Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Comprehensive two-dimensional separation system by coupling capillary reverse-phase liquid chromatography to capillary isoelectric focusing for peptide and protein mapping with laser-induced fluorescence detection.

A comprehensive two-dimensional (2-D) separation system, coupling capillary reverse-phase liquid chromatography (cRPLC) to capillary isoelectric focusing (CIEF), is described for protein and peptide mapping. cRPLC, the first dimension, provided high-resolution separations for salt-free proteins. CIEF, the second dimension with an orthogonal mechanism to cRPLC afforded excellent resolution capability for proteins with efficient protein enrichment. Since all sample fractions in cRPLC effluents could be transferred to the CIEF dimensions, the combination of the two high-efficiency separations resulted in maximal separation capabilities of each dimension. Separation effectiveness of this approach was demonstrated using complex protein/peptide samples, such as yeast cytosol and a BSA tryptic digest. A peak capacity of more than 10 000 had been achieved. A laser-induced fluorescence (LIF) detector, developed for this system, allowed for high-sensitive detection, with a fmol level of peptide detection for the BSA digest. FITC and BODIPY maleimide were used to tag the proteins, and the latter was found better both for separation and detection in our 2-D system.

Boron Compounds↗

Sequencing of real-world samples using a microfabricated hybrid device having unconstrained straight separation channels.

We describe a microfabricated hybrid device that consists of a microfabricated chip containing multiple twin-T injectors attached to an array of capillaries that serve as the separation channels. A new fabrication process was employed to create two differently sized round channels in a chip. Twin-T injectors were formed by the smaller round channels that match the bore of the separation capillaries and separation capillaries were incorporated to the injectors through the larger round channels that match the outer diameter of the capillaries. This allows for a minimum dead volume and provides a robust chip/capillary interface. This hybrid design takes full advantage, such as sample stacking and purification and uniform signal intensity profile, of the unique chip injection scheme for DNA sequencing while employing long straight capillaries for the separations. In essence, the separation channel length is optimized for both speed and resolution since it is unconstrained by chip size. To demonstrate the reliability and practicality of this hybrid device, we sequenced over 1000 real-world samples from Human Chromosome 5 and Ciona intestinalis, prepared at Joint Genome Institute. We achieved average Phred20 read of 675 bases in about 70 min with a success rate of 91%. For the similar type of samples on MegaBACE 1000, the average Phred20 read is about 550-600 bases in 120 min separation time with a success rate of about 80-90%.

Animals↗

Preparative-scale, recirculating, pH-biased binary isoelectric trapping separations.

In order to improve the production rates and lower the specific electrophoretic energy consumption values in preparative-scale, recirculating, binary isoelectric trapping separations, we propose to add an auxiliary isoelectric agent to the solution in the anodic separation compartment and another to the solution in the cathodic separation compartment to implement pH-biased isoelectric trapping. The auxiliary isoelectric agents are selected such that they are trapped in the respective anodic and cathodic separation compartments and also, have isoelectric point (pI) values that are different from the pI values of the analytes of interest. By proper selection of the auxiliary isoelectric agents and their concentrations, the analytes of interest can be kept in nonisoelectric, charged state during the entire course of the preparative-scale, recirculating, binary isoelectric trapping separation. This results in higher electrophoretic mobilities and solubilities for the analytes than in their isoelectric or near-isoelectric states, and leads to faster binary isoelectric trapping separations.

Animals↗

Improved separation of palladium species in biological matrices by using a combination of gel permeation chromatography and isotachophoresis.

The binding of palladium to high-molecular-mass compounds in palladium-treated lettuce is investigated as an example for a biological matrix. The total palladium concentration in lettuce leaves is 10.3 ng/g wet weight. After homogenization, high-molecular-mass compounds (> 10 kDa) are isolated by ultrafiltration. For separation of these palladium species a combination of preparative gel permeation chromatography (GPC) and preparative isotachophoresis (ITP) is used. Palladium is determined in separated fractions by using a highly sensitive total reflection X-ray fluorescence (TXRF) method after preconcentration. After GPC separation, four main fractions of palladium species are collected, each containing palladium in ng quantities (3-10 ng). Two of these fractions are further separated by ITP, yielding at least three main peaks per GPC fraction, each containing palladium in the range of 0.3-3 ng. These palladium containing peaks are characterized by high-performance size exclusion chromatography (HPSEC) and capillary isotachophoresis (cITP) in parallel. HPSEC enables the estimation of the molecular mass of six main palladium peaks, covering a molecular mass range of 69-200 kDa. It is also shown that the estimation of molecular mass after separation is more reliable than the respective estimation directly in the first GPC run. However, cITP reveals that each of the separated peaks is still a mixture of at least five different compounds.

Chromatography, Gel↗

Separation of double-stranded DNA fragments by capillary electrophoresis: Impacts of poly(ethylene oxide), gold nanoparticles, ethidium bromide, and pH.

The separation of DNA by capillary electrophoresis using poly(ethylene oxide) (PEO) containing gold nanoparticles (GNPs) is presented. The impacts of PEO, GNPs, ethidium bromide (EtBr), and pH on the separation of double-stranded DNA have been carefully explored. Using a capillary dynamically coated with 5.0% poly(vinylpyrrolidone) and filled with 0.2% PEO containing 0.3 x GNPs (the viscosity less than 15 cP), we have demonstrated the separation of DNA markers V and VI within 5 min at pH 8.0 and 9.0. In terms of resolution and reproducibility, GNPs have a greater impact on the separation of DNA at pH 9.0. Resolution improvements for large DNA fragments (> 300 base pairs, bp) are greater than those for small ones in the presence of GNPs. It is important to point out that reproducibility is excellent (relative standard deviations for the migration times less than 0.5%) and thus no further dynamic coating is required in at least 20 consecutive runs in the presence of GNPs. Using 0.2% PEO (pH 9.0) containing 0.3 x GNPs, the separation of DNA fragments ranging in size from 21 to 23,130 bp was accomplished in 7 min. The results presented in this study show the advantage of PEO containing GNPs for DNA separation, including rapidity, high resolving power, excellent reproducibility, and ease of filling capillaries.

DNA↗

Subsecond chiral separations on a microchip.

Fast chiral separation of DNS-amino acids could be realized using microchip electrophoresis with fluorescence detection. For this purpose, highly sulfated cyclodextrins (HS-gamma-CD) were used as chiral selectors enabling high selectivity. Even subsecond separation of DNS-tryptophan, DNS-norleucine, DNS-phenylalanine, DNS-methionine, and DNS-aspartic acid could be achieved. Baseline separation could be accomplished within 720 ms, which is the fastest separation of enantiomers reported to date. A more complex mixture consisting of three chiral DNS-amino acids could be separated within 3.3 s utilizing a separation length of only 7 mm and an electrical field strength of 2012 V/cm.

Amino Acids↗

Preparative-scale fractionation by isoelectric trapping under nondenaturing conditions: separation of egg white protein isoforms on a modified Gradiflow unit.

pH-biased isoelectric trapping was used to separate proteins from egg white at the preparative level (80 mg), into discrete protein fractions based on isoelectric point. The problems of isoelectric precipitation that are common for the separation of complex protein mixtures under isoelectric conditions were mitigated by using single-component isoelectric buffers within the sample separation compartments. This combined with the mild process conditions of the Gradiflow unit that was modified for binary isoelectric trapping separations, ensured that biological activity was maintained. This was verified by measurement of the trypsin protease inhibitory activity of the extract and separated fractions. Furthermore, the high resolving power of this system under preparative conditions was demonstrated by separation of three protein isoforms using isoelectric membranes with differences of 0.025 pH units from each other.

Animals↗

Peak compression and resolution for electrophoretic separations in diverging microchannels.

We report the results of experiments and simulations on electrokinetic flow in diverging microchannels (with cross-sectional area that increases with distance along the channel). Because of conservation of mass and charge, the velocity of an analyte in the channel decreases as the channel cross-section increases. Consequently, the leading edge of a band of sample moves more slowly than the trailing edge and the sample band is compressed. Sample peak widths, rather than increasing diffusively with time, can then be controlled by the geometry of the channel and can even be made to decrease with time. We consider the possibility of using this peak compression effect to improve the resolution of electrophoretic separations. Our results indicate that for typical separations that are dispersion limited, this peak compression effect is more than offset by the decreased distance between peaks, and the separation resolution in diverging channels is worse than that found for straight channels at the same applied voltage. For separations in very short channels or at very high field strengths, however, when the separation efficiency is injection limited, the peak compression effect is dominant and diverging channels can then be used to achieve improved separation resolution.

Electrophoresis, Microchip↗

Static adsorptive coating of poly(methyl methacrylate) microfluidic chips for extended usage in DNA separations.

A simple and robust static adsorptive (dynamic) coating process using 2% hydroxyethylcellulose was developed for surface modification of poly(methyl methacrylate) (PMMA) microfluidic chips for DNA separations, suitable for usage over extended periods, involving hundreds of runs. The coating medium was also used as a sieving matrix for the DNA separations following the coating process. Four consecutive static treatments, by simply filling the PMMA chip channels with sieving matrix once every day, were required for obtaining a stable coating and optimum performance. The performance of the coated chips at different phases of the coating process was studied by consecutive gel electrophoretic separations with LIF detection using a PhiX-174/HaeIII DNA digest sample. The coated chip, with daily renewal of the sieving matrix, showed high stability in performance during a 25-day period of systematic study, involving more than 100 individual runs. The performance of the coated chip also remained almost the same after 3 months of continuous usage, during which over 200 separations were performed. The average precision of migration time for the 603-bp fragment was 1.31% RSD (n = 6) during the 25-day study, with a separation efficiency of 6.5 x 10(4) plates (effective separation length 5.4 cm).

Adsorption↗

Two-dimensional separation system of coupling capillary liquid chromatography to capillary electrophoresis for analysis of Escherichia coli metabolites.

A two-dimensional (2-D) separation system of coupling chromatography to electrophoresis was developed for profiling Escherichia coli metabolites. Capillary liquid chromatography (LC) with a monolithic silica-octadecyl silica column (500 x 0.2 mm ID) was used as the first dimension, from which the effluent fractions were further analyzed by capillary electrophoresis (CE) acting as the second dimension. Field-enhanced stacking was selectively employed as a concentration strategy to interface the two dimensions, which proved to be beneficial for the detection of metabolites. An artificial sample containing 118 standards, some of which lack chromophores or have weak UV absorbance, was used to optimize the 2-D separation system. Under the optimum conditions, 63 components in the artificial sample having absorbance at 254 nm could be well resolved and detected. The utility of the system was demonstrated by comprehensive analysis of E. coli metabolites. Comparing with the previous 2-D separation system we published in Anal. Chem. 2004, 76, 1419-1428, using a longer monolithic column in the first dimension improved the separation efficiency and offered the possibility of increasing the injection volume without compromising the separation efficiency. In the second dimension, field-enhanced stacking was used to improve the concentration sensitivity of the metabolites, and more metabolites in E. coli cell extract were detected and identified using the developed 2-D separation system. In addition, preliminary investigation for future CE-mass spectrometry coupling was also made in the study by using volatile buffers in the capillary LC and CE techniques.

Amino Acids↗

Monolithic silica capillary column with coated cellulose tris(3,5-dimethylphenylcarbamate) for capillary electrochromatographic separation of enantiomers.

Monolithic silica capillary columns were prepared by a sol-gel process in fused-silica capillaries with an inner diameter of 50 microm and were modified by coating of cellulose tris(3,5-dimethylphenylcarbamate). Influences of the factors in the modification process on enantiomer separations were investigated. The prepared columns were used to perform enantiomer separations by CEC. Fifteen and two pairs of enantiomers were separated under aqueous and nonaqueous mobile phases, respectively, and most of them were baseline-separated with very high column efficiencies. The Van Deemter curve was found flat under high linear velocity of the mobile phase, which indicated favorable kinetic properties of the prepared columns. Baseline separation of a pair of enantiomers was achieved in 90 s with high-column efficiency by short-end separation under high voltage.

Cellulose↗

Evaluation of sieving matrices used to separate alleles by cycling temperature capillary electrophoresis.

Denaturing CE (DCE) is a powerful tool for analysis of DNA variation. The development of commercial multi-CE instruments allows large-scale studies of DNA variation (many samples and many fragments). However, the cost of consumables like capillary arrays and sieving matrix might limit the use of DCE in such studies. Thus, we have tested 72 different in-house formulated sieving matrices' ability to suppress EOF and separate PCR-amplified alleles with the DCE variant, cycling temperature CE (CTCE). The data herein demonstrate that alleles can be baseline-separated by use of PVP and poly(N,N-dimethyl acrylamide) polymers at various percentages and pH. Allele separation by CTCE is matrix-independent and consequently applicable to any capillary instrument used for DNA separation. Formulation of sieving matrix for CTCE was done by dissolving appropriate amount of polymer powder into the running buffers. Allele separation was observed at different pH (7.5-8.5), concentrations and molecular size of the polymer, without compromising the separation and reproducibility. Finally, the cost reduction of homemade matrices is more than 1000-fold as compared to commercial sieving matrices.

Acrylic Resins↗

Separation of cationic polymer particles and characterization of avidin-immobilized particles by capillary electrophoresis.

Cationic polymer microparticles have received much attention especially in the field of biotechnology, such that their analysis and separation have become important. So far, the separation of cationic polymer particles with different size using CE has not been achieved and the cationic particles migrated as if they are negatively charged, probably due to electrostatic interaction between capillary wall and cationic polymer particles. In this paper, the separation of cationic polymer microparticles by CE was investigated in detail. The separation of cationic particles with different size was achieved in CE by taking into account the interaction between sample particles and the inner surface of capillaries. By employing a poly(vinyl alcohol)-coated capillary, a better size separation of amine-modified latex particles was obtained compared to a Polybrene-coated capillary. It was elucidated that the composition, concentration, and pH of the background solution were also important factors in the separation of colloidal particles to avoid the surface adsorption and the characteristic aggregation of polymer particles. Furthermore, the CE analysis was applied to the characterization of cationic protein-immobilized particles.

Avidin↗

Effects of separation length and voltage on isoelectric focusing in a plastic microfluidic device.

This paper describes the investigation on the effects of separation length and voltage on IEF in a plastic microfluidic device. A LIF, whole-channel imaging detection (WCID) system was developed to monitor proteins while they were moving under an electric field. IEF was carried out in a separation medium consisting of carrier ampholytes and a mixture of linear polymers (hydroxyethylcellulose and hydroxypropylcellulose). We found that the IEF separation resolution is essentially independent of separation length when the same voltage is applied, which agrees with the theory. This result supports the notion that IEF in a microfabricated device leads to more rapid analysis without sacrificing the resolving power. A higher separation voltage also brought about more rapid analysis and superior separation resolution. IEF of two proteins (green fluorescence protein and R-phycoerythrin) was achieved in 1.5 min when 500 V was applied across a 1.9-cm channel. We found that a linear relationship exists between the focusing time and the inverse of the electrical field strength. In addition, we confirmed the phenomenon in which the pH gradient was compressed to the middle of a channel, and we found that the relative amount of the gradient compression decreased with the channel length.

Electricity↗

Use of multivariate analysis for optimization of separation parameters and prediction of migration time, resolution, and resolution per unit time in micellar electrokinetic chromatography.

The optimization of separation parameters in chromatography for better separation and resolution of analytes continues to be a labor intensive procedure usually performed by a trial and error method. A multivariate analysis in the form of multilinear regression (MLR) is used to optimize separation parameters and predict the migration behavior, resolution, and resolution per unit time of achiral (4-chlorophenol, pentachlorophenol, clonazepam, and diazepam) and chiral (1,1'-binaphthyl 2,2'-dihydrogen phosphate (BNP), and 1,1'-bi-2-naphthol (BOH)) compounds in MEKC. Separations of achiral and chiral analytes were performed using an achiral (poly(sodium N-undecylenic sulfate)) molecular micelle and chiral (poly(sodium N-undecanoyl-L-leucylvalinate) or poly(sodium N-undecanoyl-L-isoleucylvalinate)) molecular micelle, respectively, at various operating temperatures, applied voltages, pH values, and molecular micelle concentrations in the BGE. The separation parameters were subsequently used as input variables for MLR models. The models were validated with independent samples. The root-mean-square percent relative error (RMS%RE) is used as a figure of merit for characterizing the performance of the migration time, resolution, and resolution per unit time models. The RMS%RE obtained for predicted migrated times, resolutions, and resolution per unit time of 4-chlorophenol, pentachlorophenol, clonazepam, diazepam, BNP, and BOH ranged between 8 and 19%. The same experimental procedure was used to optimize the separation parameters of six other chiral analytes of different compound class. The predicted migration times, resolutions, and resolution per unit time of the chiral as well as the achiral analytes compare favorably with the experimental migration times and resolutions, indicating versatility and wide applicability of the technique in MEKC.

Chromatography, Micellar Electrokinetic Capillary↗

Reversed-phase liquid chromatographic separation of enantiomeric and diastereomeric bases related to chloramphenicol and thiamphenicol.

The important antimicrobial agents chloramphenicol and thiamphenicol are N-acylated amines whose chemical structures include two chiral centers. Each drug is the single enantiomer of R,R configuration. The N-deacylated bases of the drugs are important intermediates in their synthesis and optical resolution. In this report, reversed-phase HPLC methods are described for the separation of enantiomeric and diastereomeric bases of the two drugs and of two closely related bases used in some syntheses of the drugs. The stereoisomeric bases were derivatized with a homochiral isothiocyanate and the resulting diastereomeric thioureas were separated on C18 columns with methanol:water mixtures as mobile phases and detection at 254 nm. The four stereoisomeric bases of chloramphenicol and those of its unnitrated analogue were thus separable after derivatization with 2,3,4,6-tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate. This reagent also allowed the separation of the D-threo isomer of the p-mercaptomethyl analogue of thiamphenicol base from its stereoisomers. The stereoisomers of thiamphenicol base were similarly separated with (R)-alpha-methylbenzyl isothiocyanate as the derivatizing agent. The diastereomers of chloramphenicol base and of thiamphenicol base were chromatographically separable after derivatization with the nonchiral reagent benzyl isothiocyanate. The procedures developed may be useful in the determination of the stereoisomeric composition of the drugs in research and in quality control, and may be applicable to other similar agents whose chemistry and pharmacology are receiving considerable attention.

Capsules↗

On the potential of electrochemically modulated liquid chromatography of proteins in a micro open parallel plate separator.

Electrochemically Modulated Liquid Chromatography (EMLC) is a technique in which an electrical potential is applied to the stationary phase in order to alter its adsorptive properties. The micro Open Parallel Plate Separator (microOPPS) is an open-channel micro-chromatographic system with the unique characteristic of an adjustable rectangular flow cross-section. In this publication, the performance of the microOPPS in the EMLC mode was simulated using a comprehensive mathematical model. The separation of two proteins was analyzed by performing a parametric study for the effects of the potential applied to the stationary phase, the dimensions of the device, and the operating conditions. It is shown that the combination of the microOPPS and EMLC is promising for protein separations. These separations can be optimized by carefully selecting the applied potential and the geometry of the microOPPS. The marriage of the microOPPS and EMLC adds two additional dimensions for control, to improve the separation efficiency in analytical applications and in preparative separations of trace compounds.

Chromatography, Liquid↗

Two-dimensional and serial column reversed-phase separation of phenolic antioxidants on octadecyl-, polyethyleneglycol-, and pentafluorophenylpropyl-silica columns.

The separation selectivity of octadecyl-silica (C18) and of bonded pentafluorophenylpropyl-silica (F5) and PEG-silica columns was compared for natural phenolic antioxidants. The separation selectivities for phenolic antioxidants on C18 and F5 columns are strongly correlated, but low selectivity correlation indicating strong differences in the retention mechanism was observed between the C18 and PEG columns. Hence, the combination of a C18 and a PEG column is useful for separation of phenolic antioxidants that are not fully separated on single columns. Two-dimensional comprehensive liquid chromatography using a short PEG-silica column in the first dimension and a conventional C18-silica in the second dimension has the advantage of on-column focusing of the fractions transferred onto the C18 column in the second dimension, as a weaker mobile phase is used in the first dimension than in the second dimension. However, a stop-flow set-up in the first dimension system is necessary after the transfer of each fraction to the second dimension. Peak capacity is considerably larger but the separation time is much longer than with serially coupled PEG and C18 columns, which were employed for separation of beer and hop extract samples in connection with coulometric detection.

Antioxidants↗