Search PubMedSearch

SEARCH · Search PubMed

Results for “Multiparametric Magnetic Resonance Imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

254 records · Page 6Linked to original sources

Engineering copper ferrite (CuFe2O4) nanocomposites for enhanced eco-friendly photocatalysis: a systematic critical review on mechanisms, performance, and environmental applications.

Water pollution caused by organic and inorganic contaminants, particularly dyes and pharmaceuticals, represents a major environmental challenge. Advanced oxidation processes based on photocatalysts have emerged as efficient and sustainable approaches for water and wastewater treatment. Copper ferrite (CuFe2O4) is considered a promising photocatalyst owing to its narrow bandgap, visible-light activity, chemical stability, and magnetic properties. Despite extensive experimental investigations, a comprehensive systematic comparison of CuFe2O4-based photocatalysts under diverse operational conditions has remained limited. In this study, a systematic review following PRISMA guidelines was conducted using studies published between January 2014 and November 2025 indexed in Scopus, PubMed, Web of Science, and ScienceDirect. From an initial pool of 397 studies, 98 articles met the inclusion criteria. Key parameters - including pollutant type, pH, catalyst dosage, initial pollutant concentration, irradiation time, light source, and degradation efficiency - were quantitatively compared to identify performance trends and operational optima. The results demonstrate that CuFe2O4-based nanocomposites, particularly heterojunction, Z-scheme, and S-scheme architectures combined with TiO2, g-C3N4, graphene, and metal oxides, achieve high degradation efficiencies (often >90 %) for a wide range of organic pollutants and selected inorganic contaminants (e.g., Cr(VI)). Enhanced charge separation and suppressed electron-hole recombination were identified as the primary factors contributing to improved photocatalytic activity. In addition, the intrinsic magnetic properties of these nanocomposites enable facile catalyst recovery and reuse. In conclusion, CuFe2O4-based nanocomposites, especially those incorporating advanced heterojunction architectures, emerge as highly efficient and magnetically recoverable photocatalytic platforms for sustainable water and wastewater treatment, with strong potential for scalable implementation and real-wastewater applications.

Catalysis

How, When, and for Whom Does Daily Weight Bias Internalization Undermine Body Image Satisfaction? A Daily Diary Study of Perceived Weight, Exercise Duration, and Gender Differences Among Adolescents.

Although body image satisfaction is increasingly recognized as a dynamic experience that fluctuates across daily contexts, little is known about how weight bias internalization shapes these fluctuations or the cognitive mechanisms and contextual factors involved. The present study examined whether perceived weight mediates the association between weight bias internalization and body image satisfaction, whether exercise duration moderates this association, and whether these effects differ by gender. Daily diary data were collected over 10 consecutive days from 305 Chinese adolescents (Mage = 12.59 years, SD = 0.63 years; 49.2% girls). Multilevel analyses revealed that, at both within- and between-person levels, higher weight bias internalization was associated with lower body image satisfaction. Perceived weight significantly mediated the association between weight bias internalization and body image satisfaction at both levels. Additionally, exploratory analyses using dynamic structural equation modeling further indicated that perceived weight mediated the relationship between weight bias internalization and body image satisfaction at the between-person level, but not at the within-person level. Furthermore, exercise duration moderated the association between perceived weight and body image satisfaction among female adolescents but not among male adolescents. Specifically, the negative association between perceived weight and body image satisfaction was stronger on days when girls engaged in more exercise than usual and among girls with higher average exercise duration. In addition, exercise duration moderated the indirect association between weight bias internalization and body image satisfaction through perceived weight at both within- and between-person levels among girls. These findings highlight the dynamic cognitive processes linking weight bias internalization to body image satisfaction, and the importance of considering gender and daily exercise context in understanding adolescents' body image experiences.

Humans

Indigenous body image amid rapid social and economic change: A reflexive thematic analysis of Wayuu narratives.

The Wayuu, Colombia's largest Indigenous group, are experiencing rapid social, economic, and technological change, including expanding internet access, educational opportunities, and increasing exposure to globalised media. Though the harmful effects of appearance-idealised media imagery on body image are well documented, indigenous body image research remains unevenly distributed across global contexts, with Latin American Indigenous communities particularly underrepresented. This study explored how Wayuu people understand and experience appearance ideals and body image in the context of expanding digital media exposure and rapid sociocultural and economic change. Five focus groups of up to 9 participants were conducted with 29 Wayuu participants (18-68 years; 23 women, 6 men). Using reflexive thematic analysis, three overarching themes were identified: (1) Intersecting sources of appearance pressure: encompassing influences from social media, Wayuu family expectations, and discrimination from non-Indigenous peers; (2) Negotiating and resisting appearance ideals: from body dissatisfaction and restrictive eating to affirmation of cultural identity as protection; and (3) The changing role of appearance in today's Wayuu culture: participants linked globalised appearance ideals to expanding educational opportunities, migration, digital connectivity, and broader socioeconomic transformations occurring within Wayuu territories. While exposure to global ideals fostered comparison and dissatisfaction, cultural pride and collective belonging appeared to buffer against internalised colonial values. Culturally grounded media literacy and education initiatives co-developed with Wayuu communities could foster critical reflection while strengthening heritage. These results highlight the need for decolonial, community-based approaches to body image research and intervention in Indigenous contexts.

Adolescent

Instruments for measuring body image in breast cancer patients: a systematic review of measurement properties.

PURPOSE: To evaluate the psychometric properties of PROMs for measuring body image in breast cancer patients. METHODS: In December 2024, a psychometric systematic review was performed in the nine databases. The COSMIN checklist was employed to evaluate the methodological quality and psychometric properties of the included body image measures. The level of evidence was assessed using the GRADE framework, and final recommendations were formulated for the scale. RESULTS: Thirty-eight articles evaluating fifteen PROMs were included in this review. Structural validity, internal consistency, and hypothesis testing had been most frequently evaluated. Measurement error had not been assessed for all PROMs. Twelve instruments show potential application value but require further research. The BAS-BC, PSPP, and ASI-R are not recommended for use, as these instruments do not meet the strict COSMIN thresholds for full recommendation. CONCLUSION: The BIS can be recommended as a temporary screening tool for assessing body image outcome in clinical practice. The BIRS can be tentatively advised for measuring specific postoperative body image changes. However, further comprehensive studies are required to validate the psychometric properties of existing PROMs.

Female

AI-driven snapshot hyperspectral imaging for on-line sorting systems in food industry: From real-time sensing to intelligent decision-making.

High-throughput food sorting requires rapid, non-destructive detection of external defects, foreign materials, and internal quality attributes in heterogeneous food matrices. Conventional scanning hyperspectral imaging may suffer from motion-induced spatial-spectral mismatches, whereas snapshot hyperspectral imaging (S-HSI) captures spectral images within a single integration time. However, its advantage is limited by trade-offs in resolution, signal-to-noise ratio (SNR), reconstruction uncertainty, and calibration stability, which are further amplified by variable tissue structure, surface reflection, moisture, and fat distribution in foods. This review critically examines artificial intelligence (AI)-driven S-HSI for on-line food sorting within a sensing-representation-decision-execution framework. Compact architectures are compared according to their physical constraints, food-sorting suitability, and ability to support mapping between spectral responses and physicochemical quality attributes. AI strategies are reviewed for spectral reconstruction, image restoration, spatial-spectral representation, band selection, uncertainty-aware decision-making, and edge implementation. AI can partially compensate for snapshot-specific limitations, but current evidence remains largely limited to laboratory or prototype studies. Future work should link system performance to food safety and quality outcomes by reporting throughput, decision latency, calibration drift, missed-detection risk, false-rejection cost, and closed-loop sorting success.

Hyperspectral Imaging

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8 ± 2.3 nm for Cy5 and 13.5 ± 2.9 nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28 nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

The effects of fitspiration TikTok content on body image and mood among young adult women in the U.S.

Fitspiration is an appearance-based form of media that promotes physical fitness and dieting. While not true of all fitspiration media, some forms promote these ideals through visuals of toned, athletic bodies that have become increasingly prevalent on the short-form video platform, TikTok. Although often framed as health-promoting, fitspiration exposure has been associated with upward appearance comparison (i.e., comparison with people perceived as more attractive) and negative effects on body image and mood. The present study investigated the effects of short-form video-based fitspiration on social comparison, appearance importance, appearance anxiety, body dissatisfaction, and negative affect. Using an experimental design, 150 undergraduate women (Mage = 19.28) in the United States were randomly assigned to view a five-minute TikTok compilation of either animal (n = 75) or fitspiration videos (n = 75). Participants completed baseline measures prior to viewing and state-level measures after completing their video set. Results indicated that, relative to control, viewing fitspiration content led to greater social comparison, appearance concerns, feelings of being fat, and sadness. Baseline appearance concerns and depressive symptoms significantly moderated group differences in responses, such that negative fitspiration effects on state-level appearance concerns were found among individuals high but not low in baseline appearance concerns and among individuals low but not high in baseline depressive symptoms. These findings contribute to the growing literature on fitspiration by demonstrating the immediate psychological effects of this content in short-form videos and highlighting the importance of considering individual differences in vulnerability.

Humans

Diagnostic performance of intraoperative in vivo hyperspectral imaging for meningioma grading and molecular alterations: results from a prospective feasibility study.

OBJECTIVE: Hyperspectral imaging (HSI) is an emerging intraoperative, noninvasive, contrast agent-free imaging modality that enables quantitative assessment of tissue composition. The present study aimed to investigate whether HSI-derived tissue parameters correlate with WHO grade and molecular markers of aggressiveness in cranial meningiomas. METHODS: In this prospective study, intraoperative in vivo HSI was performed using the TIVITA tissue system, capturing spectral signatures between 500 and 1000 nm. Quantitative tissue parameters included tissue oxygen saturation (StO2), near-infrared perfusion index, organ hemoglobin index (OHI), and tissue water index (TWI). HSI parameters were correlated with histopathological WHO grade and molecular alterations, including CDKN2A/B deletion, TERT promoter mutation, and 1p/22q loss. Group differences were analyzed using one-way ANOVA, and diagnostic performance was assessed using receiver operating characteristic (ROC) analysis. RESULTS: Forty-six meningiomas were included, comprising WHO grade 1 (n = 35) and WHO grade 2-3 (n = 11) tumors. TWI was significantly higher in WHO grade 2-3 meningiomas compared with WHO grade 1 tumors (mean 0.49 [SD 0.12] vs 0.38 [SD 0.17], p = 0.048). ROC analysis demonstrated an area under the ROC curve (AUC) of 0.71 (95% CI 0.56-0.86, p = 0.036) for TWI in discriminating higher-grade disease. A TWI cutoff ≥ 0.367 identified all WHO grade 2-3 meningiomas with 100% sensitivity and 100% negative predictive value. In a molecular subgroup (n = 15), OHI appeared higher in tumors with homozygous CDKN2A/B deletion than in nondeleted tumors (mean 0.77 [SD 0.04] vs 0.62 [SD 0.10]). However, only 3 CDKN2A/B-deleted cases were available, and these findings should be considered descriptive. ROC analysis yielded an AUC of 0.89 (95% CI 0.71-1.00). An OHI cutoff ≥ 0.712 identified all three CDKN2A/B-deleted tumors (100% sensitivity), with 83.3% specificity and 86.7% accuracy. CONCLUSIONS: The present investigation demonstrated that HSI-derived tissue water and hemoglobin metrics provide biologically meaningful information in meningiomas. Low tissue water content appeared to rule out higher-grade diseases in this first subset cohort, while elevated hemoglobin showed a potential association with CDKN2A/B deletion in a small exploratory subgroup. These findings support the potential of HSI as a real-time noninvasive tool for intraoperative risk stratification and should be evaluated in large-scale studies. German Clinical Trials Register no. DRKS00036771 (www.drks.de).

Humans

Dual-Reporter Gene-Based Multimodal Imaging for Tracking Mesenchymal Stem Cells in Diabetic Skin Wound Repair.

BACKGROUND: Diabetic foot ulcer (DFU) is a clinically challenging complication characterized by poor healing outcomes, and conventional therapies provide limited benefit. Mesenchymal stem cell (MSC) transplantation offers a promising strategy for DFU repair. However, the low survival of transplanted MSCs in the hostile wound microenvironment, coupled with the lack of real-time, non-invasive methods to track these cells in vivo, severely hampers their therapeutic efficacy and clinical translation. METHODS: We engineered MSCs to co-express a dual reporter system comprising near-infrared fluorescent protein (iRFP) and ferritin heavy chain (FTH1). These modified cells were then integrated with a fibrin glue (FG) scaffold to create a unified platform that supports both multimodal imaging and therapeutic function within skin wounds. First, FTH1 overexpression enhances the antioxidant capacity of MSCs, while the FG scaffold provides structural support; this combination enhances cell survival and retention. Second, the iRFP/FTH1 dual reporter enables near-infrared fluorescence imaging and MRI-based localization, establishing a multimodal platform for real-time cell tracking. RESULTS: In a full-thickness skin defect model in diabetic mice, multimodal imaging revealed that transplanted cells persisted in the wound area for approximately seven days. Treatment with iRFP/FTH1-MSCs/FG significantly accelerated wound closure and promoted hair follicle regeneration and angiogenesis. Additionally, local iron deposition resulting from FTH1 expression enhanced fibroblast migration and collagen synthesis, further facilitating extracellular matrix remodeling. Mechanistic studies demonstrated that this therapy drives macrophage polarization toward the anti-inflammatory M2 phenotype and activates the PI3K-AKT-VEGF signaling pathway. These complementary effects synergistically enhance tissue regeneration and systematically improve diabetic wound healing. CONCLUSIONS: Collectively, this multimodal stem cell-scaffold system effectively integrates dynamic cell tracking with stem cell therapy during skin wound repair. It addresses a critical technical gap in visualizing stem cells within the wound microenvironment and provides valuable methodological and theoretical foundations for optimizing regenerative strategies for diabetic skin wounds.

Animals

Intraoperative indocyanine green near-infrared fluorescence imaging for assessing testicular viability in pediatric testicular torsion: A retrospective study.

OBJECTIVE: To evaluate the clinical efficacy of indocyanine green near-infrared fluorescence (ICG-NIRF) imaging versus conventional surgery for assessing testicular viability and guiding decision-making in pediatric testicular torsion (TT). METHODS: A retrospective analysis was performed on 225 pediatric patients undergoing emergency scrotal exploration for TT between January 2019 and January 2025. Patients were categorized into a conventional surgery group (n = 118) relying on visual grading and an ICG-NIRF imaging group (n = 107). Primary outcomes included intraoperative testicular preservation rates and postoperative success rates. Multivariate Cox regression was utilized to identify factors influencing testicular preservation. RESULTS: Baseline characteristics were comparable between groups. The ICG-NIRF group demonstrated a significantly higher intraoperative preservation rate (74.77% vs. 61.02%, p = 0.028) and postoperative success rate (88.75% vs. 69.44%, p = 0.003) compared to the conventional group. Additionally, the ICG-NIRF group exhibited significantly lower rates of secondary orchiectomy (1.25% vs. 9.72%, p = 0.027) and 6-month testicular atrophy (7.59% vs. 23.08%, p = 0.02). Multivariate analysis confirmed ICG-NIRF application as an independent protective factor for testicular preservation (HR = 0.556, p < 0.001). CONCLUSION: ICG-NIRF imaging provides an objective, real-time assessment of testicular perfusion, significantly improving testicular preservation rates and postoperative outcomes. This technique overcomes the subjectivity of conventional visual methods, offering substantial clinical value for fertility preservation in pediatric TT.

Humans

Application of Perioperative Real-Time Fluorescence Imaging to Achieve High-Quality Debridement: A Randomized Control Trial.

OBJECTIVE: To investigate the effectiveness of real-time fluorescence imaging (RTFI)-assisted debridement in managing chronic wounds compared with standard surgical debridement. APPROACH: This study was a patient-blinded, randomized clinical trial conducted from February 17, 2021, to July 30, 2021, on patients with chronic wounds. Patients were randomized to an RTFI group (M group) or conventional group (C group). The primary outcomes were as follows: percentage of residual bacterial area (preoperative and postoperative), number of debridements, high-quality debridement ratio, operation duration, and wound healing duration. RESULTS: A total of 100 patients were enrolled in both groups. No significant difference in the percentage of preoperative residual bacterial area or high-quality debridement ratio was seen. The M group underwent debridement an average of 2.6 times and had a significantly longer duration of operation (33.5 &#xb1; 12.7 min) than the C group (29.9 &#xb1; 10.4 min; p = 0.031). The postoperative residual bacterial area was significantly lower in the M than in the C group (6.83% &#xb1; 1.39% vs. 30.0% &#xb1; 12.37%, respectively; p < 0.001). The M group required significantly fewer wound healing days (49.2 &#xb1; 25.3 vs. 63.0 &#xb1; 27.9, p < 0.001). Secondary outcomes also demonstrated statistically significant differences in total hospitalized days (17.5 &#xb1; 9.3 vs. 21.5 &#xb1; 12.5, p < 0.01), days of antibiotic use (15.5 &#xb1; 8.7 vs. 18.7 &#xb1; 6.7, p < 0.01), and reinfection rates (4 of 100 vs. 22 of 100, p < 0.001). INNOVATION: RTFI can detect signals from normal skin components and bacterial metabolites. Therefore, interpretation of RTFI results should be correlated with the clinical condition. RTFI is associated with high-quality debridement. This technique can also be applied in targeted biopsy and in training young staff to mature debridement procedures. CONCLUSION: RTFI in debridement is associated with favorable clinical outcomes and may have a positive influence on chronic wound healing.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

The role of media in reducing and reinforcing stigma: A randomized controlled trial investigating the impact of positive and negative representations of visible difference.

OBJECTIVES: Individuals with visible differences often experience appearance-related stigma and discrimination, reinforced by negative media portrayals. In contrast, positive portrayals may challenge stereotypes and promote acceptance. This study examined whether exposure to positive, negative or neutral images of visible difference influences appearance-related stigma, body appreciation and broad conceptualizations of beauty. It was hypothesized that positive images would decrease stigma and increase body appreciation and broad conceptualizations of beauty, whereas negative images would increase stigma and reduce broad conceptualizations of beauty. DESIGN: An online randomized controlled experiment using a mixed repeated-measures design compared three conditions (positive, negative, neutral) across pre- and post-exposure. METHODS: A sample of 103 adults viewed 10 images of individuals with visible differences presented in one of three conditions: positive (positive captions), negative (villains with visible differences and negative captions) or neutral (without captions). Participants completed pre- and post-measures of appearance-related stigma, body appreciation and broad conceptualizations of beauty. Repeated-measures ANOVAs examined within- and between-group changes. RESULTS: Appearance-related stigma significantly increased in the negative condition, while remaining unchanged in the positive and neutral groups. Body appreciation significantly increased from pre- to post- across all conditions. No significant effects emerged for broad conceptualizations of beauty. CONCLUSIONS: Negative portrayals of visible difference may reinforce stigma, highlighting the need to discourage such depictions in media. While positive exposure did not significantly reduce stigma, viewing images of visible difference increased observers' body appreciation, indicating potential downward social comparison. Future research should explore strategies to strengthen stigma reduction and broaden conceptualizations of beauty.

Humans

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Non-destructive prediction of lead content in oilseed rape leaves by fluorescence hyperspectral technology based on neural network.

Based on fluorescence hyperspectral imaging (FHSI), this study targeted rapid, non-destructive quantification of lead (Pb) content in oilseed rape leaves treated with varying silicon (Si) concentrations, acquiring fluorescence spectra over the 484.43-1001.61&#xa0;nm wavelength range. To optimize spectral data quality, preprocessing methods (Savitzky-Golay smoothing, first derivative, detrending) were comprehensively compared. Characteristic wavelengths were then selected via interval variable iterative shrinkage, which effectively compressed data dimensionality and reduced computational load. A hybrid SE-CL1DA model, fusing a 1D convolutional neural network, a long short-term memory network and SE attention mechanism was constructed, with Bayesian optimization tuning hyperparameters to boost stability. The BO-SE-CL1DA outperformed both traditional machine learning and insufficiently optimized deep learning model (Rp2=0.9609, RMSE&#xa0;=&#xa0;0.0377&#xa0;mg/kg, RPD&#xa0;=&#xa0;5.1736), thus enabling accurate Pb estimation, supporting Si-regulated heavy metal stress management and facilitating agricultural contamination monitoring.

Plant Leaves

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics