Search PubMed⌕ Search

PubMed · 11722288

Recent developments in high-throughput mutation screening.

Abstract

Screening of large sample materials for the presence of known or unknown mutations is a key element in pharmacogenomics. Although automated DNA sequencing has developed rapidly during the last decade, the technology is not well suited for projects involving analysis of hundreds of thousands of mutations. Consequently, a number of methods for high-throughput mutation screening have been developed. DNA microarrays and high-density oligonucleotide chips have proven to be well suited for parallel hybridisation-based analysis of hundreds or thousands of known mutations. Methods based on detection using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) have been developed. MALDI-TOF MS detection is limited to analysis of small DNA fragments but has a large potential for high-throughput single nucleotide polymorphism (SNP) analysis, due to a very fast analysis time and possibilities for automation. Currently, the best suited methods for high-throughput screening for unknown mutations are probably methods like single strand conformation polymorphism (SSCP) analysis or conformation sensitive gel electrophoresis (CSGE), combined with capillary array electrophoresis or denaturing high-performance liquid chromatography. This is due to a relatively short analysis time, potential for automation and a high sensitivity. The recent development of capillary array electrophoresis chips suggests that the analysis time for some of these methods may be reduced by one order of magnitude in the near future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L A Larsen, M Christiansen, J Vuust, P S Andersen. 2001. Recent developments in high-throughput mutation screening.. https://doi.org/10.1517/14622416.2.4.387

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantitative determination of trimebutine maleate and its three metabolites in human plasma by liquid chromatography-tandem mass spectrometry.

A sensitive and selective HPLC-MS-MS method was developed for the determination of trimebutine maleate (TM) and its major metabolites N-monodemethyltrimebutine (TM-MPB), N-didemethyltrimebutine (APB) and 3,4,5-trimethoxybenzoic acid (TMBA) in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction and chromatographed on a YMC J'sphere C(18) column. The mobile phase consisted of 2 mM ammonium acetate buffer (pH 6.5)-methanol (20:80, v/v), and at a flow-rate of 0.2 ml/min. Detection was carried out on a triple quadrupole tandem mass spectrometer in multiple reactions monitoring (MRM) mode using positive-negative switching electrospray ionization (ESI). The method was validated over the concentration range of 1-100 ng/ml for trimebutine maleate and APB, 1-500 ng/ml for MPB, and 50-10,000 ng/ml for TMBA. Inter- and intra-day precision (RSD%) for trimebutine maleate and its three metabolites were all within +/-15% and the accuracy was within 85-115%. The limit of quantitation was 1 ng/ml for trimebutine maleate, TM-MPB and APB, and 50 ng/ml for TMBA. The extraction recovery was on average 58.2% for trimebutine maleate, 69.6% for MPB, 51.2% for APB and 62.5% for TMBA. The method was applied to the pharmacokinetic study of trimebutine maleate and its metabolites in healthy Chinese volunteers.

Chromatography, High Pressure Liquid↗

Monolithic silica liquid chromatography columns for the determination of cyclooxygenase II inhibitors in human plasma.

Methods employing monolithic HPLC columns for the determination of the cyclooxygenase II inhibitors rofecoxib (I) and 3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one (DFP, III) in human plasma are described. Each analyte, together with an internal standard was extracted from the plasma matrix using solid-phase extraction in the 96-well format. The analytes were chromatographed on a Chromolith Speed Rod monolithic HPLC column (4.6 x 50 mm). Analyte detection for rofecoxib was via fluorescence following post-column photochemical derivatization. Detection for III was based on the native fluorescence of the compound. The precision, accuracy, and linearity of the methods were found to be comparable to those obtained using methods employing conventional packed HPLC columns. Use of the monolithic column permitted mobile phase flow-rates of up to 6.5 ml/min to be employed in the assays. The use of elevated flow-rates enabled the per sample analysis time to be reduced by up to a factor of 5 compared with assays based on packed HPLC columns. The results of experiments aimed at evaluating the ruggedness and reproducibility of monolithic columns employed in bioanalytical methods are presented.

Chromatography, High Pressure Liquid↗

Postharvest stilbene-enrichment of red and white table grape varieties using UV-C irradiation pulses.

The red table grape varieties Flame, Red Globe, Crimson, and Napoleon, as well as the white varieties Superior, Dominga, and Moscatel Italica, were irradiated with a previously optimized UV-C postharvest irradiation protocol (510 W, 40 cm, 60 s). The induction kinetics of the stilbenes trans-resveratrol, trans-piceid, trans-piceatannol, trans-astringin, and viniferins was followed by using HPLC-DAD/MS/MS. The most inducible stilbenes were trans-resveratrol, trans-piceatannol, and viniferins. Both quantitative and qualitative differences were observed in both the stilbene induction kinetics and stilbene content in the seven table grapes analyzed here. The total resveratrol content ranged from 0.69 mg/100 g fw (Dominga) to 2.3 mg/100 g fw (Red Globe). The net resveratrol induction ranged from 3.4-fold (Flame) to 2315-fold (Red Globe). The highest viniferins content was observed in the variety Flame (0.73 mg/100 g fw), although the variety Red Globe presented the highest viniferins induction (175-fold). The highest content and induction of piceatannol (0.17 mg/100 g fw and 173-fold, respectively) was observed in the variety Flame. It should be stressed that taking into account the health-beneficial effects claimed for stilbenes, the UV-C irradiated table grapes can be considered as new functional fruits that can supply (a serving of unpeeled 200 g table grapes) the resveratrol content (depending on the variety) equivalent to more than seven glasses of red wine ( approximately 1.5 L) with high resveratrol content.

Chromatography, High Pressure Liquid↗