tooth in order to facilitate the determination of the bonding and sealing efficacies of restorative dental materials and (2) to conduct experiments with two dentin bonding agents, two posterior composite resin restorative materials (hybrid and microfilled), and a glass-ionomer type II filling material. The system functioned well and provided data to indicate that, after margination, the two posterior composite resin restorative materials performed equally and both performed better than the glass-ionomer filling material; none of the materials provided a perfect seal immediately after insertion, although some restorations demonstrated perfect seals from 16 hours to 28 days after placement; the seal of the glass-ionomer material improved after 28 days of storage in buffer solution; each successive step in the respective composite resin procedures improved the seal except in one case for the microfilled resin.

Composite Resins↗

Evaluation of endodontic files in digital radiographs before and after employing three image processing algorithms.

OBJECTIVES: Two digital image processing algorithms, one aimed at correction for exponential attenuation and one at correction for visual response, have been developed. The aims of the present study were to test whether digital radiographs processed with these algorithms improve determination of the length of endodontic files and whether such processed radiographs are comparable with the radiographs processed with a default image processing method employed by one commercially available digital intraoral system. METHODS: A dried human skull embedded in an acrylic compound was used for exposing radiographs of the upper and lower premolars and molars with endodontic files (Kerr files size 10 and size 15) positioned to the full length of the roots or 1.5 mm short of it. Radiographs were then processed in three sets. In one set, the radiographs were processed to compensate for exponential attenuation and the response of the human visual system. In the second, the radiographs were processed with the same compensation but with an additional shift in grey levels so that the output luminance in dentin at root tips corresponds to the mean of the luminance range of a computer monitor. In the third, the radiographs were processed with the default processing method in the Sidexis program. Ten viewers evaluated all radiographs. Receiver operating characteristic (ROC) curves were obtained and areas under the curves were calculated. RESULTS: For file size 10, ROC curves for processed radiographs were higher than that for originals, while for file size 15, ROC curves for processed and original radiographs were close to each other. Significant differences were found between processed and original radiographs regarding areas under ROC curves for file size 10 but not between the differently processed radiographs. For file size 15, no significant differences were found. CONCLUSION: Radiographs processed to correct for attenuation and visual response may improve determination of the length of thin endodontic files. Such processed radiographs are comparable with the radiographs processed with the default processing method in the Sidexis program.

Algorithms↗

[An evaluation of the biting force, the body composition and the amount of masticatory action in young females].

UNLABELLED: The purposes of this study were to investigate factors related to maximum biting force and to understand the characteristics of physical properties of daily ingested foods in young females. One hundred and forty subjects aged 18-23, with Angle 1 class occlusion, had not suffered from periodontitis, and had not been treated for preparation of tooth crown of first molars. Body height and weight were measured, and percentage of body fat, fat mass (FM) and lean body mass (LBM) were estimated, using the impedance analyzer. The maximum biting force was measured by the press sensation method. According to the formula on the basis of our new version of Yanagisawa's food classification, the mean value of the amount of masticatory action for one day was calculated. Subjects were divided into the normal biting force and the low biting force groups with -1SD of the maximum biting force, in order to compare body composition and backgrounds in sports activities between these two groups. Multiple linear regression analysis was carried out, employing maximum biting force (kg.f) as a dependent variable, and having a background in sports activities, FM, LBM, the number of missing teeth, the number of dental caries and the amount of masticatory action for one day as independent variables. Results were as in the following: 1) The proportion of subjects who had a background in sports activities in the low biting force group were less than that in the normal biting force group (p < 0.01). 2) Having a background in sports activities and LBM were positively correlated to maximum biting force (p < 0.01), while the amount of masticatory action for one day was not. 3) All subjects, especially those in the low biting force group seldom had food requiring the highest amount of masticatory action. CONCLUSION: Having a background in sports activities and LBM are positively correlated with the maximum biting force, while the amount of masticatory action for one day was not correlated positively nor negatively in young females.

Adolescent↗

The periodontal-endodontic interface.

The periodontal tissues and the pulp-dentine complex form an intimate continuum through which pathological changes of either one may lead to infection of the other, and whose management can be fraught with diagnostic and therapeutic difficulty. The purpose of this review paper is to explain the nature of that relationship and to provide pointers which may assist in the diagnostic process and thus enable appropriate management from the outset. Traditional classifications of lesions affecting the periodontal-endodontic complex have caused confusion by attempting to form diagnoses which indicate the putative primary source of infection. We would suggest that the origin of the infection is irrelevant to the management process, and that what is important is whether either, or indeed both, of the tissues are viable or not. Successful therapy will only result from the establishment of an accurate diagnosis, and forming such a diagnosis requires a methodical multi-staged approach.

Dental Pulp Diseases↗

Non-metal post systems.

For many years metals, whether cast or prefabricated, have been exclusively used to construct posts as foundations for indirect restorations. Developments in composite and ceramic materials have resulted in the introduction of metal-free post systems as alternatives. This article provides an overview of the systems currently available, gives guidance on their use, and discusses some of the principles underlying the clinical performance of posts.

Carbon↗

Direct core materials.

There are many materials that can be used for direct-placement cores. Although the scientific evidence is incomplete, some materials are better suited to this task than others. This article provides an overview of direct-placement core materials and highlights what clinicians should consider when assessing a new product.

Composite Resins↗

Surgical emphysema following a restorative procedure: A case report.

UNLABELLED: Surgical emphysema is a rare complication following a restorative procedure, despite the use of air-driven handpieces. Although most cases resolve spontaneously, it should be correctly managed to avoid potentially life-threatening situations, such as pneumomediastinum and pneumothorax. CLINICAL RELEVANCE: Surgical emphysema, although rare, can occur following certain dental procedures. It should be avoidable but, when it occurs, appropriate management is essential.

Dental High-Speed Equipment↗

Zirconia-based all-ceramic crowns and bridges: three case reports.

UNLABELLED: The search for a clinically viable all-ceramic bridge framework has been monotonous. Until recently, few materials appear to have the necessary physical and aesthetic properties. However, the development of yttrium tetragonal zirconia polycrystals, and its adoption for use in dentistry by CAD CAM technology, may hold promise as a crown and bridge framework, this being considered suitable for single and multiple units. However, to date, no long-term clinical studies have been reported. This paper describes three cases in which zirconia frameworks were used in crowns and bridges. CLINICAL RELEVANCE: For the patient wishing to receive a non-metal crown or bridge, novel zirconia-based systems hold promise.

Adult↗

Resin-retained bridges re-visited. Part 2. Clinical considerations.

Resin-retained bridges have been used clinically since the 1970s, and offer a more conservative approach to the restoration of edentulous spaces than conventional bridgework. They are easy to place, cheap to fabricate and have been shown to be cost-effective. Despite this, they are not frequently used in general dental practice and they have an undeserved reputation for failure. Since their initial introduction, they have undergone a number of changes to their method of retention, and the materials used in their construction. This has resulted in a predictable, aesthetic restoration which, barring the use of implants, is often the treatment of choice where teeth adjacent to an edentulous space are minimally or not restored. This article hopes to show the clinical techniques required to produce predictable resin-retained bridgework in general practice.

Bruxism↗