Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation.

It has been shown that quantitative MRI thermometry using the proton resonance frequency (PRF) method can be used to noninvasively monitor the evolution of tissue temperature, and to guide minimally-invasive tumor ablation based on local hyperthermia. Although hepatic tumors are among the main targets for thermal ablation, PRF-based temperature MRI of the liver is difficult to perform because of motion artifacts, fat content, and low T(*) (2). In this study the stability of real-time thermometry was tested on a clinical 1.5 T scanner for rabbit liver in vivo. The fast segmented EPI principle was used together with respiratory gating to limit respiratory motion artifacts. Lipid signal suppression was achieved with a binomial excitation pulse. Saturation slabs were applied to suppress artifacts due to flowing blood. The respiratory-gated MR thermometry in the rabbit liver in vivo showed a standard deviation (SD) of 1-3 degrees C with a temporal resolution of 3 s per slice and 1.4 mm x 1.9 mm spatial resolution in plane (slice thickness = 5 mm). The method was used to guide thermal ablation experiments with a clinical infrared laser. The estimated size of the necrotic area, based on the thermal dose calculated from MR temperature maps, corresponded well with the actual lesion size determined by histology and conventional MR images obtained 5 days posttreatment. These results show that quantitative MR temperature mapping can be obtained in the liver in vivo, and can be used for real-time control of thermal ablation and for lesion size prediction.

Animals↗

MRI monitoring of heating produced by ultrasound absorption in the skull: in vivo study in pigs.

The purpose of this study was to test the utility of MR thermometry for monitoring the temperature rise on the brain surface and in the scalp induced by skull heating during ultrasound exposures. Eleven locations in three pigs were targeted with unfocused ultrasound exposures (frequency = 690 kHz; acoustic power = 8.2-16.5 W; duration = 20 s). MR thermometry (a chemical shift technique) showed an average temperature rise in vivo of 2.8 degrees C +/- 0.6 degrees C and 4.4 degrees C +/- 1.4 degrees C on the brain surface and scalp, respectively, at an acoustic power level of 10 W. The temperature rise on the scalp agreed with that measured with a thermocouple probe inserted adjacent to the skull (average temperature rise = 4.6 degrees C +/- 1.0 degrees C). Characterization of the transducer showed that the average acoustic intensity was 1.3 W/cm(2) at an acoustic power of 10 W. The ability to monitor the temperature rise next to the skull with MRI-based thermometry, as shown here, will allow for safety monitoring during clinical trials of transcranial focused ultrasound.

Animals↗

[MRI-controlled regional hyperthermia].

PURPOSE: Regional hyperthermia in combination with chemotherapy or/and radiotherapy is a promising treatment concept for locally advanced, deep-seated tumors. The purpose of the project is the optimization of the therapy using non-invasive, three-dimensional imaging of tissue changes or of the temperature distribution during regional hyperthermia. METHODS: MRI offers methods suitable in principle for tissue characterization and MR thermometry. A new MRI-hyperthermia hybrid system has been developed based on an innovative hyperthermia applicator and an open MRI system. RESULTS: After successful testing of the new MRI-hyperthermia hybrid system simultaneous MRI and regional hyperthermia in patients could be accomplished for the first time. At present the T1 relaxation time seems to be a promising parameter for MR thermometry. CONCLUSION: The first clinical application of the MRI-hyperthermia hybrid system can be regarded as an important step towards the development of regional hyperthermia. This new hybrid system and the MR thermometry methods have to be investigated prospectively in clinical studies.

Equipment Design↗

A comparison of oral, tympanic, and rectal temperature measurement in the elderly.

This cross-sectional study enrolled 95 elderly Emergency Department patients aged 60 years or more to determine if rectal temperatures identify fevers more often than oral or tympanic temperatures when the chief complaint suggests an infection. A fever was defined as a temperature greater than 38 degrees C (100.4 degrees F). Discordance was defined as any patient with an oral or tympanic temperature of 38 degrees C or less but manifesting a rectal temperature greater than 38 degrees C and 0.5 degrees C (1 degrees F) greater than the oral or tympanic temperature. Rectal thermometry identified a fever in 14 of 95 (14.7%) patients who were afebrile orally and in 11 of 90 (12.2%) patients who were afebrile tympanically. Five of 90 (5.6%) patients were febrile rectally but were afebrile by both oral and tympanic thermometry. Thus, rectal thermometry identified fevers missed orally and tympanically in elderly patients whose presentation suggested infection. To identify these febrile patients with possible infection, clinicians must be attentive to elderly patients' vague clinical presentation.

Aged↗

Thermometric determination of cartilage matrix temperatures during thermal chondroplasty: comparison of bipolar and monopolar radiofrequency devices.

PURPOSE: To compare cartilage matrix temperatures between monopolar radiofrequency energy (mRFE) and bipolar RFE (bRFE) at 3 depths under the articular surface during thermal chondroplasty. We hypothesized that cartilage temperatures would be higher at all cartilage depths for the bRFE device than for the mRFE device. TYPE OF STUDY: Randomized trial using bovine cartilage. METHODS: Sixty osteochondral sections from the femoropatellar joint of 15 adult cattle were used for this study. Using a custom jig, fluoroptic thermometry probes were placed at one of the following depths under the articular surface: 200 microm, 500 microm, or 2,000 microm. RF treatment was performed either with fluid flow (F) (120 mL/min) or without fluid flow (NF) (n = 5/depth/RFE device/flow; total specimens, 60). Irrigation fluid temperature was room temperature (22 degrees C). Thermometry data were acquired at 4 Hz for 5 seconds with the RF probe off, for 20 seconds with the RF probe on, and then for 15 seconds with the RF probe off. During RF treatment, a 0.79-cm2 area (1.0-cm diameter) of the articular surface centered over the thermometry probe was treated in a paintbrush manner in noncontact (bRFE) or light contact (mRFE). RESULTS: Thermal chondroplasty with bRFE resulted in higher cartilage matrix temperatures compared with mRFE for all depths and regardless of fluid flow. Bipolar RFE resulted in temperatures of 95 degrees C to 100 degrees C at 200 microm and 500 microm under the surface, with temperatures of 75 degrees C to 78 degrees C at 2,000 microm. Fluid flow during bRFE application had no effect at 200 microm. Monopolar RFE resulted in temperatures of 61 degrees C to 68 degrees C at 200 microm, 54 degrees C to 70 degrees C at 500 microm under the surface, and 28 degrees C to 30 degrees C at 2,000 microm below the surface. A significant effect of fluid flow during mRFE application occurred at 200 microm (NF, 61 degrees C; F, 63 degrees C) and 500 microm (NF, 53 degrees C; F, 68 degrees C). CONCLUSIONS: In this study, we found significant differences between bRFE and a temperature-controlled mRFE device with regard to depth of thermal heating of cartilage in vitro. Bipolar RFE resulted in matrix temperatures high enough (>70 degrees C) to kill cells as deep as 2,000 microm under the articular surface. Fluid flow during thermal chondroplasty had the effect of significantly increasing cartilage matrix temperatures at 200 and 500 microm with the mRFE device. During thermal chondroplasty, bRFE creates greater matrix temperature elevations at equivalent depths and treatment duration than does mRFE. Excessive temperatures generated deep within the cartilage matrix could cause full-thickness chondrocyte death, in vivo.

Animals↗

Thermal monitoring: invasive, minimal-invasive and non-invasive approaches.

BACKGROUND: Thermal treatments need verification of effectiveness. Invasive intra-tumoural thermometry was established as a standard method several years ago. However, in deep heating, invasive techniques have disadvantages. Therefore, alternatives have been suggested and are under development. METHODS: In three phase II studies treating rectal cancer, cervical cancer and prostate cancer, this study replaced invasive (intra-tumoural) thermometry by tumour-related reference points or catheter sections in the rectum, vagina or urethra. Index temperatures and thermal dose parameters were determined. Two recent studies treated patients with recurrent rectal cancer and soft tissue sarcoma using non-invasive MR-thermometry employing the SIGMA-Eye applicator. The proton resonance frequency shift (PRFS) method was employed to generate MR-temperature distributions during the entire heat treatment in 10 min intervals (via phase differences). Fat correction (nulling specified regions in the fat tissue) was utilized to calibrate the method, in particular with respect to the B0-drift. RESULTS: Statistically significant correlations were found between response (downstaging, WHO) and thermal parameters in rectal cancer (37 patients, rectum measurement, T90, cum min T90 >or= 40.5 degrees C) and cervical cancer (30 patients, vagina, mean temperature and equ min 43 degrees C in a reference point). In prostate cancer (14 patients), a clear correlation was verified between long-term PSA control ( or= 40.5 degrees C). The mean MR-temperature in the tumour at steady-state as well as the mean T90 were significantly correlated with response for recurrent rectal carcinoma regarding palliation and analgesia (15 patients) and with pathohistological regression rate in soft tissue sarcoma (nine patients). CONCLUSIONS: For tumours in the pelvis and in the lower extremities, invasive measurements can be replaced by minimally-invasive or non-invasive techniques, which provide equivalent or even more complete information. Extending the application of these surveillance methods to abdominal tumours or liver metastases is a challenge, but strongly desirable for clinical reasons.

Clinical Trials, Phase II as Topic↗

Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease.

PURPOSE: The purpose of this study was to construct and perform preliminary functionality evaluations of a multilayer conformal applicator with provisions for thermal monitoring, tight conformity and simultaneous microwave heating and brachytherapy treatment of large-area contoured surfaces. MATERIALS AND METHODS: The multilayer conformal applicator consists of thermal monitoring catheters for fibre-optic monitoring of skin temperatures, a waterbolus, a PCB microwave antenna array, a dielectric spacer for brachytherapy considerations, brachytherapy catheters for delivering HDR radiation and an inflatable air bladder for improving conformity to contoured surfaces. The applicator also includes an elastic attachment structure to hold the applicator securely in place on the patient. The conformity of the applicator to irregular surfaces was evaluated through CT imaging of the applicator fitted onto a life-sized human torso phantom. The fluid flow dynamics of the waterbolus, which impact the effectiveness of temperature control, were evaluated with thermometry during a 19 degrees C step change temperature of the circulating water. RESULTS: CT imaging showed improved conformity to the torso phantom surface following the application of gentle inward pressure from inflating the outer air bladder. Only a small number of 1-5 mm sized air gaps separated the conformal applicator and tissue surface. Thermometry testing of the bolus fluid flow dynamics demonstrated temperature uniformity within +/-0.82 degrees C across a 19 x 34 x 0.6 cm area bolus and +/-0.85 degrees C across a large 42 x 32 x 0.6 cm area bolus. CONCLUSION: CT scans of the applicator confirmed that the applicator conforms well to complex body contours and should maintain good conformity and positional stability even when worn on a mobile patient. Thermometry testing of two different waterbolus geometries demonstrated that uniform circulation and temperature control can be maintained throughout large, complex bolus shapes.

Brachytherapy↗

Determination and validation of the actual 3D temperature distribution during interstitial hyperthermia of prostate carcinoma.

To determine the thermal dose of a hyperthermia treatment, knowledge of the three-dimensional (3D) temperature distribution is mandatory. The aim of this paper is to validate an interstitial hyperthermia treatment planning system with which the full 3D temperature distribution can be obtained in individual patients. Within a phase I study, 12 patients with prostate cancer were treated with interstitial hyperthermia using our multi electrode current source interstitial hyperthermia treatment (MECS IHT) system. The temperature distribution was measured from within the heating devices and by additional thermometry. The perfusion level was estimated and the heating implant reconstructed. The steady-state temperature distribution was calculated using our interstitial hyperthermia treatment planning system. The simulated temperature distribution was validated by individually comparing the measured and simulated thermo-sensors, both for the thermometry integrated with the heating applicators and the additional thermometry. The entire procedure was also performed on a no-flow agar-agar phantom. It was shown that the calculated temperature distribution of an individual patient during MECS interstitial hyperthermia is very heterogeneous. The validation indicates that the calculated temperature elevations match the measurements within approximately 1 degrees C. Possible improvements are more precise reconstruction, incorporation of discrete vasculature and using a temperature-dependent, heterogeneous perfusion distribution. Further technical improvements of the MECS-IHT system may also result in better temperature calculations.

Agar↗

MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh.

In this study, we propose a focused ultrasound surgery protocol that induces and then uses gas bubbles at the focus to enhance the ultrasound absorption and ultimately create larger lesions in vivo. MRI and ultrasound visualization and monitoring methods for this heating method are also investigated. Larger lesions created with a carefully monitored single ultrasound exposure could greatly improve the speed of tumour coagulation with focused ultrasound. All experiments were performed under MRI (clinical, 1.5 T) guidance with one of two eight-sector, spherically curved piezoelectric transducers. The transducer, either a 1.1 or 1.7 MHz array, was driven by a multi-channel RF driving system. The transducer was mounted in an MRI-compatible manual positioning system and the rabbit was situated on top of the system. An ultrasound detector ring was fixed with the therapy transducer to monitor gas bubble activity during treatment. Focused ultrasound surgery exposures were delivered to the thighs of seven New Zealand while rabbits. The experimental, gas-bubble-enhanced heating exposures consisted of a high amplitude 300 acoustic watt, half second pulse followed by a 7 W, 14 W or 21 W continuous wave exposure for 19.5 s. The respective control sonications were 20 s exposures of 14 W, 21 W and 28 W. During the exposures, MR thermometry was obtained from the temperature dependency of the proton resonance frequency shift. MRT2-enhanced imaging was used to evaluate the resulting lesions. Specific metrics were used to evaluate the differences between the gas-bubble-enhanced exposures and their respective control sonications: temperatures with respect to time and space, lesion size and shape, and their agreement with thermal dose predictions. The bubble-enhanced exposures showed a faster temperature rise within the first 4 s and higher overall temperatures than the sonications without bubble formation. The spatial temperature maps and the thermal dose maps derived from the MRI thermometry closely correlated with the resulting lesion as examined by T2-weighted imaging. The lesions created with the gas-bubble-enhanced heating exposures were 2-3 times larger by volume, consistently more spherical in shape and closer to the transducer than the control exposures. The study demonstrates that gas bubbles can reliably be used to create significantly larger lesions in vivo. MRI thermometry techniques were successfully used to monitor the thermal effects mediated by the bubble-enhanced exposures.

Adipose Tissue↗

Temperature measurement in critically ill orally intubated adults: a comparison of pulmonary artery core, tympanic, and oral methods.

OBJECTIVE: Core temperature measurement using a pulmonary artery (PA) catheter is considered the gold standard for measuring temperatures in critically ill patients. The objective of this study was to compare oral and tympanic temperature measurements (in both the oral and core equivalence modes) against PA core temperature measurements to determine which method was the most accurate and reliable in the absence of a PA catheter. DESIGN: Prospective, descriptive comparative analysis. PATIENTS: Convenience sample of 102 critically ill orally intubated patients with a PA catheter in place. SETTING: A 24-bed medical/surgical/trauma intensive care unit in a university-affiliated medical center. INTERVENTIONS: Four experienced intensive care unit nurses were trained in the use of temperature measurement with the oral, tympanic (both core and oral equivalence modes were used), and PA core methods. Simultaneous temperature measurements were then taken once in each subject using each method. The potential covariates that were analyzed were mean blood pressure, patient acuity using the Simplified Acute Physiology Score II, age, sex, ambient room temperature, and ventilator circuit temperature. MEASUREMENTS AND MAIN RESULTS: The training period indicated that it took more time to train experienced nurses in the use of tympanic thermometry than oral thermometry. Descriptive statistics were the following: core, x = 37.33 (SD = 0.89); oral, x = 37.18 (SD = 0.92); tympanic oral, x = 36.80 (SD = 0.93); and tympanic core, x = 37.12 (SD = 1.0). Bias averages were calculated and were significantly different from 0 for all three methods (oral-PA core, -0.15 [SD = 0.36]; tympanic core-PA core, -0.11 [SD = 0.57], tympanic oral-PA core, -0.52 [SD = 0.53]), indicating that there is some degree of decreased accuracy associated with each method when compared with PA core. However, scatter plots using the Bland and Altman methodology (Altman DG, Bland JM: Practical Statistics for Medical Research. London, Chapman and Hall, 1991) illustrate that the greatest variability is associated with the tympanic method. CONCLUSIONS: Temperature measurement is an important piece of clinical data in a critically ill patient population. We found oral thermometry to be the most accurate and reproducible method when a PA core measurement was not available.

APACHE↗

Comparison of rectal and infrared ear temperatures in older hospital inpatients.

OBJECTIVES: To assess the agreement between infrared emission detection (IRED) ear and rectal temperatures and to determine the validity of IRED ear thermometry in detecting rectal fever. DESIGN: Prospective, convenience sample, unblinded study. SETTING: An acute geriatric unit (teaching hospital) and a multidisciplinary intensive care unit. PARTICIPANTS: The study included 45 inpatients (26 women and 19 men), aged 78.3+/-6.9 years, admitted over a 4-month period. Twelve of the patients were definitely infected. MEASUREMENTS: Sequential rectal (RT) and ear temperature (ET) measurements were performed using mercury-in-glass and IRED ear thermometers, respectively. IRED ear temperatures were measured at both ears (unadjusted mode), with the highest of six ear temperatures considered the true value. RESULTS: Mean RT (37.39 degrees C +/- 0.52 degrees C) was significantly (P<.001) higher than mean ET (36.89 degrees C +/-0.59 degrees C). A highly significant positive correlation was found between RT and ET (slope = 0.69; 95% CI, 0.52-0.86; P<.001; r = 0.78). The mean bias (mean of the differences) between RT and ET was 0.50 degrees C +/-0.37 degrees C (95% CI, 0.41 degrees C-0.59 degrees C), and the 95% limits of agreement -0.22 degrees C and 1.23 degrees C (95% CI, -0.38 degrees C to 1.39 degrees C). According to the standard criterion (RT > or =37.6 degrees C), 14 patients were febrile. Using an optimum IRED ear fever threshold (37.2 degrees C), the sensitivity and specificity of IRED ear thermometry for predicting rectal fever were 86% and 89%, respectively (positive predictive value, 80%; negative predictive value, 93%). CONCLUSIONS: The degree of agreement between rectal temperature and the highest of six IRED ear temperatures was acceptable. Using an optimal IRED ear fever threshold of 37.2 degrees C (99 degrees F), IRED ear thermometry had acceptable sensitivity and specificity for predicting rectal fever.

Aged↗

A comparison of non-contact, subcutaneous, and rectal temperatures in captive owl monkeys (Aotus sp.).

BACKGROUND: Three methods of body temperature measurement were compared in owl monkeys: non-contact infrared thermometry, subcutaneous transponder, and rectal probe. METHODS: Forty owl monkeys (Aotus sp.) were used. Animals were implanted with subcutaneous microchip transponders. Infrared thermometry was used at three different sites. All measurements were taken and repeated randomly. RESULTS: Infrared and subcutaneous measurements did not agree well with rectal thermometry. Subcutaneous and rectal temperatures were highly repeatable, and subcutaneous temperatures were most agreeable to rectal temperatures. CONCLUSIONS: Further investigation is needed into subcutaneous implant sites and use of different infrared thermometers in this species.

Animals↗

Reflex epiphora in patients with dry eye symptoms: role of variable time Schirmer-1 test.

PURPOSE: To report reflex epiphora in patients with dry eye symptoms and describe the role of variable time Schirmer-1 test. METHODS: The study was conducted in 16 consecutive dry eye patients (32 eyes), nine male and seven female, aged 16 to 73 years (mean 48.56-/+16.68 years), presenting with reflex epiphora. Each eye was subjected to Schirmer-1 test and the time elapsed in total wetting of the 35 mm strip from its placement into the conjunctiva was noted and test was graded. This was compared with symptomatology, closed chamber infrared thermometry, humidity, fluorescein tear break-up time (FTBUT), fluorescein stain test, and Lissamine green stain. RESULTS: Schirmer-1 test differentiated reflex epiphora in dry eye patients into groups 0 to 4 based on time it took to wet the 35 mm strip (Group 0 = <=5 min; Group 1 = <=2 min; Group 2 = <=1.5 min; Group 3= <=1 min; Group 4 = <=1/2 min). The score was -0.04 in 8 eyes, -0.03 in 10 eyes, -0.02 in 2 eyes, -0.01 in 6 eyes, and 0.00 in 6 eyes in Groups 4, 3, 2, 1, and 0, respectively. Reflex epiphora had a statistically significant correlation to the symptomatology (p<0.001), lissamine green staining (p<0.001), closed chamber humidity difference (p<0.001), and FTBUT score (p=0.001). Fluorescein stain test and difference in infrared thermometry did not show any correlation. A statistically significant correlation existed between severe and mild to moderate reflex epiphora (p=0.002). However, the two groups separately failed to show any statistically significant relationship with the symptomatology (p=0.16), Lissamine green (p=0.69), humidity difference from close to open eye position (p=0.17), and FTBUT (p=0.25). Thermometry and fluorescein stain test showed no relationship. CONCLUSIONS: Schirmer-1 test with variable time quantifies reflex epiphora in dry eye patients, which was significantly related to the other tear function tests.

Adolescent↗

Accuracy of an infrared tympanic thermometer.

BACKGROUND: The use of infrared thermometry to measure temperatures in hospitalized patients is increasing. Although infrared thermometers have been proven to be accurate when they are used by well-trained personnel, no previous studies have examined their accuracy during routine hospital use. OBJECTIVE: To determine the accuracy and observer variability of temperatures measured with an infrared tympanic thermometer (TT). DESIGN: Prospective, observational study. SETTING: ICUs of a 300-bed teaching community hospital. PATIENTS: Fifty-one critically ill patients. MEASUREMENTS: The mean of three tympanic temperatures measured with the infrared TT (tempTTs) was compared to temperatures simultaneously measured with the thermistor of right heart catheters and rectal mercury thermometers for the following three groups of observers who had been certified in the use of the infrared TT: a single critical care nurse (CCN)/educator (Ed); CCNs, and floor nurses (FNs)/clinical care practitioners (CCPs). RESULTS: Two rounds of measurements were given to 51 patients by 153 observers. Temperatures of the pulmonary artery (PA) measured with the thermistor of right heart catheters (tempPAs) ranged from 96.5 to 102.6 degrees F, with a mean (-/+ SD) of 99.3+/-1.1 degrees F. The intraobserver variabilities (correlation coefficients) of the tempTTs ranged from 0.90 for those measured by FNs/CCPs, to 0.92 for those measured by CCNs, to 0.98 for those measured by the CCN/Ed. Accuracy, arbitrarily defined as within a deviation of -/+0.5 degrees F of the tempPA, was 100% for the rectal mercury thermometer and 98.0% for the infrared TT when used by the CCN/Ed. The accuracy of the infrared TT was 80% when measured by CCNs and 61% when measured by FNs/CCPs. Differences between tempPAs and tempTTs measured by the CCN/Ed ranged from 0 to 0.7 degrees F, with a mean of 0.2 degrees F. Similarly, differences between tempPAs and tempTTs measured by CCNs ranged from 0 to 2.4 degrees F, with a mean difference of 0.3 degrees F. However, differences between tempPAs and tempTTs measured by FNs/CCPs ranged from 0 to 3.0 degrees F, with a mean of 0.6 degrees F (greater differences than those obtained by the CCNs; p < 0.01). The accuracy of rectal mercury thermometry was 100%. If a temperature > or = 101.0 degrees F had been considered as the threshold at which a fever is present, and if the mean of three measurements had been used to designate temperature, workups that were either inappropriately performed or omitted would have resulted from 2% of tempTTs measured by the CCN/Ed, 1% of those measured by CCNs, and 4% of those measured by FNs/CCPs. CONCLUSION: When used properly, both tympanic and rectal thermometry are very accurate. However, the infrared TT produced measurements that were both less accurate and less reproducible when used by nurses who routinely used it in clinical practice.

Ear, Middle↗

Stanford University institutional report. Phase I evaluation of equipment for hyperthermia treatment of cancer.

From September 16, 1981, through April 4, 1986, a total of 21 radiative electromagnetic (microwave and radiofrequency), ultrasound and interstitial radio-frequency hyperthermia applicators and three types of thermometry systems underwent extensive phantom and clinical testing at Stanford University. A total of 996 treatment sessions involving 268 separate treatment fields in 131 patients was performed. Thermal profiles were obtained in 847 of these treatment sessions by multipoint and/or mapping techniques involving mechanical translation. The ability of these devices to heat superficial, eccentrically located and deep-seated tumours at the major anatomical locations is evaluated and the temperature distributions, acute and subacute toxicities, and chronic complications compared. Average measured tumour temperatures between 42 degrees C and 43 degrees C were obtained with many of the devices used for superficial heating; average tumour temperatures of 39.6 degrees C to 42.1 degrees C were achieved with the three deep-heating devices. When compared to the goal of obtaining minimum tumour temperatures of 43.0 degrees C, all devices performed poorly. Only 14 per cent (118/847) of treatments with measured thermal profiles achieved minimum intratumoural temperatures of 41 degrees C. Fifty-six per cent of all treatments had associated acute toxicity; 14 per cent of all treatments necessitated power reduction resulting in maximum steady-state temperatures of less than 42.5 degrees C. Direct comparisons between two or more devices utilized to treat the same field were made in 67 instances, including 19 treatment fields in which two or more devices were compared at the same treatment session. The analyses from direct comparisons consistently showed that the static spiral and larger area scanning spiral applicators resulted in more favourable temperature distributions. Three fibreoptic thermometry systems (Luxtron single channel, four channel and eight channel multiple [four] probe array), the BSD Bowman thermistor system and a thermocouple system were evaluated with respect to accuracy, stability and artifacts. The clinical reliability, durability, and patient tolerance of the thermometry systems were investigated. The BSD Bowman and third generation Luxtron systems were found clinically useful, with the former meeting all of our established criteria.

Adult↗

Optimization of hyperthermia with CT scanning.

In a prospective study CT scanning was used to evaluate the precision of thermometry catheter placement in tumours in the head and neck or on the chest wall in 30 consecutive patients prior to hyperthermia treatment. Patients had variable-sized tumours from several primary sites. Thermometry catheter placement was guided by palpation with or without a prior CT scan. Catheter placement was confirmed by CT. All lesions were less than 8 x 8 x 6 cm (L x W x D) in size. A mean of 4.2 +/- 0.2 (+/- 1 SEM, range 2-7) closed-end polyurethane catheters were inserted orthogonally by the same experienced radiation oncologist. Horizontal thermometry catheters were intended to traverse the centre and base of the tumour mass, and a vertical catheter was often inserted to intersect a horizontal catheter. After catheter placement, wire cables with 1 cm spacings were inserted into the catheters and positions determined using orthogonal films and CT scans. The success of catheter placement was judged on the following criteria: (1) catheter distribution factor (CDF = proportion of tumour CT slices transected by at least one catheter); (2) catheter hit ratio (CHR = average number of catheters in tumour per CT slice); (3) catheter miss factor (CMF = average number of catheters out of tumour per CT slice); (4) catheter placement index, CPI = [(CHR)(CDF)]-CMF; and (5) distance of nearest catheter from the visually estimated centre of tumour in the most central tumour CT scan. In the first seven lesions with 3-6 cm depth catheter insertion was guided by palpation only. In the next 23 lesions catheter insertion was guided by a prior CT scan. In the latter group, 15 lesions had depth 3-6 cm while eight lesions had depth < or = 3 cm. Catheter placement by palpation only, without the benefit of CT scan, was much less accurate in terms of the nearest catheter to the centre of the tumour (p = .001), the proportion of CT slices with catheter in tumour (CDF, p = 0.04) and the probability of a catheter being outside the tumour (CMF, p = 0.01). The catheter placement index (CPI) was a good measure of the accuracy and adequacy of catheter placement in large tumours (p = 0.04). Displacement of normal tissue structures by tumour precluded accurate catheter placement and led to a low CPI. It was difficult to accurately instrument lesions < or = 3 cm depth even with the benefit of a prior CT scan.(ABSTRACT TRUNCATED AT 400 WORDS)

Catheterization↗

Temperature field estimation using electrical impedance profiling methods. II. Experimental system description and phantom results.

An electrical impedance tomography system has been developed and tested for the purpose of thermal imaging. Since impedance changes with temperature, images of impedance subtracted from normothermic baselines will provide a map of temperature data. A system was designed to be operational at 10-50 kHz and to utilize 16 external electrodes around the periphery of a tissue-equivalent phantom encompassing the region of interest. These electrodes serve as current sources for the 5 mA constant-current inputs and are also used for reading differential voltages. Hyperthermia treatments for cancer require that internal thermometry probes be inserted into the tumour volume. Linear arrays of electrodes with thermometry tracks for micro-dimension thermometry serve this function, as well as providing localized voltage measurements in the region of interest. The embedded temperature sensors provide a quality assurance and calibration standard for the linear arrays in reconstruction of impedance profiles. Results of transient heating experiments with conductive and ultrasound heating are shown where image reconstruction is performed using a finite element model. Temperature predictions in these studies were accurate to better than 1 degree C on average when using information from surface electrodes combined with internal linear arrays. Maximum temperature errors, however, was found to be > 5 degrees C which suggests that further noise reduction during data acquisition and improvements in the reconstructions algorithms are needed.

Electric Impedance↗

Thermographic assessment of skin temperature during a cold provocation test.

A description was made of the development and application of infrared thermography and fingertip thermometry for the assessment of finger skin temperature during a cold provocation test. Three hundred and seventeen lumberjacks, grinders, metalworkers, stone cutters, and students were examined in laboratory and field investigations. Under laboratory conditions, the influence of water temperature and exposure duration was studied, and skin temperature measurements were made on the volar and dorsal side of the fingers. In the field occupational health examination, infrared thermography and fingertip thermometry were simultaneously applied during a cold provocation test. The following three types of temperature reaction could be recognized: normal rewarming and moderate delay and strong delay of rewarming. The temperature distribution along the finger length was analyzed. The following conclusions were drawn for practical application of the thermometric methods. Skin temperature must be measured on all 10 fingertips, either on the volar or on the dorsal surface. Fingertip thermometry may be used in occupational health examinations. Infrared thermography may yield more information on the development of disturbances in peripheral circulation along the finger length and may be used in special clinical work.

Adult↗