Perchlorate analysis using solid-phase extraction cartridges.

Abstract

Perchlorate is a compound of increasing concern as an environmental contaminant and is being regulated at increasingly stringent levels. Reliable methods are needed to consistently analyze perchlorate at low concentration levels. This research investigates the use of solid-phase extraction cartridges as an alternative to large-volume injection loops to achieve low-level (microg/L level) perchlorate quantitation. The method involves commercially available strong anion exchange (SAX) cartridges. Water samples are filtered (100 to 1000 mL) using the cartridge, which removes the perchlorate from the solution by anion exchange. Then, after the desired volume is filtered, the perchlorate is extracted using 4 mL of 1% NaOH. In addition, a cleanup method is developed to remove competing anions (chloride, sulfate, and carbonate) that are often found in environmental samples. Analyses are performed with an ion chromatograph using a 10-microL injection loop, yielding a perchlorate method detection limit (MDL) of 210 microg/L. One-liter volumes of a 2-microg/L perchlorate spiked deionized water solution are filtered with SAX SPE. Following extraction and analysis, an MDL of 0.82 microg/L is obtained, comparable to that found for 1-mL injection loop systems (reported as low as 0.53 microg/L). MDL studies are then conducted on perchlorate-amended groundwater (solution concentration of 70 microg/L) and surface water (solution concentration of 10 microg/L) using a filtration volume of 200 mL. The MDLs are 6.7 microg/L for the groundwater and 2.4 microg/L for the surface water.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Victor F Medina, Steven L Larson, Barbara Extine, Anthony Bednar. 2005. Perchlorate analysis using solid-phase extraction cartridges.. https://doi.org/10.1093/chromsci%2F43.4.195

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mathematical modeling of elution curves for a protein mixture in ion exchange chromatography and for the optimal selection of operational conditions.

Elution curves in ionic exchange chromatography (IEC) for a three-protein mixture (alpha-lactoalbumin, ovalbumin, and beta-lactoglobulin), carried out under different flow rates and ionic strength conditions, were simulated using two different mathematical models. These models were the Plate Model and the more fundamentally based Rate Model. Relatively low protein concentrations were used to avoid protein-protein interactions. Simulated elution curves were compared with experimental data not used for parameter identification. Deviation between experimental data and the simulated curves using the Plate Model was less than 0.0189 (absorbance units); a slightly higher deviation [0.0252 (absorbance units)] was obtained when the Rate Model was used. A cost function was built that included the effect of the different production stages, namely fermentation, purification, and concentration. These considered the effect on the performance of IEC; yield, purity, concentration and the time needed to accomplish the separation. Operational conditions in the IEC such as flow rate, ionic strength gradient and the operational time can be selected using this model in order to find the minimum cost for the protein production process depending on the characteristics of the final product desired such as purity and yield. This cost function was successfully used for the selection of the operational conditions as well as the fraction of the product to be collected (peak cutting) in IEC. It can be used for protein products with different characteristics and qualities, such as purity and yield, by choosing the appropriate parameters.

Chromatography, Ion Exchange↗

Monitoring the photochemical degradation of triclosan in wastewater by UV light and sunlight using solid-phase microextraction.

Photo solid-phase microextraction (photo-SPME) is applied for the first time to study the photochemical behavior of an emerging pollutant, triclosan, in real contaminated wastewater samples using a solar simulator. In this study, water samples are extracted by SPME and then, the fiber coating is irradiated for a selected time. This on-fiber procedure, so-called photo-SPME, followed by gas chromatography-mass spectrometry makes it possible to study photodegradation kinetics and the generation of byproducts. Several photoproducts were identified in the real samples including the 2,8-dichlorodibenzo-p-dioxin, dichlorophenols and a compound tentatively identified as other DCDD congener or a dichlorohydroxydibenzofuran. Accordingly, it was possible to postulate main photodegradation mechanisms. Photo-SPME demonstrated slower kinetics in wastewater than in spiked ultrapure water probably due to the presence of dissolved organic matter. This technique was extensively compared with conventional aqueous photodegradation showing high similarity. The influence of pH on the triclosan photolysis and on the triclosan-dioxin conversion was also investigated in wastewater. Photodegradation of triclosan and formation of 2,8-DCDD occurred independently of sample pH. This study represents an advance in the use of photo-SPME to understand the photochemical fate of environmental organic pollutants and demonstrates its clear advantages with real samples.

Chromatography, Ion Exchange↗

A design for automatic preparation of highly concentrated 188Re-perrhenate solutions.

Rhenium-188 is extremely suitable for the radiotherapy of balloon dilation for the coronary artery restenosis. To satisfy the need of highly concentrated (188)Re-perrhenate for the clinical applications, we designed an apparatus to achieve the purpose of concentrating (188)Re-perrhenate solution. This apparatus comprised of a concentrator, a control box and a computer with an automatic control program. A column of cation-exchange resin in Ag(+) form and an anion-exchange column in series were used in the concentration procedure. More than 90% of (188)Re isotope in the original solution could be collected with 1mL of 0.9% NaCl solution added to collect the (188)Re adsorbed in the column in this final process (90.7+/-2.2%, n=15). We also found that the radiochemical purity in the final solution remained unchanged (100%). The designed process could automatically increase the quality and efficiency of the production of highly concentrated rhenium-188 solution, and could also reduce the radiation dose absorbed by the operator.

Chromatography, Ion Exchange↗