Search PubMed⌕ Search

PubMed · 12111937

Cardiac diffusion MRI without motion effects.

Abstract

We present a method for diffusion tensor MRI in the beating heart that is insensitive to cardiac motion and strain. Using a stimulated echo pulse sequence with two electrocardiogram (ECG) triggers, diffusion-encoding bipolar gradient pulses are applied at identical phases in consecutive cardiac cycles. In this experiment, diffusion is encoded at a single phase in the cardiac cycle of less than 30 ms in duration. This encoding produces no phase shifts for periodic motion and is independent of intervening strains. Studies in a gel phantom with cyclic deformation confirm that by using this sequence we can map the diffusion tensor free of effects of cyclic motion. In normal human subjects, myocardial diffusion eigenvalues measured with the present method showed no significant change between acquisitions encoded at maximum contractile velocity (peak) vs. at myocardial standstill (end-systole), demonstrating motion independence of in vivo diffusion measurements. Diffusion tensor images acquired with the present method agree with registered data acquired with a previous cardiac diffusion MRI method that was shown to be valid in the normal heart, strongly supporting the validity of MRI diffusion measurement in the beating heart. Myocardial sheet and fiber dynamics measured during systole showed that normal human myocardial sheet orientations tilt toward the radial during systole, and fiber orientations tilt toward the longitudinal, in qualitative agreement with previous invasive studies in canines. These results demonstrate the technique's ability to measure myocardial diffusion accurately at any point in the cardiac cycle free of measurable motion effect, as if the heart were frozen at the point of acquisition.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jiangang Dou, Timothy G Reese, Wen-Yih I Tseng, Van J Wedeen. 2002. Cardiac diffusion MRI without motion effects.. https://doi.org/10.1002/mrm.10188

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of surface treatment on diffusion and domain formation in supported lipid bilayers.

Supported lipid bilayers are widely used as model systems due to their robustness. Due to the solid support, the properties of supported lipid bilayers are different from those of freestanding bilayers. In this article, we examine whether different surface treatments affect the properties of supported lipid bilayers. It will be shown that depending on the treatment method, the diffusion of the lipids can be adjusted approximately threefold without altering the composition. Additionally, as the bilayer-support interaction decreases, it becomes easier to form coexisting liquid-ordered and liquid-disordered domains. The physical/chemical alterations that result from the different treatment methods will be discussed.

Diffusion↗

An early example of evidence-based medicine: hypoxemia due to nitrous oxide.

Diffusion anoxia. By Bernard Raymond Fink. Anesthesiology 1955; 16:511-14. In 1955, Dr. Bernard Raymond Fink published his findings that described the mechanism by which hypoxemia occurred when nitrous oxide-oxygen anesthesia was discontinued and room air breathing commenced. Using an ear oximeter and brachial artery blood gases, he measured oxygen saturation in eight healthy patients who had received 75% nitrous oxide-25% oxygen for gynecologic surgery. He showed that oxygen saturation decreased from 5% to 10% and often reached a value below 90% when the patient began room air breathing after the nitrous oxide-oxygen was discontinued. The effect was seen over a 10-min period. He concluded that "anoxia arises because the outward diffusion of nitrous oxide lowers the alveolar partial pressure of oxygen." This phenomenon can become a causative factor of cardiac arrest in patients with impaired pulmonary or cardiac reserves.

Diffusion↗