Search PubMedSearch

SEARCH · Search PubMed

Results for “Immersive technologies”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

158 records · Page 3Linked to original sources

Teacher- Versus Video-Delivered Classroom Activity Breaks and Student Physical Activity: The PAAC-3 Trial.

BACKGROUND: Classroom activity breaks may increase moderate-to-vigorous physical activity (MVPA); however, few studies have compared teacher and video-delivered approaches under real-world conditions. METHODS: In this cluster randomized trial, 11 elementary schools were assigned to teacher-delivered (PAAC-T; 5 schools, 192 students) or video-delivered (PAAC-V; 6 schools, 276 students) classroom activity breaks across one academic year. Teachers were trained to deliver two 10-min breaks daily. Intervention delivery was tracked via a web-based platform, and classroom MVPA was assessed using accelerometers at baseline and follow-up. RESULTS: Implementation fidelity was low and highly variable, but comparable between PAAC-T (42.3&#x2009;&#xb1;&#x2009;57.1 activity breaks/teacher/year) and PAAC-V (39.2&#x2009;&#xb1;&#x2009;33.9; p&#x2009;=&#x2009;0.96), with teachers delivering &#x223c;50% of the intended daily activity. Classroom MVPA increased significantly in both groups (PAAC-T: 9.8&#x2009;&#xb1;&#x2009;15.9; PAAC-V: 9.1&#x2009;&#xb1;&#x2009;15.3&#x2009;min/day; p&#x2009;<&#x2009;0.001), with no intervention arm-by-time interaction (p&#x2009;=&#x2009;0.43). IMPLICATIONS FOR SCHOOL HEALTH POLICY, PRACTICE, AND EQUITY: Classroom physical activity breaks may increase student MVPA, but effectiveness in elementary schools appears to depend on implementation fidelity, administrative support, and equitable system-level infrastructure. CONCLUSIONS: Modest increases in classroom MVPA were observed across both delivery formats, although low and variable implementation fidelity limited conclusions regarding effectiveness and highlighted the need for stronger implementation supports. TRIAL REGISTRATION: NCT03493139.

Humans

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50&#xa0;&#x3bc;M, and intracellular concentrations and cell viability were monitored over 48&#xa0;h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Impact of adenosine in controlled aortic root reperfusion on clinical outcomes among patients undergoing valvular heart surgery.

BACKGROUND: Adenosine is a vital medication in cardiac surgery, particularly in valvular heart procedures. While its use has been linked to improved postoperative cardiac function in some studies, there remains significant uncertainty regarding the adenosine usage in aortic reperfusion phase. This lack of consensus poses challenges for surgeons, perfusionists, and anesthesiologists alike. This study aims to explore the impact of adenosine on clinical outcomes in patients undergoing valvular heart surgery. METHOD: This prospective randomized controlled trial was conducted over a three-month period. Sixty patients undergoing valvular heart surgery were enrolled using a continuous sampling method and randomly allocated into two equal groups of 30 patients each. The intervention group received adenosine-enriched aortic root reperfusion immediately prior to aortic declamping, while the control group underwent standard warm blood aortic root reperfusion. Both groups were matched for demographic and clinical characteristics to ensure comparability. RESULTS: Results indicated no significant differences in mean cardiopulmonary bypass (CPB) time, aortic cross-clamping duration, or mechanical ventilation between the intervention and control groups. However, the intervention group that received adenosine had a higher rate of antiarrhythmic agent usage in the operating room (P&#xa0;<&#xa0;0.05). Inotropic agent usage was similar in both groups during surgery and in the ICU. Additionally, laboratory parameters on the first day of ICU admission were comparable between groups. CONCLUSION: Results in the control group showed more favorable outcomes in terms of anti-arrhythmic drug usage, electroshock application, and arrhythmia prevalence. This study showed advantages for the standard warm blood aortic root reperfusion technique in managing post-operative cardiac rhythm disturbances, in comparison with the trial group.

Humans

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

Angiotensin II regulates anxiety and social-affective top-down and bottom-up attention control in a sex-dependent manner.

BACKGROUND: The renin-angiotensin system (RAS) has been increasingly recognized as potent modulator of cognitive and affective functions, with angiotensin II type 1 receptor (AT1R) antagonists emerging as repurposing candidate for anxiety and stress-related disorders. However, it remains unclear whether transient AT1R blockade modulates emotional attentional control and whether these effects are sex-dependent. METHODS: We conducted a preregistered, randomized, double-blind, placebo-controlled pharmacological eye-tracking study in 79 healthy adults (males and females) and determined effects of transient AT1R blockade via losartan (50&#xa0;mg) on emotional attention control using a validated anti-saccade paradigm with social (emotional faces) and non-social stimuli. Treatment effects on state anxiety and oculomotor responses were characterized using traditional metrics and a novel trial-history informed dynamic control framework. RESULTS: Losartan reduced state anxiety irrespective of sex but induced sexually dimorphic effects on attentional control. In females, losartan enhanced performance by reducing endpoint error without altering latency. Conversely, in males, losartan increased endpoint error and prolonged latency of the first correct saccade. Trial-history analyses revealed losartan reduced error probabilities following errors and repeat trials in both sexes. Yet, following correct trials, females receiving losartan maintained lower error probabilities, while males exhibited higher errors, potentially reflecting failure to disengage from effortful control. CONCLUSIONS: The RAS modulates anxiety and attentional control, the latter sex-dependently. AT1R blockade reconfigures attentional processing and adaptive control, suggesting sex-specific therapeutic potential in disorders characterized by excessive anxiety and attentional dysregulation. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; https://clinicaltrials.gov/;NCT06329050.

Humans

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2&#xa0;ng/mL) for sunitinib and axitinib, 1&#xa0;ng/mL for pazopanib, 5-7&#xa0;ng/mL for sorafenib, 0.5-1.5&#xa0;ng/mL for regorafenib metabolic products, and 0.1-0.5&#xa0;ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000&#xa0;ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the &#x3bc;g/mL range and linearity of 10-240&#xa0;&#x3bc;g/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.

Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs&#xa0;-&#xa0;images that are appealing, recognizable, and appropriate&#xa0;-&#xa0;to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians&#xa0;-&#xa0;the primary target of the intervention to prevent wrong-patient errors&#xa0;-&#xa0;recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.

Female

Emerging techniques of CRISPR/Cas system in antiviral therapy and diagnostics: Applications, limitations, and translational perspectives.

The CRISPR/Cas (clustered regularly interspaced short palindromic repeats) system is a versatile technology for developing antiviral medicines and editing viral genomes in both diagnostics and vaccine synthesis. Emerging insights into class 2 effectors, such as Cas9, Cas12, and Cas13, which target viral DNA and RNA, have revolutionized vaccines against viruses such as HIV, HPV, HBV, and EBV. Innovative diagnostic techniques such as SHERLOCK, DETECTR, and FELUDA have demonstrated system's diversity and accuracy in detecting the virus markers, supporting clinical decision-making, indicating adaptability and precision of CRISPR. This review critically evaluates CRISPR's role in RNA editing, emphasizing its importance for functional genomics and development of recombinant vaccines. Translational challenges are critically discussed, including off-target effects, delivery limitations, and ethical issues, for which unique approaches such as high-fidelity Cas variants, non-viral delivery systems, and bioethical frameworks are evaluated to address these limitations. This review also covers other social implications, such as accessibility and biosecurity risks, associated with CRISPR technologies Collectively, these advances underscore the transformative potential of CRISPR technologies in shaping next-generation antiviral diagnostics and therapeutics.

CRISPR-Cas Systems

SBUF-SMUF: On the path to the optimum hemofiltration technique in pediatric cardiopulmonary bypass: A randomized clinical trial.

BACKGROUND: Hemofiltration during pediatric cardiopulmonary bypass (CPB) is essential to mitigate hemodilution, inflammatory responses, and postoperative complications. Conventional ultrafiltration (CUF) is widely practiced, but novel methods such as subzero balanced ultrafiltration combined with simple modified ultrafiltration (SBUF-SMUF) may offer superior outcomes. OBJECTIVE: To compare the clinical efficacy and safety of CUF versus SBUF-SMUF in pediatric patients undergoing open-heart surgery. METHODS: In this prospective randomized, outcome-assessor-blinded clinical trial, 80 pediatric patients with congenital heart disease were allocated to either CUF (n = 40) or SBUF-SMUF (n = 40) during CPB. Baseline demographics, intraoperative characteristics, fluid balance, blood product utilization, and postoperative outcomes were assessed. Statistical analysis was conducted using independent t-tests, Chi-square tests, and Fisher's exact tests. Statistical significance was defined as a two-tailed p-Value of less than 0.05. RESULTS: Demographic and preoperative variables were comparable between groups. Mean fluid balance was significantly positive in the CUF group (+192.1 &#xb1; 178.8 mL) but negative in the SBUF-SMUF group (-105.0 &#xb1; 78.9 mL, p < 0.001). The SBUF-SMUF group required significantly less intraoperative PRBC (141.7 &#xb1; 70.2 vs. 261.0 &#xb1; 68.8 mL, p < 0.001) and postoperative FFP transfusion (2% vs. 10%, p = 0.020). Post-bypass hematocrit levels were higher (31.2% vs. 27.3%, p = 0.001) and extubation occurred earlier in the SBUF-SMUF group (1.05 &#xb1; 1.03 vs. 2.27 &#xb1; 2.37 days, p = 0.006). No significant differences were observed in potassium levels or incidence of acute kidney injury. CONCLUSION: The SBUF-SMUF technique is safe, effective, and superior to CUF in optimizing fluid balance, reducing blood product utilization, and facilitating earlier extubation in pediatric cardiac surgery. No additional risk of oliguria or electrolyte imbalance was observed compared to CUF. Its simplicity and reproducibility support its consideration as a standard approach in pediatric CPB.

Humans

Cost-Effectiveness of Electronic Patient-Reported Outcome Measure Interventions in Cancer: Systematic Review and Parameter Extraction for Economic Modeling.

BACKGROUND: Complex digital interventions that integrate electronic patient-reported outcome measures (ePROM) into clinical practice in cancer have the potential to improve quality of life, increase survival, and reduce health resource use and costs. Such systems can help patients with cancer self-manage chemotherapy symptoms, reduce clinicians' workloads through automated decision support, and resolve problems earlier. However, more research on the cost-effectiveness of ePROM monitoring is needed. OBJECTIVE: This paper comprises two complementary components: (1) a systematic literature review summarizing and evaluating the quantitative and qualitative evidence related to the cost-effectiveness of ePROM monitoring and (2) a health economic model parameter extraction. We also conducted supplementary targeted searches and scoping to provide context to our findings. METHODS: We searched Ovid (including MEDLINE and Embase), Scopus, and the International Health Technology Assessment Database for original English-language papers published on or before March 2025 using search strings that combined terms related to ePROMs, health economics, and cancer/oncology. We included papers reporting health economic-related outcomes for ePROM interventions designed for adult cancer populations and excluded screening tools and conference abstracts. RESULTS: We included 34 publications from 27 unique studies and identified and analyzed 26 ePROM-integrated interventions within these. Most (23/26) of the included interventions explicitly described some form of alert handling and automated decision support based on remote ePROM monitoring. Of the 34 publications, 5 presented full cost-effectiveness analysis results, of which 3 were highly uncertain and lacked clear differences in costs and health outcomes between ePROMs and standard care; conversely, 2 presented strong evidence of cost-effectiveness due to quality-of-life improvements, reduced hospitalizations, and potentially more autonomy in health-related travel (eg, ePROM-monitored patients can drive or walk to the hospital instead of using taxis or ambulances). A further 5 publications reported partial health economic results (eg, cost-consequence and budget impact), of which 1 detected no difference in strategies; in contrast, 4 reported lower health resource use and costs of ePROMs, mainly due to hospitalization reductions. Overall, 12 of the 27 studies included a qualitative component but mostly focused on user experience and design-related themes; only 2 of these addressed economic-specific themes (eg, changes in workflow and resource use due to ePROM implementation and integration), indicating some potential for time saving due to ePROM monitoring. CONCLUSIONS: Some ePROM-integrated interventions demonstrated cost-effectiveness in cancer care, but the evidence base remains limited. Where evidence does exist, cost-effectiveness appears driven by reduced hospitalization and improved quality of life. Qualitative research within the included studies rarely addressed economic questions. We provide a detailed parameter extraction for use in future economic modeling and recommend research priorities, including quantitative mapping of ePROM symptom data onto health resource use patterns, and qualitative work exploring how ePROM implementation affects clinical workloads and patient-perspective costs.

Humans