Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Parallel reactions in open chip-based nanovials with continuous compensation for solvent evaporation.

In an earlier report (Litborn, E., Emmer, A., Roeraade, J., Anal. Chim. Acta 1999, 401, 11-19, we described a technique for performing chemistry in chip-based vials. A major problem, solvent evaporation, was partially remedied by using a closed humidity chamber. In this paper we report an improved technique for performing parallel reactions in open, 15 nL volume, chip-based vials. The evaporation of solvent from the reaction fluid was continuously compensated by addition of solvent via an array of microcapillaries. The suitability of the method was demonstrated by performing eight separate peptide maps of myoglobin in parallel, using the three enzymes trypsin, alpha-chymotrypsin and endoproteinase Glu-C. The total amount of myoglobin utilized to perform the eight digests was less than 100 pmol. The corresponding amount of enzymes was ca. 0.1 pmol per reaction. In order to evaluate the operating limits of the technique, a study of the evaporation of solvents from a series of vials with proportionally smaller volumes operated at different temperatures was performed. The results showed that the concept for continuous compensation of solvent evaporation should be applicable to reaction volumes down to 30 pL.

Animals↗

Integration of immobilized trypsin bead beds for protein digestion within a microfluidic chip incorporating capillary electrophoresis separations and an electrospray mass spectrometry interface.

A microfluidic device is described in which an electrospray interface to a mass spectrometer is integrated with a capillary electrophoresis channel, an injector and a protein digestion bed on a monolithic substrate. A large channel, 800 microm wide, 150 microm deep and 15 mm long, was created to act as a reactor bed for trypsin immobilized on 40-60 microm diameter beads. Separation was performed in channels etched 10 microm deep, 30 microm wide and about 45 mm long, feeding into a capillary, attached to the chip with a low dead volume coupling, that was 30 mm in length, with a 50 microm i.d. and 180 microm o.d. Sample was pumped through the reactor bed at flow rates between 0.5 and 60 microL/min. The application of this device for rapid digestion, separation and identification of proteins is demonstrated for melittin, cytochrome c and bovine serum albumin (BSA). The rate and efficiency of digestion was related to the flow rate of the substrate solution through the reactor bed. A flow rate of 1 or 0.5 microL/min was found adequate for complete consumption of cytochrome c or BSA, corresponding to a digestion time of 3-6 min at room temperature. Coverage of the amino acid sequence ranged from 92% for cytochrome c to 71% for BSA, with some missed cleavages observed. Melittin was consumed within 5 s. In contrast, a similar extent of digestion of melittin in a cuvet took 10-15 min. The kinetic limitations associated with the rapid digestion of low picomole levels of substrate were minimized using an integrated digestion bed with hydrodynamic flow to provide an increased ratio of trypsin to sample. This chip design thus provides a convenient platform for automated sample processing in proteomics applications.

Animals↗

Capillary electrophoresis with on-chip four-electrode capacitively coupled conductivity detection for application in bioanalysis.

Microchip capillary electrophoresis (CE) with integrated four-electrode capacitively coupled conductivity detection is presented. Conductivity detection is a universal detection technique that is relatively independent on the detection pathlength and, especially important for chip-based analysis, is compatible with miniaturization and on-chip integration. The glass microchip structure consists of a 6 cm etched channel (20 microm x 70 microm cross section) with silicon nitride covered walls. In the channel, a 30 nm thick silicon carbide layer covers the electrodes to enable capacitive coupling with the liquid inside the channel as well as to prevent interference of the applied separation field. The detector response was found to be linear over the concentration range from 20 microM up to 2 mM. Detection limits were at the low microM level. Separation of two short peptides with a pI of respectively 5.38 and 4.87 at the 1 mM level demonstrates the applicability for biochemical analysis. At a relatively low separation field strength (50 V/cm) plate numbers in the order of 3500 were achieved. Results obtained with the microdevice compared well with those obtained in a bench scale CE instrument using UV detection under similar conditions.

Calibration↗

Adapting arrays and lab-on-a-chip technology for proteomics.

The impact of proteomics as a discovery engine in life science and in drug discovery has increased tremendously over the last seven years. At the same time, proteomics has expanded from the initial trust as a two-dimensional gel based approach to cover more functional and structural properties of proteins. The development of lab-on-a-chip and protein arrays for proteomics will have to evolve with the changes in proteomics to stay relevant. Here, we review the changes in the field of proteomics and their impact on the development in protein arrays and lab-on-a-chip.

Antibodies↗

Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Miniaturization↗

Chemiluminescence microflow injection analysis system on a chip for the determination of uric acid without enzyme.

A new microflow injection analysis (microFIA) system on a chip coupled with chemiluminescence (CL) for the non-enzymatic determination of uric acid is described. The microFIA system produced by using two transparent poly(methylmethacrylate) (PMMA) chips measured 50 x 40 x 5 mm, the microchannels, etched by CO2 laser, were 200 microm wide and 100 microm deep, and the volume of the reaction area (RA) was about 1.2 microL. The injection pump, with accurate time control, monitored all reagents, including the sample. The uric acid was sensed by the chemiluminescence reaction between luminol and ferricyanide. The linear range of the uric acid concentration was 0.8-30 mg/L and the detection limit was 0.5 mg/L (S/N = 3). The relative standard deviation was 4.42% for 5 mg/L uric acid (n = 8). The proposed method has been successfully applied to the non-separation determination of uric acid in human serum and urine.

Ferricyanides↗

Oligonucleotide-arrayed TFT photosensor applicable for DNA chip technology.

A thin film transistor (TFT) photosensor fabricated by semiconductor integrated circuit (IC) technology was applied to DNA chip technology. The surface of the TFT photosensor was coated with TiO2 using a vapor deposition technique for the fabrication of optical filters. The immobilization of thiolated oligonucleotide probes onto a TiO2-coated TFT photosensor using gamma-aminopropyltriethoxysilane (APTES) and N-(gamma-maleimidobutyloxy) sulfosuccinimide ester (GMBS) was optimized. The coverage value of immobilized oligonucleotides reached a plateau at 33.7 pmol/cm2, which was similar to a previous analysis using radioisotope-labeled oligonucleotides. The lowest detection limits were 0.05 pmol/cm2 for quantum dot and 2.1 pmol/cm2 for Alexa Fluor 350. Furthermore, single nucleotide polymorphism (SNP) detection was examined using the oligonucleotide-arrayed TFT photosensor. A SNP present in the aldehyde dehydrogenase 2 (ALDH2) gene was used as a target. The SNPs in ALDH2*1 and ALDH2*2 target DNA were detected successfully using the TFT photosensor. DNA hybridization in the presence of both ALDH2*1 and ALDH2*2 target DNA was observed using both ALDH2*1 and ALDH2*2 detection oligonucleotides-arrayed TFT photosensor. Use of the TFT photosensor will allow the development of a disposable photodetecting device for DNA chip systems.

Biosensing Techniques↗

Polyurethane foam chips combined with liquid chromatography in the determination of unmetabolized polycyclic aromatic hydrocarbons excreted in human urine.

A method suitable for the determination of unmetabolized polycyclic aromatic hydrocarbons (PAHs) excreted at trace levels (ng/L) in human urine for the monitoring of exposure of the general population to PAH contamination was developed. PAHs were determined, after enrichment by solid-phase extraction on polyurethane foam (PUF) chips, by HPLC with fluorescence detection. Different parameters affecting analyte extraction to the PUF, including urine salting-out and organic additives, and optimization of conditions for clean-up and desorption have been investigated. Optimized conditions were 40 mL acidified urine sample, added with magnesium sulfate, tetrahydrofuran and a 2 cm3 PUF chip, and extracted by shaking at 30 rpm for 1 h at ambient temperature. Desorption was performed, after a clean-up step with diluted sodium hydroxide, using a small amount of diethyl ether. The recovery of PAH congeners from spiked urines was >90% in the 2-100 ng/L range; the detection limit was 0.1-0.5 ng/L, depending on the considered PAH congener; day-to-day precision, at 50 ng/L native PAH content, was CV = 10-20%. The proposed technique provides a simple, economical and effective procedure for the determination of trace amounts of unmetabolized PAHs excreted in human urine spot samples.

Calibration↗

Single-cell analysis of yeast, mammalian cells, and fungal spores with a microfluidic pressure-driven chip-based system.

BACKGROUND: Cytomics aims at understanding the function of cellular systems by analysis of single cells. Recently, there has been a growing interest in single cell measurements being performed in microfluidic systems. These systems promise to integrate staining, measurement, and analysis in a single system. One important aspect is the limitation of allowable cell sizes due to microfluidic channel dimensions. Here we want to demonstrate the broad applicability of microfluidic chip technology for the analysis of many different cell types. METHODS: We have developed a microfluidic chip and measurement system that allows flow cytometric analysis of fluorescently stained cells from different organisms. In this setup, the cells are moved by pressure-driven flow inside a network of microfluidic channels and are analyzed individually by fluorescence detection. RESULTS: We have successfully applied the system to develop a methodology to detect viable and dead cells in yeast cell populations. Also, we have measured short interfering RNA (siRNA) mediated silencing of protein expression in mammalian cells. In addition, we have characterized the infection state of Magnaportae grisea fungal spores. CONCLUSIONS: Results obtained with the microfluidic system demonstrate a broad applicability of microfluidic flow cytometry to measurement of various cell types.

Cell Line↗

Integrated chip-based capillary electrophoresis.

Integrated capillary electrophoresis (ICE) is emerging as a new analytical tool allowing fast, automated, miniaturized and multiplexed assays, thus meeting the needs of the pharmaceutical industry in drug development. The current state-of-the-art of ICE is described with an emphasis on the choice of the support material (glass or polymeric materials), electrokinetic fluid handling, and injection and detection issues. Strategies and chip designs for pre- or post-column derivatization, DNA sequencing, on-line PCR analysis, on-chip enzymatic sample digestion, fraction isolation, and immunoassays are presented. The review concludes with a brief outlook.

Animals↗

Thousandfold signal increase using field-amplified sample stacking for on-chip electrophoresis.

Field-amplified sample stacking (FASS) leverages conductivity gradients between a volume of injected sample and the background buffer to increase sample concentration. A major challenge in applying FASS to on-chip assays is the initial setup of high-conductivity gradient boundaries in the region of the injected sample volume. We have designed, fabricated, and characterized a novel FASS-capillary electrophoresis (CE) chip design that uses a photoinitiated porous polymer structure to facilitate sample injection and flow control for high-gradient FASS. This polymer structure provides a region of high flow resistance that allows the electromigration of sample ions. We have demonstrated an electropherogram signal increase by a factor of 1100 in electrophoretic separations of fluorescein and Bodipy with, respectively, 2 microM and 1 microM initial concentrations.

Electrophoresis, Capillary↗

Parallel processing in the isoelectric focusing chip.

Investigation of isoelectric focusing (IEF) kinetics has been performed to provide the theoretical basis for miniaturization of classical IEF in immobilized pH-gradients. Standard IEF demands colinearity of the electric field and pH-gradient directions (serial devices). It is shown that the IEF separation process based on a continuous, serial pH gradient is incompatible with miniaturization of separation devices. The new realization of the IEF device by a parallel IEF chip is suggested and analyzed. The main separation tool of the device is a dielectric membrane (chip) with conducting channels that are filled by Immobiline gels of varying pH. The membrane is held perpendicular to the applied electric field and proteins are collected (trapped) in the channels whose pH are equal to the pI of the proteins. The pH value of the surrounded aqueous solution is not equal to any channel's pH. The fast particle transport between different channels takes place due to convection in the aqueous solution. The new device geometry introduces two new spatial scales to be considered: the scale of transition region from a solution to the gel in a channel and a typical channel size. The corresponding time scales defining the IEF process kinetics are analyzed and scaling laws are obtained. It is shown both theoretically and experimentally that parallel IEF accelerates the fractionation of proteins by their pI down to several minutes and enables possible efficient sample collection and purification.

Hydrogen-Ion Concentration↗

Contactless conductivity detection of selected organic ions in on-chip electrophoresis.

The detection of underivatized anionic sulfonates, carboxylates, amino acids, sugars, and artificial sweeteners, and of cationic dopamine, ephedrine, and metanephrine in microfabricated electrophoresis devices is demonstrated. This was achieved by high-voltage contactless conductivity measurements with external electrodes. Poly(methyl methacrylate) chips with thin covers to enable sensitive contactless detection were used for most determinations but glass microchips had to be employed for amino acids and sugars. The plastic chips were found not be stable in the alkaline media required to render those two classes of species in the ionic form amenable for separation and detection. The reproducibility of peak area measurements was about 1% or better and the detection limits ranged between 1 and 30 microM for the different compounds examined.

Alkanesulfonates↗

On-chip potential gradient detection with a portable capillary electrophoresis system.

A portable chip-CE system with potential gradient detection (PGD) was developed and applied to the determinations of alkali metals and alkaloids. The separation efficiency appeared to be satisfactory and nonaqueous capillary electrophoresis (NACE) proved to be applicable to PGD or conductivity detection. The power supplies, separation and detection were built on a device of 3 kg in weight. A branch channel near the end of the separation channel was designed to perform PGD and make the application of relatively high field strength possible. The study is the first report on the application of PGD on the microchip platform. The design of the chip-CE system shows several advantages, such as simplicity, miniaturization and wide applicability.

Alkaloids↗

Integrated on-chip derivatization and electrophoresis for the rapid analysis of biogenic amines.

We demonstrate the monolithic integration of a chemical reactor with a capillary electrophoresis device for the rapid and sensitive analysis of biogenic amines. Fluorescein isothiocyanate (FITC) is widely employed for the analysis of amino-group containing analytes. However, the slow reaction kinetics hinders the use of this dye for on-chip labeling applications. Other alternatives are available such as o-phthaldehyde (OPA), however, the inferior photophysical properties and the UV lambdamax present difficulties when using common excitation sources leading to a disparity in sensitivity. Consequently, we present for the first time the use of dichlorotriazine fluorescein (DTAF) as a superior in situ derivatizing agent for biogenic amines in microfluidic devices. The developed microdevice employs both hydrodynamic and electroosmotic flow, facilitating the creation of a polymeric microchip to perform both precolumn derivatization and electrophoretic analysis. The favorable photophysical properties of the DTAF and its fast reaction kinetics provide detection limits down to 1 nM and total analysis times (including on-chip mixing and reaction) of <60 s. The detection limits are two orders of magnitude lower than current limits obtained with both FITC and OPA. The optimized microdevice is also employed to probe biogenic amines in real samples.

Biogenic Amines↗

High-resolution DNA separation in microcapillary electrophoresis chips utilizing double-L injection techniques.

An experimental and numerical investigation into the use of high-resolution injection techniques to separate DNA fragments within electrophoresis microchips is presented. The principal material transport mechanisms of electrokinetic migration, fluid flow, and diffusion are considered, and several variable-volume injection methods are discussed. A detailed analysis is provided of a double-L injection technique, which employs appropriate electrokinetic manipulations to reduce sample leakage within the microchip. The leakage effect in electroosmotic flow (EOF) is investigated using a sample composed of rhodamine B and Cy3 dye. Meanwhile, the effects of sample leakage in capillary electrophoresis (CE) separation are studied by considering the separation of 100-base pairs (bp) DNA ladders and HaeIII-digested PhiX-174 DNA samples. The present experimental and simulation results indicate that the unique injection system employed in the current microfluidic chip has the ability to replicate the functions of both the conventional cross-channel and the shift-channel injection systems. Furthermore, applying the double-L injection method to these two injection systems is shown to reduce sample leakage significantly. The proposed microfluidic chip and double-L injection technique developed in this study have an exciting potential for use in high-resolution, high-throughput biochemical analysis applications and in many other applications throughout the micrototal analysis systems field.

DNA↗

Development of a chip-based capillary gel electrophoresis method for quantification of a half-antibody in immunoglobulin G4 samples.

A method based on microfluidic technology was developed to support quantitative analysis of recombinant monoclonal immunoglobulin G4 (IgG4) antibody samples. The assay was performed on an Agilent 2100 Bioanalyzer in combination with the Protein 200 Plus LabChip Kit and the Protein 200 Plus assay software. Capillary electrophoresis principles have been transferred to a chip format that integrates all separation, staining, virtual destaining, and detection steps. The method is referred to in this paper as chip-based capillary gel electrophoresis (GelChip-CE method). The GelChip-CE method under nonreducing conditions proved to be a quantitative test for half-antibody determination in IgG4 samples. Similar to the traditional nonreducing sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) method, the GelChip-CE method includes a denaturing step prior to separation. We showed that denaturing the sample by heating resulted in an artificial increase in the amount of half-antibody detected, which could be prevented by addition of N-ethylmaleimide to the sample buffer. The GelChip-CE method allowed for analysis of IgG4 samples with more accuracy, higher precision, and a faster turnaround time than SDS-PAGE and reversed-phase high-performance liquid chromatography (RP-HPLC).

Antibodies, Monoclonal↗

Nanomaterials and chip-based nanostructures for capillary electrophoretic separations of DNA.

Capillary electrophoresis (CE) and microchip capillary electrophoresis (MCE) using polymer solutions are two of the most powerful techniques for the analysis of DNA. Problems, such as the difficulty of filling polymer solution to small separation channels, recovering DNA, and narrow separation size ranges, have put a pressure on developing new techniques for DNA analysis. In this review, we deal with DNA separation using chip-based nanostructures and nanomaterials in CE and MCE. On the basis of the dependence of the mobility of DNA molecules on the size and shape of nanostructures, several unique chip-based devices have been developed for the separation of DNA, particularly for long DNA molecules. Unlike conventional CE and MCE methods, sieving matrices are not required when using nanostructures. Filling extremely low-viscosity nanomaterials in the presence and absence of polymer solutions to small separation channels is an alternative for the separations of DNA from several base pairs (bp) to tens kbp. The advantages and shortages of the use of nanostructured devices and nanomaterials for DNA separation are carefully addressed with respect to speed, resolution, reproducibility, costs, and operation.

DNA↗