Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68Linked to original sources

Drug release from acrylic polymers via channels and cracks: in vitro studies with hydrocortisone.

Release of hydrocortisone sodium succinate from acrylic resin was found to occur readily on elution in water at 37 degrees C. Increasing the degree of hydration of the acrylic resin by the addition of hydroxyethyl methacrylate impaired rather than enhanced the release of drug. The mechanism for the release of drug is believed to be surface release and drug dissolution into and diffusion via cracks and channels which are formed by incorporation of the drug, producing a 'drug-modified polymer'. Diffusion through the polymer matrix is believed to be insignificant. The results obtained are discussed in relation to this proposed model for drug release. A simple method for the manufacture of the core of an intra-oral insert capable of delivering drugs with MW greater than 400 for systemic and topical oral drug delivery is described.

Acrylic Resins↗

Effect of packing types on the dimensional accuracy of denture base resin cured by the conventional cycle in relation to post-pressing times.

This study investigated the dimensional stability of denture bases influenced by packing methods, in relation to post-pressing times, in the Clássico acrylic resin which was prepared according to manufacturer recommendations. Forty maxillary wax bases were made and randomly assigned into 2 groups of 20 specimens each according to the conventional and RS system packing methods. In each method, the specimens were subdivided into immediate, 6, 12 and 24 h post-pressing times. The dough of the acrylic resin was packed in metallic flasks and processed in a water bath curing cycle at 74 masculine C for 9 h. After cooling at room temperature, the bases were removed from the flasks, finished and fixed on stone casts with instantaneous adhesive. The resin base-stone cast sets were transversally sectioned into 3 sections and the base-stone gap measured at 5 points in each section. The data were submitted to ANOVA and Tukey's test, which showed that the RS system had a smaller base distortion compared to conventional packing, with the exception of the 24-h post-pressing time. There was a statistically significant difference between the packing methods only in section C (posterior palatal zone). In the conventional packing method, the immediate and 6 h times demonstrated values with no statistically significant difference between them, as well as between the 12 and 24 h post-pressing times.

Acrylic Resins↗

Reconstruction of cranial bone defects using alloplastic implants produced from a stereolithographically-generated cranial model.

Larger cranial bone defects can cause cranial disfigurement as well as potential mechanical brain trauma. Conventionally pre-fabricated acrylic cranioplasty implants require complicated procedures and result in potential dimensional and contour inaccuracies. The development of stereolithographic techniques for generating acrylic resin skull models allows the pre-fabrication of custom acrylic resin cranial implants with greater clinical predictability.

Craniocerebral Trauma↗

A new technique for making occlusal devices.

This procedure has an application to all types of occlusal devices. It is a novel combination of hard and soft acrylic resin. The outer shell of hard resin takes the abuse of the opposing occlusion. The thin well-controlled lining of soft resin makes it easier to seat and more comfortable to wear yet is thin enough that the entire device serves as if it were made entirely of hard acrylic resin. The detailed directions for the entire procedure make it possible to fabricate these novel devices without error.

Acrylic Resins↗

Distortions in indexing methods and investing media for soldering and remount procedures.

A three-dimensional distortion analysis was made of seven indexing-investment systems and six indexing-remount systems. Measurements were made to within +/- 0.005 mm with a Nikon Profile Projector and a linear variable differential transformer (LVDT); distortions (linear and rotational) were calculated by means of a PDP 11/40 computer system. Mean vector displacements, square root deltaX2 + deltaY2 + deltaZ2, were calculated, and a statistical evaluation of the data was completed. The results of the study indicate: 1. The zinc oxide-eugenol (ZOE) indexing-investment system produced a narrower range and a significantly smaller mean distortion than the other six indexing-investment systems. 2. The ZOE-stone remount technique showed significantly less distortion than the ZOE-low-fusing metal or the ZOE-acrylic resin techniques. 3. The polyether-stone remount technique demonstrated significantly less distortion than either the polyether-low-fusing metal or the polyether-acrylic resin system. 4. The polyether-stone remount system was not significantly different from the ZOE-low-fusing metal system. 5. The ZOE-stone remount technique demonstrated a smaller range of distortions, but those distortions were not significantly different from those of the polyether-stone remount technique.

Acrylic Resins↗

Dynamic viscoelastic properties of processed soft denture liners: Part I--Initial properties.

This research evaluated the dynamic viscoelastic properties of 12 laboratory-processed soft denture liners. Specimens, 1.4 x 3 x 40 mm, were prepared according to the manufacturer's instructions. Five specimens of each material were tested under applied strain frequencies of 1, 5, or 10 Hz and temperatures of 23 degrees C and 37 degrees C. The values at 37 degrees C and 1 Hz were judged most important because they closely approximate the service environment; therefore material comparisons were made for these conditions. Samples were tested with a custom-made dynamic viscoelastometer. The statistical significance of the results was tested by ANOVA and Scheffe's intervals test. Large differences in the storage modulus (elastic stiffness) were found. One acrylic resin, Verno-Soft, showed significantly higher storage moduli than the other materials. The viscous behavior of the materials was reflected by the loss modulus; here large differences were also found. Verno-Soft again exhibited much higher values than all of the other materials. Three other acrylic resins (Super Soft, Soft-Pak, and Justi Soft) also showed significantly higher loss moduli than the other materials. Significant differences were found in the damping factor between many of the materials. Most of the acrylic and vinyl resins had higher damping factors than the silicone and polyphosphazine rubbers. The values of the storage moduli, loss moduli, and the damping factor were affected by temperature and by applied strain frequency with some materials.

Acrylic Resins↗

The orbital shell: an aid in positioning the ocular component and verifying margin contours for oculofacial prostheses.

The correct location of the orientation (conversational gaze) of the ocular component is vital to esthetically pleasing oculofacial prostheses. This location should be verified before time and energy are spent on sculpturing the oculofacial prosthesis. A technique is described that uses a clear acrylic resin shell as a matrix and Play-doh material as a support medium to position and support the ocular component to verify the orientation. In addition, the thin acrylic resin shell can be used to refine border inaccuracies that may exist clinically.

Acrylic Resins↗

Fibronectin on prosthetic denture fabrication.

It is well known that fibronectin adheres to various oral bacteria and shows affinity to various components. Thus the existence fibronectin which is present in the salivary flow, acquired pellicle and dental plaque, was investigated in used acrylic resin dentures with a direct immunohistochemical fluorescent technique using antihuman fibronectin goat serum which was labeled with fluorescein isothiocyanate (FITC). It was found that fibronectin frequently was present on the surface of acrylic resin dentures.

Acrylic Resins↗

Resin pattern material with low polymerization shrinkage.

PURPOSE: The purpose of this study was to develop a material with low polymerization shrinkage for resin patterns to improve the fit of a long superstructure to implants. MATERIALS AND METHODS: Three different chemical substances were added at 1, 2, 3, 5, 10, and 20 wt% to the liquid component of a self-curing acrylic resin. Specimens for measuring shrinkage during self curing were prepared in a metal mold that took the form of a conical cavity with slightly tapered walls. The specimens were prepared using three different methods: (1) a brush-on technique, (2) an injection method, and (3) an injection-press method. The percentage of linear shrinkage was calculated from the protrusion of the specimen from the bottom of the cavity. RESULTS: The injection-press method and the brush-on method gave the lowest polymerization shrinkage results (P < 0.05). The standard deviation of the former method was smaller than that of the latter. The linear shrinkage in the injection-press method decreased with the increase of the powder-to-liquid ratio (P < 0.05). All three additives reduced shrinkage to about 1/3 of the shrinkage of the basic resin using the injection-press method and a 2.00:1.00 powder-to-liquid ratio. CONCLUSION: The addition of three different chemical substances to liquid reduces linear shrinkage to about 1/3 of the shrinkage of the original self-curing acrylic resin.

Acrylic Resins↗

Effect of contaminants on the adhesion of light-bodied silicones to putty silicones in putty-wash impression technique.

This study was concerned with the adhesion of a light-bodied silicone to a putty silicone in a putty-wash impression technique when the preliminary putty impression was contaminated with human saliva or residues from acrylic resins used in the fabrication of provisional restorations by direct technique. Data indicated that condensation and addition silicones differed in their susceptibility toward the tested contaminants. Salivary contamination and chemical residues from the autopolymerizing acrylic resins weakened the bond strength and caused adhesive failure dependent upon the type of silicone impression material used.

Acrylic Resins↗

Extraoral retention of an obturator prosthesis.

In this study, a technique is described by which large obturators can be retained with an acrylic resin head plate. The technique entails attaching the prosthesis to an acrylic resin plate with a 2-mm-diameter wire and then attaching the plate to the patient's forehead with skin tape.

Aged↗

The influence of occlusal surface material on peak masticatory forces using osseointegrated implant-supported prostheses.

Masticatory forces associated with porcelain and acrylic resin occlusal surfaces on osseointegrated implant-supported prostheses opposing natural teeth were studied in five healthy subjects. A three-channel electronic force transducer carrying a fixed prosthesis with either acrylic resin or porcelain occlusal surfaces and balanced articulation was used to record masticatory forces while the subjects chewed various foods. It was found that mean peak masticatory forces varied considerably from subject to subject but were consistent within each subject. No differences related to tooth material could be detected in the load rates. Forces directed away from the implants were noted in all subjects.

Acrylic Resins↗

Direct-indirect heat-cured occlusal splint fabrication for a patient with limited mouth opening.

There are several conditions that can cause limited mouth opening. Recent literature on some of the most common conditions is discussed in this article. The difficulty in making alginate impressions may prevent indirect laboratory fabrication of heat-cured occlusal splints for patients with limited mouth opening. This article presents a combined direct-indirect technique for fabricating a heat-cured laboratory-processed maxillary occlusal splint in a case where making a mandibular alginate impression would have been extremely difficult. An extra-hard baseplate wax interocclusal record was used as a template for occlusal splint fabrication. The wax record was fitted to the maxillary side, then the mandible was gently manipulated to provide light imprints of the opposing teeth. The wax record provided the therapeutic vertical dimension as well as the therapeutic interocclusal relationship for the occlusal splint. The wax record was seated and sealed to the maxillary cast and modified on the palatal and facial aspects for the appropriate splint shape. The splint was processed using clear heat-cured acrylic resin. It required minimum adjustment on delivery. This procedure spared the patient from having a lower impression, which would have been required for the traditional laboratory-made occlusal splint. Increased adjustment time and excessive exposure to unoccurred acrylic resin, which would have occurred with direct intraoral fabrication, were minimized or eliminated using this technique.

Acrylic Resins↗

Effect of etching and sandblasting on bond strength to sintered porcelain of unfilled resin.

This study determined the bond strength of an unfilled resin joined to a feldspathic porcelain for the purpose of evaluating the retentive performance of the prepared material surfaces. Porcelain disks (VMK 68 dentin) were either air abraded with alumina (AAA) or etched with one of the following five etchants: (1) ammonium hydrogen bifluoride (AHB); (2) acidulated phosphate fluoride (APF); (3) hydrofluoric acid (HFA); (4) phosphoric acid (PHA); and (5) sulfuric acid-hydrofluoric acid (SHF). Specimens ground with abrasive paper were also used as controls. After surface preparation, the two different sized porcelain disks were bonded together with a methyl methacrylate-based resin initiated with tri-n-butylborane (MMA-TBB resin). Shear bond strengths were determined both before and after thermocycling. Before the thermocycling, the greatest bond strengths (21.3 and 23.7 MPa) were generated with the use of the SHF and HFA agents, followed by the AHB agent (18.4 MPa). Reduction in bond strength after thermocycling was significant for all groups, although the SHF- and HFA-treated groups exhibited bond strengths greater than 15 MPa even after the thermocycling. The results indicated the effectiveness of the SHF- or HFA-etching for retaining the acrylic resin to the porcelain. However, ageing testing also revealed insufficient retentive characteristics of the acrylic resin by etching alone.

Acid Etching, Dental↗

Early detection of dens evaginatus appearing on the premolars and clinical management: histological study.

A review of the methods for the prevention of central cusp fracture is presented, with a case of central cusp protection of a premolar by self-curing acrylic resin by early detection. The anomalous tooth was extracted for histological observation. Closure of the pulpal horn, could be accomplished by early detection and adequate treatment for the central cusp fracture of premolars. In this case, if the gradual attrition of a central cusp were not possible, a protecting the cusp using a self-curing acrylic resin would be an effective form of treatment.

Acrylic Resins↗

Effect of 4-MET on bond strength and penetration of monomers into enamel.

The effect of 4-[2-(methacryloyloxy)ethoxycarbonyl]phthalic acid (4-MET) in self-curing acrylic resin initiated by BPO-amine on the bond strength to etched enamel was studied. Scanning electron microscopic (SEM) observations of resin-enamel interfaces were carried out to elucidate the bonding mechanism and the effect of 4-MET on the adhesion. 4-MET, which has both hydrophilic and hydrophobic groups, increased the bond strength of self-curing acrylic resin to etched enamel and improved the bonding stability. SEM pictures strongly suggested that 4-MET promoted interpenetration of monomers into enamel prism peripheries and their polymerization therein resulted in excellent adhesion to etched enamel.

Acid Etching, Dental↗

Personal identification using dental prostheses.

A personal identity mark may be added to a metal or an acrylic resin prosthesis. The importance of this technique, particularly in terms of forensic investigation and identification, should make it a compulsory dental procedure. Where metal is involved, engraving is the most desirable method of marking. The heat resistance of various labeling materials indicates that an acrylic resin prosthesis should contain a marked, heat resistant material together with a mark clearly visible from the denture surface.

Acrylic Resins↗

A clinical evaluation of materials for interocclusal registration in centric relation.

Four techniques for interocclusal registrations of centric relation based on materials or combinations of materials usually utilized were tested by means of mounting of casts for a patient with partial lower edentulousness, without a free end saddle. To ensure the correct position of centric relation a Lucia jig was utilized. The following conditions for the record of posterior section were tested: registrations with wax, wax plus zinc oxide-eugenol paste, wax plus Duralay acrylic resin, and condensation silicone (putty). The evaluation was made by the measure of vertical distance between reference points in the base of the casts and calculation of variations occurring with each material. The combinations of wax plus zinc oxide-eugenol paste and wax plus Duralay acrylic resin showed the smallest variations in centric relation position.

Acrylic Resins↗