Search PubMedSearch

SEARCH · Search PubMed

Results for “self-directed learning”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

376 records · Page 7Linked to original sources

The potential of clustering methods for pre-test triage in sleep medicine: A systematic review.

Sleep disorders exhibit substantial heterogeneity, and traditional classifications may not fully capture clinically relevant subtypes. Clustering techniques can identify patient subgroups that improve phenotypic characterization and may support personalized management. This systematic review evaluated the application of clustering in sleep medicine, with particular focus on its potential use as a pre-test triage tool prior to formal sleep testing. PubMed/MEDLINE, Embase, Web of Science, and Scopus were searched to February 2025. Eligible studies applied clustering to classify sleep disorders in adults. Two reviewers independently conducted screening, data extraction, and risk-of-bias assessment using QUADAS-2. The protocol was registered on PROSPERO. Fifty-one studies (1983-2025) were included, predominantly focused on obstructive sleep apnea (OSA) (n = 38, 74%). Hierarchical clustering (n = 20) and K-means clustering (n = 14) were the most frequently used techniques. Internal validation was reported in only 18% of studies, and external validation was reported in only 1 study. Seven studies relied exclusively on baseline clinical, demographic, or questionnaire data, representing pre-test scenarios, whereas most incorporated polysomnography-derived variables, limiting their applicability to early clinical stratification. Hierarchical clustering was the most commonly applied method; however, the overall lack of validation limits confidence in the robustness and clinical applicability of identified phenotypes. The potential role of clustering as a pre-test triage strategy remains largely unexplored, as most studies focused on post-diagnostic phenotyping and were affected by incorporation bias. Future research should prioritize pre-test clinical variables, rigorously validate internally and externally, and adopt standardized methodological and reporting practices to facilitate clinical translation.

Humans

Effectiveness of symptom map-based education in the management of premenstrual syndrome: a randomized controlled trial.

PURPOSE: To evaluate the effectiveness of a symptom map-based educational intervention for the non-pharmacological management of premenstrual syndrome (PMS), with a focus on symptom reduction among women with differing baseline symptom severity. METHODS: This randomized controlled study was conducted between May and December 2024. A total of 110 women meeting diagnostic criteria for PMS were randomly assigned to an intervention group (n = 55) or a control group (n = 55) using block randomization, and 101 participants completed follow-up assessments. The intervention comprised structured education based on a PMS symptom map and evidence-based self-care strategies. Outcomes included PMS symptom severity (Premenstrual Syndrome Scale), pain intensity (Visual Analog Scale), psychological symptoms (Depression Anxiety Stress Scale-21), and PMS-specific life satisfaction. CLINICAL TRIAL REGISTRATION: NCT06585475. RESULTS: Compared with the control group, women in the intervention group reported significantly lower pain (adjusted mean 4.21 vs. 6.81, p < .001) and stress levels (8.54 vs. 12.03, p < .001) at follow-up. The intervention was particularly effective in reducing PMS symptom severity and depressive symptoms among participants with higher baseline symptom burden. Improvements in PMS-specific life satisfaction were observed, with reductions in depressive symptoms contributing to this effect. CONCLUSION: A symptom map-based educational intervention is a clinically applicable, non-pharmacological approach for PMS management. This structured education appears especially beneficial for women with more severe baseline symptoms and may be integrated into routine gynecological care to support individualized symptom management.

Humans

Specific Instruments for Caregiving Competence Among Family Caregivers of Cancer Patients: A COSMIN Systematic Review of Psychometric Properties.

OBJECTIVE: To evaluate and summarize the psychometric properties of specific instruments for caregiving competence among family caregivers of cancer patients. METHODS: Systematically searched eight databases for studies published up to November 2025. The methodological quality and psychometric properties of the instruments were evaluated using COSMIN 2.0. Evidence grades were rated using the modified GRADE system (four grades: "High," "Moderate," "Low," and "Very Low"), and recommendations were formulated (Category A: recommended, Category B: potential with further validation, and Category C: not recommended). RESULTS: Seven studies were included, comprising three specific instruments: the Care Competency Scale for Family Caregivers in Home Palliative Care (CCSHPC) (n = 1), the Caregiver Caregiving Self-Efficacy Scale-Oral Cancer (CSES-OC) (n = 1), and the Caring Ability of Family Caregivers of Patients with Cancer Scale (CAFCPCS) (n = 5). Both the CCSHPC and CAFCPCS received Category B recommendations, demonstrating "adequate" content validity with evidence grades rated "very low" and "low," respectively. The CAFCPCS also shows good structural validity ("moderate") and internal consistency ("low") in some cultural contexts. The CSES-OC is a Category C recommendation, with high-quality evidence indicating "inadequate" criterion validity. CONCLUSION: Few specific instruments exist, and most did not strictly follow COSMIN guidelines. The CAFCPCS is provisionally recommended based on relative evidence superiority rather than complete psychometric validation. Further cross-cultural and localized instrument development is warranted. IMPLICATIONS FOR NURSING PRACTICE: Use well-validated specific instruments to identify strengths and weaknesses in the caregiving competencies of family caregivers of cancer patients, enabling them to deliver high-quality home-based cancer care.

Female

AI Health message intervention: The role of message customization and message source in breast cancer screening among women of color.

OBJECTIVES: To examine the effectiveness of breast cancer screening messages with varying levels of customization (generic, targeted, and tailored) and to compare AI-generated versus human-generated messages. METHODS: A between-subjects experimental design with a control condition was employed. Message content followed a standardized structure and varied by level of customization: generic, targeted (demographic-based), and tailored (perceived susceptibility- and barrier-based). Messages were developed by either the authors or GenAI (ChatGPT-4o). A total of 391 participants recruited via Prolific were randomly assigned to five groups (generic, targeted-human, targeted-AI, tailored-human, and tailored-AI). Self-efficacy, behavioral intentions, attitudes, and message believability were measured using different scales. RESULTS: Customized (tailoring and targeting) health messages performed comparably to generic messages in shaping positive health outcomes. GenAI-generated messages also produced outcomes comparable to those of human-generated messages under standardized conditions. Significant negative indirect effects through message believability for the human-tailored condition was found relative to the generic condition. CONCLUSIONS: GenAI may be a useful tool for developing and customizing scalable health messages. Its effectiveness depends not only on customization but also on maintaining message quality, including readability, clarity, coherence, naturalness, and credibility. PRACTICAL IMPLICATIONS: GenAI may support health practitioners in developing customized and scalable breast cancer messages. However, professional review remains necessary to ensure that the message is culturally appropriate, responsive to patient concerns, and suitable for use alongside patient-provider communication.

Humans

Effectiveness of transcranial direct current stimulation with and without positive mood induction on worry and transdiagnostic cognitive-emotional processes: A randomized controlled trial.

The present study investigated the effectiveness of transcranial direct current stimulation (tDCS), with and without positive mood induction, on worry and key transdiagnostic cognitive-emotional processes, including attentional bias, working memory, problem solving, and emotion regulation, in individuals with high levels of worry. This single-blind randomized controlled trial included 45 individuals with high levels of worry. After a structured clinical interview, participants were randomly assigned, with gender balancing, to one of three groups: (1) tDCS alone, (2) tDCS combined with positive mood induction, or (3) a sham control group. Outcome measures were administered at three time points (pretest, posttest, and one-month follow-up) and assessed attentional bias (Dot Probe Task), working memory (1-back task), problem solving (Tower of London task), emotion regulation (Gross's Emotion Regulation Questionnaire), and worry severity (Penn State Worry Questionnaire; PSWQ). Repeated-measures ANOVA showed that both active groups (tDCS alone and tDCS + positive mood induction) significantly improved attentional bias, worry, working memory, problem solving, and emotion regulation compared to controls (p < 0.05). The combined intervention produced significantly greater gains than tDCS alone in working memory, problem solving, emotion regulation (p < 0.05), and reductions in attentional bias and worry (p < 0.001). All effects persisted at one-month follow-up (p < 0.05). tDCS reduces worry and attentional bias and enhances cognition and emotion regulation in individuals with high levels of worry. The combined intervention produced larger and more sustained improvements than tDCS alone across the assessed behavioral outcomes. These findings support further investigation of combining tDCS with structured positive mood induction while the mechanisms underlying the additional benefits remain to be established.

Humans

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans

Parents' Awareness of Their Adolescents' Sexual Behaviors and Experiences: A Concordance Analysis.

PURPOSE: Adolescence is a developmental period during which sexual exploration is normative. Parental awareness of adolescents' sexual behaviors can be protective during this stage; however, research suggests both parents and adolescents tend to avoid open conversations about these sensitive issues. This study aimed to examine concordance between parent proxy-reports and adolescent self-reports across three domains of adolescents' sexual behaviors and experiences. METHODS: Data were collected from a national sample of 522 parent-adolescent dyads (aged 15-17 years) from the AmeriSpeak panel (data collected May-September 2022). Prevalence-adjusted bias-adjusted kappa (PABAK) statistics were calculated to evaluate agreement. RESULTS: Findings revealed weak-to-moderate concordance regarding adolescents sending and receiving sexual photos (PABAKs = 0.54-0.79), whereas stronger concordance was observed for experiences related to nonconsensual sharing of sexual photos (PABAKs = 0.92-0.94), with high agreement largely driven by low reported prevalence of these experiences. Strong concordance regarding whether adolescents had ever had sex (PABAK = 0.80) was largely driven by both parents and adolescents reporting the adolescent had not had sex. Concordance regarding sexually transmitted infection and pregnancy prevention methods varied, ranging from weak to strong agreement across specific methods (or lack thereof; PABAKs = -0.07-0.79). DISCUSSION: Results highlight significant discrepancies in parents' knowledge about their adolescents' sexual behaviors and experiences. Interventions aimed at enhancing trust and open dialogue between parents and adolescents about sexuality-related topics, as well as ensuring adolescents have a variety of trusted sources to consult for sexual information, can help adolescents make informed sexual health decisions.

Humans

A systematic approach to standardizing the visual appearance of endometriotic lesions for artificial intelligence recognition.

INTRODUCTION: Numerous studies have shown that the diagnostic performance and reproducibility of visual recognition of endometriosis during laparoscopy are poor. The use of artificial intelligence (AI) seems relevant for exhaustive lesion recognition. Standardization of the visual classification of lesions, in the form of an ontology, is an essential prerequisite to enable medical experts to annotate surgical data consistently and subsequently allow engineers to train and build an artificial intelligence tool for endometriosis recognition. MATERIAL AND METHODS: A systematic search was conducted in the MEDLINE (via PubMed), EMBASE, and the Cochrane Library databases up to May 2022, aiming to identify studies describing the laparoscopic visual appearance of superficial endometriosis, endometriomas, and deep infiltrating endometriosis. The accumulated data in the literature concerning the visual appearance of the different forms of endometriosis were used to create an ontology that could be used for artificial intelligence applications. RESULTS: Out of 932 articles screened, 35 studies were selected based on the inclusion criteria of human subjects with histologically confirmed endometriosis lesions visualized via laparoscopy. The selected studies were reviewed to develop a visual ontology of endometriosis lesions observed via laparoscopy. The lesions were categorized into 4 classes and further subdivided into 11 subclasses: superficial (black, red, white, or subtle), adhesions (dense or filmy), deep (obliteration, retraction, or deformation), and ovarian (endometrioma or chocolate fluid). The positive predictive value (PPV) varied across lesion types: black lesions (PPV 47%-97%), red lesions (PPV 33%-100%), white lesions (PPV 20%-81%), and ovarian endometriosis (PPV 42%-98%). Nonspecific lesions such as adhesions (PPV 16%-50%) and subtle superficial lesions (PPV 0%-67%) presented lower PPVs. Deep endometriosis lesions, often buried within organs, required indirect signs (obliteration, retraction, deformation) for identification. CONCLUSIONS: The visual ontology proposed in this systematic search could facilitate the detection and classification of endometriosis lesions using artificial intelligence. This study highlights the challenges of reaching a consensus on lesion recognition and classification in AI projects due to the diverse visual presentations of endometriosis.

Humans

Direct Oral Anticoagulants as Primary or Secondary Treatment for Heparin-Induced Thrombocytopenia (HIT) and Associated Thromboembolism (HITT)-A Meta-Analysis.

INTRODUCTION: Heparin-induced thrombocytopenia (HIT) is associated with a high risk for thrombosis. The role of direct oral anticoagulants (DOACs) is still emerging and data are limited considering efficacy and safety among patients with HIT. The aim of this review is to evaluate current data on DOACs as primary or secondary treatment among patients with HIT. METHODS: This is a systematic review utilising Pubmed, Scopus and Embase online databases. Eligible studies were published up to December 2024 evaluating DOACs as primary or secondary treatment among patients with HIT and/or associated thrombosis (HITT). Primary outcomes included thrombosis rate (TR) and bleeding rate (BR) during follow-up. RESULTS: A total of 44 publications were included (29 case reports, 5 case studies and 10 cohort studies [n&#x2009;>&#x2009;10 patients]). Regarding treatment, 19 articles evaluated only rivaroxaban, 7 articles only apixaban, 11 articles only dabigatran and 7 articles more than one regimen. A total of 352 patients were included. Overall, 190 patients (53.8%) were given DOAC as primary treatment whereas 162 patients were given a parenteral treatment first and continued with a DOAC. Mean nadir platelet count at diagnosis was 63&#x2009;000/&#x3bc;L. HITT rate was 190/352 (53.9%; 8% had arterial thrombosis). Mean follow-up was 7.6&#x2009;months. TR was 20/352 (Pooled proportion&#x2009;=&#x2009;0.064 [95% CI&#x2009;=&#x2009;0.042-0.092]) (30% of them were new thromboses without initial thrombosis), and BR was 9/352 (Pooled proportion&#x2009;=&#x2009;0.039 [95% CI&#x2009;=&#x2009;0.022-0.062]). Finally, there was no difference found regarding TR and BR between primary or secondary treatment, and among different regimens. CONCLUSIONS: DOACs are associated with low rates of thrombosis and major bleeding among patients treated for HIT or HITT, either as primary or secondary treatment. However, the certainty of evidence is very low because of the quality and limitations of the available studies.

Humans

A single session of high-definition transcranial direct current stimulation does not modulate effects of knee two-point discrimination training or sensorimotor function in healthy adults: Double-blind randomised controlled trial.

BACKGROUND: Benefits of sensory-training interventions on sensorimotor outcomes are inconsistent, and it is unclear whether transcranial direct current stimulation (tDCS) can enhance proprioception, which is fundamental to neuromuscular control. Existing evidence is dominated by upper-limb studies, so transferability to the knee is unclear. This study investigated whether a single session of anodal high-definition (HD)-tDCS, alone or combined with brief two-point discrimination (TPD) training, enhances knee sensorimotor function and performance in healthy adults. METHODS: In a double-blind randomised-controlled trial, 57 healthy participants received (1) 20-min, 1&#xa0;mA anodal HD-tDCS over the knee primary somatosensory (S1) map or sham stimulation, and (2) 15-min knee TPD training or no training. Knee somatosensory, sensorimotor, and functional performance measures were assessed pre- and immediately post-intervention. Three-way mixed-design ANOVAs, equivalence testing (smallest effect size of interest &#x3b7;2&#xa0;=&#xa0;0.02), Bayes factors, and linear mixed-effects models quantified effects. RESULTS: HD-tDCS, TPD training, and their sequential combination had no effect on any outcome measure (p&#xa0;&#x2265;&#xa0;0.05; &#x3b7;2&#xa0;&#x2264;&#xa0;0.015). Confidence intervals spanned equivalence bounds, and equivalence testing results were non-significant (p&#xa0;&#x2265;&#xa0;0.05). Bayes factors (<0.33) showed moderate evidence for the null (no effect). Mixed-effects modelling attributed &#x2264;8% of total variance to intervention fixed effects, with the remainder captured by participant-level random effects. CONCLUSION: A single 20-minute session of 1&#xa0;mA HD-tDCS, with or without brief TPD training, does not acutely modify knee somatosensory, sensorimotor, or functional performance in healthy adults. Existing evidence at the hand may not translate to the lower limb. Future work should investigate higher-dose, multi-session, task-concurrent, or network-targeted strategies in clinical populations.

Humans

Effects of Transcranial Direct Current Stimulation and Individualized Physical Therapy on Pain and Function in Individuals With Chronic Knee Pain: A Pilot Study.

BACKGROUND AND PURPOSE: Noninvasive brain stimulation is a promising neuromodulatory intervention for chronic pain. This study aimed to determine the impact that transcranial direct current stimulation (tDCS) in combination with individualized physical therapy (PT) has on pain and function in individuals with chronic knee pain. METHODS: This study was a preliminary pragmatic, triple-blinded, randomized, and sham-controlled clinical trial performed in an outpatient orthopedic physical therapy clinic. Participants participated in 5 sessions of active or sham tDCS followed by individualized PT intervention. Pain outcomes included the Numeric Pain Rating Scale, Movement-Evoked Pain, pressure pain thresholds (PPT), and the Central Sensitization Inventory. Functional outcomes included the 2-minute walk test, 5-time sit-to-stand test, quadriceps strength, knee range of motion, Patient Specific Functional Scale, and the Lower Extremity Functional Scale. RESULTS: Thirty participants with chronic knee pain completed the study. There were no significant differences observed for primary patient-centered pain and functional outcomes. For secondary outcomes, the active tDCS group had a significant effect (p&#xa0;<&#xa0;0.05) on percent change in lateral joint line PPT and a significant multivariate effect of group on PPT change scores for 3-site and 5-site clusters (p&#xa0;<&#xa0;0.05). Exploratory responder analyses demonstrated that the active tDCS group was 12.8 times more likely to achieve the minimum detectable change in quadriceps strength improvement compared with the sham tDCS group (p&#xa0;<&#xa0;0.05). DISCUSSION: There were no significant between-group differences for primary pain and functional outcomes. However, the active tDCS group showed improvements in pain sensitivity, as measured by PPT, and quadriceps strength, which were superior to those seen in the sham tDCS group. These preliminary findings provide insight into possible mechanisms of tDCS in addressing pain as opposed to efficacy. Given that there were no clear between-group differences in patient-centered outcomes, there is insufficient evidence for routine tDCS use for chronic knee pain. TRIAL REGISTRATION: NCT06132412.

Humans

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3&#xa0;mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100&#xa0;ng/mL (R2&#xa0;&#x2265;&#xa0;0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within &#xb1;15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans

A hybrid effectiveness-implementation trial to integrate precision skin cancer risk feedback in federally qualified health centers.

BACKGROUND: Skin cancers are the most common type of cancer in the United States, occur in all segments of the population, and are preventable. Our previous research with primary care patients' demonstrated interest in and efficacy of a precision prevention intervention providing feedback on MC1R risk level (higher versus average) in combination with prevention education materials relative to a standard educational intervention. Our current study is a hybrid type 1 effectiveness-implementation trial deployed at six federally-qualified health centers. This paper presents the study protocol. METHODS: A community advisory panel will guide development of study materials and measures. Staff training at each clinic will be completed in-person. Patients will be approached and screened in-person. Those completing genetic testing and the baseline survey will be randomized to the precision versus standard intervention for each risk level with a target sample size of 286 for each combination. Primary outcomes of effectiveness, assessed at 6 and 12&#xa0;months, include a tanning score (5 items assessing intentional and unintentional tanning), number of sunburns, conduct of a skin self-examination, and electronic health record documentation of clinician-patient communication about skin cancer prevention. Effectiveness comparisons will focus on the precision relative to the standard intervention among higher risk participants. Implementation data will be collected to identify barriers and facilitators. RESULTS: Effectiveness and implementation outcomes will be evaluated following study completion. CONCLUSIONS: Results will guide subsequent scale-up of the precision intervention, including modifications of the intervention as well as methods for implementation. CLINICAL TRIALS IDENTIFIER: NCT07222995.

Humans

Assessing the effects of non-invasive transcranial electrical stimulation (tACS and tDCS) on electrophysiological sleep parameters - a systematic review.

Transcranial electrical stimulation (tES), including transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS), is considered a safe method to modulate cortical activity and endogenous brain oscillations. Given the therapeutic potential of tES across various clinical conditions and the central role of sleep in restoration and memory consolidation, numerous studies have investigated its effects on sleep and sleep-related parameters, yielding inconsistent results. This systematic review provides an up-to-date synthesis of 51 studies assessing the impact of tES on objectively measured electrophysiological sleep outcomes in both healthy individuals and clinical populations. The reviewed studies demonstrate heterogeneous effects, reflecting substantial variability in study designs. Nonetheless, consistent trends emerge, including reduced NREM1 and increases in total sleep time, NREM2, and NREM3 following tES. Moreover, slow-oscillatory tES increased slow-wave power during sleep. Here we show that tES, particularly slow-oscillatory tES, may positively influence sleep architecture and continuity by modulating endogenous brain oscillations. However, due to heterogeneous stimulation protocols, inconsistent findings, the limited number of significant effects and substantial risk of bias the current evidence remains inconclusive. Well-designed, large-scale trials targeting specific sleep outcomes are needed to clarify the therapeutic potential of tES.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Design of an innovative framework based hybrid catalyst for simultaneous and sensitive monitoring of food additive and preservative of vanillin and nitrite in direct samples.

As vanillin (VAN) and nitrite (NIT) contamination in the food chain poses substantial threats to environmental and public health, rapid and portable detection is essential. The present study presents the first electrochemical sensor report based on a hybrid composite of Ni-TPA-MOF and MoS2/Co3O4. The oxidation of VAN and NIT exhibited sharp peaks and less over-potential on Ni-TPA-MOF/MoS2/Co3O4/GCE than on control electrode surfaces. On modified composite electrode surfaces, pH and scan rate were investigated for VAN and NIT. Further, the oxidation current exhibited high linearity at VAN and NIT concentrations of 5&#xa0;nM-1000&#xa0;&#x3bc;M and 3&#xa0;nM-1250&#xa0;&#x3bc;M, with detection limits of 0.102&#xa0;nM and 0.073&#xa0;nM (S/N&#xa0;=&#xa0;3). We also applied anti-interfering ability (five/ten-fold excess of co-interfering compounds) and practical tests to various food-based real samples, with high recoveries of 98.85-102.41%. This study highlights the catalytic properties of Ni-TPA-MOF/MoS2/Co3O4 and demonstrates the sensor as a promising tool for food safety.

Benzaldehydes

Proteomics in environmental pollution research: Advances, challenges, and future directions.

Environmental proteomics has emerged as a powerful approach for elucidating the molecular mechanisms underlying pollutant-induced biological effects. Although this field has developed rapidly, the systematic review of recent proteomics applications in environmental pollution research remains limited. This review explored the emerging roles of toxicoproteomics in biomarker discovery and mechanistic elucidation, as well as ecotoxicoproteomics in ecological risk assessment and bioremediation strategies. Here, we review the field, highlighting recent trends such as the integration of proteomics with genomics, transcriptomics, and metabolomics to provide a comprehensive view of biological responses to environmental stressors. We further discuss the growing application of artificial intelligence in improving proteomics data interpretation and accelerating biomarker discovery. In addition, recent technological advances in environmental proteomics are highlighted, including next-generation tissue microarray proteomics, nanoscale proteomics, single-cell proteomics, and spatial proteomics. Despite its potential, proteomics faces challenges, such as high operational costs, computational complexity in analysis, and technical limitations in low-abundance protein detection. We propose that the convergence of proteomics with artificial intelligence and multi-omics approaches offers promising solutions to these challenges, enhancing the practical application of proteomics in environmental monitoring and risk assessment.

Proteomics

Pedagogical Efficacy of LLM-Generated Synthetic Data Versus Real-World Clinical Records: A Randomized Controlled Non-Inferiority Trial.

BACKGROUND: Expert-reviewed clinical cases generated by large language models (LLMs) may supplement case resources in medical education, but their short-term educational performance relative to real-case-derived teaching materials remains uncertain. We compared immediate post-training test performance after teaching with the two types of case materials and assessed non-inferiority against a prespecified margin. METHODS: We conducted a prospective, parallel-group, randomized non-inferiority trial. Through the Wenjuanxing online platform, participants were randomized 1:1 to learn with either real-case-derived teaching cases compiled by clinicians and reviewed by experts or AI-generated clinical cases produced by Gemini 3.0 Pro from fully de-identified matched real cases and reviewed by three senior general surgery specialists with full-professor rank. The primary outcome was the total score on an independent 10-item immediate post-training test (0-10 points), with a prespecified non-inferiority margin of -0.5 points. Secondary outcomes included the training-phase performance score, learning efficiency index, single-item mental effort rating, case realism, and case-source judgment. RESULTS: A total of 403 participants were randomized, of whom 386 were included in the modified intention-to-treat analysis: 192 in the real-case group and 194 in the AI-generated case group. The mean post-training test score was 4.95 (SD, 3.35) in the real-case group and 4.61 (SD, 3.35) in the AI-generated case group. The mean difference (AI-generated minus real-case group) was -0.335 points (95% CI, -1.006 to 0.337). Because the lower bound of the confidence interval was below the prespecified non-inferiority margin of -0.5 points, non-inferiority was not demonstrated (one-sided P = 0.314). No significant between-group differences were observed in the training-phase performance score, learning efficiency index, or single-item mental effort rating. AI-generated cases received lower realism ratings for Level 3 cases. The proportion of participants with at least one high-confidence completely incorrect response was 1.6% in the real-case group and 2.1% in the AI-generated case group. CONCLUSIONS: In this short-term, text-based online case-learning setting, no statistically significant between-group difference was observed in immediate post-training test performance; however, non-inferiority of AI-generated clinical cases relative to real-case-derived teaching materials was not demonstrated.

Humans