Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Solid-phase extraction and gas chromatography-mass spectrometry determination of kaempferol and quercetin in human urine after consumption of Ginkgo biloba tablets.

A method was developed for the quantification of the flavonoids quercetin and kaempferol in human urine using a solid-phase extraction procedure followed by gas chromatography-mass spectrometry. Deuterated internal standards of the analytes were spiked into the samples prior to extraction. The limit of detection of the method was ca. 10 pg on column and precision of the method for quantification in a sample of urine was +/-9.40% for kaempferol and +/-7.34% for quercetin (n = 6). The levels of quercetin and kaempferol found in urine samples were only a small fraction of the amount ingested. The treatment of urine samples with beta-glucuronidase markedly increased the levels of flavonoids detected, supporting the view that kaempferol and quercetin are eliminated in the urine as glucuronides.

Calibration↗

Stereoselective determination of pyridoglutethimide enantiomers in serum with a chiral cellulose-based high-performance liquid chromatographic column using solid phase extraction and UV detection.

A sensitive method for the separation and determination of R(+)- and S(-) enantiomers of pyridoglutehimide in serum by high performance liquid chromatography (HPLC) with UV detection was developed. The assay involves the use of a solid-phase extraction for serum sample clean-up prior to HPLC analysis using a C18 Bond-Elute column. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OD-R, 250 x 4.6 mm I.D.) under isocratic conditions using a mobile phase of 25:75 v/v acetonitrile-0.3 M aqueous sodium perchlorate (pH 6.2 adjusted with perchloric acid) at a flow rate of 0.8 ml/min. Recoveries for R(+)- and S(-)-pyridoglutethimide enantiomers were in the range 86-91% at 300-900 ng/ml level. Intra-day and inter-day precision calculated as %R.S.D. were in the ranges of 2.9-3.9 and 1.5-4.7% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percentage error were in the ranges of 1.9-3.3 and 1.5-3.9% for both enantiomers, respectively. Linear calibration curves in the concentration ranges of 100-1500 ng/ml for each enantiomer show correlation coefficient (r) of more than 0.9995. The limit of quantification (LOQ) of each enantiomer was 100 ng/ml using 1 ml of serum. The detection limit (LOD) for each enantiomer in serum using a UV detection set at 257 nm was 50 ng/ml (S/N = 2).

Aminoglutethimide↗

Perchlorate analysis using solid-phase extraction cartridges.

Perchlorate is a compound of increasing concern as an environmental contaminant and is being regulated at increasingly stringent levels. Reliable methods are needed to consistently analyze perchlorate at low concentration levels. This research investigates the use of solid-phase extraction cartridges as an alternative to large-volume injection loops to achieve low-level (microg/L level) perchlorate quantitation. The method involves commercially available strong anion exchange (SAX) cartridges. Water samples are filtered (100 to 1000 mL) using the cartridge, which removes the perchlorate from the solution by anion exchange. Then, after the desired volume is filtered, the perchlorate is extracted using 4 mL of 1% NaOH. In addition, a cleanup method is developed to remove competing anions (chloride, sulfate, and carbonate) that are often found in environmental samples. Analyses are performed with an ion chromatograph using a 10-microL injection loop, yielding a perchlorate method detection limit (MDL) of 210 microg/L. One-liter volumes of a 2-microg/L perchlorate spiked deionized water solution are filtered with SAX SPE. Following extraction and analysis, an MDL of 0.82 microg/L is obtained, comparable to that found for 1-mL injection loop systems (reported as low as 0.53 microg/L). MDL studies are then conducted on perchlorate-amended groundwater (solution concentration of 70 microg/L) and surface water (solution concentration of 10 microg/L) using a filtration volume of 200 mL. The MDLs are 6.7 microg/L for the groundwater and 2.4 microg/L for the surface water.

Chromatography, Ion Exchange↗

Determination of isopropyl-9H-thioxanthen-9-one in packaged beverages by solid-phase extraction clean-up and liquid chromatography with tandem mass spectrometry detection.

A simple method was developed and validated for the trace determination of 2-isopropylthioxanthone (ITX) in packaged drinks. Samples were extracted from the food matrix using acetonitrile:water (60:40, v/v), and further subjected to clean-up and preconcentration using solid-phase extraction prior to analysis by liquid chromatography-tandem mass spectrometry using multiple reaction monitoring (MRM) mode. The use of 2-isopropyl-[(2)H7]thioxanthen-9-one was incorporated into the method as an internal standard. Excellent 3-day interday precision data (RSD 0.72%, n=10), and intraday precision data (RSD 0.52%, n=10) were obtained on a 0.10 microg/L standard solution. Spiked samples (n=8) were used to gauge the accuracy of the method at the concentration levels of 2.5, 100, and 500 microg/kg in food; recoveries ranged from 97.0 to 103.0%. These excellent validation data suggest the exciting possibility of using this method for the determination of low levels of ITX migrating from printed food packaging materials into beverages with a method quantitation limit of 0.50 microg/kg. For the first time, analysis on a range of milk, juice, tea and yoghurt drinks, as well as their respective food packaging materials were performed for comparative studies on their ITX content.

Beverages↗

The application of solid phase extraction to the analysis of tobacco-specific nitrosamines.

A new isolation and separation method has been developed for the alkaloid-related nitrosamines in tobacco, called tobacco-specific nitrosamines (TSNA). The improved isolation procedure involves the extraction by sonication of TSNA from cured tobacco with toluene and an aqueous citrate buffer solution, while purification is achieved by solid phase extraction on small silica cartridges. Interfering extract materials are eluted from the silica cartridges with the toluene and a chloroform-methylene chloride solvent, while subsequent elution with chloroform yields the TSNA in a purified fraction. Gas chromatographic analyses on an SE-54-coated glass capillary column and detection by a nitrogen-phosphorous detector produce very good data on the four TSNAs, which include N-nitrosanatabine (NATB), N-nitrosoanabasine (NAB), 4-(N-methyl-N-nitrosamino)-1-(3-pyridyl)-1-butanone (called NNK), and N-nitrosonornicotine (NNN). The method is shown to be quantitative, reproducible, and applicable to the determination of TSNA in various tobacco samples, such as stems and lamina of cured tobacco leaves, as well as to smokeless tobacco.

Chromatography, Gas↗

Solid phase extraction for the confirmation of results in polar pesticides residue analysis by HPTLC.

HPTLC is a convenient method for confirming the presence and identification of pesticide residues following gas chromatographic analysis of sample solutions obtained by clean-up according to the Deutsche Forschungsgemeinschaft multiresidue method S 19. For several crops, however, the polar eluates 4 and 5 obtained from the small silica gel column are abounding with co-extractives which interfere with HPTLC determination and also with GLC in some cases. They are effectively removed by solid phase extraction on a small aminopropyl cartridge, using a tertbutyl methyl ether/methanol (99 + 1) mixture as the eluant. The recoveries for 28 polar pesticides were not adversely affected.

Cholinesterase Inhibitors↗

Selectivity of solid-phase extraction phases in the determination of biodegradation products.

The extraction techniques connected with gas chromatography were used to describe quantitatively and qualitatively the biodegradation process. We investigated the biodegradation of hydrocarbons and non-ionic surfactants. Solid-phase extraction (SPE) and liquid-liquid extraction were used for the isolation of the non-degraded compounds and their degradation products. The selectivity of SPE has a significant influence on the isolation and preconcentration of organic compounds from water.

Biodegradation, Environmental↗

Effective sorbents for solid-phase extraction in the analysis of quinolones in animal tissues by capillary electrophoresis.

In this work, several commercial sorbents (Zorbax C18, Bond Elut C18, Isolute ENV+, Oasis HLB, Oasis MAX, SDB-RPS, and MPC-SD) were compared for the solid-phase extraction of the series of quinolones regulated by the European Community in chicken tissues in order to establish a method for the determination of this series of quinolones by capillary electrophoresis and diode array detection. Sorbents were chosen in order to achieve maximum recoveries and optimal clean-up efficiency. Better results were obtained using SDB-RPS and Oasis MAX which would provide suitable limits of detection, below of the maximum residue limits (MRLs) regulated.

Animals↗

Spectrophotometric determination of chromium with diphenylcarbazide in the presence of vanadium, molybdenum, and iron after separation by solid-phase extraction.

A method has been developed for the determination of chromium in presence of V(V), Mo(VI), and Fe(III). The effects of interferences were evaluated by using the apparent content curves method, and their separation was performed by solid-phase extraction with an anionic exchanger. The sample-treatment conditions and the influence of the sample conductivity were studied. Tolerance limits were established, and the proposed procedure was used to determine chromium in certified samples and for speciation of chromium in waste water. Our results were always in agreement with the theoretical content.

Journal Article↗

Solid phase extraction method for rapid isolation and clean-up of some synthetic pyrethroid insecticides from human urine and plasma.

A simple and rapid method for the isolation of seven synthetic pyrethroid insecticides (methothrin, fenpropathrin, cyhalothrin, permethrin, cypermethrin, fenvalerate, deltamethrin) with a solid phase extraction (SPE), utilizing Sep-Pak C18 cartridges, from human urine and plasma is presented. The detection of the insecticides was performed using a wide bore capillary gas chromatograph (GC) with flame ionization detection (FID). The insecticide-containing samples mixed with 70% methanol were directly applied to the cartridges and eluted with 2 ml chloroform. The recoveries using the cartridges were between 90-102% for urine and 81-93% for plasma. Mixing samples with 70% methanol prior to extraction, seems very useful for the screening of synthetic pyrethroid insecticides.

Chromatography, Gas↗

Determination of amphotericin B in cerebrospinal fluid by solid-phase extraction and liquid chromatography.

A highly sensitive and reproducible liquid chromatography (LC) method for the determination of Amphotericin B in cerebrospinal fluid has been developed and validated. This LC-based method involves using nystatin as an internal standard and solid-phase extraction for sample preparation, followed by reversed-phase separation monitored by absorbance at 410 nm. The method has a limit of quantification of less than 1 ng ml-1 and excellent precision and accuracy, with both percentage relative standard deviation and percentage relative error less than 10%. The established linearity range was 1-10 ng ml-1 (r2 > 0.99). The extraction recovery of Amphotericin B from the cerebrospinal fluid is higher than 90% over the entire linear range. The method has been successfully employed for studying the penetration of Amphotericin B into the central nervous system in dogs and human.

Amphotericin B↗

Determination of important odor-active aldehydes of wine through gas chromatography-mass spectrometry of their O-(2,3,4,5,6-pentafluorobenzyl)oximes formed directly in the solid phase extraction cartridge used for selective isolation.

A method for the quantitative determination of octanal, nonanal, decanal, (E)-2-nonenal and (E, Z)-2,6-nonadienal in wine has been developed. In the proposed method, 200 ml of wine percolate through a solid phase extraction (SPE) cartridge packed with 200 mg of LiChrolut EN resins. The interferences are eluted with 60 ml of an aqueous solution containing 40% of methanol and 1% of NaHCO3. In the same SPE cartridge, the corresponding O-(2,3,4,5,6-pentafluorobenzyl)oximes are formed by letting percolate 2 ml of the reagent solution (5 mg ml(-1)). At room temperature the derivatization goes to completion in 15 min. The derivatives are eluted with 2 ml of dichloromethane, and the extract is concentrated and then analyzed by gas chromatography-mass spectrometry (GC-MS). The percentage of recovery in the isolation process is better than 90% in all cases with the exception of octanal, and is independent of the wine studied. In the cases of octanal, nonanal and decanal, the detection limits of the method are determined by the contamination levels of the reagent itself, and vary between 160 and 380 ng l(-1). For (E)-2-nonenal and (E, Z)-2,6-nonadienal, the detection limits were 12 and 20 and ng l(-1), respectively. The linearity of the method upheld until 10 microg l(-1) and was satisfactory in all cases. The reproducibility of the method is independent of the concentration and ranges from 30 to 190 ng (l(-1). The method has been applied to the analysis of these components in several wine samples. With the exception of (E, Z)-2,6-nonadienal, all the components can reach concentrations above their corresponding odor threshold values.

Aldehydes↗

Determination of the new HIV-protease inhibitor atazanavir by liquid chromatography after solid-phase extraction.

An HPLC method previously described for the simultaneous assay of amprenavir, ritonavir, indinavir, saquinavir, nelfinavir and efavirenz is proposed here for the simultaneous analysis of the new HIV protease inhibitor atazanavir (ATV) in human plasma, by off-line solid-phase extraction (SPE) followed by HPLC coupled with UV-diode array detection. After viral inactivation by heat (60 degrees C for 60 min), plasma (600 microl) with clozapine (internal standard) is diluted 1 + 1 with phosphate buffer pH 7 and subjected to a SPE on a C18 cartridge. Matrix components are eliminated with 2 x 500 microl of a solution of 0.1% H(3)PO(4) neutralised with NaOH to pH 7. ATV is eluted with 3 x 500 microl MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 100 microl MeOH/H(2)O 50/50. A 40 microl volume is injected onto a Nucleosil 100-5 microm C18 AB column. ATV is analysed by UV detection at 201 nm using a gradient elution program with solvents constituted of MeCN and phosphate buffer adjusted to pH 5.14. The mobile phase also contains 0.02% sodium heptanesulfonate, enabling an excellent separation of ATV from the other HIV protease inhibitors (PIs) amprenavir, indinavir, saquinavir, ritonavir, lopinavir, nelfinavir and the non-nucleoside reverse transcriptase inhibitors (NNRTIs) efavirenz and nevirapine. The calibration curves are linear up to 10 microg/ml, with a lower limit of quantification of 0.2 microg/ml. The mean absolute recovery of ATV is 96.4 +/- 3.2%. The method is precise with mean inter-day CVs within 1.1-6.1%, and accurate (range of inter-day deviations +0.3 to +2.3%). The method has been validated and is currently applied to the monitoring of ATV in HIV patients.

Atazanavir Sulfate↗

Determination of ketorolac in human plasma by reversed-phase high-performance liquid chromatography using solid-phase extraction and ultraviolet detection.

An improved high-performance liquid chromatographic method has been developed to measure human plasma concentrations of the analgesic nonsteroidal anti-inflammatory drug ketorolac for use in pharmacokinetic studies. Samples were prepared for analysis by solid-phase extraction using Bond-Elut PH columns, with nearly complete recovery of both ketorolac and the internal standard tolmetin. The two compounds were separated on a Radial-Pak C18 column using a mobile phase consisting of water-acetonitrile-1.0 mol/l dibutylamine phosphate (pH 2.5) (30:20:1) and detected at a UV wavelength of 313 nm. Using only 250 microl of plasma, the standard curve was linear from 0.05 to 10.0 microg/ml.

Adolescent↗

Improved method for the simultaneous determination of proguanil and its metabolites by high-performance liquid chromatography and solid-phase extraction of 100-microl capillary blood samples dried on sampling paper.

An improved method is presented for the determination of proguanil, cycloguanil and 4-chlorophenylbiguanide in 100-microl capillary blood samples applied to sampling paper. This method also utilises a solid-phase extraction technique and high-performance liquid chromatography. Different kinds of sampling paper, such as ion-exchange and cellulose sampling paper were tested. The best elution recovery (70-80%) was obtained after treatment of cellulose sampling paper with a quaternary ammonium compound. The limit of determination was 50 nmol/l for cycloguanil and 4-chlorophenylbiguanide and 125 nmol/l for proguanil using 100 microl capillary blood. The stability of the analytes and elution performance from sampling paper was validated at different temperature and storage time. Venous blood and capillary blood concentrations of proguanil and metabolites were found to be similar.

Antimalarials↗

'High throughput' solid-phase extraction technology and turbo ionspray LC-MS-MS applied to the determination of haloperidol in human plasma.

A quantitative method for the analysis of haloperidol in human plasma is described. Sample clean-up was performed by means of solid-phase extraction using 3M Empore extraction disk plates in the 96-well format, automated with a Canberra Packard pipetting robot. Separation was performed by reversed phase high performance liquid chromatography with turbo ionspray tandem mass spectrometric detection by monitoring the decay of protonated haloperidol of m/z 376 to its fragment at m/z 165, versus the decay of protonated haloperidol-D4 at m/z 380 to its fragment at m/z 169. The validated concentration range was from 0.100 to 50.0 ng ml(-1), with an inaccuracy and overall imprecision below 10% at all concentration levels. Validation results on linearity, specificity, precision, accuracy and stability are shown and are found to be adequate. The average sample preparation time for a batch of 96 samples is approximately 50 min. The chromatographic run time is 3 min. A sample throughput of at least 240 samples per day can be achieved.

Antipsychotic Agents↗

Determination of aflatoxin M1 in milk and milk powder using high-flow solid-phase extraction and liquid chromatography-tandem mass spectrometry.

Animal feeds occasionally have some degree of contamination by Aspergillus spp. Even pasteurized milk at times contains the toxic liver carcinogen aflatoxin M1 (AFM1). Confirmation of its presence is now done with solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC)-fluorescence, using a small enough sample that SPE time is reasonable. In this study 200 mL of milk was extracted using a C18 disk at a flow rate of approximately 100 mL/min and AFM1 quantified by HPLC-tandem mass spectrometry with negative electrospray ionization. The effectiveness and cleanup efficacy of immunoaffinity columns (IAC) was compared with that of Mycosep multifunctional cleanup columns (MFC). Average recovery and detection limits of whole milk and low-fat milk cleaned up by IAC were significantly superior to those obtained with the MFC (78-87% and 0.59-0.66 ng/L, respectively). The new procedure improves extraction speed, sensitivity, and specificity.

Aflatoxin M1↗

On-line solid-phase extraction and fluorescence detection of selected endocrine disrupting chemicals in water by high-performance liquid chromatography.

A high-performance liquid chromatographic method was developed to analyse selected endocrine disrupting chemicals in water by using automated on-line solid-phase extraction with a fluorescence detector. The excitation and emission wavelengths of the fluorescence detector were 230 nm and 290 nm, respectively. The selected endocrine disrupting chemicals include hormone steroids such as estradiol (E2), estriol (E3), ethynylestradiol (EE2), and ethynylestradiol 3-methyl ether (MeEE2) as well as nonylphenols (NP), octylphenols (OP), POE(1-2) nonyl phenol (NPE) and bisphenol A (BP). Three types of on-line cartridges (C18, PLRP-s and PRP-1) were tested to pre-concentrate the endocrine disruptors in deionised water. It was found that the recoveries of these chemicals at 1 microg/L were close to 100% except for 4-octyl phenol and 4-n-nonyl phenol, which had recoveries of about 40% to 80%. The two polymer cartridges (PLRP-s and PRP-1) gave higher recoveries than the C18 cartridges. The addition of methanol at 5% to 10% in water significantly improved the recovery of 4-octyl phenol and 4-n-nonyl phenol. The addition of methanol also led to an improvement in the recovery with C18 cartridges. With the addition of methanol in water samples, these three types of cartridges gave similar recoveries for the chemicals. The detection limits of this method ranged from 20 ng/L to 50 ng/L. A river water sample spiked with these chemicals was analysed using the above method and we found no interference with the peaks of the selected endocrine disrupting chemicals. The recoveries for these chemicals were more than 92% except for 4-NP with a recovery of 61%. This relatively simple method is useful for laboratory studies on the environmental fate of these endocrine disrupting chemicals in water.

Chromatography, High Pressure Liquid↗