Cardiac diffusion MRI without motion effects.

We present a method for diffusion tensor MRI in the beating heart that is insensitive to cardiac motion and strain. Using a stimulated echo pulse sequence with two electrocardiogram (ECG) triggers, diffusion-encoding bipolar gradient pulses are applied at identical phases in consecutive cardiac cycles. In this experiment, diffusion is encoded at a single phase in the cardiac cycle of less than 30 ms in duration. This encoding produces no phase shifts for periodic motion and is independent of intervening strains. Studies in a gel phantom with cyclic deformation confirm that by using this sequence we can map the diffusion tensor free of effects of cyclic motion. In normal human subjects, myocardial diffusion eigenvalues measured with the present method showed no significant change between acquisitions encoded at maximum contractile velocity (peak) vs. at myocardial standstill (end-systole), demonstrating motion independence of in vivo diffusion measurements. Diffusion tensor images acquired with the present method agree with registered data acquired with a previous cardiac diffusion MRI method that was shown to be valid in the normal heart, strongly supporting the validity of MRI diffusion measurement in the beating heart. Myocardial sheet and fiber dynamics measured during systole showed that normal human myocardial sheet orientations tilt toward the radial during systole, and fiber orientations tilt toward the longitudinal, in qualitative agreement with previous invasive studies in canines. These results demonstrate the technique's ability to measure myocardial diffusion accurately at any point in the cardiac cycle free of measurable motion effect, as if the heart were frozen at the point of acquisition.

Diffusion↗

Magnetization transfer by simple sequences of rectangular pulses.

On-resonant radio frequency (RF) sequences composed of a train of short rectangular pulses of the same kind were optimized in order to obtain selective saturation of protons with short transverse relaxation times for magnetization transfer purposes. It is demonstrated that the sequences regarded allow a good adaptation to different requirements for magnetization transfer examinations on whole-body imagers. The sequences presented here provide relatively strong saturation of protons with very short transverse relaxation times T2 approximately less than 50 microseconds, whereas signals from protons with long T2 to be recorded are hardly influenced in a broad frequency range. The sequences are especially advantageous for applications in pulse files with limited numbers of support points.

Magnetic Resonance Imaging↗

Investigation of Overhauser effects between pseudouridine and water protons in RNA helices.

The inherent chemical properties of RNA molecules are expanded by posttranscriptional modification of specific nucleotides. Pseudouridine (psi), the most abundant of the modified bases, features an additional imino group, NH1, as compared with uridine. When psi forms a Watson-Crick base pair with adenine in an RNA helix, NH1 is positioned within the major groove. The presence of psi often increases thermal stability of the helix or loop in which it is found [Hall, K. B. & McLaughlin, L. (1992) Nucleic Acids Res. 20, 1883-1889]. X-ray crystal structures of transfer RNAs [e.g., Arnez, J. & Steitz, T. (1994) Biochemistry 33, 7560-7567] have depicted water molecules bridging psiNH1 groups and nearby phosphate oxygen atoms, but direct evidence for this interaction in solution has not been acquired. Toward this end, we have used a rotating-frame Overhauser effect spectroscopy-type NMR pulse sequence with a CLEAN chemical-exchange spectroscopy spin-lock pulse train [Hwang, T.-L., Mori, S., Shaka, A. J. & van Zijl, P. C. M. (1997) J. Am. Chem. Soc. 119, 6203-6204] to test for psiNH1-water cross-relaxation effects within two RNA helices: (i) a complementary duplex, in which psi is not associated with structural change, and (ii) an RNA duplex representing the eukaryotic pre-mRNA branch-site helix from Saccharomyces cerevisiae, in which a conserved psi extrudes the branch-site adenosine from the helix. Our data implicate a water-psiNH1 hydrogen bond both in stabilizing the complementary helix and in favoring formation of the unique structure of the branch-site helix.

Adenosine↗

DNA sequencing with pulsed-field capillary electrophoresis in poly(ethylene oxide) matrix.

DNA sequencing by using pulsed-field capillary electrophoresis in a linear polymer matrix was performed in this work. The effects of waveform, frequency, modulation depth and heating were investigated. The separation performance for Sanger DNA fragments up to 1000 bp using a pulsed field was compared to isoelectric and isorheic conditions. A separation mechanism in the flexible poly(ethylene oxide) (PEO) gel was also suggested. We found that temperature change generated by either a pulsed field or ultrasound during DNA sequencing can have a deleterious effect on the separation efficiency.

Electrophoresis, Capillary↗

Analytical description of the effect of adiabatic pulses on IS, I2S, and I3S spin systems.

An analytical description of the evolution of magnetization in InS spin systems (1 </= n </= 3) during the course of an adiabatic pulse applied on spin S is provided. Calculations show that multiple-quantum terms are created during the pulse and that the rate at which in-phase and antiphase I-spin magnetization components interchange during spin-echo-based pulse sequences is decreased relative to the case where a hard inversion pulse is substituted for the adiabatic pulse. This has important consequences for purging schemes making use of such frequency-swept pulses. Simulations demonstrate that the evolution of in-phase I magnetization is essentially independent of n.

Magnetic Resonance Spectroscopy↗

Efficient simulation of coherence transfer pathway selection by phase cycling and pulsed field gradients in NMR

The selection of well-defined coherence transfer pathways is an essential feature of all but the simplest NMR and EPR pulse sequences. This selection can be achieved by phase cycling and by pulsed field gradients. The properties of the RF-pulses (flip angle, offset effects, inhomogeneity) and transport phenomena (diffusion, flow) in conjunction with gradients cause a weighting of the different coherence transfer pathways. We present a method by which the selection process can be simulated efficiently and visualized easily. In its basic form it involves straightforward matrix manipulations without reference to the density matrix and the particular spin system. This method is implemented in a MATLAB program, called CCCP (Complete Calculation of Coherence Pathways). Copyright 1998 Academic Press.

Journal Article↗

Analysis of J coupling-induced fat suppression in DIET imaging.

The DIET (or dual interval echo train) sequence, a modification of the fast spin echo (FSE) sequence that selectively reduces signal from fat in MR images, has been investigated. The DIET sequence uses an initial echo spacing longer than that of a conventional FSE sequence, thus allowing J coupling-induced dephasing to take effect. The sequence is evaluated theoretically, and its effectiveness on a hydrocarbon (1-pentene) is demonstrated numerically using density matrix calculations. The sequence is also evaluated experimentally using in vitro solutions and in vivo imaging. The efficacy of the sequence is compared for different lipid chemical structures, field strengths, and pulse sequence parameters.

Adipose Tissue↗

Selective dephasing of OH and NH proton magnetization based on (1)H chemical-shift anisotropy recoupling.

A method for selectively suppressing the signals of OH and NH protons in (1)H combined rotation and multiple-pulse spectroscopy (CRAMPS) and in (1)H-(13)C heteronuclear correlation (HETCOR) solid-state NMR spectra is presented. It permits distinction of overlapping CH and OH/NH proton signals, based on the selective dephasing of the magnetization of OH and NH protons by their relatively large (1)H chemical-shift anisotropies. For NH protons, the (14)N-(1)H dipolar coupling also contributes significantly to this dephasing. The dephasing is achieved by a new combination of heteronuclear recoupling of these anisotropies with (1)H homonuclear dipolar decoupling. Since the 180 degrees pulses traditionally used for heteronuclear dipolar and chemical-shift anisotropy recoupling would result in undesirable homonuclear dephasing of proton magnetization, instead the necessary inversion of the chemical-shift Hamiltonian every half rotation period is achieved by inverting the phases of all the pulses in the HW8 multiple-pulse sequence. In the HETCOR experiments, carefully timed (13)C 180 degrees pulses remove the strong dipolar coupling to the nearby (13)C spin. The suppression of NH and OH peaks is demonstrated on crystalline model compounds. The technique in combination with HETCOR NMR is applied to identify the CONH and NH-CH groups in chitin and to distinguish NH and aromatic proton peaks in a peat humin.

Journal Article↗

Identification of solvent-exposed regions of an FK-506 analog, ascomycin, bound to FKBP using a paramagnetic probe.

The solvent-exposed regions of (U-13C)ascomycin when bound to its putative target protein, FKBP, have been identified based on the different proton longitudinal relaxation rates (R1 = 1/T1) measured in the absence and presence of the paramagnetic relaxation reagent, 4-hydroxy-2,2,6,6-tetramethyl-piperidinyl-1-oxy (HyTEMPO). The proton T1S of bound ascomycin were determined using a pulse sequence (T1-HMQC) which consists of a 180 degree proton pulse and a variable delay (tau) followed by a heteronuclear multiple quantum correlation (HMQC) experiment. The solvent-exposed regions of ascomycin determined by these experiments are compared to NOE data in which ascomycin/FKBP contacts were identified and to the X-ray structure of the FK-506/FKBP complex.

Binding Sites↗

In vivo 1H-NMR procedure to determine several rat cerebral metabolite levels simultaneously, undisturbed by water and lipid signals.

Methods developed for in vivo 1H-NMR spectroscopy are evaluated and applied using conscious rats. Good quality 1H-spectra of the brain are obtained using a surface coil and a spin echo pulse sequence with the binomial 1-1 and 2-2 water suppression pulses. However, comparing spectra from various rats with each other the water and lipid signals, which cause spectral overlap problems, may differ while the other spectral peaks agree well. Spatially one- and two-dimensional 1H spectroscopic imaging of the rat brain shows that the former signals stem from distinct spatial regions localized close to the rf coil. From a spectroscopic image, a spectrum over a limited spatial region is constructed in which the water signals are strongly reduced, the lipid signals are eliminated and lactic acid can be observed clearly simultaneously with other metabolites.

Animals↗

Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses.

OBJECTIVE: An important source of error in arterial spin labeling (ASL) is incomplete static tissue subtraction due to imperfect slice profiles. This effect can be reduced by saturating the spins in the imaging area prior to labeling. In this study, the use of optimized presaturation is compared with the use of optimized RF pulses for minimizing this error. MATERIALS AND METHODS: Different methods for optimizing presaturation were simulated by numerical solution of the Bloch equation. Presaturation was optimized by changing the number of presaturation pulses, their position in the pulse sequence and the area of the crusher gradients following each saturation pulse. It was also investigated whether the use of optimized presaturation could reduce the tag gap needed to ensure complete static tissue subtraction. Simulation results were verified using phantom and in vivo studies at 3T. RESULTS: In proximal inversion with control for off-resonance effects, optimized presaturation could reduce the necessary tag gap to 15% of the imaging slab for experiments using standard RF pulses, while c-FOCI RF pulses could reduce it to 11%. In flow-sensitive alternating inversion recovery, a single presaturation pulse could reduce the inversion width to 122% of the imaging slab and neither multiple presaturation pulses nor optimized RF pulses could reduce it further. CONCLUSION: Optimized presaturation can reduce the necessary inversion width to the same level as if using optimized RF pulses and can, therefore, be used to optimize ASL sensitivity. Furthermore, optimized presaturation can reduce the B(1)-dependent sensitivity in static tissue subtraction.

Adult↗

Determination of full 13C isotopomer distributions for metabolic flux analysis using heteronuclear spin echo difference NMR spectroscopy.

13C-isotopomer labeling experiments play an increasingly important role in the analysis of intracellular metabolic fluxes for genetic engineering purposes. 13C NMR spectroscopy is a key technique in the experimental determination of isotopomer distributions. However, only subsets of isotopomers can be quantitated using this technique due to redundancies in the scalar coupling patterns and due to invisibility of the 12C isotope in NMR. Therefore, we developed and describe in this paper a 1H NMR spectroscopy method that allows to determine the complete isotopomer distribution in metabolites having a backbone consisting of up to at least four carbons. The proposed pulse sequences employ up to three alternately applied frequency-selective inversion pulses in the 13C channel. In a first application study, the complete isotopomer distribution of aspartate isolated from [1-13C]ethanol-grown Ashbya gossypii was determined. A tentative model of the central metabolism of this organism was constructed and used for metabolic flux analysis. The aspartate isotopomer NMR data played a key role in the successful determination of the flux through the peroxisomal glyoxylate pathway. The new NMR method can be highly instrumental in generating the data upon which isotopomer labeling experiments for flux analysis, that are becoming increasingly important, are based.

Ascomycota↗

Small hepatocellular carcinoma versus small cavernous hemangioma: differentiation with MR imaging at 2.0 T.

Eighteen small hepatocellular carcinomas (HCCs) and 38 hemangiomas less than 5 cm in diameter were studied with magnetic resonance (MR) imaging at 2.0 T. Relatively T1-weighted spin-echo (SE) 500/30 (repetition time msec/echo time msec) images and proton-density 2,000/30 images showed nonspecific contrast-to-noise ratios (C/Ns) and intensity ratios in HCCs and hemangiomas. On T2-weighted 2,000/60, 90, 120, 150, and 180 images, hemangiomas had significantly greater C/N and intensity ratios than HCCs (P less than .05). The SE 2,000/180 sequence showed the greatest difference in tumor-liver intensity ratios between small HCCs and hemangiomas, followed by the SE 2,000/150 sequence, but there was no statistically significant difference between the two pulse sequences. However, the SE 2,000/180 sequence is limited in the number of sections obtainable for routine clinical liver imaging. The findings indicate that the SE 2,000/60 sequence is optimal for the detection of small HCCs and hemangiomas and that the SE 2,000/150 sequence is optimal for distinguishing small HCCs from hemangiomas at 2.0 T.

Adult↗

Multisection proton MR spectroscopic imaging of the brain.

The authors developed a hydrogen-1 proton magnetic resonance (MR) imaging method in which metabolic information is acquired by obtaining multiple sections through the brain. A spin-echo sequence is used for section selection, an octangular outer volume saturation pulse for lipid suppression, and a chemical-shift-selective saturation pulse for water suppression. High-quality maps of choline, creatine, and N-acetylaspartate were obtained in six studies performed in four volunteers. Water and lipid signal from the skull area was well suppressed by the pulse sequence used.

Adult↗

Head and neck: initial clinical experience with fast spin-echo MR imaging.

Fast spin-echo (FSE) is a new magnetic resonance (MR) imaging pulse sequence that employs echo trains of 180 degrees radio-frequency pulses to generate multiple refocused echoes during a single repetition-time interval. Phase encoding is reordered with the lowest spatial frequency views obtained in the echoes nearest the desired effective echo time. These techniques were used to examine 30 patients with pathologic conditions of the head and neck. The images were compared with closely matched conventional T2-weighted spin-echo (SE) images obtained during the same examination. Three unblinded readers evaluated 15 sets of both images for lesion conspicuity, motion artifact, diagnostic information, number of lesions seen, image quality, and sharpness of lesion borders. In all categories, FSE images were judged better than or equal to SE images, and in most cases FSE images were obtained in one-fourth to one-half the imaging time. In no case were lesions depicted on conventional T2-weighted SE images missed on FSE images; in fact, more lesions were seen on FSE images than on conventional T2-weighted SE images.

Adult↗

Determining effects of freezing on pasta filata and non-pasta filata mozzarella cheeses by nuclear magnetic resonance imaging.

The formation of ice during freezing of pasta filata and non-pasta filata Mozzarella cheeses, and the spatial redistribution of water T2 relaxation time and the changes of water self-diffusion coefficient (D) within the unfrozen and frozen-stored cheese samples were observed by nuclear magnetic resonance imaging. Images of water spin number density and water T2 relaxation time were obtained using spin-echo imaging pulse sequence. The water self-diffusion coefficient was measured by pulsed-field gradient spin-echo technique. The ice formation was accompanied by loss of signal intensity in the affected areas of the cheese sample. There was a significant change in T2 and D values of water following freezing-thawing, which can be used to characterize the effect of freezing on cheeses. The D values of the frozen-stored pasta filata Mozzarella cheese samples were higher than those for the unfrozen samples. Such a difference was not observed for the non-pasta filata Mozzarella cheese samples. The T2 distributions of frozen-stored pasta filata Mozzarella cheese samples were narrower, and those for the non-pasta filata Mozzarella cheese samples were broader T2. This may be attributed to the microstructure differences between the two cheeses.

Cheese↗

[Magnetic resonance imaging of the brachial plexus. Anatomy].

The brachial plexus is a difficult region to evaluate with radiological techniques. MR imaging has great potentials for the depiction of the various anatomical structures of the brachial plexus--i.e., spinal ganglion, ventral nerve rami root exit of the neural foramina, trunks and cords. Moreover, MR imaging, thanks to its direct multiplanarity, to its excellent soft-tissue contrast, and to its lack of motion artifacts, allows good evaluation of pathologic conditions in the brachial plexus, especially traumas and cancers. On the contrary CT, in spite of its high spatial resolution and good contrast, cannot demonstrate the anatomical structures of the brachial plexus. US detects superficial structures, and conventional radiographs depict only indirect changes in the adjacent lung apex and skeletal structures. From November 1989 to May 1990, 20 normal volunteers (15 males and 5 females; average age: 35 years) were studied with MR imaging. Multisection technique was employed with a dedicated coil and a primary coil. The anatomical structures of the brachial plexus were clearly demonstrated by T1-weighted sequences on the sagittal and the axial planes. T2-weighted pulse sequences on the coronal plane were useful for the anatomical definition of the brachial plexus and for eventual tissue characterization. The correct representation of the anatomical structures of the brachial plexus allowed by MR imaging with our standard technique makes MR imaging the most appropriate exam for the diagnosis of pathologic conditions in the brachial plexus, although its use must be suggested by specific clinical questions.

Adult↗

[FLAIR images of mild head trauma with transient amnesia].

A newly advanced MRI pulse sequence, the FLAIR (fluid-attenuated inversion recovery) imaging, in which a long TE spin echo sequence is used with suppression of the CSF with an inversion pulse, displays the CSF space as a no signal intensity area. We examined 45 cases of mild head trauma with posttraumatic amnesia by FLAIR images and could detect some findings which could not be detected by CT scan and conventional MR images. These findings could be detected in many patients with long post-traumatic amnesia (over 2 hours), but they could not be detected in patients with short posttraumatic amnesia (within 30 mins). These findings existed surrounding lateral ventricles and we classified them into 3 types: type 1 is anterior horn of lateral ventricle, type 2 is the base of frontal lobe, type 3 is cerebral deep white matter. Some of them were examined again by FLAIR images a month later, and these findings had disappeared. We suspect that these lesions were brain edema or mild contusion without hemorrhage.

Adolescent↗