Search PubMedSearch

SEARCH · Search PubMed

Results for “medical devices in Europe”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,959 records · Page 3Linked to original sources

Prophylactic Surgical Left Atrial Appendage Closure in Bioprosthetic Aortic Valve Replacement: Short-Term Outcomes of Randomized Controlled LAA-CLOSURE Trial.

BACKGROUND: Surgical closure of the left atrial appendage (LAA) reduces stroke risk in patients with atrial fibrillation (AF) undergoing cardiac surgery. We evaluated the safety and efficacy of prophylactic LAA closure during bioprosthetic surgical aortic valve replacement in patients without prior AF. METHODS: In this investigator-initiated, academic, randomized, open-label, multicenter LAA-CLOSURE (Left Atrial Appendage CLOSURE for the Prevention of Thromboembolisms in Patients Undergoing Aortic Bioprosthesis Surgery) trial, 921 patients without prior AF undergoing bioprosthetic surgical aortic valve replacement with or without concomitant surgery were randomized and 904 patients included in the modified intention-to-treat analysis (prophylactic LAA closure, n=445; or usual care, n=459). Median age was 73 years (interquartile range, 69-76), 34.8% were women, and 49% had concomitant coronary artery disease. The primary end point was a composite of cardiovascular death, stroke, or systemic embolism at 30 days. RESULTS: The primary end point occurred in 10 of 434 (2.2%) patients in the LAA closure group and 14 of 452 (3.1%) patients in the control group; however, the treatment effect changed direction at ≈7 days. In the time-split Cox regression model, hazard ratios were 2.4 (95% CI, 0.62-9.4; P=0.20) between 0 and 7 days and 0.29 (95% CI, 0.080-1.0; P=0.056) between 7 and 30 days. No closure-related serious complications or differences in bleeding were observed. Postoperative AF occurred in 205 of 445 (46.1%) versus 184 of 459 (40.1%) patients (relative risk, 1.1 [95% CI, 0.99-1.3]; P=0.07), and AF at discharge in 40 of 445 (9.2%) versus 34 of 459 (7.7%) patients (relative risk, 1.2 [95% CI, 0.77-1.8]; P=0.44), in the closure and control groups, respectively. CONCLUSIONS: Prophylactic LAA closure during bioprosthetic surgical aortic valve replacement was safe and did not increase bleeding. REGISTRATION: URL: clinicaltrials.gov; Unique Identifier: NCT02321137.

Aged

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC = 0.91-0.92 [0.83-0.97]; k = 55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC = 0.90-0.91 [0.85-0.95] (k = 228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs = 0.90 [0.83-0.94] (k = 124) and ICC = 0.91 [0.72-0.98] (k = 9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load–velocity relationship

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

The Effect of Slow Deep Breathing Relaxation Exercise on Pain and Anxiety Levels During and Post-Chest Tube Removal After CABG.

Chest tube removal after coronary artery bypass graft is frequently reported by patients as stressful and painful, highlighting the need for effective nonpharmacological interventions. Slow deep breathing relaxation exercises (SDBREs) may serve as a simple nursing strategy to reduce discomfort. In this study, we aimed to evaluate the effect of SDBRE on pain and anxiety during and after chest tube removal following coronary artery bypass grafting in Nablus hospitals. An experimental design was used with 80 patients recruited from 2 hospitals. Participants were randomly assigned to either an intervention group (n = 40) that practiced SDBRE or a control group (n = 40) that received standard care. Data were collected through a self-administered questionnaire, the Numeric Pain Scale, and the Visual Anxiety Scale. Data collection occurred from March to October 2024. The intervention group reported significantly lower pain scores during removal (M: 5.325 vs 7.125, P < .001) and after removal (P < .001). Anxiety scores were significantly lower both during and after removal (P < .001). Pain correlated with duration, with more complex operations and prolonged chest tube insertion linked to higher scores. SDBRE significantly reduced pain and anxiety during and after chest tube removal, supporting its integration into routine postoperative nursing care.

Humans

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

Effects of Vacuum Compression Therapy on Healing of Chronic Lower Limb Ulcers: A Randomised Controlled Study.

Chronic lower limb ulcers remain difficult to manage when unresponsive to conventional treatment. This study evaluated the clinical and physiological effects of vacuum compression therapy on wound healing and quality of life. Fifty patients with chronic lower limb ulcers were randomised to receive 12 sessions of vacuum compression therapy plus standard care or standard care alone over 4&#x2009;weeks. Wound dimensions, exudate, pain intensity and quality of life were assessed at baseline and post-treatment. Estimated wound volume was calculated as length&#x2009;&#xd7;&#x2009;width&#x2009;&#xd7;&#x2009;depth. Tissue oxygenation was measured at the dorsum of the foot in the experimental group. The vacuum compression therapy group showed greater improvements in wound width, depth, volume and quality of life. Estimated wound volume decreased by 61% in the intervention group, whereas no statistically significant volume reduction was observed in controls. Local tissue oxygenation in the experimental group increased by 43%. Baseline wound size was associated with poorer quality of life. Vacuum compression therapy may enhance wound healing and quality of life in patients with chronic lower limb ulcers. Observed increases in local tissue oxygenation represent exploratory physiological findings within the treated cohort that warrant controlled comparative evaluation. Trial Registration: ClinicalTrials.gov identifier: NCT07737184.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Changes in sexual behavior among women in studies evaluating the dapivirine vaginal ring for HIV prevention.

BACKGROUND: Access to novel HIV prevention technologies often raise concerns of risk compensation. This analysis examined changes in the sexual behaviors of MTN 020/ASPIRE participants, a placebo controlled randomized control trial, who subsequently enrolled in MTN-025/HOPE, an open-label extension using the dapivirine vaginal ring. METHODS: Both studies enrolled healthy, sexually active, HIV-negative women from Malawi, South Africa, Uganda and Zimbabwe. Longitudinal data on participants' sexual behaviors, specifically sex with a nonprimary partner (past 3&#xa0;months), and use of male or female condoms at the last vaginal sex act were compared between ASPIRE and HOPE. Conditional and mixed ordinal logistic regression models evaluated associations between study and sexual behaviors at enrollment,&#xa0;and quarterly over the first 12&#xa0;months. RESULTS: Of the 2629 individuals enrolled in ASPIRE, 1456 (55%) participated in HOPE. At enrollment, the proportion of participants who reported sex with a nonprimary partner and condom use at last vaginal sex act did not differ by study. Across all quarterly follow-up visits, sex with a nonprimary partner was more common in HOPE (13.9-18.7%) than ASPIRE (10.7-12.6%); adjusted OR&#xa0;1.47, 95% CI 1.24-1.75, P&#xa0;<&#xa0;0.001. There was no difference in condom use at the last vaginal act across all quarterly follow-up visits between ASPIRE (36.5-42.7%) and HOPE (43.6-46.7%); adjusted OR&#xa0;1.05, 95% CI 0.94-1.18. CONCLUSION: More women reported sex with nonprimary partners in HOPE, with little change in condom use over time between the two studies. Understanding behavior changes during PrEP use allows for tailored, holistic reproductive health programming.

Humans

Implementing a novel digital health platform for self-management of postmenopausal osteoporosis: A qualitative study of user experiences, perspectives and implementation outcomes.

BACKGROUND: Osteoporosis self-management requires scalable support, and digital health platforms may meet this need. This study aimed to characterise the experiences and perspectives of postmenopausal women who participated in a 12-month randomised controlled trial (RCT) of a digital voice assistant (DVA) delivered osteoporosis self-management intervention, and to assess key implementation outcomes. METHODS: This was a qualitative analysis of interviews with postmenopausal women from the intervention arm (DVA group) of the RCT. The DVA program broadcast education videos, medication reminders, home-based exercise, nutrition advice and monthly quizzes through a DVA device. Semi-structured interviews were recorded, transcribed and managed in NVivo through reflexive thematic analysis, guided by the Practical Planning for Implementation and Scale-Up and Proctor's implementation outcome taxonomy frameworks. Evidence weighting summarised participant coverage and code density. RESULTS: Twenty-two of 25 (88%) DVA group participants completed semi-structured interviews. Thematic analysis identified seven themes mapped to Proctor's implementation outcomes. Evidence weighting indicated strong support for the intervention's appropriateness and acceptability, moderate support for its adoption, fidelity, feasibility and sustainability, and limited support for costs. Participants valued clear audiovisual guidance, conversation-based interactions with natural language, and flexible home-based access to self-management. CONCLUSION: Digital health platforms for osteoporosis self-management appear feasible, acceptable and sustainable among postmenopausal women. Findings indicate that these platforms are approaching readiness for evaluation in implementation-focused settings, contingent on streamlined content, reliable delivery modalities, accessible user support, clear privacy regulations and pragmatic pricing models.

Humans

Effects of comprehensive oral care on nasogastric tube removal in long-term care residents with dysphagia: A multi-center randomized controlled trial.

Oral care is essential for residents in long-term care (LTC) facilities to reduce complications such as aspiration pneumonia. While routine oral hygiene is standard practice, comprehensive oral care (COC)-which includes facial and intraoral muscle massage, salivary gland stimulation, and oral moisturization-may further enhance swallowing function. However, evidence linking COC directly to nasogastric (NG) tube removal remains limited. This study evaluated the effectiveness of COC in facilitating NG tube removal and improving swallowing function among LTC residents with dysphagia. A multicenter, open-label randomized controlled trial was conducted across eight LTC facilities. The intervention group (n = 40) received daily one-on-one COC sessions lasting 30-40 min, while the control group (n = 37) received routine oral hygiene. Participants were followed for six months, with outcomes including NG tube removal, swallowing function, body weight, and pneumonia incidence. At six months, the COC group demonstrated a significantly higher NG tube removal rate, with eight participants achieving full oral intake (p = 0.005). Functional Oral Intake Scale scores were also significantly higher in the intervention group (p = 0.005). Time to NG tube removal ranged from 17 to 182 days. Under intention-to-treat principles, the NG tube removal rate remained significantly higher in the COC group (16.7%vs. 0%, p = 0.005). Competing risks analysis using the Aalen-Johansen estimator confirmed a 6-month cumulative incidence of NG tube removal of 14.6% in the COC group versus 0% in the control group (Gray's test: p = 0.005), with no significant between-group difference in mortality (p = 0.500). No significant differences were observed in body weight change or pneumonia incidence between groups. Among participants who successfully discontinued NG tube use, dementia was the most common underlying condition. These findings suggest that daily one-on-one COC is a feasible intervention in LTC settings and may improve swallowing function while facilitating NG tube removal in residents with dysphagia.

Humans

Chemoradiotherapy versus short-course radiotherapy for response-adapted organ preservation in early-stage and intermediate-stage rectal cancer (STAR-TREC): 12-month results of an international, multicentre, open-label, parallel-group, randomised, phase 2/3 trial.

BACKGROUND: Total mesorectal excision (TME) is the standard treatment for most early-stage and intermediate-stage rectal cancer but can cause substantial perioperative morbidity, functional impairment, and reduced quality of life. We assessed whether long-course chemoradiotherapy (LCCRT) or short-course radiotherapy (SCRT) could increase organ preservation and reduce surgery, toxicity, and quality-of-life harms without compromising oncological outcomes. METHODS: STAR-TREC is an international, multicentre, open-label, parallel-group, randomised, phase 2/3 trial in five European countries. Eligible patients were aged 16 years or older in the UK or aged 18 years or older elsewhere, had an Eastern Cooperative Oncology Group (ECOG) performance status of 0-1, and rectal adenocarcinoma (&#x2264;40 mm staged as mrT1-T3bN0). In phase 2, participants were randomly assigned (1:1:1) to LCCRT-based organ preservation (LCCRT-OP; 50 Gy in 25 fractions plus oral capecitabine 825 mg/m2 twice daily), SCRT-based organ preservation (SCRT-OP; 25 Gy in five fractions), or primary TME. Phase 2 assessed feasibility, with recruitment at months 12 and 24 as the primary endpoint and feasibility thresholds of four or more and six or more randomisations per month, respectively. Phase 3 adopted a partially randomised patient-preference design, allowing participants to choose either organ preservation or TME. Participants that chose organ preservation were randomly assigned (1:1) to receive LCCRT-OP or SCRT-OP using centralised, computer-generated assignment, with stratification by country and MRI T category (&#x2264;T3a vs T3b) using minimisation. The phase 3 primary endpoint was organ-preservation 30 months after treatment initiation, defined as absence of TME, stoma, or local recurrence, which was assessed in the modified intention-to-treat population, which included participants in phase 2 and phase 3. After a planned interim analysis of unmasked phase 2 data, the trial steering committee and independent data monitoring committee recommended reporting a 12-month, modified intention-to-treat analysis of implementation outcomes for participants recruited before Aug 8, 2023. This study is registered with ISRCTN (14240288) and is closed. FINDINGS: Between June 14, 2017, and April 8, 2024, 503 participants were enrolled at 37 sites. Phase 2 enrolled 120 participants, with recruitment rates of three and six participants per month at months 12 and 24, respectively. Overall, 12-month TME-free survival was 60% (47 of 78 participants). After phase 3 recruitment ended, interim analysis of unmasked phase 2 data showed an early TME-free survival benefit with LCCRT versus SCRT (12-month median TME-free survival not reached [95% CI not reached-not reached] vs 7&#xb7;6 months [95% CI 6&#xb7;4-not reached]; hazard ratio [HR] 3&#xb7;7 [95% CI 1&#xb7;7-8&#xb7;0]; posterior probability of superiority >99&#xb7;5%). The trial steering committee and independent data monitoring committee therefore recommended expanded analysis of 426 participants recruited before Aug 8, 2023: 120 from phase 2 and 306 from phase 3. 17 participants withdrew before treatment, leaving 409 in the modified intention-to-treat population: 163 allocated to LCCRT, 168 to SCRT, and 78 to primary TME. 116 (28%) participants were female and 293 (72%) were male. Among participants who opted for organ preservation, 12-month TME-free survival was 78&#xb7;5% (95% CI 72&#xb7;4-85&#xb7;1) with LCCRT and 60&#xb7;6% (53&#xb7;6-68&#xb7;4) with SCRT (HR 1&#xb7;90 [95% CI 1&#xb7;29-2&#xb7;81]). The most common grade 3-4 serious adverse events were gastrointestinal disorders (four [2%] with LCCRT vs six [4%] with SCRT vs six [8%] with TME) and procedural complications (three [2%] with LCCRT vs five [3%] with SCRT vs five [6%] with TME). One participant allocated to primary TME died after an anastomotic leak. INTERPRETATION: These early results support a response-adapted organ-preservation approach, with LCCRT appearing more effective than SCRT at 12 months. Organ-preservation might also reduce treatment-related toxicity compared with primary TME. Longer follow-up is needed for the prespecified 30-month endpoint and definitive functional and oncological outcomes. FUNDING: Cancer Research UK, Stand Up to Cancer, Dutch Cancer Society, Danish Cancer Society, Kom Op Tegen Kanker, Cancerfonden, ALF Region Stockholm, RCC Region Stockholm.

Humans

Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.

BACKGROUND: Wearable sensors are a promising method for collecting clinical trial outcome data for people with Angelman syndrome (AS). However, there has yet to be a systematic probe into the ways in which wearable sensors have been successfully used in AS. The current study aims to provide a quantitative summary of wearable sensors used in AS, including contexts of use and psychometric properties, and to present key narrative highlights. METHOD: Literature searches were performed in three electronic databases: APA PsycInfo, PubMed and Web of Science Core Collection. Data items were categorized into four categories: sample characteristics, study methodological details, wearable sensor characteristics and psychometric properties assessed. Sample characteristics included sample size, age, biological sex, race/ethnicity and cognitive/developmental functioning. Study methodological details were subdivided into study design and setting. Wearable sensor characteristics included sensor type, placement site, means of attachment, assessed construct and sensor-related data loss. Psychometric properties assessed included reliability and validity of sensor-derived data. RESULTS: We identified 16 articles through our systematic review. Wearable sensors were used to study sleep (n&#x2009;=&#x2009;10, 62.5%), language (n&#x2009;=&#x2009;2, 12.5%), gait (n&#x2009;=&#x2009;2, 12.5%), caregiver proximity (n&#x2009;=&#x2009;1, 6.3%), EEG power (n = 1, 6.3%),&#xa0;and arousal (n&#x2009;=&#x2009;1, 6.3%) in AS through actigraphs, vocalization recorders, inertial sensors, radio-frequency identification watches, wireless EEG caps,&#xa0;and functional near-infrared spectroscopy caps, respectively. Findings from these studies broadly indicate that wearable sensors are feasible, reliable and valid for assessing a range of behaviours relevant to AS. CONCLUSIONS: Wearable sensors are a promising solution to enhance assessments in AS. However, with the small extant literature characterized by small sample sizes and restricted focus on a few relevant features in AS, there remains ample opportunities to explore the use of wearable sensors in people with AS. Additional studies will better inform clinical decision-making and ultimately improve the lives of people with AS and their families.

Humans