Search PubMedSearch

SEARCH · Search PubMed

Results for “artificial insemination by husband”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,765 records · Page 4Linked to original sources

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3 mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40 mL, 2-3 mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0 mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

Suppression of AAV-Delivered Transgene Expression Using Artificial MicroRNAs Delivered by an Alternative AAV Serotype.

Adeno-associated virus (AAV) gene transfer vectors mediate long-term expression in nondividing cells, an advantage for treating chronic disorders. However, current platforms lack a way to selectively shut down transgene expression if adverse effects arise. To create an "off switch," we hypothesized that incorporating unique artificial microRNA (amiRNA) target sequences into an AAV expression cassette would allow subsequent suppression of transgene expression using a second AAV vector encoding the cognate amiRNA. We introduced 22-nt sequences absent from human and mouse transcriptomes into the 3' untranslated region (UTR) of a therapeutic AAV cassette. To identify optimal amiRNAs, two tandem copies of each amiRNA were cloned into the 3'UTR of an mCherry reporter gene. In vitro assessment of six amiRNA/target pairs using a dual luciferase assay identified four amiRNAs that efficiently suppressed reporter expression. Cells cotransfected with target site 3 (TS3) and amiRNA-T3B showed the greatest reduction in luciferase activity (80%, p < 0.0001) and were selected for further study. The "off-switch" system was then evaluated using an AAV5 therapeutic vector expressing a recombinant humanized anti-IgE monoclonal antibody (AAV5-TBG-anti-IgE-TS3), designed for long-term suppression of allergen-induced reactions. Co-transfection of HEK293T cells with anti-IgE-TS3 and amiRNA-T3B significantly reduced anti-IgE mRNA and protein levels relative to a control amiRNA (p < 0.0001). In vivo testing in Balb/c mice (n = 5) involved intravenous administration of AAV5-anti-IgE-TS3 (3.2 &#xd7; 1010 gc), followed 4 weeks later by an AAVrh.10 amiRNA vector (AAVrh.10-TBG-amiRNA-T3B; 1 &#xd7; 1011 gc). Control mice receiving only the therapeutic vector expressed 18.4 &#xb1; 13.8 &#xb5;g/mL serum anti-IgE at 10 weeks. In contrast, mice receiving the amiRNA "off" vector showed marked suppression of anti-IgE (0.3 &#xb1; 0.15 &#xb5;g/mL, p < 0.0001). These findings provide proof-of-concept that AAV-delivered amiRNAs can selectively switch off transgene expression, offering a strategy to improve the safety of AAV-mediated gene therapies.

Dependovirus

Beyond predictive performance: A systematic review and critical methodological appraisal of AI/ML and conventional modelling strategies in breast, colorectal, and pancreatic Cancer.

BACKGROUND: Predictive modelling for cancer risk, treatment-related complications, and survival is central to precision oncology. Conventional logistic regression (LR) and Cox proportional hazards (CoxPH) regression remain widely used but are limited when modelling nonlinear interactions, high-dimensional imaging features, and multimodal clinical-metabolic predictors. Artificial intelligence (AI) and machine learning (ML) methods offer expanded capability through automated feature extraction, ensemble learning, and flexible survival modelling, but the evidence on when AI/ML adds value over conventional models across cancer sites and predictive tasks remains fragmented. OBJECTIVE: To systematically evaluate the methodological performance, validation strategies, and translational limitations of AI/ML models compared with conventional statistical models in published predictive-modelling studies for breast, colorectal, or pancreatic cancer. METHODS: PubMed, Scopus, and Web of Science were searched for studies published between January 2019 and March 2025. Two reviewers independently conducted title-and-abstract screening, full-text eligibility assessment, and PROBAST risk-of-bias assessment. Sixty-five studies (n&#xa0;=&#xa0;907,567 participants) were narratively synthesised by cancer site, predictive task, model family, comparator, validation strategy, predictor modality, and calibration or explainability reporting. RESULTS: The 65 studies comprised breast cancer (n&#xa0;=&#xa0;35), colorectal cancer (n&#xa0;=&#xa0;21), and pancreatic cancer (n&#xa0;=&#xa0;9). AI/ML superiority over LR and CoxPH was task- and data-dependent. CNN- and U-Net-based models predominated in imaging and body-composition tasks, tree-based ensembles consistently outperformed LR for tabular perioperative complication prediction, and CoxPH remained competitive, and in the largest pancreatic risk study, superior to XGBoost (C-index 0.802 vs 0.723) in well-structured datasets. PROBAST analysis-domain risk was moderate in 54 of 65 studies (83%), driven by limited external validation, sparse calibration reporting (11/65), and few decision-curve analyses (7/65). CONCLUSION: AI/ML adds the most methodological value in imaging-derived feature extraction and nonlinear perioperative prediction, while conventional regression remains preferable in large, structured datasets with linear predictors. Clinical translation requires standardised body-composition definitions, external validation, calibration assessment, decision-curve analysis, and explainability, in line with TRIPOD+AI and CLAIM standards.

Humans

Evaluation of a cornea-specialized large language model for diagnostic and management accuracy in complex corneal cases.

PURPOSE: To evaluate whether a cornea-specialized large language model (LLM) enhanced with retrieval-augmented generation (RAG) improves clinicians' diagnostic and management accuracy in complex corneal cases compared to a general-purpose GPT-4o model and unaided clinician performance. METHODS: This prospective, randomized, masked evaluation study involved three cornea trainees who each independently reviewed 39 real-world corneal cases under three experimental conditions: unaided, GPT-4o-assisted, and assisted by a cornea-specialized GPT-4o model. The cornea-specialized model was constructed by embedding over 200 publicly available Wikipedia articles into GPT-4o's RAG framework. Participants provided open-ended diagnoses and selected the next-step management options (multiple choice). They were allowed up to three GPT-4o queries per case, and the AI-assisted arms were randomized to minimize bias. Accuracy for both tasks was compared against expert reference standards using McNemar's test. RESULTS: Diagnostic accuracy was 48.7%, 20.5%, and 38.5% unaided, improving to 69.2%, 46.2%, and 59.0% with general GPT-4o (p<0.04). The cornea-specialized GPT-4o further improved accuracy to 71.8%, 48.7%, and 74.4%, with improvements over unaided performance for all clinicians (p<0.01). For next-step decisions, unaided accuracy was 76.9%, 87.2%, and 59.0%. With the specialized model, Ophthalmologist 3 improved to 71.8% (p<0.05), Ophthalmologist 1 remained high at 82.1%, and Ophthalmologist 2 declined to 64.1% (p<0.05). CONCLUSIONS: A cornea-specialized LLM enhanced with RAG improved diagnostic accuracy in complex corneal cases, particularly among clinicians with lower baseline performance. Effects on management accuracy were inconsistent. Future studies should explore the use of open-ended management tasks and examine whether smaller, curated retrieval corpora yield better model performance.

Humans

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30&#xb7;9% (114 of 369 patients) with HD-WL versus 33&#xb7;8% (123 of 364 patients) with CADe assistance (odds ratio 1&#xb7;14 [95% CI 0&#xb7;83-1&#xb7;57], p=0&#xb7;41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85&#xb7;9% (95% CI 82&#xb7;0-89&#xb7;1) and specificity was 91&#xb7;4% (89&#xb7;4-93&#xb7;0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans

User Engagement and Feature Preferences in an AI-Powered mHealth Intervention for Diabetes Prevention: Secondary Analysis of a Randomized Controlled Trial.

BACKGROUND: Prediabetes is highly prevalent and increasing globally, yet lifestyle interventions remain underused. AI-driven mobile health (mHealth) tools can help scale diabetes prevention efforts, but the key factors driving their success are not well understood. OBJECTIVE: This post hoc secondary analysis of a randomized controlled trial (RCT) aimed to characterize the most valued features and the role of user engagement in outcomes of a fully automated mHealth intervention for diabetes prevention. METHODS: Data from 151 participants with prediabetes and overweight or obesity who were assigned to an AI-based diabetes prevention program (Sweetch) in a parent RCT (NCT05056376) were analyzed. Engagement (defined as the total number of days the app was used) was categorized into tertiles (low, medium, and high). Baseline characteristics were compared across engagement groups using ANOVA, Kruskal-Wallis, and chi-square tests, and regression models assessed the association between engagement and achievement of diabetes risk reduction outcomes (&#x2265;5% weight loss, &#x2265;4% weight loss with &#x2265;150 min/week of physical activity, or &#x2265;0.2 percentage point reduction in hemoglobin A1c [HbA1c] at 12 months). Perceived usefulness of intervention features was surveyed at 12 months. RESULTS: Median engagement was 98 (IQR 34-232) days. Older age (P<.001) and lower baseline BMI (P=.04) were significantly associated with higher engagement. Compared with low engagement, high engagement was associated with greater odds of achieving the composite diabetes risk reduction outcome (odds ratio [OR] 2.59, 95% CI 1.11-6.01; P=.03), &#x2265;5% weight loss (OR 3.31, 95% CI 1.16-9.42; P=.03), and &#x2265;0.2 percentage point reduction in HbA1c (OR 3.57, 95% CI 1.19-10.75; P=.02). Participants most frequently rated weight tracking, physical activity tracking, and the digital body weight scale as the features that were most helpful for achieving their health goals. CONCLUSIONS: Higher engagement with an AI-driven intervention requiring no human intervention was associated with improved diabetes risk reduction. Contrary to concerns about lower digital literacy, older adults engaged with the intervention more than younger adults. Features related to weight and physical activity tracking were most valued by patients in the program. TRIAL REGISTRATION: ClinicalTrials.gov NCT05056376; https://clinicaltrials.gov/study/NCT05056376.

Humans

From fear to empowerment: the&#xa0;impact of employees AI awareness on workplace well-being - a new insight from the JD-R model.

PURPOSE: The primary purpose of the study was to explore the impact of health workers' awareness of artificial intelligence (AI) on their workplace well-being, addressing a critical gap in the literature. By examining this relationship through the lens of the Job demands-resources (JD-R) model, the study aimed to provide insights into how health workers' perceptions of AI integration in their jobs and careers could influence their informal learning behaviour and, consequently, their overall well-being in the workplace. The study's findings could inform strategies for supporting healthcare workers during technological transformations. DESIGN/METHODOLOGY/APPROACH: The study employed a quantitative research design using a survey methodology to collect data from 420 health workers across 10 hospitals in Ghana that have adopted AI technologies. The study was analysed using OLS and structural equation modelling. FINDINGS: The study findings revealed that health workers' AI awareness positively impacts their informal learning behaviour at the workplace. Again, informal learning behaviour positively impacts health workers' workplace well-being. Moreover, informal learning behaviour mediates the relationship between health workers' AI awareness and workplace wellbeing. Furthermore, employee learning orientation was found to strengthen the effect of AI awareness on informal learning behaviour. RESEARCH LIMITATIONS/IMPLICATIONS: While the study provides valuable insights, it is important to acknowledge its limitations. The study was conducted in a specific context (Ghanaian hospitals adopting AI), which may limit the generalizability of the findings to other healthcare settings or industries. Self-reported data from the questionnaires may be subject to response biases, and the study did not account for potential confounding factors that could influence the relationships between the variables. PRACTICAL IMPLICATIONS: The study offers practical implications for healthcare organizations navigating the digital transformation era. By understanding the positive impact of health workers' AI awareness on their informal learning behaviour and well-being, organizations can prioritize initiatives that foster a learning-oriented culture and provide opportunities for informal learning. This could include implementing mentorship programs, encouraging knowledge-sharing among employees and offering training and development resources to help workers adapt to AI-driven changes. Additionally, the findings highlight the importance of promoting employee learning orientation, which can enhance the effectiveness of such initiatives. ORIGINALITY/VALUE: The study contributes to the existing literature by addressing a relatively unexplored area - the impact of AI awareness on healthcare workers' well-being. While previous research has focused on the potential job displacement effects of AI, this study takes a unique perspective by examining how health workers' perceptions of AI integration can shape their informal learning behaviour and, subsequently, their workplace well-being. By drawing on the JD-R model and incorporating employee learning orientation as a moderator, the study offers a novel theoretical framework for understanding the implications of AI adoption in healthcare organizations.

Humans

Plant cis-regulatory grammar: Decoding the multidimensional code of transcriptional regulation for programmable crop engineering.

Cis-regulatory elements (CREs) orchestrate the spatiotemporal precision of gene expression that underlies plant development, adaptation, and domestication. Decoding the cis-regulatory grammar of plant genomes remains a central challenge in modern biology, with profound implications for programmable crop engineering. Here, recent conceptual and technological advances are synthesized to reshape our understanding of plant CREs. This review first argues that CRE function is not only an intrinsic property of DNA sequence alone but also emerges from a multidimensional context, including chromatin accessibility, histone modifications, three-dimensional genome topology, and cell type-specific regulatory landscapes. Furthermore, the convergence of single-cell epigenomics, high-throughput functional assays, and CRISPR-based dissection has begun to unravel this contextual grammar, revealing the computational principles governing transcriptional regulation. Critically, we propose that artificial intelligence (AI) platforms are catalyzing an ongoing transition from descriptive discovery to predictive engineering, wherein these platforms outperform natural evolution in designing synthetic CREs. Finally, a roadmap is outlined toward a plant regulatory grammar foundation model, which will enable truly predictive engineering of gene expression when fine-tuned for specific tasks. Collectively, the integration of single-cell resolution maps, precise genome editing, AI-driven design, and regulatory-compliant delivery systems promises to transform our ability to reprogram plant gene regulation for next-generation agriculture, bridging the gap between foundational regulatory biology and tangible crop improvement.

artificial intelligence

Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis.

BACKGROUND: Colorectal cancer remains a leading cause of death despite being largely preventable through polypectomy. AI systems designed to enhance polyp detection during colonoscopy have shown promise, but the extent to which they improve detection of different-sized polyps remains unclear. OBJECTIVE: This study compared the size-stratified efficacy of AI-assisted colonoscopy vs standard colonoscopy using the Hartung-Knapp-Sidik-Jonkman (HKSJ) method, and generated exploratory rankings while acknowledging all cross-platform comparisons are indirect. METHODS: This systematic review and network meta-analysis (NMA) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception to July 25, 2026, supplemented by citation searching. We included randomized controlled trials (RCTs) comparing AI-assisted vs standard colonoscopy in adults (&#x2265;18 years of age), reporting mean polyp detection counts stratified by size (&#x2264;5 mm, 6-9 mm, and &#x2265;10 mm). Two reviewers screened studies, extracted data, and assessed risk of bias using the Cochrane Risk of Bias 2.0. We conducted frequentist NMA using the HKSJ method with restricted maximum likelihood estimation, calculated 95% prediction intervals (PIs), and assessed heterogeneity using I2 and &#x3c4;2. Certainty of evidence was rated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) framework. RESULTS: A total of 13 RCTs (4156 participants) compared 8 AI systems to standard colonoscopy, forming a network without direct AI comparisons. For diminutive polyps (&#x2264;5 mm), AI showed a modest advantage (standardized mean difference [SMD] 0.21, 95% CI 0.07 to 0.35, 95% PI -1.12 to 1.54), but substantial heterogeneity (I2=86.6%) and wide PI crossing the null indicated high uncertainty. EndoScreener showed the most consistent evidence (SMD 0.36, 95% CI 0.18-0.54). For small and large polyps, effects were minimal (SMD 0.02, 95% CI -0.02 to 0.06, 95% PI -0.03 to 0.07; SMD 0.01, 95% CI 0.00-0.02, 95% PI -0.01 to 0.03). GRADE certainty was very low for diminutive polyps and low for small and large polyps. Sensitivity analysis excluding Tianjin YuJin did not materially change findings. CONCLUSIONS: AI may modestly enhance diminutive polyp detection, but effects on small and large polyps are minimal, with no platform superiority. Given very low to low certainty, findings are hypothesis-generating. This exploratory NMA provides size-stratified comparisons that can inform future head-to-head trial design. Unlike prior reviews aggregating all polyp sizes, we show the overall AI benefit is driven by diminutive polyp detection, providing a framework for targeted deployment-prioritizing AI for diminutive polyp screening, with limited value for larger lesions. Head-to-head trials are urgently needed. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD420251266932; https://www.crd.york.ac.uk/PROSPERO/view/CRD420251266932.

Colonoscopy

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Systematic evaluation of one-dimensional-to-two-dimensional near-infrared spectroscopy transformations with deep learning for quantifying coconut sap adulteration.

Near-infrared (NIR) spectroscopy have limitations when combined with deep learning (DL) algorithms because they rely on low-dimensional datasets. Therefore, we investigated the potential of transforming one-dimensional (1D) NIR spectra into two-dimensional (2D) spectrograms using synchronous and asynchronous techniques and the continuous wavelet transform (CWT) and their effectiveness by integrating with DL for detecting adulteration in coconut sap. NIR spectra (12,500-4000&#xa0;cm-1) were collected from binary mixtures (0%-100%;w/w). The performance of all DL (convolutional neural networks-CNN, AlexNet and ResNet) models was compared with that of partial least squares (PLS). The models were ranked in the mentioned order based on their performances: 2D-CWT&#xa0;>&#xa0;2D-asynchronous > 2D-synchronous > 1D/2D-PLS. The important features of the best model can be explained and visualized using gradient-weighted-class-activation-mapping. The findings highlight that the 1D-to-2D NIR data transformation combined with DL is a highly robust approach because it addresses the feature representation gap in NIR data and effectively captures the spatial-spectral correlations.

Spectroscopy, Near-Infrared

ORBIT: Oncogenic Representation Learning via Bi-Prototype Contrastive Learning in Hyperbolic Space for cancer driver gene identification.

Accurate identification of cancer driver genes is crucial for precision oncology but remains challenging due to the complexity of integrating heterogeneous data and modeling dynamic biological systems. To address these limitations, we propose ORBIT (Oncogenic Representation Learning via Bi-Prototype Contrastive Learning in Hyperbolic Space). Our framework synergistically fuses multi-omics profiles with functional network data using a context-adaptive graph reweighting mechanism to capture cancer-specific dynamics. The model employs a bi-prototype contrastive learning strategy within hyperbolic space, which aligns gene representations around distinct driver and non-driver semantic anchors while preserving the intrinsic hierarchy of biological networks. Comprehensive evaluations demonstrate that ORBIT achieves highly competitive stability in pan-cancer analysis while consistently outperforming state-of-the-art methods in cancer-specific predictions. Furthermore, functional enrichment analysis confirms that the model effectively segregates core cancer pathways, and drug sensitivity profiling validates the clinical relevance of the identified drivers. By integrating hyperbolic geometry with context-adaptive learning, ORBIT offers a robust and interpretable paradigm for precision medicine. The source codes and datasets are publicly accessible at https://github.com/spcho-dev/ORBIT.

Humans

Assessment of atypical glandular cell interpretation in Pap tests using the Hologic Genius Digital Diagnostics System.

Atypical glandular cells (AGC) are a diagnostic challenge. The aim of this study was to evaluate the efficacy and diagnostic performance of AGC detection on the Hologic Genius Digital Diagnostics System (HGDDS). A retrospective analysis of 451 ThinPrep Pap cases was conducted, including 207 cases of AGC, 27 cases of high-grade squamous intraepithelial lesion (HSIL), 25 cases of low-grade squamous intraepithelial lesion (LSIL), and 192 benign cases. All AGC cases had follow-up histologic diagnoses, with 66 cases subsequently diagnosed as adenocarcinoma. The slides were randomized, scanned, and analyzed by the HGDDS. Patient age and HPV test results were provided to reviewers, an experienced cytologist, who screened the cases, followed by two cytopathologists who independently examined the cases on the HGDDS. Diagnostic concordance between the two cytopathologists indicated strong agreement (&#x3ba; = 0.829). Sensitivity of AGC on Papanicolaou (Pap) tests for adenocarcinoma detection on HGDDS was 98.5% and 95.5%, respectively, comparable to the original ThinPrep interpretation (OTPI). Specificity for adenocarcinoma detection was significantly higher (84.6% and 85.6%) with the HGDDS than 27.7% with OTPI. Overall, the diagnostic performance for AGC/HSIL interpretation to detect CIN2/3/adenocarcinoma appeared to have improved with HGDDS compared with OTPI, particularly for specificity and positive predictive value (PPV). This is the first study evaluating AGC diagnosis using the HGDDS. The findings demonstrate that the sensitivity of adenocarcinoma detection as AGC on HGDDS is comparable to the ThinPrep Imaging System, but the specificity and PPV are improved. This suggests the potential of artificial intelligence to augment the performance of cervical cancer screening.

Humans

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans

Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis.

BACKGROUND: Obstructive sleep apnea (OSA) is highly prevalent but remains substantially underdiagnosed. Polysomnography (PSG) is the reference standard, but its cost and limited availability constrain large-scale case identification. AI-based screening tools may support risk stratification and referral prioritization, but their diagnostic accuracy across apnea-hypopnea index (AHI) thresholds remains uncertain. OBJECTIVE: This review aimed to systematically evaluate the diagnostic accuracy of AI-based OSA screening tools at AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, with emphasis on models using non-PSG-derived inputs. METHODS: PubMed, Embase, Scopus, and Web of Science were searched for studies published from January 1, 2016, to May 3, 2026. Eligible studies included adults evaluated for suspected OSA or recruited from population-based cohorts, assessed AI-based models intended or interpretable for OSA screening, risk prediction, or screening-oriented severity classification, used PSG as the reference standard, and reported sufficient data to construct or reconstruct 2&#xd7;2 contingency tables. Diagnostic accuracy was synthesized separately by AHI threshold and input source using bivariate random-effects models, with 95% CIs and prediction intervals (PIs). Risk of bias and certainty of evidence were assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) and GRADE (Grading of Recommendations Assessment, Development, and Evaluation), respectively. RESULTS: A total of 60 studies were included, of which 47 contributed data to the meta-analysis. At AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, pooled sensitivities were 0.94 (95% CI 0.92-0.96; 95% PI 0.71-0.99), 0.87 (95% CI 0.84-0.89; 95% PI 0.66-0.96), and 0.83 (95% CI 0.79-0.87; 95% PI 0.61-0.94), respectively; the corresponding specificities were 0.77 (95% CI 0.69-0.84; 95% PI 0.30-0.96), 0.81 (95% CI 0.75-0.85; 95% PI 0.39-0.96), and 0.91 (95% CI 0.87-0.94; 95% PI 0.55-0.99), respectively. The corresponding areas under the summary receiver operating characteristic curves were 0.943, 0.907, and 0.920. For non-PSG-derived tools, sensitivities were 0.92, 0.85, and 0.81, and specificities were 0.70, 0.74, and 0.85 at the 3 thresholds, respectively. For PSG-derived models, sensitivities were 0.96, 0.90, and 0.85, and specificities were 0.82, 0.88, and 0.96, respectively. Exploratory subgroup analyses suggested performance variation across selected study and model characteristics, including region, algorithmic framework, data source, and validation method. CONCLUSIONS: AI-based tools showed generally favorable screening performance for OSA across clinically relevant AHI thresholds, although wide PIs suggest variable performance across future comparable populations and settings. By synthesizing diagnostic accuracy across 3 AHI thresholds and distinguishing non-PSG-derived from PSG-derived models, this review extends previous broad or modality-specific reviews and offers a clinically interpretable, pathway-specific basis for linking model performance to intended use. The findings may clarify potential roles for non-PSG-derived tools in front-end screening and referral prioritization and for PSG-derived models in reduced-channel assessment and sleep-laboratory workflow support. Given substantial heterogeneity, limited external validation, and low or very low certainty of evidence, prospective validation is needed before routine implementation.

Humans

Socket motility assessment of anophthalmic sockets: a systematic review.

PURPOSE: Systematically review and categorize the methods used to assess socket and prosthetic motility in anophthalmic patients following enucleation or evisceration. METHODS: A systematic review was conducted in accordance with PRISMA guidelines. PubMed, Embase, Web of Science, and Scopus were searched from inception through September 2024. Studies reporting qualitative or quantitative assessments of motility in anophthalmic sockets or ocular prostheses were included. Motility assessment methods were categorized as qualitative (descriptive or graded clinical evaluation) or quantitative (numerical measurements in millimeters, degrees, or objective tracking systems). RESULTS: Thirty-five studies encompassing 1,819 patients met inclusion criteria. Nineteen studies used qualitative assessment methods, including subjective observation, graded scales based on cardinal gaze positions, or comparison with the contralateral eye. Sixteen studies employed quantitative techniques, such as the Kestenbaum limbus test, Lister perimeter measurements, conjunctival or limbal markings, photographic image analysis, infrared eye-tracking systems, and magnetic search-coil technology. Considerable heterogeneity was observed in measurement techniques, reporting standards, timing of assessment, and distinction between socket and prosthetic motility. CONCLUSIONS: Substantial variability exists in the methods used to assess motility in anophthalmic sockets, limiting comparability across studies. Establishing standardized, feasible, and reproducible assessment approaches may improve outcome reporting and facilitate meaningful comparisons in future oculoplastic research.

Humans

Community-driven advances in computational mass spectrometry: The perspective of EuBIC-MS members.

Advances in data acquisition, artificial intelligence, and integrative bioinformatics are driving the rapid evolution of computational mass spectrometry, and in turn, transforming modern proteomics, metabolomics, and lipidomics. These developments have greatly increased the scale and complexity of mass spectrometry data, underscoring the importance of evolving accurate, transparent, efficient and reproducible data processing workflows. Addressing these challenges requires collaborative innovation that brings together expertise in software engineering, statistics, and biology. The European Bioinformatics Community for Mass Spectrometry (EuBIC-MS), an initiative of the European Proteomics Association (EuPA), fosters a culture of open, community-driven development through its biennial Developers Meetings and Winter Schools. This commentary summarizes the scientific background and outcomes of the EuBIC-MS Developers Meeting 2025, which took place in Novacella, Italy. Three keynote presentations highlighted major frontiers in the field: deep proteome and phosphoproteome profiling, text mining for protein-protein interaction extraction, and scalable proteomics for AI-driven drug discovery. Seven community-selected hackathons addressed emerging challenges such as single-cell proteomics data analysis, FAIR metadata extraction, deep learning frameworks, R-Python interoperability, and DIA validation. Together, these efforts demonstrate the potential for scientific and technical innovation to arise from open collaboration, and highlight how community-driven initiatives can accelerate progress in computational mass spectrometry. SIGNIFICANCE: Modern proteomics increasingly depends on computational advances to translate complex, high-dimensional data into biological knowledge. The EuBIC-MS Developers Meeting 2025 exemplifies how community-driven collaboration can directly accelerate this process by bringing together experts from bioinformatics, statistics, and experimental proteomics to co-develop open, interoperable, and reproducible analytical tools. By fostering shared software frameworks, transparent benchmarking, and collaborative problem solving, the EuBIC-MS community helps ensure that technological innovation translates into reliable biological insights. This collaborative model strengthens the foundation for quantitative, system-level understanding of proteomes and establishes a sustainable path for integrating artificial intelligence and next-generation data acquisition into routine biological discovery. This commentary shows some current highlights in the field of computational mass spectrometry and community-based approaches undertaken during the most recent Developers Meeting to solve these challenges. The approaches discussed and initiated during the meeting - ranging from deep proteome profiling and phosphosite mapping to text mining, single-cell data analysis, and FAIR metadata extraction - address key bottlenecks that currently limit the biological interpretability and comparability of proteomics data.

Mass Spectrometry

Closed-loop insulin delivery for glycaemic control in hospitalised and perioperative adults: A systematic review and meta-analysis of randomised controlled trials.

We evaluated whether closed-loop insulin delivery improves glycaemic control in hospitalised and perioperative adults. PubMed/MEDLINE, Embase, CENTRAL, and ClinicalTrials.gov were searched from inception to 29 June 2026 for randomised controlled trials comparing closed-loop or automated insulin delivery with usual care or conventional insulin therapy. Random-effects meta-analyses were conducted; risk of bias was assessed using RoB 2 and certainty of evidence using GRADE. Seven trials involving 375 analysed participants were included. Closed-loop insulin delivery increased time in target glucose range by 23.91 percentage points (95% CI 19.40 to 28.43; I2&#xa0;=&#xa0;0%) and reduced mean glucose by 1.79&#xa0;mmol/L (95% CI 1.06 to 2.53 lower; I2&#xa0;=&#xa0;36.3%); certainty was moderate for both outcomes. Two trials involving 69 participants reported compatible participant-level data for clinically significant hyperglycaemia, and both estimates favoured closed-loop insulin delivery, although the evidence was exploratory and imprecise. No severe hypoglycaemic events occurred in either group, precluding reliable estimation of comparative safety. Closed-loop insulin delivery may improve glycaemic process measures, but larger pragmatic trials are needed to establish clinical benefits, safety, and implementation feasibility.

Humans