Search PubMedSearch

SEARCH · Search PubMed

Results for “Multiple Organ Failure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

669 records · Page 6Linked to original sources

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2 - V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12‑lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2 - V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12‑lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000 Hz. In the standard recording, the digital PBL was calculated as V2 - V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008 mV). CONCLUSIONS: Physical acquisition of the V2 - V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Future promise, current clinical ambiguity: a systematic review of machine learning algorithm outputs predicting risk of cardiovascular disease.

OBJECTIVE: To examine whether the outputs of machine learning algorithms designed to predict risk of cardiovascular disease (CVD) address known deficiencies of the Framingham Risk Score (FRS) and improve risk estimates. METHODS: For this critical review, Medline, Embase and IEEE were searched from inception to 1 January 2025. Included were studies describing machine learning algorithms designed to specifically compare output of cardiovascular risk assessment with the FRS. Commentaries, letters, unpublished work or non-peer-reviewed papers were excluded.Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, two reviewers screened titles and abstracts independently, then populated a purpose-built data extraction form. A subsequent qualitative thematic analysis focused on algorithms' strengths, added value, potential harms, unintended consequences and equity implications.The main outcome assessed was whether, among healthy adults, the algorithm improved CVD risk prediction relative to the FRS. RESULTS: Of 707 studies retrieved, 29 met inclusion criteria. 23 reported improved predictive ability relative to the FRS. Most datasets and/or medical records used included sociodemographic predictors of CVD not included among FRS inputs. Some added costly diagnostic tests like CT angiography to FRS screening indicators. When they were defined, inputs and outcomes such as hypertension or myocardial infarction did not always adhere to FRS values. Statistical significance was generally taken as a proxy for clinical significance. Some algorithms overestimated the number at risk compared with the FRS without discussing whether that larger proportion might be at risk of overdiagnosis rather than CVD, while a few decreased the proportion found to be at risk. CONCLUSIONS: Use of artificial intelligence to improve accuracy of risk assessment for CVD demonstrates the technological capacity to merge known sociodemographic predictors with biologic variables and examine non-linear interactions among these. Still needed to achieve patient benefit is clinical insight, adherence to screening principles and cost-benefit assessment of inputs selected.

Humans

Genome-wide scans reveal candidate genes associated with wing morph differentiation in Tetrix japonica.

Wing dimorphism is an important dispersal-related trait in insects, but its genomic basis remains poorly understood in pygmy grasshoppers. Here, we integrated genome-wide single-nucleotide polymorphism (SNP) analyses, population structure inference, selection scans, and functional annotation to investigate genomic differentiation between long- and short-winged Tetrix japonica. Principal component analysis (PCA), ADMIXTURE, and phylogenetic analyses revealed weak genome-wide separation between morphs, indicating differentiation on a largely shared genetic background. Genome-wide scans based on the fixation index (FST), nucleotide diversity ratios, and Tajima's D, using 50-kb non-overlapping windows and empirical top-5% outlier thresholds, identified multiple candidate regions across seven chromosomes. The broader long- and short-winged candidate sets spanned 9.35 Mb and 9.37 Mb and directly overlapped 82 and 77 genes, respectively. Candidate genes were associated with signaling/hormone regulation, membrane transport, metabolism, cytoskeletal organization, extracellular matrix structure, and development. Short-winged candidate genes were significantly enriched for ABC-type transporter activity and ATP hydrolysis activity. Because all individuals originated from a single laboratory-maintained population with weak genome-wide structure, these regions should be regarded as candidate loci from a screening-stage analysis that require validation in independent populations and by functional assays, rather than as confirmed targets of selection.

Animals

Effects of Progressive Inspiratory Muscle Training on Lung Volume and Respiratory Strength in Patients With Pre-Dialysis Chronic Kidney Disease.

INTRODUCTION: Chronic kidney disease can present changes in thoracic cavity volume and respiratory muscle weakness, even in the pre-dialysis stage. However, there is little evidence on the effects of inspiratory muscle training in these patients. METHODS: This was a randomized clinical trial which comprised patients with Chronic Kidney Disease in stages 3, 4, and 5 undergoing conservative treatment, allocated experimental group (EG) with progressive loading (up to 50% of maximal inspiratory pressure [MIP]) and control group (CG) with a fixed load (5 cmH2O) and no load progression performed daily for 8&#xa0;weeks. The outcomes assessed were thoracic cavity volumes, as measured by optoelectronic plethysmography, and inspiratory and expiratory respiratory muscle strength. RESULTS: A total of 30 patients completed the study. All volumes significantly increased at the end of the protocol with a large effect size, but only the pulmonary thoracic cavity volume showed a significant interaction (F&#xa0;=&#xa0;3.698; p&#xa0;=&#xa0;0.042). There was an increase in inspiratory muscle strength in the EG (73.88-90.35&#xa0;cmH2O; p&#xa0;<&#xa0;0.001) and in the CG (70.85-86.92&#xa0;cmH2O; p&#xa0;=&#xa0;0.001), as well as in expiratory muscle strength in the EG (97.71-108.53&#xa0;cmH2O; p&#xa0;=&#xa0;0.001) and in the CG (80.69-94.77&#xa0;cmH2O; p&#xa0;=&#xa0;0.004). CONCLUSION: Daily IMT increased thoracoabdominal volumes, particularly pulmonary rib cage volume in the progressive-load group, as well as respiratory muscle strength in patients with pre-dialysis CKD. However, progressive-load IMT was not superior to minimal-load training.

Humans

Cationic porphyrin covalent organic framework reinforced hydroxypropyl methylcellulose films for photodynamic-photothermal sterilization and food preservation.

Microbial contamination in food necessitates effective antimicrobial packaging. While cellulose-based packaging materials suffer from limited antimicrobial efficacy, lack of active functionality, and susceptibility to inducing microbial resistance. To address these challenges, this study synthesized a cationic porphyrin-based covalent organic framework (Por-ICOF) as a multimodal photosensitizer. Por-ICOF was uniformly dispersed via non-covalent interaction within hydroxypropyl methylcellulose (HPMC), creating an HPMC/Por-ICOF composite film. This integration enhanced mechanical strength (increased by 26%), hydrophobicity (WCA 71&#xb0;), and gas barrier properties (OP reduced by 42%, WVP reduced by 36%). Under visible light, the HPMC/Por ICOF film superior absorption generated reactive oxygen species (ROS) and photothermal effects, inactivating 99.2% of Escherichia coli and 99.95% of Staphylococcus aureus within 20&#xa0;min. The composite film exhibited excellent biocompatibility and effectively extended the shelf life of strawberries. This cationic modification strategy for cellulose-based films offers a novel avenue for the design of high-performance antimicrobial food packaging materials.

Food Preservation

Respiratory-onset peripartum cardiomyopathy: a systematic review of diagnostic pitfalls and clinical outcomes.

INTRODUCTION: Peripartum cardiomyopathy (PPCM) may initially present with prominent respiratory symptoms that resemble primary pulmonary disease, particularly in late pregnancy and the early postpartum period. In clinical practice, this presentation often triggers alternative diagnostic pathways, introducing delay at a time when rapid cardiac assessment is critical. Although respiratory-dominant presentations are repeatedly described across case-based and observational reports, they have not been systematically examined as a distinct diagnostic pathway within the PPCM literature. CONTENT: This PRISMA-guided systematic review synthesized evidence relating to respiratory-onset presentations of PPCM. Major databases and registers were searched comprehensively. Following screening of 589 records and full-text assessment of 145 reports, 49 studies met inclusion criteria. Twenty studies were qualitatively prioritized for narrative synthesis using ROBIS-informed methodological appraisal. Evidence was examined across diagnostic misclassification patterns, cardiopulmonary mechanisms, differential diagnoses, investigative strategies, and acute and longitudinal management considerations. SUMMARY: Respiratory-led presentations were commonly misattributed to asthma, pneumonia, pulmonary embolism, or perioperative causes, with diagnostic delay frequently reported. Across heterogeneous study designs, cardiogenic pulmonary edema with left-ventricular systolic dysfunction emerged as a recurring unifying mechanism. Early use of echocardiography, natriuretic peptides, and targeted imaging consistently aided differentiation from primary respiratory pathology. Severe clinical deterioration was often described in the context of delayed recognition. OUTLOOK: Respiratory-onset PPCM represents a high-risk diagnostic pathway rather than a discrete disease entity. Prospective registries, standardized diagnostic algorithms, and closer integration of obstetric and cardiopulmonary care are needed to refine early recognition and improve maternal outcomes.

Humans

PdIr bimetallic nanozyme engineered metal-organic frameworks integrated dual-mode sensor toward Stx2 detection in food.

Shiga toxin II (Stx2) has attracted extensive attention due to its toxicity and pathogenicity, making the development of sensitive detection methods urgent. This study constructed a dual-mode sensing platform for the sensitive detection of Stx2 in food. Composite material UIO-66@PdIr with peroxidase-like activity and fluorescent properties was synthesized and combined with cDNA as the signal probe, while aptamer-modified magnetic beads served as the capture probe. Specific binding of Stx2 to the aptamer triggered the release of the signal probe, enabling colorimetric and fluorescence signal readout. The colorimetric mode showed a linear range of 0.05-100&#xa0;ng/mL with an LOD of 0.039&#xa0;ng/mL, and the fluorescence mode exhibited 0.01-1000&#xa0;ng/mL with an LOD of 0.0097&#xa0;ng/mL. Additionally, this method was successfully applied to the detection of Stx2 in food, and the recovery rates were 94.33%&#xa0;&#x223c;&#xa0;102.20%. It indicated that the constructed sensor holds great practical potential for Stx2 detection.

Food Contamination

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG&#xae; (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 &#xb1; 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans

Clinical performance evaluation of single-shade versus multi-shade composite resins in non-carious cervical lesions: a 36-month randomized clinical trial.

BACKGROUND: Composite resins are widely used as the material of choice for definitive restorations due to their ability to integrate functional and aesthetic aspects in dental rehabilitation. Recently, one-shade composite resins have been introduced to simplify the clinical workflow. OBJECTIVES: This study aimed to compare the clinical performance of a "chameleon effect" composite resin with that of a multi-shade composite resin in non-carious cervical lesions after 36 months of follow-up. METHODS: This study was a randomized, controlled, double-blind clinical trial with an equivalence design using a split-mouth approach. The sample consisted of 60 patients presenting at least two non-carious cervical lesions, totaling 120 restorations. Restorations were performed using two materials from the same commercial brand: Vittra Unique (one-shade group) and Vittra APS (multi-shade group). The clinical performance of the restorations was longitudinally evaluated according to the FDI criteria. Survival analysis was performed using Kaplan-Meier curves and the log-rank test, while other clinical parameters were compared using the chi-square test (&#x3b1; = 0.05). RESULTS: At baseline, no statistically significant differences were observed between the groups regarding the evaluated biological, functional, and aesthetic parameters (p > 0.05). Both materials demonstrated clinically acceptable performance according to the FDI criteria, with no significant differences between them. CONCLUSIONS: After 36 months, no significant differences were observed between the one-shade and the multi-shade composite resins in the restoration of non-carious cervical lesions. CLINICAL SIGNIFICANCE: This 36-month randomized clinical trial demonstrates that single-shade composite resins achieve structural durability and aesthetic integration equivalent to traditional multi-shade layering when restoring non-carious cervical lesions. This evidence validates a simplified, single-shade restorative workflow, significantly reducing chairside time and operator-dependent variables without compromising the clinical longevity.

Humans

Impact of renal dysfunction on immediate versus staged revascularization of non-culprit lesions in patients with ST segment elevation myocardial infarction: a pre-specified subgroup analysis of the randomized MULTISTARS AMI trial.

BACKGROUND: Renal dysfunction might affect outcomes in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease (MVD) undergoing percutaneous coronary intervention (PCI). METHODS: In MULTISTARS AMI, patients with STEMI and MVD were randomized to immediate or staged PCI of non-culprit lesions. In this pre-specified analysis, patients were stratified according to the presence of renal dysfunction at baseline, defined at an estimated glomerular filtration rate (eGFR) of 60&#xa0;ml/min/1.73 m2. Patients with an eGFR&#x2009;<&#x2009;30&#xa0;ml/min/1.73 m2 were excluded from the trial. The primary endpoint was a composite of death, non-fatal myocardial infarction, stroke, unplanned revascularization, or hospitalization for heart failure at 1&#xa0;year. RESULTS: In MULTISTARS AMI, 108 (13%) of 832 patients had renal dysfunction. The primary endpoint occurred more frequently in patients with renal dysfunction (19.4% vs. 11.2%, unadjusted HR 1.82, 95% CI 1.13-2.94), primarily driven by higher rates of death. Among patients with renal dysfunction, the rates of the primary end point were 14.5% and 24.5% in the immediate and staged PCI groups (unadjusted HR 0.55, 95% CI 0.23-1.33). There was no interaction between renal dysfunction and the randomized treatment assignment with respect to the primary end point (adjusted HR 1.30, 95% CI 0.8-2.20, pint 0.82). The occurrence of acute renal insufficiency was statistically similar in patients with renal dysfunction who underwent immediate and staged PCI (10.9% vs. 18.9%, unadjusted HR 0.61, 95% CI 0.22-1.72, pint 0.09). Renal dysfunction at baseline emerged as a strong risk factor for the development of acute renal insufficiency (adjusted HR 5.0, 95% CI 2.30-10.70, p&#x2009;<&#x2009;0.01). CONCLUSIONS: Outcomes with immediate compared to staged multivessel PCI did not appear significantly altered by the presence of renal dysfunction&#xa0;at baseline. (Supported by Boston Scientific; MULTISTARS AMI ClinicalTrials.gov number, NCT03135275).

Humans

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Cooperative anaerobic catabolism of chlorinated organic compounds: implications for sustainable bioremediation.

Biodegradation research historically followed a reductionist approach focused on axenic (pure) cultures capable of catabolizing the specific contaminant(s) of interest. While this approach has substantially advanced our understanding of the microbiology, physiology, biochemistry, and genetics of contaminant degradation under laboratory conditions, it does not capture the complexity of natural and engineered environments. During in situ bioremediation, microbiomes are exposed to mixtures of contaminants, and microbial interactions profoundly influence contaminant transformation and fate. In anoxic environments, degradation of chlorinated compounds is often sustained by metabolic cooperation among taxonomically and physiologically distinct microorganisms. Through the exchange of metabolites such as hydrogen, formate, acetate, and other nutrients, microbial populations establish interdependent networks that overcome thermodynamic and physiological constraints, enabling self-sustaining systems of contaminant transformations that would be inefficient or impossible with individual organisms. We highlight examples of microbial interactions that underpin anaerobic catabolism of chlorinated contaminants, including systems resulting in self-sustained anaerobic bioremediation.

Biodegradation, Environmental

Influence of endodontic access on the fracture resistance, retention and microleakage of full-coverage restorations in vitro: A systematic review and meta-analysis.

BACKGROUND: Endodontic access through retained full-coverage restorations (FCRs) is a preferred option for patients because of its high cost-effectiveness. However, the clinical performance of FCRs after repaired access cavity remains insufficiently characterized. This systematic review investigates the effects of endodontic access cavity preparation through retained FCRs on fracture resistance, retention, and microleakage based on in vitro studies. METHODS: A comprehensive search was performed in PubMed, Web of Science, and Scopus databases. Studies investigating the influence of endodontic access on the fracture resistance, retention, and microleakage of FCRs were included. Two independent reviewers conducted study selection, data extraction, and risk-of-bias assessment using the QUIN tool. Meta-analysis was employed to estimate fracture resistance and retention, with sensitivity analysis and subgroup evaluation also performed. Microleakage was summarized qualitatively. RESULTS: Twentythree studies were included: fracture resistance (n = 15), retention (n = 5), and microleakage (n = 3). Endodontic access significantly reduced fracture resistance for zirconia (p = 0.0002) and lithium disilicate (LD) restorations (p = 0.007), but not for resin-matrix ceramic (RMC) restorations (p = 0.25). Abutment tooth type contributed to heterogeneity within the LD and RMC subgroups. Retention was significantly reduced when access cavities were left unrepaired (p = 0.03), whereas appropriate repair protocols restored or enhanced retention relative to baseline. Accelerated aging increased microleakage in retained FCRs. Surface pretreatments and flowable resin liners tended to reduce microleakage, but findings were inconsistent. CONCLUSIONS: Endodontic access significantly reduces fracture resistance of zirconia and LD FCRs, whereas RMC restorations show no significant change. Appropriate repair protocols can restore or improve retention, potentially exceeding original values. Limited evidence suggests that effective sealing is achievable with appropriate materials. However, well-designed and in-vivo researches are needed to provide more detailed clinical guidance. CLINICAL SIGNIFICANCE: When performing endodontic access through retained FCRs, reduced fracture resistance must be carefully considered for zirconia and LD restorations, while RMC restorations may be exempt from this concern. Loss of retention with access can be restored after repair. Surface pretreatment and flowable resin liners help decrease microleakage.

Humans

Enhancement of secondary organic aerosol formation from isoprene photooxidation by ammonia.

Ammonia (NH3) can participate in atmospheric secondary organic aerosol (SOA) formation by reacting with organic acids and carbonyl compounds in particle phase, but its influence on the gas phase chemistry remains unclear. This study performed a series of smog chamber experiments to investigate the influence of NH3 on the formation of SOA from isoprene photooxidation by OH radicals. Both gas and particle phase products were measured with a series of state-of- art instruments including a nitrate ion chemical ionization mass spectrometer (nitrate-CIMS) and high-resolution time-of-flight aerosol mass spectrometer (HR-TOF-AMS). Our results showed that in the presence of NH3 SOA in the chamber significantly increased, along with an enhanced oxidation of isoprene. CIMS analysis further showed that NH3 in the chamber homogeneously reacts not only with gas-phase organic acids but also with gaseous low volatility oxygenated organic molecules (OOMs) to generate extremely low volatility and ultralow volatility NH3-OOMs clusters. Quantum chemical calculation showed that NH3 can spontaneously interact with OOMs to form NH3-OOMs clusters by forming hydrogen bonds with RCOOH, R-OOH, and R-OH. These clusters can promote new particles formation and particle growth through nucleation and condensation, directly enhancing the isoprene SOA production with a contribution of 78% to the enhanced SOA. Moreover, the formation of NH3-OOMs clusters also results in more isoprene consumed by OH radicals, indirectly increasing the SOA production with a contribution of 22 % to the enhanced SOA. Our work for the first time clarified a synergetic effect of NH3 on isoprene SOA formation, which should be accounted for by models.

Aerosols

Experiences of stigma, bias, and communication challenges among pregnant healthcare workers: A systematic review of qualitative evidence.

BACKGROUND: Healthcare work environments are fraught with occupational hazards that can impact pregnant healthcare workers' health as well as patient care. Despite the feminization of healthcare globally, systematic discrimination against pregnant workers persists across diverse healthcare settings and cultural contexts. The intersection of stigma, bias, and communication challenges creates substantial barriers to career advancement and wellbeing. However, no systematic review has synthesized qualitative evidence on how these three constructs interact across healthcare professions and cultural contexts using an integrated theoretical framework. OBJECTIVE: To systematically review and synthesize qualitative evidence on experiences of stigma, bias, and communication challenges among pregnant healthcare workers across different healthcare settings and cultural contexts using an integrated theoretical framework. DESIGN: Systematic review of qualitative studies following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines with thematic synthesis. DATA SOURCES: Seven databases were searched from inception to January 2026. REVIEW METHODS: Included qualitative studies were appraised using the Critical Appraisal Skills Programme (CASP) checklist and synthesized through theory-guided thematic synthesis. Confidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation-Confidence in the Evidence from Reviews of Qualitative research (GRADE-CERQual) approach. RESULTS: Fourteen studies encompassing 1223 participants across 17 countries revealed four major themes: (1) professional identity stigma and workplace discrimination through systematic labeling and stereotyping; (2) gender-based institutional bias rooted in masculine organizational logic; (3) multilevel communication failures creating fear-based climates; and (4) individual and collective resistance strategies developed despite constraints. Occupational hazards specific to pregnancy included exposure to infectious diseases, imaging, physical tasks, cleaning products, patient violence, and medication administration. Support from coworkers and supervisors was identified as the most critical facilitator for avoiding hazards and making necessary modifications, while the desire to be 'supernurses' and fear of consequences emerged as significant barriers. These patterns were consistent across healthcare professions, settings, and cultural contexts, with specialty culture and healthcare system type moderating discrimination intensity. Confidence in core findings was rated high using GRADE-CERQual. CONCLUSIONS: Pregnant healthcare workers globally experience interconnected stigma, bias, and communication challenges that are systematically embedded within healthcare organizational structures. These challenges operate synergistically, requiring comprehensive multilevel interventions beyond policy compliance. Healthcare organizations must implement evidence-based strategies addressing stigma reduction, bias interruption, and communication transformation simultaneously to retain skilled workers and ensure quality patient care.

Female

Biochemical Insights Into the Conserved Interactions of NMD Factors From Budding Yeast to Humans.

Nonsense-mediated mRNA decay (NMD) is one of the most extensively studied pathways of cytoplasmic mRNA degradation. It plays a critical role in diverse cellular processes by eliminating aberrant transcripts containing premature stop codons and by regulating the stability of physiological mRNAs. NMD factors were initially identified through genetic screens in S. cerevisiae (UPF1, 2, 3) and C. elegans (SMG-1, SMG5-7). Subsequent biochemical and genetic studies revealed the composition of NMD complexes and identified additional factors. A major protein hub for NMD is Upf1, an ATP-dependent RNA helicase that is part of two mutually exclusive NMD assemblies, the Upf1-Upf2-Upf3 complex and the Upf1-decapping complex, which contains the decapping enzyme and its co-factors. Here, we discuss recent findings, primarily from budding yeast, on the protein-protein interactions driving NMD complexes dynamics and their similarities to human NMD. Together, the N-terminal cysteine and histidine rich (CH) and helicase domains (HD) of Upf1 act as a hub for binding multiple partners. Upf1 is required for binding to NMD substrates and for the initiation of RNA degradation through decapping (yeast) or endonucleolytic hydrolysis (humans). We focus on the interplay between Upf2, Dcp2 and Nmd4 (yeast SMG6), which ensures the mutually exclusive formation of Upf1-bound subcomplexes modulating Upf1's affinity for RNA. Thus, the study of NMD factors interactions in different organisms sheds new light on the remarkable conservation of NMD molecular mechanisms.

Nonsense Mediated mRNA Decay

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans