Temperature field estimation using electrical impedance profiling methods. II. Experimental system description and phantom results.

Abstract

An electrical impedance tomography system has been developed and tested for the purpose of thermal imaging. Since impedance changes with temperature, images of impedance subtracted from normothermic baselines will provide a map of temperature data. A system was designed to be operational at 10-50 kHz and to utilize 16 external electrodes around the periphery of a tissue-equivalent phantom encompassing the region of interest. These electrodes serve as current sources for the 5 mA constant-current inputs and are also used for reading differential voltages. Hyperthermia treatments for cancer require that internal thermometry probes be inserted into the tumour volume. Linear arrays of electrodes with thermometry tracks for micro-dimension thermometry serve this function, as well as providing localized voltage measurements in the region of interest. The embedded temperature sensors provide a quality assurance and calibration standard for the linear arrays in reconstruction of impedance profiles. Results of transient heating experiments with conductive and ultrasound heating are shown where image reconstruction is performed using a finite element model. Temperature predictions in these studies were accurate to better than 1 degree C on average when using information from surface electrodes combined with internal linear arrays. Maximum temperature errors, however, was found to be > 5 degrees C which suggests that further noise reduction during data acquisition and improvements in the reconstructions algorithms are needed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Moskowitz, K D Paulsen, T P Ryan, D Pang. Temperature field estimation using electrical impedance profiling methods. II. Experimental system description and phantom results.. https://doi.org/10.3109/02656739409009345

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Geophysical imaging of root-zone, trunk, and moisture heterogeneity.

The most significant biotic and abiotic stress agents of water extremity, salinity, and infection lead to wood decay and modifications of moisture and ion content, and density. This strongly influences the (di-)electrical and mechanical properties and justifies the application of geophysical imaging techniques. These are less invasive and have high resolution in contrast to classical methods of destructive, single-point measurements for inspecting stresses in trees and soils. This review presents some in situ and in vivo applications of electric, radar, and seismic methods for studying water status and movement in soils, roots, and tree trunks. The electrical properties of a root-zone are a consequence of their moisture content. Electrical imaging discriminates resistive, woody roots from conductive, soft roots. Both types are recognized by low radar velocities and high attenuation. Single roots can generate diffraction hyperbolas in radargrams. Pedophysical relationships of water content to electrical resistivity and radar velocity are established by diverse infiltration experiments in the field, laboratory, and in the full-scale 'GeoModel' at Kiel University. Subsurface moisture distributions are derived from geophysical attribute models. The ring electrode technique around trunks images the growth ring structure of concentric resistivity, which is inversely proportional to the fluid content. Healthy trees show a central high resistivity within the dry heartwood that strongly decreases towards the peripheral wet sapwood. Observed structural deviations are caused by infection, decay, shooting, or predominant light and/or wind directions. Seismic trunk tomography also differentiates between decayed and healthy woods.

Electric Impedance↗

Technology review: Esophageal impedance monitoring.

Intraluminal impedance monitoring is a new technique that can be used to detect the flow of liquids and gas through hollow viscera. In combination with manometry, it is used for esophageal function testing and while manometry provides information on contractile activity, impedance provides information on esophageal bolus transit. This is especially useful in patients with nonobstructive dysphagia. However, impedance monitoring appears to be less suitable for the evaluation of patients with achalasia. When used in combination with esophageal pH monitoring, impedance monitoring makes gastroesophageal reflux monitoring more complete because it allows recognition of both acidic and weakly acidic reflux episodes. The results of several studies suggest that impedance-pH monitoring is useful in the evaluation of patients with PPI-resistant typical reflux symptoms, chronic unexplained cough, excessive belching, and rumination.

Electric Impedance↗