Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “High Throughput Screening”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Imaging polarimetry for high throughput chiral screening.

Imaging polarimetry was demonstrated as a highly parallel method of determining optical rotation of biochemical samples. The imaging polarimeter utilized a bright, uniform light source wavelength-filtered to near the sodium D line, a sample array flanked by inlet and analyzing polarizers, and a CCD camera fitted with an equal-perspective telecentric lens. The prototype apparatus was demonstrated to have an optical resolution better than 0.08 degrees. The potential for high throughput screening was demonstrated by imaging chiral solutions in 1536-well microtiter plates and by real-time monitoring of 30 simultaneous chiral enzymatic reactions. Improvements in polarizer and CCD technology may broadly expand the technique's applicability to fields such as directed evolution and combinatorial chemistry, where screening throughput is currently limiting for chiral applications.

Algorithms↗

Capillary electrophoresis-based single strand DNA conformation analysis in high-throughput mutation screening.

The generation of the draft human genome sequence has created new possibilities for diagnosis, prevention, and treatment of human disease. One consequence of these new possibilities is an increasing need for methods and technology that can be used for high-throughput screening for mutations in large DNA sample materials. In recent years, a number of mutation screening methods have emerged that are based on the analysis of sequence-dependent changes in the conformation of single- and double-stranded DNA using capillary electrophoresis. Common features of these methods are high sensitivity and reproducibility as well as the possibility for automation and massive parallelization. Thus, at present they are among the most attractive technologies for high-throughput mutation screening. This review describes the recent advances in capillary electrophoresis-based single strand conformation polymorphism (CE-SSCP) for detection of unknown mutations, and assesses its practical usability for high-throughput mutation screening based on the available literature. In addition, future prospects are outlined in light of the recent advances in microchip-based capillary electrophoresis.

DNA Mutational Analysis↗

Development of a fluorescence polarization assay to screen for inhibitors of the FtsZ/ZipA interaction.

A fluorescence polarization competition assay has been developed to screen for inhibitors of the Escherichia coli FtsZ/ZipA protein-protein interaction. A previously published X-ray costructure demonstrated that a 17-amino-acid peptide, corresponding to FtsZ C-terminal residues 367-383 (FtsZ(367-383)), interacts with the C-terminal FtsZ binding domain of ZipA (ZipA(185-328)). Phage display was employed to identify a unique but related peptide which when further modified and labeled was shown to have a higher affinity to ZipA(185-328) than the FtsZ(367-383) peptide and binds to the same site. This peptide had a six fold increase in fluorescence polarization upon binding to ZipA(185-328) compared to a two fold increase for the FtsZ(367-383) fluorophore. As a result, assay parameters using the phage display peptide were further optimized and adapted for the high-throughput screen. A high-throughput screen of 250,000 compounds identified 29 hits with inhibition equal to or greater than 30% at 50 microg/ml. An X-ray costructure of a promising small molecule in this library complexed with ZipA(185-328) (KI=12 microM) revealed that the compound binds to the same hydrophobic pocket as the FtsZ(367-383) peptide.

Amino Acid Sequence↗

[Establishment of high-throughput drug screening model targeting retinoic acid receptor in cells].

AIM: To screen new drug for the treatment of acute promyelocytic leukemia, psoriasis and acne, high-throughput drug screening cell models marked by green fluorescent protein (GFP) have been established. METHODS: Eight repeats of retinoic acid response element (RARE) were synthesized and cloned into a GFP expression vector. This construct was stably transfected into cells in vitro. Stable and sensitive cell clones with high copy numbers of RARE were selected by retinoic acid (RA) using fluorescence-activated cell sorting (FACS). RESULTS: A cell line has been chosen to be high-throughput drug screening cell model. This model was shown with low background, high sensitive and good reproducibility, and was convenient and inexpensive. CONCLUSION: This drug screening cell model can be used for retinoic acid receptor target high-throughput drug screening.

Antineoplastic Agents↗

Recent developments in high-throughput mutation screening.

Screening of large sample materials for the presence of known or unknown mutations is a key element in pharmacogenomics. Although automated DNA sequencing has developed rapidly during the last decade, the technology is not well suited for projects involving analysis of hundreds of thousands of mutations. Consequently, a number of methods for high-throughput mutation screening have been developed. DNA microarrays and high-density oligonucleotide chips have proven to be well suited for parallel hybridisation-based analysis of hundreds or thousands of known mutations. Methods based on detection using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) have been developed. MALDI-TOF MS detection is limited to analysis of small DNA fragments but has a large potential for high-throughput single nucleotide polymorphism (SNP) analysis, due to a very fast analysis time and possibilities for automation. Currently, the best suited methods for high-throughput screening for unknown mutations are probably methods like single strand conformation polymorphism (SSCP) analysis or conformation sensitive gel electrophoresis (CSGE), combined with capillary array electrophoresis or denaturing high-performance liquid chromatography. This is due to a relatively short analysis time, potential for automation and a high sensitivity. The recent development of capillary array electrophoresis chips suggests that the analysis time for some of these methods may be reduced by one order of magnitude in the near future.

Chromatography, High Pressure Liquid↗

Surrogate docking: structure-based virtual screening at high throughput speed.

Structure-based screening using fully flexible docking is still too slow for large molecular libraries. High quality docking of a million molecule library can take days even on a cluster with hundreds of CPUs. This performance issue prohibits the use of fully flexible docking in the design of large combinatorial libraries. We have developed a fast structure-based screening method, which utilizes docking of a limited number of compounds to build a 2D QSAR model used to rapidly score the rest of the database. We compare here a model based on radial basis functions and a Bayesian categorization model. The number of compounds that need to be actually docked depends on the number of docking hits found. In our case studies reasonable quality models are built after docking of the number of molecules containing approximately 50 docking hits. The rest of the library is screened by the QSAR model. Optionally a fraction of the QSAR-prioritized library can be docked in order to find the true docking hits. The quality of the model only depends on the training set size - not on the size of the library to be screened. Therefore, for larger libraries the method yields higher gain in speed no change in performance. Prioritizing a large library with these models provides a significant enrichment with docking hits: it attains the values of approximately 13 and approximately 35 at the beginning of the score-sorted libraries in our two case studies: screening of the NCI collection and a combinatorial libraries on CDK2 kinase structure. With such enrichments, only a fraction of the database must actually be docked to find many of the true hits. The throughput of the method allows its use in screening of large compound collections and in the design of large combinatorial libraries. The strategy proposed has an important effect on efficiency but does not affect retrieval of actives, the latter being determined by the quality of the docking method itself.

Bayes Theorem↗

Toward high-throughput drug screening using mass spectrometry.

A critical overview on the potential of mass spectrometry-based methods regarding high-throughput screening analysis is presented. Within this scope, screening procedures will be discussed for simultaneous detection of several drug classes relevant to clinical and forensic toxicology or doping control in urine or blood using gas chromatography-mass spectrometry or liquid chromatography-mass spectrometry.

Drug Evaluation, Preclinical↗

Inkjet dispensing technology: applications in drug discovery.

The past year has seen significant advances in the reduction to practice of inkjet dispensing technology in drug discovery applications. Although much of the work in this area has been done by relatively few 'early innovators', broader acceptance of the feasibility of the use of inkjet dispensing is on the rise. Of the three main areas of drug discovery - genomics, high-throughput screening, and combinatorial chemistry - high-throughput screening has had the most applications to date. The burgeoning field of genomics has seen rapid incorporation of technologies that enable miniaturization of gene expression experiments. Inkjet dispensing has a clear role in this effort. Finally, as the miniaturization needs of combinatorial chemistry become more clear, inkjet dispensing technology will potentially play a role.

Biotechnology↗

Expression profiling of herpesvirus and vaccinia virus proteins using a high-throughput baculovirus screening system.

We have developed a high-throughput system for generating baculoviruses and testing the expression, solubility, and affinity column purification of encoded proteins. We have used this system to generate baculoviruses for and analyze the expression of 337 proteins from three different herpesviruses (HSV-1, EBV, and CMV) and vaccinia virus. Subsets of these proteins were also tested for expression and solubility in E. coli. Comparisons of the results in the two systems are presented for each virus.

Animals↗

Multiplexed screening of neutral mass-tagged RNA targets against ligand libraries with electrospray ionization FTICR MS: a paradigm for high-throughput affinity screening.

We demonstrate that binding of mixtures of aminoglycosides can be measured simultaneously against multiple RNA targets of identical length and similar (or identical) molecular weight. Addition of a neutral mass tag to one of the RNA targets shifts the detected peaks to a higher mass/charge ratio, where complexes with small molecules can be identified unambiguously. An appropriately placed neutral mass tag does not alter RNA--ligand binding. The utility of this strategy is demonstrated with model RNAs corresponding to the decoding region of the prokaryotic and eukaryotic rRNAs and a mixture of five aminoglycosides. Complexes are observed between the aminoglycoside library and the prokaryotic rRNA model, while no aminoglycoside was observed to bind to the mass-tagged eukaryotic rRNA model. The differential binding data is consistent with the eukaryotic A-site rRNA having a different conformation compared with the prokaryotic A-site that prevents entry and binding of neomycin-class aminoglycosides. Mass spectrometric analysis of neutral mass-tagged macromolecular targets represents a new high-throughput screening paradigm in which the interaction of multiple targets against a collection of small molecules can be evaluated in parallel.

Escherichia coli↗

Improving consistency of cell-based assays by using division-arrested cells.

In this article we describe the use of division-arrested cells for cell-based assays designed for high-throughput screening. Cells are the most critical and variable reagent for cell-based high-throughput screening. The robustness of robotic screening depends on the quality and consistency of cell reagents. We demonstrate that for most cell types commonly used for high-throughput screening, cells can be irreversibly division-arrested by mitomycin C treatment at doses that cause no apparent toxicity or obvious change to the cell signaling properties we measured. Our data also suggest that division-arrested cells perform favorably compared to regular growing cells in reporter and calcium flux assays, two platforms most commonly used in robotic screening. Division arrest technology effectively uncouples the process of cell production from robotic screening and brings the convenience of having quality-approved cell reagent on demand for cell-based high-throughput screening.

Animals↗

A general NMR method for rapid, efficient, and reliable biochemical screening.

High-throughput screening is usually the method of drug-lead discovery. It is now well accepted that, for a functional assay, quality is more important than quantity. The ligand-based or protein-based NMR screening methodologies for detecting compounds binding to the macromolecular target of interest are now well established. A novel and sensitive NMR method for rapid, efficient, and reliable biochemical screening is presented. The method named 3-FABS (three fluorine atoms for biochemical screening) requires the labeling of the substrate with a CF(3) moiety and utilizes (19)F NMR spectroscopy for the detection of the starting and enzymatically modified substrates. The method allows for high-quality screening of large compound or natural product extract collections and for measuring their IC(50) values. Applications of this technique to the screening of inhibitors of the Ser/Thr kinase AKT1 and the protease trypsin are presented. In addition, an interesting application of 3-FABS to functional genomics is also presented.

Enzyme Inhibitors↗

Discovery and evaluation of highly active imidotitanium ethylene polymerisation catalysts using high throughput catalyst screening.

A family of ca. 50 imidotitanium precatalysts [Ti(NR)(Me(3)[9]aneN(3))Cl(2)](R = alkyl or aryl; Me(3)[9]aneN(3)= 1,4,7-trimethyltriazacyclononane) were prepared in good yields using semi-automated procedures; high-throughput screening techniques identified seven highly active ethylene polymerisation precatalysts with activities in the range ca. 3 400 to 10 000 kg(PE) mol(-1) h(-1) bar(-1).

Journal Article↗

Expression and purification of catalytic domain of human macrophage elastase for high throughput inhibitor screening.

AIM: To obtain a catalytically active human macrophage elastase catalytic domain (hMECD) and to establish an efficient high-throughput method for screening macrophage elastase inhibitors. METHODS: Catalytic domain of human macrophage elastase was expressed in E coli and characterized to establish a high-throughput screening assay using a colorimetric method. A set of 8560 pure compounds and mixtures were screened. RESULTS: We have constructed an efficient E coli system for this human protein expression, and the recombinant hMECD protein was purified to homogeneity using anion-exchange chromatography after in vitro refolding from inclusion bodies. The yield of active hMECD protein was 23 mg from one liter of E coli culture after purification. Calcium and zinc ions were required both in refolding and enzymatic activity, but high concentration of zinc inhibited the refolding and activity. The hMECD cleaved several synthetic substrates including a chromogenic thiopeptolide and fluorogenic peptides with optimal activity around pH 8.0. Screening of 8560 compounds and mixtures led to identify 27 pure compounds and 14 natural products with inhibitory activity higher than 80 % at 20 mg/L. CONCLUSION: An efficient expression and purification method for hMECD protein has been established, and the assay is effective, reliable, and fast in identifying the recombinant protein inhibitors.

Amino Acid Sequence↗

Imaging systems in assay screening.

High-throughput screening laboratories continuously seek higher throughput, lower cost and compound conservation. In an attempt to approach these goals, improvements in traditional detection instruments (e.g. scintillation counters, fluorescence plate readers, luminometers) are being made. A more radical alternative is the use of image-based detection methods, which have the advantage that large numbers of wells can be quantified in a single detection procedure (favouring miniaturization) and that faint luminescence or scintillation assays can be accomplished very rapidly. However, image-based screening is a very new technology and must prove itself before being broadly accepted. In this review, the technology of a commercial instrument for image-based screening (the LEADseeker from Amersham Pharmacia Biotech, Amersham, UK) is described, and its performance summarized with scintillation, luminescence, fluorescence and absorbance signals.

Journal Article↗

ALARM NMR: a rapid and robust experimental method to detect reactive false positives in biochemical screens.

High-throughput screening (HTS) of large compound collections typically results in numerous small molecule hits that must be carefully evaluated to identify valid drug leads. Although several filtering mechanisms and other tools exist that can assist the chemist in this process, it is often the case that costly synthetic resources are expended in pursuing false positives. We report here a rapid and reliable NMR-based method for identifying reactive false positives including those that oxidize or alkylate a protein target. Importantly, the reactive species need not be the parent compound, as both reactive impurities and breakdown products can be detected. The assay is called ALARM NMR (a La assay to detect reactive molecules by nuclear magnetic resonance) and is based on monitoring DTT-dependent (13)C chemical shift changes of the human La antigen in the presence of a test compound or mixture. Extensive validation has been performed to demonstrate the reliability and utility of using ALARM NMR to assess thiol reactivity. This included comparing ALARM NMR to a glutathione-based fluorescence assay, as well as testing a collection of more than 3500 compounds containing HTS hits from 23 drug targets. The data show that current in silico filtering tools fail to identify more than half of the compounds that can act via reactive mechanisms. Significantly, we show how ALARM NMR data has been critical in identifying reactive compounds that would otherwise have been prioritized for lead optimization. In addition, a new filtering tool has been developed on the basis of the ALARM NMR data that can augment current in silico programs for identifying nuisance compounds and improving the process of hit triage.

Autoantigens↗

Algorithmic approach to high-throughput molecular screening for alpha interferon-resistant genotypes in hepatitis C patients.

This study was designed to analyze the feasibility and validity of using Cleavase Fragment Length Polymorphism (CFLP) analysis as an alternative to DNA sequencing for high-throughput screening of hepatitis C virus (HCV) genotypes in a high-volume molecular pathology laboratory setting. By using a 244-bp amplicon from the 5' untranslated region of the HCV genome, 61 clinical samples received for HCV reverse transcription-PCR (RT-PCR) were genotyped by this method. The genotype frequencies assigned by the CFLP method were 44.3% for type 1a, 26.2% for 1b, 13.1% for type 2b, and 5% type 3a. The results obtained by nucleotide sequence analysis provided 100% concordance with those obtained by CFLP analysis at the major genotype level, with resolvable differences as to subtype designations for five samples. CFLP analysis-derived HCV genotype frequencies also concurred with the national estimates (N. N. Zein et al., Ann. Intern. Med. 125:634-639, 1996). Reanalysis of 42 of these samples in parallel in a different research laboratory reproduced the CFLP fingerprints for 100% of the samples. Similarly, the major subtype designations for 19 samples subjected to different incubation temperature-time conditions were also 100% reproducible. Comparative cost analysis for genotyping of HCV by line probe assay, CFLP analysis, and automated DNA sequencing indicated that the average cost per amplicon was lowest for CFLP analysis, at $20 (direct costs). On the basis of these findings we propose that CFLP analysis is a robust, sensitive, specific, and an economical method for large-scale screening of HCV-infected patients for alpha interferon-resistant HCV genotypes. The paper describes an algorithm that uses as a reflex test the RT-PCR-based qualitative screening of samples for HCV detection and also addresses genotypes that are ambiguous.

Algorithms↗

Denaturing high performance liquid chromatography: high throughput mutation screening in familial hypertrophic cardiomyopathy and SNP genotyping in motor neurone disease.

AIMS: To evaluate the usefulness of denaturing high performance liquid chromatography (DHPLC) as a high throughput tool in: (1) DNA mutation detection in familial hypertrophic cardiomyopathy (FHC), and (2) single nucleotide polymorphism (SNP) discovery and validation in sporadic motor neurone disease (MND). METHODS: The coding sequence and intron-exon boundaries of the cardiac beta myosin heavy chain gene (MYH7) were screened by DHPLC for mutation identification in 150 unrelated patients diagnosed with FHC. One hundred and forty patients with sporadic MND were genotyped for the A67T SNP in the poliovirus receptor gene. All DHPLC positive signals were confirmed by conventional methods. RESULTS: Mutation screening of MYH7 covered 10 kb with a total of 5700 amplicons, and more than 6750 DHPLC injections were completed within 35 days. The causative mutation was identified in 14% of FHC cases, including seven novel missense mutations (L227V, E328G, K351E, V411I, M435T, E894G, and E927K). Genotyping of the A67T SNP was performed at two different temperatures both in MND cases and 280 controls. This coding SNP was found more frequently in MND cases (13.6%) than in controls (6.8%). Furthermore, 19 and two SNPs were identified in MYH7 and the poliovirus receptor gene, respectively, during DHPLC screening. CONCLUSIONS: DHPLC is a high throughput, sensitive, specific, and robust platform for the detection of DNA variants, such as disease causing mutations or SNPs. It enables rapid and accurate screening of large genomic regions.

Algorithms↗