Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

A CFD study of the deep bed filtration mechanism for submicron/nano-particle suspension.

The mechanism of the deep bed filtration for submicron and nano particles suspension was conducted by means of a force analysis on the suspended particles flow path through order-packed granular filter beds. The flow fields through the filter beds were calculated by using the commercial available CFD software--Fluent. Various types of granular packing structures, such as the simple cubic packing, body-centered packing and face-centered packing structures were chosen for analysis. The motion of suspended particle of 2.967, 0.816, 0.460 and 0.050 microm in diameter, respectively, were tracked by considering the following forces including a net gravitational force, hydraulic drag force, lift force, Brownian force, van der Waals force and a double layer force. The effects of the granular bed packing structure, the porosity of these beds and the suspended particle diameter on the capture efficiency of a granular filter bed were examined. The force analysis depicts that the inertial effect and van der Waals force increased the capture probability of particles on the granular filter bed while the lift force and the Brownian force decreased the particle deposition. Simulated results show that among the chosen packing structures, the face-center packed granular bed gives the greatest pressure drop and capture efficiency of particles due to the lower packing porosity. The simple cubic packed filter bed showed the lowest pressure drop and capture efficiency of particles due to the greatest packing porosity among the chosen packing structures. It is mainly due to the simple cubic packing structure in which there exists the free vertical downward flowing path and thus exhibits a higher packing porosity. The comparisons of the simulated capture efficiency with experimental results depicted that the body-centre packed granular bed showed the best approximation of capture efficiency compared to that of the randomly packed granular bed.

Computer Simulation↗

[Experiment on the formation and characterizations of anodic alumina membrane for use in hemodialysis].

The correlations between various formation conditions and the membrane pore characterizations of the anodic alumina membrane were investigated for seeking the optimal conditions for the formation of anodic alumina membrane. High purity aluminum foils were used as the starting materials. The anodizations were conducted under three types of electrolytes, 3% sulfuric acid, 5% sulfuric acid and 2.7% oxalic acid, respectively, with different voltages at 0 degrees C for 48 hours. The characterizations of the pore size, the effective porosity and the pore porosity were observed and determined by scanning electron microscopy. The hydraulic conductance of the membranes was measured to confirm that the pores were open and to evaluate the permselectivity of the membranes. The experimental results showed that the ordered pore arrays were obtained for oxidation under our experimental conditions. While the forming voltage was increasing, the pore size and pore porosity increased significantly (P < 0.05), and the effective porosity decreased significantly (P < 0.05). The pore size formed with 3% sulfuric acid or 5% sulfuric acid was much smaller than that with 2.7% oxalic acid as an electrolyte. The hydraulic conductance of anodic alumina membrane that formed under our experimental condition was high than those of the membranes currently available in clinical procedures. The results suggested that the optimal conditions for the formation of anodic alumina membrane to be used in hemodialysis should be 3% or 5% sulfuric acid with 12.5 V to 17.5 V at 0 degrees C for 48 hours.

Aluminum Oxide↗

[Use of mercury porosimetry, assisted by nitrogen adsorption in the investigation of the pore structure of tablets].

The microstructure of pharmaceutical solid dosage forms (porosity, pore volume-size distribution, specific surface area) can be investigated by different methods. Mercury porosimetry and nitrogen gas adsorption have been widely used to characterize the pore structure of tablets because these methods enable the determination of porosity and pore size distribution in one step. The two techniques are based on different physical interactions and cover specific ranges of pore size. Mercury porosimetry determines mesopores and macropores, whereas gas adsorption covers the micropore range. The aim of this study was to investigate the relationship between the compression force and the structure of tablets containing theophylline. The porosity parameters determined with mercury porosimetry and nitrogen adsorption were compared. The results indicated a good correlation between the applied compression forces and the porosity parameters of the tablets. The pore volume-size distributions, the pore size frequencies and the specific surface areas obtained with mercury porosimetry and nitrogen adsorption were not equal, which can be attributed to the different measurement ranges and to the complexity of the pore structures. Our results allow the conclusion that mercury porosimetry, assisted by nitrogen adsorption as a complementary technique, is an acceptable method to achieve a proper characterization of the internal structure of tablets.

Adsorption↗

Comparison of microwave-polymerized denture base resins.

Three denture base resins, two designed for microwave polymerization and one for host-water-bath-processing, were compared. Results indicated that all four tested thicknesses (3, 6, 11.6, and 17.7 mm) of the water-bath-polymerized samples and one of the microwave-polymerized resins were porosity-free. When the water-bath-polymerized material was microwave processed, porosity was found when resin thickness exceeded 3 mm. When one resin designed for microwave polymerization was irradiated using the high-wattage (513 W), shorter cycle (4 minutes 52 seconds), porosity also occurred when the thickness exceeded 3 mm. Porosity did not occur until there was 9 mm of thickness when the lower-wattage (75.9 W), longer cycle (15 minutes 26 seconds) was used. No significant differences in transverse strength or hardness were noted between the materials.

Denture Bases↗

Synthesis of macroporous hydroxyapatite scaffolds for bone tissue engineering.

A novel method of preparing macroporous hydroxyapatite (HA) by dual-phase mixing was developed: HA slurry and Polymethylmethacrylate (PMMA) resin were mixed together at the volume ratio of 1:1. After pyrolytic removal of the PMMA phase, HA with an open porous structure was obtained. In this way, the porosity of the ceramic was limited to 50%. Attempts to increase the porosity by adding more PMMA resin were confronted with the technical hurdle of sample collapse during the pyrolysis process. To increase the porosity and to improve pore interconnection, an extra foaming step was introduced before the polymerization of PMMA resin. Three foaming agent systems were tried, based on the reactions of citric acid and (bi)carbonate salts: sodium bicarbonate, calcium carbonate, and ammonium bicarbonate. Although all the three foaming agents were able to increase the porosity up to 70%, keeping all the pores interconnected throughout, only ammonium bicarbonate system turned out to be applicable to make HA scaffolds or implants, because both NaHCO(3) and CaCO(3) systems caused alkalic residues in the final ceramic. The porous HA samples were fully characterized by FTIR, XRD, ESEM (EDX), and optical microscopy.

Bone and Bones↗

Polymer-ceramic composite for tooth-root implant.

A new polymer-ceramic composite suitable for tooth-root implants has been developed in this study. This material exhibited the desirable combination of good mechanical properties, controlled porosity, and ease of processing. A thermal processing technique was utilized to polymerize acrylic acid (AA) in the presence of either 0.3 or 0.05 mu alumina particles. Porosity and pore size distribution were influenced by the alumina particle size and the processing technique. For a 50 vol % AA solution, the composite had an average compressive strength of 18,000 psi and 38% porosity when 0.3 mu filler particles were used. In comparison, the 0.05 mu alumina-filled composite had an average compressive strength of 28,000 psi with a 15% porosity. Data on the physical and structural characteristics of the composite are presented in this study. Based on these results, the composite material shows good potential for use in tooth-root implants as well as other orthopedic implant applications.

Absorption↗

Effects of the initial temperature of acrylic bone cement liquid monomer on the properties of the stem-cement interface and cement polymerization.

It has been shown that preheating the femoral stem prior to insertion minimizes interfacial porosity at the stem-cement interface. In this study, the effects of methylmethacrylate monomer temperature prior to mixing on the properties of stem-cement interface and cement polymerization were evaluated for 4 degrees C, room temperature, and 37 degrees C using a test model and cementing techniques that simulated a clinical situation. The nature and extent of interfacial porosity of stem-cement interface was quantified, the static shear strength of the stem-cement interface determined, and the time and temperature of polymerization at the cement-bone interface were measured. Compared to RT monomer, preheating monomer to 37 degrees C produced higher polymerization temperatures and greater initial interfacial shear strength with an unchanged amount of interfacial porosity. Precooling monomer to 4 degrees C produced lower polymerization temperatures and decreased initial interfacial shear strength, with the amount of interfacial porosity unchanged compared to the RT group. Although clinical techniques of preheating or precooling bone cement have some effects on the properties of the stem-cement interface and cement polymerization, they do not appear to enhance implant fixation.

Chromium↗

Mathematical model for repair of fatigue damage and stress fracture in osteonal bone.

This paper assembles current concepts about bone fatigue and osteonal remodeling into a mathematical theory of the repair of fatigue damage and the etiology of stress fracture. The model was used to address three questions. (a) How does the half-life of fatigue damage compare with the duration of the remodeling cycle? (b) Does the porosity associated with the remodeling response contribute to stress fracture? (c) To what extent is a periosteal callus response necessary to augment repair by remodeling? To develop the theory, existing experimental data were used to formulate mathematical relationships between loading, damage, periosteal bone formation, osteonal remodeling, porosity, and elastic modulus. The resulting nonlinear relationships were numerically solved in an iterative fashion using a computer, and the behavior of the model was studied for various loading conditions and values of system parameters. The model adapted to increased loading by increasing remodeling to repair the additional damage and by adding new bone periosteally to reduce strain. However, if too much loading was encountered, the porosity associated with increased remodeling caused the system to become unstable; i.e., damage, porosity, and strain increased at a very high rate and without limit. It is proposed that this phenomenon is the equivalent of a stress fracture and that its biological and mechanical elements are significant in the etiology of stress fractures. Additional experiments must be done to test the model and provide better values for its parameters. However, the instability characteristic is relatively insensitive to changes in model parameters.

Animals↗

A model of flow-through pore formation in methacrylate ester-based monolithic columns.

The main factors affecting the porosity of methacrylate-ester based monolithic columns were investigated. We prepared 23 monolithic capillary columns with porosity controlled by varying the proportions of butyl methacrylate and ethylene dimethacrylate monomers and of 1,4-butanediol and 1-propanol as the porogen solvent in the polymerization mixtures by thermally initiated in-situ polymerization in fused-silica capillaries. Using mixture design software, we systematically varied the composition of the polymerisation mixtures to find significant factors affecting flow-through pore formation. Multivariate analysis of the experimental data obtained for the fabricated columns yielded a model for prediction of the flow-through porosity in monolithic beds as a function of the composition of the polymerization mixture used to prepare polymethacrylate monolithic capillary columns. The mean error of prediction was lower than 8% for eight columns prepared independently of the original set of 15 columns used to derive the flow-through model. The flow-through porosity increases with increasing concentration of the binary porogen solvent mixture, the concentration of 1,4-butanediol being the main factor enhancing flow-through pore formation. On the other hand, increasing concentrations of the hydrophobic monomer butyl methacrylate and increasing concentrations of 1-propanol have a negative effect on flow-through pore formation. The capillary columns prepared with a high proportion of flow-through pores and a minimum amount of mesopores can be used for fast gradient separations of both low-molecular weight compounds and biopolymers.

Journal Article↗

Water diffusivity in starch-based systems.

The objective of this study was to investigate the influence of structure, and component interactions, on the sorption and transport properties of water in starch-based systems. We compared the effective diffusivity (Deff) of water in two starches, with differing amylose-amylopectin ratios, using either kinetics of water adsorption or analysis of drying curves (water desorption) to estimate Deff. The effect of incorporating small sugar molecules into the granular or gelatinized starch matrices on Deff was measured by drying curve analysis. To investigate the possible mechanisms of water transport, the porosity and microscopic appearance of the samples at different stages of drying were determined. In a complementary study, sorption isotherms and the number of accessible "binding" sites in the starch and starch-sugar systems were determined using gravimetric analysis and inverse gas chromatography (IGC) 'probe analysis'. In the case of the starch-sugar systems, the measurements were made after the components had been 'mechanically mixed', or after more intimate mixing had been achieved by a co-freeze-drying process. The Deff of the starches was found to depend, in a complex way, on the moisture content of the samples. At relatively high moisture contents, the predominant mode of water transport was by liquid diffusion. As the samples became drier, their porosity increased, and the predominant mode of moisture transport was by vapor phase diffusion. As the samples became very dry (less than 10% water content), Deff fell significantly. Incorporation of sugars, in general, led to a reduction of Deff, which was correlated with a corresponding fall in porosity. In agreement with the findings of other workers, for the starches studied, the value of Deff determined from water adsorption measurements was significantly less than Deff determined from water desorption (drying curve analysis). The form of the Deff versus moisture content relationship was, however, independent of the method of measurement (adsorption or desorption). The water sorption and IGC probe analysis results indicated that some physicochemical interaction was expedited by the freeze-drying process. This interaction was manifested by a reduction in water sorption at a given relative vapor pressure, and by major changes in the accessibility of the co-freeze-dried samples to organic probe molecules. Taken together, the results indicate that water transport (diffusion) in starches and in starch-sugar mixtures is dependent significantly on gross structural features (development of porosity during drying), but that specific molecular, physico-chemical interactions must also be considered.

Adsorption↗

Cortical bone senescence and mineral bone density of the humerus.

Study of the humeral cortex of 89 acute cadavers showed that an important factor contributing to the physiologic bone loss of aging is increasing bone porosity. Mean cortical porosity increases in both sexes with age, from 4.6% in men and 4% in women at 40 years of age to 10% and more at age 80. In the population studied, no significant difference of porosity was observed between men and women. Apparent mineral density is linked to porosity, and decreases markedly with age in women. Changes in men are lesser in magnitude and show a larger difference of density values. Correction of the apparent mineral density, by a factor reflecting the proportion of vascular and resorption spaces in the cortical bone, produces a true mineral density which does not vary significantly with age in either sex. The density values obtained for the proximal humerus differ from those in the literature which represent the femur. However, they are more readily compared with the results of clinical densitometry and may have greater clinical applications.

Adult↗

Intracapsular hip fracture: increased cortical remodeling in the thinned and porous anterior region of the femoral neck.

It has been shown previously that the antero-inferior cortex is subjected to maximal tensile stress during a fall onto the greater trochanter. We have recently shown that in cases of femoral neck fracture, cortical thinning and porosity is greatest in the anterior and antero-inferior region of the femoral neck. To investigate whether this is due to increased remodeling, we have quantified surface-based parameters associated with Haversian remodeling in femoral neck biopsies from women with intracapsular hip fracture and post-mortem controls. Cryostat sections of chilled biopsies were reacted for either tartrate-resistant acid phosphatase (TRAP) or alkaline phosphatase (ALP) activity. Proportions of active canals were determined in each quadrant (inferior, anterior, superior, posterior) of the femoral neck. The biopsies were then embedded in methacrylate to permit histomorphometry using Goldner's and Solochrome sections. In the cases there was no significant increase in the proportion of canals undergoing remodeling in the cortex as a whole (p = 0.846), but the regional distribution of remodeling was markedly different from that in the controls. In the anterior cortex, the proportion of canals undergoing remodeling was increased by 56% (p = 0.0087); in contrast there was a relative decrease of 35% in the superior region (p = 0.0047). In the anterior cortex of cases there were 76% and 42% increases in the proportions of eroded (p = 0.019) and osteoid-bearing (p = 0.041) canals, respectively. In the superior region, the decrease in the proportion of remodeling sites was due to a marked decrease in canals with an osteoid surface (51%; p = 0.0031). Covariance analysis with cortical porosity as the dependent variable showed that porosity was significantly dependent on the regional distribution of eroded (p = 0.033) but not on the distribution of forming (p = 0.153) canals (R(2)adj = 0.51). Cellular levels of TRAP and ALP were significantly elevated in the anterior region of cases compared with the controls (TRAP 55%, p = 0.006; ALP 36%, p = 0.003). For the posterior and inferior regions there were no marked differences in cellular TRAP and ALP levels compared with control values. These data show that the increased cortical thinning and increased porosity we have previously observed in the anterior cortex in cases of hip fracture are associated with increased indices of Haversian remodeling. These findings are consistent with the hypothesis that, in cases of hip fracture, remodeling imbalance in the anterior cortex is a continuing process up to the time of fracture and is due to increased osteoclastic cellular activity associated with an osteoblastic response that is inadequate to prevent bone loss.

Acid Phosphatase↗

Osteocyte lacunar occupancy in the femoral neck cortex: an association with cortical remodeling in hip fracture cases and controls.

In adult humans, osteocytes die and disappear from their lacunae in the cortex of bones which remodel slowly, such as the proximal femur, and osteocyte death is particularly prevalent in the elderly. We have investigated the statistical determinants of osteocyte density in microscopic fields (0.71 mm2) within thin, complete femoral neck cross-sections cut from biopsies embedded in methyl methacrylate and stained with solochrome cyanine R. Lacunae were counted under phase contrast and osteocytes within lacunae were counted in the same fields under epifluorescence. The percentage of lacunae containing an osteocyte varied between 12.4% and 99.2%, according to subject and quadrantic region of the cortex examined. The microscopic determinants of field-specific osteocyte density included the porosity measured in the field itself and the regional measurement of the proportion of cortical canals bearing osteoid. There was significant variation between subjects and, within subjects, between cortical regions. Also the inferior region showed a significantly higher density of lacunae than the superior region (+8.2%; P = 0.013). However, cases of fracture were not significantly different from controls with respect to osteocyte lacunar occupancy after adjusting for osteoid-bearing canals and porosity. It is concluded that in subjects in their 7th-9th decades of age, osteocyte lacunar occupancy is statistically associated with bone turnover, implying that high turnover (locally young bone age) might favor lacunar occupancy (ln% osteoid; P = 0.021). Alternative explanations of the association are that porosity reflects a better nutritional supply via the vasculature or that porosity of the cortex is associated with osteocyte density through an effect of osteocytes on bone remodeling.

Aged↗

Response of cortical bone to antiresorptive treatment.

A total of 113 postmenopausal women (69 controls, 33 using hormone replacement therapy (HRT), and 11 using bisphosphonate) were evaluated twice over 2 years with a new noninvasive, radiogrammetry-based technique called digital X-ray radiogrammetry (DXR) and conventional bone densitometry of the spine, hip, and forearm. Longitudinal changes in bone densitometry were compared with changes captured by DXR: BMD evaluated by DXR (BMDDXR), cortical thickness of the second metacarpal (CTMC2), and porosity of cortical bone. The expected annual postmenopausal reduction in BMD in the control group was detected by BMDspine (-0.8%, P < 0.01), BMDhip (-1.6%, P < 0.001), BMDforearm (-1.5%, P < 0.001), DXR-BMD (-0.8%, P < 0.001), and CTMC2 (-1.1%, P < 0.001). In the HRT group, smaller reductions were seen in BMDDXA, but only significant at the hip (-1.0%, P < 0.01) and distal forearm (-1.0%, P < 0.02). In the bisphosphonate group, cortical porosity was significantly reduced (P < 0.025). Comparing longitudinal changes in age-matched subsamples of controls and bisphosphonate treated, BMDDXR, CTMC2, and porosity of cortical bone all differed significantly (P < 0.01, P < 0.05, P < 0.05, respectively), whereas the BMDDXA measurements did not. In conclusion, DXR provides a densitometry equivalent measurement of the distal forearm and hand and seems to offer new information on the porosity of cortical bone. This may prove useful in the evaluation of bone loss and offer new insight into the effects of different antiresorptive treatment regimens used in the prevention of osteoporosis.

Absorptiometry, Photon↗

In-situ hardening hydroxyapatite-based scaffold for bone repair.

Musculoskeletal conditions are becoming a major health concern because of an aging population and sports- and traffic-related injuries. While sintered hydroxyapatite implants require machining, calcium phosphate cement (CPC) bone repair material is moldable, self-hardens in situ, and has excellent osteoconductivity. In the present work, new approaches for developing strong and macroporous scaffolds of CPC were tested. Relationships were determined between scaffold porosity and strength, elastic modulus and fracture toughness. A biocompatible and biodegradable polymer (chitosan) and a water-soluble porogen (mannitol) were incorporated into CPC: Chitosan to make the material stronger, fast-setting and anti-washout; and mannitol to create macropores. Flexural strength, elastic modulus, and fracture toughness were measured as functions of mannitol mass fraction in CPC from 0% to 75%. After mannitol dissolution in a physiological solution, macropores were formed in CPC in the shapes of the original entrapped mannitol crystals, with diameters of 50 microm to 200 microm for cell infiltration and bone ingrowth. The resulting porosity in CPC ranged from 34.4% to 83.3% volume fraction. At 70.2% porosity, the hydroxyapatite scaffold possessed flexural strength (mean +/- sd; n = 6) of (2.5 +/- 0.2) MPa and elastic modulus of (0.71 +/- 0.10) GPa. These values were within the range for sintered porous hydroxyapatite and cancellous bone. Predictive equations were established by regression power-law fitting to the measured data (R(2) > 0.98) that described the relationships between scaffold porosity and strength, elastic modulus and fracture toughness. In conclusion, a new graft composition was developed that could be delivered during surgery in the form of a paste to harden in situ in the bone site to form macroporous hydroxyapatite. Compared to conventional CPC without macropores, the increased macroporosity of the new apatite scaffold may help facilitate implant fixation and tissue ingrowth.

Aging↗

Delineating bone's interstitial fluid pathway in vivo.

Although interstitial fluid flow has been suggested to play a role in bone adaptation and metabolism, the constituents and ultrastructure of this interstitial fluid pathway are not well understood. Bone's lacunar-canalicular porosity is generally believed to be a continuous interstitial fluid pathway through which osteocytes sense external mechanical loading as well as obtain nutrients and dispose of wastes. Recent electron microscopy studies have suggested that a fiber matrix surrounds the osteocytic cell processes and fills this pericellular fluid space. However, studies injecting tracer molecules into the bone vasculature have provided conflicting results about the pore size or the fiber spacing of the interstitial fluid pathway. In addition, whether the smaller collagen-apatite porosity in adult bone is also a continuous fluid pathway is still unclear. To delineate bone's interstitial fluid pathway, four tracers of various size were injected into rats: reactive red (approximately 1 nm), microperoxidase (MP, approximately 2 nm), horseradish peroxidase (HRP, approximately 6 nm), and ferritin (approximately 10 nm). Five minutes after injection, the tibiae were harvested and processed using histological protocols optimized to minimize processing time to reduce possible redistribution of tracer molecules. The number of blood vessels and osteocytic lacunae labeled with the tracers per unit bone area was then measured for mid-diaphysial cross-sections of the tibia. While none of the tracers was detected within the mineralized bone matrix (the collagen-apatite porosity) using light microscopy, all the tracers except ferritin were found to pass through the canaliculi and appear in the osteocytic lacunae. These results indicate that while small tracers (<6 nm) readily pass through the lacunar-canalicular porosity in the absence of mechanical loading, there appears to be an upper limit or cutoff size between 6 and 10 nm for molecular movement from bone capillaries to osteocytic lacunae in rat long bone. This range of pore size contains the most likely fiber spacing (approximately 7 nm) that has been proposed for the lacunar-canalicular annular space based on the presence of a proteoglycan fiber matrix surrounding the osteocyte.

Animals↗

Properties and performance of novel high-resolution/high-permeability ion-exchange media for protein chromatography.

There is continued interest in the development of stationary phases for protein chromatography that can provide high resolution at elevated flow rates of the mobile phase. When using porous particles, resolution and dynamic binding capacity decline rapidly as the flow rate is increased. Monolithic columns have been developed to overcome these limitations. However, there are difficulties in manufacturing homogeneous larger scale monoliths. In this paper we investigate the morphology and performance characteristics of columns based on new ion exchangers obtained by mechanically disrupting continuous beds of acrylamido-based polymeric media. Near colloidal suspensions of loose particles obtained with this procedure can be flow-packed in ordinary chromatography columns resulting in beds of unexpectedly high hydraulic permeability. Columns up to 2.2 cm in diameter were studied with both Q and S functionalized media. The hydraulic permeability and interparticle porosity of these columns were rather high. The permeabilities of the S and Q media were 1.5 x 10(-13) and 2.4 x 10(-13) m2, respectively, while the corresponding porosities were 60 and 70%. These porosity values are similar to those of monoliths, suggesting that these particles assemble under flow to give high-porosity bridged structures. The structure of these packed beds was further characterized by embedding small packed columns in resins and obtaining sections for microscopic observation. The sections reveal the presence of small aggregates of non-porous 1-3 microm particles, surrounded by flow channels several micrometers in size. The height equivalent to a theoretical plate under isocratic and gradient elution conditions and the dynamic binding capacity were determined for several proteins and were found to be virtually independent of flow.

Chromatography, Ion Exchange↗

Hydrodynamic aspects of slurry packing processes in microcolumn liquid chromatography.

A Stokesian dynamics computer simulation based method is presented for the estimation of the bed porosity of slurry-packed capillary liquid chromatography (LC) columns. A colloidally well-described reversed-phase stationary phase-slurry liquid suspension was used as a model system. The applied simulation method takes into account the velocity of the slurry and colloidal interaction forces, as well as inter-particle hydrodynamic interactions. The predicted bed porosities suggest that a lower slurry velocity leads to a denser packing structure due to the increased effect of colloidal repulsion effects. The results of the simulations were compared with the external porosity and chromatographic performance of capillary LC columns that were packed at different filtration and compaction pressures. However, the trends that were observed in the experimental results suggest that hydrodynamic packing parameters have no or little effect on the chromatographic performance of capillary LC columns. Within the experimental parameter window, the chromatographic performance and the column porosity were not influenced by the filtration and compaction pressure, nor by the duration of the compaction process.

Chromatography, Liquid↗