Search PubMedSearch

SEARCH · Search PubMed

Results for “Gene editing technology”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

395 records · Page 4Linked to original sources

Mitigating pH-induced instability in deruxtecan-based ADCs: an onboard-mixing icIEF approach for robust charge heterogeneity characterization.

Accurate charge variant analysis of antibody-drug conjugates (ADCs) is essential for understanding product heterogeneity and ensuring quality control. However, Deruxtecan (DXd)-based ADCs present a unique analytical challenge due to the intrinsic instability of the payload, where the lactone ring readily undergoes hydrolysis under alkaline conditions, resulting in time-dependent shifts in charge distribution during imaged capillary isoelectric focusing (icIEF). In this study, we describe the development of an onboard-mixing icIEF method designed to minimize pH-induced degradation during sample preparation. By separating ADC samples from carrier ampholytes (CAs) prior to injection and enabling real-time mixing within the instrument, this approach effectively suppresses premature lactone ring opening and stabilizes charge variant profiles. Comparative studies between conventional premixing and onboard-mixing approach demonstrated that the latter significantly enhances reproducibility, particularly for acidic variants that are highly sensitive to structural conversion. Comprehensive method validation confirmed excellent precision, linearity, and sensitivity, with consistent performance across run-to-run and intra-day analyses. The results underscore the importance of controlling microenvironmental pH exposure in the analysis of chemically instable ADCs. The proposed onboard-mixing strategy provides a robust and efficient solution for icIEF-based characterization, reducing analytical artifacts while simplifying method development. This approach is broadly applicable to ADCs and other biotherapeutics containing pH-sensitive functional groups.

Hydrogen-Ion Concentration

Bioprospecting microbial genomes to expand the biocatalytic toolbox of rubber oxygenases.

A set of rubber oxygenases was discovered through phylogenetic analysis and AI-based structural modeling of complexes of the putative enzymes with a substrate mimicking cis-1,4-polyisoprene. Sixteen candidate proteins were selected from thermophilic microorganisms, all sequence-related to the Latex clearing protein from Streptomyces sp. K30 (LcpK30). Sequence truncation and solubility tags were then evaluated to enhance protein expression, with the SUMO tag proving to be the most effective. Including LcpK30, nine heme-containing oxygenases were successfully expressed in E. coli NEB 10-beta cells, purified (35-157 mg L-1 yield) and characterized. Steady-state kinetics revealed significant rubber latex-degrading properties for six of them, with the truncated SUMO-fused LcpK30 (SUMO-LcpK30T) showing activity in agreement with literature. Notably, the catalytic efficiencies of all the expressed homologs lay within one order of magnitude and the oxygenase from Thermomonospora echinospora was found to be particularly promising in terms of activity, especially at high latex concentrations (more than 1% w/v). The analysis of reaction mixtures by both HPLC and HPLC-MS confirmed the oxidation of cis-1,4-polyisoprene to form the expected isoprenoid oligomers (n = 2-12), whose distribution was consistent with the usual endo-type cleavage pattern in all but one case. This bioprospecting effort afforded a platform of new rubber-degrading enzymes with diverse efficiencies and product profiles, capable of adapting to targeted applications.

Oxygenases

Educational Effects of Electronic Documents and Videos on Parents' Responses to Acute Illness in Young Children: A Randomized Controlled Trial.

AIM: This study compared changes associated with electronic document-based and video-based education for parents responding to acute illness in young children, focusing on self-reported knowledge, anxiety, and satisfaction. METHODS: A randomized controlled trial with pre- and post-intervention measurements was conducted among 140 adults in Japan who self-reported raising a child under 3&#x2009;years of age and having experienced their child's acute illness. Participants were assigned to an electronic document group or a video group (n&#x2009;=&#x2009;70 each). Self-reported knowledge was assessed using a researcher-developed questionnaire, and anxiety was measured using the State-Trait Anxiety Inventory. Pre-post changes and between-group differences in change scores were examined. RESULTS: Total self-reported knowledge scores increased significantly in both groups (p&#x2009;<&#x2009;0.01), with no significant between-group difference. The video group showed significant improvements in items related to symptoms requiring attention at home and information sources, whereas the electronic document group improved in items related to symptoms requiring medical consultation and emergency calls. State and trait anxiety did not change significantly in either group. Satisfaction was high in both groups. CONCLUSIONS: Both educational formats may support parents' learning about responses to acute illness in young children, although appropriate formats may differ according to the educational content. Information provision alone may have limited effects on anxiety; therefore, future parent education should incorporate interactive and reassurance-focused approaches. TRIAL REGISTRATION: UMIN-CTR: UMIN000056457.

Humans

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50&#xa0;&#x3bc;M, and intracellular concentrations and cell viability were monitored over 48&#xa0;h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Reprogrammed Komagataella phaffii for enhanced secretory expression of human lactoferrin.

Human lactoferrin (hLF) is a multifunctional glycoprotein of the transferrin family derived from milk and mucosal secretions, which exhibits antibacterial, anti-tumor, and immunomodulatory functions, and is an important component of infant formula. Conventional methods for lactoferrin expression are often inefficient, primarily due to inadequate protein synthesis capabilities and poor stability within microbial hosts. Herein, a Komagataella phaffii yeast strain capable of high-level secretory expression of hLF was constructed by reprogramming the endoplasmic reticulum (ER) and vacuole using CRISPR/Cas9 technology. A dual-expression cassette containing the AOX1 promoter, an &#x3b1;-secretion signal peptide, the hLF gene, and a terminator was integrated into three different sites of the K. phaffii genome. The stepwise strategy combining expansion of the ER membrane involved in protein synthesis with knockout of vacuolar proteases further enhanced hLF production. Subsequently, 0.1&#x202f;g/L FeCl&#x2083; was added to the medium to reduce the toxicity of hLF and improve its stability. After high-density cultivation of K. phaffii through optimization of cultivation conditions in shake flasks and a 5&#x202f;L bioreactor, the secretory intact hLF titer reached 2214&#x202f;mg/L, representing a 76.3-fold increase achieved through these engineering strategies. In addition, antibacterial experiments demonstrated that this secretory hLF had a significant inhibitory effect on Escherichia coli, Staphylococcus aureus, and yeast. Overall, the developed K. phaffii protein expression platform enabled efficient production of lactoferrin, demonstrating its potential for expressing other lactoproteins.

Lactoferrin

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Angiotensin II regulates anxiety and social-affective top-down and bottom-up attention control in a sex-dependent manner.

BACKGROUND: The renin-angiotensin system (RAS) has been increasingly recognized as potent modulator of cognitive and affective functions, with angiotensin II type 1 receptor (AT1R) antagonists emerging as repurposing candidate for anxiety and stress-related disorders. However, it remains unclear whether transient AT1R blockade modulates emotional attentional control and whether these effects are sex-dependent. METHODS: We conducted a preregistered, randomized, double-blind, placebo-controlled pharmacological eye-tracking study in 79 healthy adults (males and females) and determined effects of transient AT1R blockade via losartan (50&#xa0;mg) on emotional attention control using a validated anti-saccade paradigm with social (emotional faces) and non-social stimuli. Treatment effects on state anxiety and oculomotor responses were characterized using traditional metrics and a novel trial-history informed dynamic control framework. RESULTS: Losartan reduced state anxiety irrespective of sex but induced sexually dimorphic effects on attentional control. In females, losartan enhanced performance by reducing endpoint error without altering latency. Conversely, in males, losartan increased endpoint error and prolonged latency of the first correct saccade. Trial-history analyses revealed losartan reduced error probabilities following errors and repeat trials in both sexes. Yet, following correct trials, females receiving losartan maintained lower error probabilities, while males exhibited higher errors, potentially reflecting failure to disengage from effortful control. CONCLUSIONS: The RAS modulates anxiety and attentional control, the latter sex-dependently. AT1R blockade reconfigures attentional processing and adaptive control, suggesting sex-specific therapeutic potential in disorders characterized by excessive anxiety and attentional dysregulation. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; https://clinicaltrials.gov/;NCT06329050.

Humans

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2&#xa0;ng/mL) for sunitinib and axitinib, 1&#xa0;ng/mL for pazopanib, 5-7&#xa0;ng/mL for sorafenib, 0.5-1.5&#xa0;ng/mL for regorafenib metabolic products, and 0.1-0.5&#xa0;ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000&#xa0;ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the &#x3bc;g/mL range and linearity of 10-240&#xa0;&#x3bc;g/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.

Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs&#xa0;-&#xa0;images that are appealing, recognizable, and appropriate&#xa0;-&#xa0;to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians&#xa0;-&#xa0;the primary target of the intervention to prevent wrong-patient errors&#xa0;-&#xa0;recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.

Female

Nanopore-based epigenomic profiling reveals the absence of widespread CpG methylation in the African swine fever virus genome.

DNA methylation is a critical epigenetic mechanism implicated in regulating replication and transcription in DNA viruses. However, the epigenetic landscape of African swine fever virus (ASFV), a large double-stranded DNA virus infecting pigs, remains controversial. Here, we systematically profiled the DNA methylome of the first ASFV strain isolated in Hong Kong (HK_NT_202103) using Oxford Nanopore Technologies (ONT) R10.4.1 sequencing. We employed a paired design: native whole-genome sequencing (WGS) against a methylation-free whole-genome amplification (WGA) control. Using conservative thresholds, we found no evidence of 5-methylcytosine (5mC), especially typical CpG methylation, across the viral genome. Importantly, clear CpG methylation signals were successfully detected in the host genome from WGS data, confirming the functionality of the workflow to detect 5mC at CG sites. While widespread 5mC seems absent, a small number of putative N6-methyladenine (6mA) loci were identified. A specific 6mA candidate exhibited raw ionic current disruptions and gene-level intersection with another ASFV isolate (CAS19-01/2019), although it lacked single-base consensus across different methylation callers or between the two isolates. Although our biological findings are restricted to a single isolate under specific experimental conditions, this study introduces a novel, highly rigorous ONT framework for viral epigenomics research. Furthermore, the absence of ASFV CpG methylation indicates that host CpG-depletion remains a viable strategy for viral metagenomic enrichment. Ultimately, our work offers a critical methodological baseline for ASFV surveillance and highlights the necessity of targeted experimental validation for rare viral modifications.

African Swine Fever Virus

Predicting ACL injury risk in athletes: A systematic review of machine learning-based models.

BACKGROUND: Early ACL injury risk identification in athletes is essential. This systematic review examines machine learning (ML) models for predicting ACL injuries, evaluating their methodological quality, performance, and reliability. METHOD: A comprehensive electronic search was conducted across PubMed, Scopus, Web of Science, and IEEE Xplore databases, supplemented by Google Scholar for grey literature, covering articles published between January 1, 2015, and August 30, 2025. Eligible studies were appraised using the Prediction Model Study Risk of Bias Assessment Tool (PROBAST) for methodological quality and risk of bias, and the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis (TRIPOD) guidelines for quality of evidence. RESULTS: Ten studies were included. PROBAST showed eight studies had moderate risk of bias and two low risk. TRIPOD found only two studies met quality criteria. ML models included logistic regression (n&#xa0;=&#xa0;5), support vector machines (n&#xa0;=&#xa0;4), k-nearest neighbor (n&#xa0;=&#xa0;3), decision trees (n&#xa0;=&#xa0;3), random forests (n&#xa0;=&#xa0;5), neural networks (n&#xa0;=&#xa0;2), linear discriminant analysis (n&#xa0;=&#xa0;1), and pre-trained CNNs (n&#xa0;=&#xa0;1). AUC ranged from 0.63 to 0.98. Accuracy (reported in six studies) ranged from 26% to 95%; however, these values should be interpreted with caution due to the absence of confidence intervals, lack of class imbalance handling, and limited external validation across studies. Tree-based ensemble methods such as random forest achieved competitive accuracy (74-86%), while SVM, a non-ensemble classifier, reported accuracy ranging from 71% to 95%; however, the highest values were obtained in studies with notably small sample sizes (n&#xa0;=&#xa0;12 to n&#xa0;=&#xa0;39), raising concerns about overfitting and generalizability. CONCLUSION: Current ML algorithms show promise for identifying athletes at high ACL injury risk and detecting relevant risk factors. Although study quality was generally satisfactory, future research should prioritize external validation and model interpretability to support clinical translation.

Humans