Search PubMedSearch

SEARCH · Search PubMed

Results for “Heart Valve Prosthesis Implantation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

192 records · Page 3Linked to original sources

Factors associated with periprosthetic joint infection following total knee arthroplasty: an updated systematic review and meta-analysis.

BACKGROUND: This study aimed to systematically evaluate factors associated with periprosthetic joint infection (PJI) following total knee arthroplasty (TKA), and thereby to provide evidence-based references for clinical prevention and perioperative risk stratification. METHODS: Computerized searches were conducted in the following databases from their inception until May 26, 2025: PubMed, Web of Science, Embase, the Cochrane Library, CINAHL, China National Knowledge Infrastructure, Wanfang Database, Chinese Scientific Journal Database, and Chinese Biomedical Literature Database. Two researchers independently screened the literature, extracted data, and assessed study quality. The methodological quality was assessed using the Newcastle-Ottawa Scale. Quantitative synthesis was performed when at least two studies reported comparable exposure definitions and sufficient comparator information; otherwise, narrative synthesis was used. Review Manager 5.4 software was used for the primary analysis. This study is registered on PROSPERO (CRD420251079339). RESULTS: A total of 25 observational studies were included in the qualitative synthesis, of which 24 contributed to the primary quantitative synthesis. Quantitatively pooled factors associated with PJI included male sex (OR = 1.39, 95% CI 1.27-1.51), BMI ≥30 kg/m2 (OR = 5.72, 95% CI 2.65-12.36), prolonged operative time, type 2 diabetes mellitus (OR = 2.09, 95% CI 1.45-3.01), rheumatoid arthritis (OR = 2.64, 95% CI 1.38-5.02), smoking (OR = 1.65, 95% CI 1.34-2.04), blood transfusion (OR = 2.27, 95% CI 1.59-3.25), American Society of Anesthesiologists score ≥3 (OR = 2.73, 95% CI 1.02-7.32), history of hormone therapy (OR = 4.88, 95% CI 2.90-8.22), postoperative urinary tract infection (OR = 3.59, 95% CI 1.15-11.21), intraoperative blood loss >200 ml (OR = 1.51, 95% CI 1.03-2.22), postoperative drainage tube placement duration ≥24 h (OR = 2.23, 95% CI 1.50-3.32), preoperative anemia (OR = 1.82, 95% CI 1.67-1.99), and combined pulmonary disease (OR = 5.54, 95% CI 1.93-15.96). Age was narratively summarized because its classification differed substantially across studies. CONCLUSION: Multiple demographic, comorbidity-related, and perioperative factors were associated with PJI after TKA. However, because the included studies were observational and clinically heterogeneous, these findings should be interpreted as associations rather than causal effects. Optimization of modifiable factors may help reduce the burden of PJI, but further prospective studies using standardized PJI definitions and adjusted effect estimates are required.

Humans

Intravenous Tranexamic Acid Reduces Perioperative Blood Loss in Reduction Mammoplasty With Immediate Implant-Based Reconstruction: A Randomized, Triple-Blinded, Placebo-Controlled Trial.

BACKGROUND: Postoperative hematoma and oozing can compromise outcomes after reduction mammoplasty with immediate reconstruction. Intravenous (IV) tranexamic acid (TXA) is antifibrinolytic, but prospective evidence in this setting is limited. OBJECTIVES: The aim of this study was to determine whether a single pre-incision dose of IV TXA reduces perioperative blood loss and fibrinolytic activation vs placebo. METHODS: In this randomized, triple-blinded, placebo-controlled trial, 60 women (American Society of Anesthesiologists I/II, 18-75 years) undergoing bilateral reduction mammoplasty with immediate implant-based reconstruction received TXA 10 mg/kg in 100 mL saline or placebo 10 min before incision. The primary outcome was total blood loss within 24 h (intraoperative suction + swab plus drain output). Secondary outcomes were perioperative changes in hemoglobin, D-dimer and fibrinogen, and complications within 30 days. Intention-to-treat analyses were performed. RESULTS: All patients completed follow-up. Total blood loss was lower with TXA than with placebo (mean ± standard deviation: 221.1 ± 72.4 vs 298.1 ± 90.6 mL; mean difference -77.0 mL; 95% CI, -122.4 to -31.6; P = .001). Intraoperative loss and 24 h drain output were also reduced. Postoperative D-dimer rise was attenuated with TXA (0.31 ± 0.15 vs 0.49 ± 0.22 µg/mL; P = .002); hemoglobin decline was smaller. No thromboembolic, neurologic, or allergic events occurred; no skin-flap necrosis was observed. CONCLUSIONS: Pre-incisional IV TXA safely reduces perioperative bleeding and fibrinolytic activity after reduction mammoplasty. These findings support incorporation of IV TXA into perioperative protocols. LEVEL OF EVIDENCE: 2 (THERAPEUTIC): For image description, please refer to the figure legend and surrounding text.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

An Overview of Red Breast Syndrome: A Qualitative Systematic Review of the Literature and a Single-Center Case Series.

Red breast syndrome (RBS) is an uncommon inflammatory complication that may occur following implant-based breast reconstruction and can clinically mimic surgical-site infection. This qualitative systematic review, based on comprehensive PubMed and Scopus searches, summarizes the existing literature on RBS, focusing on its etiology, clinical presentation, diagnostic characteristics, and therapeutic approaches following breast reconstruction using acellular dermal matrices (ADMs). A management protocol is proposed based on available data, and a single-center case series is presented from our Hospital, including patients who developed RBS after direct-to-implant reconstruction with ADM between January 2022 and December 2024. Twenty-nine studies met the inclusion criteria, comprising case reports, case series, and retrospective or prospective cohort studies. The reported incidence of RBS ranged from 0% to 29.6%. Proposed etiologies include endotoxin contamination, residual cellular debris, delayed hypersensitivity reactions, and lymphatic or vascular impairment of mastectomy flaps. Most reports described localized erythema confined to the area of the ADM, with normal inflammatory markers and negative imaging findings, whereas antibiotic therapy frequently failed to achieve improvement. Corticosteroids represented the most consistently effective treatment, although some cases required ADM removal or replacement. In our institutional case series (n = 8), symptom onset occurred between 4 weeks and 7 months postsurgery. Inflammatory markers remained within normal limits, imaging rarely demonstrated fluid collections, and symptoms resolved within days to weeks with corticosteroid therapy or conservative management. This review consolidates current evidence, proposes a diagnostic-therapeutic algorithm and highlights the need for prospective investigations and manufacturer-level endotoxin testing to elucidate pathogenesis and optimize clinical management. Level of Evidence: 2 (Risk) For image description, please refer to the figure legend and surrounding text.

Humans

Effects of erector spinae plane block on postoperative pain in patients undergoing implant-based breast reconstruction for breast cancer: a randomized controlled trial.

BACKGROUND: Implant-based breast reconstruction after mastectomy causes acute pain. OBJECTIVE: To determine whether a single-shot T5 erector spinae plane block (ESPB) reduces postoperative pain. DESIGN: Single-center, RCT with allocation concealment; blinded assessors and statisticians. SETTING: Tertiary cancer center in China. PATIENTS: 100 adults scheduled for radical mastectomy with implant reconstruction were randomized (1:1); follow-up complete. INTERVENTION: Before induction, ESPB was given under ultrasound guidance at T5 with 30 mL of 0.375% ropivacaine plus dexmedetomidine 1 &#x3bc;g/kg; controls received no block. Standardized general anesthesia and postoperative PCA for both groups. MAIN OUTCOME MEASURES: Resting NRS at 6 h (MCID=1). Secondary outcomes were opioid consumption, quality of recovery, and PONV. RESULTS: ESPB did not significantly reduce resting pain at 6 h at the median (&#x3c4; =0.50; adjusted difference -0.9; p = 0.08). At the upper tail, pain intensity was lower (&#x3c4; = 0.75; -1.8; p <0.01). Repeated measures provided additional time-point information, improving estimation precision and test sensitivity. ESPB get lower pain scores at 6, 12, and 24 hours (all p <0.01). But, the 95% CI includes the MCID, the clinical benefit remains uncertain. Opioid use decreased at 24 h (-13.5 mg; p <0.01) and 48 h (-6.6 mg; p <0.01). Quality of recovery improved at 24 h (difference 5 points; p <0.01), but not later. No differences were observed in intraoperative hemodynamics or PONV. CONCLUSIONS: Single-shot T5 ESPB with perineural dexmedetomidine may reduce postoperative pain and opioid requirements and improve early recovery. Further large trials are warranted. Clinical relevance remains to be confirmed. TRIAL REGISTRATION: ClinicalTrials.gov NCT06143020.

Humans

Bioabsorbable vs. titanium screws in first metatarsophalangeal joint arthrodesis: a pilot randomized controlled trial with 2-year follow-up.

INTRODUCTION: To assess the feasibility and preliminary clinical outcomes of bioabsorbable screw fixation in first metatarsophalangeal joint arthrodesis compared to conventional titanium screw fixation. METHODS: In this prospective pilot randomized controlled trial, 30 patients were allocated 1:1 to bioabsorbable or titanium cannulated lag screw fixation. Arthrodesis was performed using a cup-and-cone technique at two Finnish hospitals. Full weight-bearing in an orthopaedic shoe was allowed after six weeks. Outcomes included AOFAS and VA-FAS FA-VAS scores, union rates, and complications assessed at 3, 6, 12, and 24 months. RESULTS: Both groups showed significant functional improvement with no between-group differences. At 24 months, mean AOFAS scores were 89.1 (SD 2.7) in the titanium group and 90.0 (SD 0.0) in the bioabsorbable group (p = 0.23). Mean FA-VAS total scores (sum of pain, function, and complaints subscales) were 1948 (SE 59.4) in the titanium group and 1914 (SE 61.4) in the bioabsorbable group (p = 0.655). Union rate was 90% overall; nonunion occurred in one titanium and two bioabsorbable patients, all requiring revision. No implant-related complications or hardware removal surgeries were recorded. Degradation of bioabsorbable screws caused no adverse clinical or radiographic reactions. CONCLUSIONS: Bioabsorbable screws appear safe and feasible in first metatarsophalangeal joint arthrodesis, with preliminary outcomes comparable to titanium fixation. These findings support the conduct of a larger confirmatory trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03133039, registered 28 April 2017. https://clinicaltrials.gov/ct2/show/NCT03133039.

Humans

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3&#x2009;mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40&#x2009;mL, 2-3&#x2009;mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0&#x2009;mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

Flap Versus Tunneling for Horizontal Ridge Augmentation With FDBA and i-PRF: A Randomized Controlled Clinical Trial.

AIM: This study evaluated the efficacy of conventional flap and tunneling techniques for horizontal alveolar ridge augmentation using freeze-dried bone allograft (FDBA) particles combined with injectable platelet-rich fibrin (i-PRF). MATERIALS AND METHODS: Forty-five patients were randomly allocated to one of three groups (n&#x2009;=&#x2009;15 each): conventional flap (CF), tunneling with membrane (TM), or tunneling without membrane (TnM). Preoperative ridge width was measured via cone beam computed tomography (CBCT). All augmentation procedures incorporated FDBA and i-PRF; an absorbable collagen membrane was applied in the CF and TM groups. Follow-up assessments, including CBCT imaging and histomorphometric analysis, were conducted 6&#x2009;months postoperatively. For normally distributed data, ANOVA with Tukey's post hoc test and paired samples t-test were applied. Non-normally distributed data were analyzed using Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed-rank tests. RESULTS: Statistical analysis was performed on 43 patients. All groups demonstrated an increase in ridge width after 6&#x2009;months. At the 2&#x2009;mm level, the mean width gain was 1.28&#x2009;mm (95% CI: 0.17 to 2.40) in the TM group, 2.85&#x2009;mm (95% CI: 1.80 to 3.89) in the TnM group, and 1.95&#x2009;mm (95% CI: 1.07 to 2.83) in the CF group. However, statistical analysis revealed no significant intergroup variation (p&#x2009;>&#x2009;0.05). Histomorphometric assessments similarly demonstrated comparable outcomes across all groups, with no statistically significant differences observed (p&#x2009;>&#x2009;0.05). CONCLUSION: Within the limitations of this study, the tunneling technique, regardless of membrane use, appears to be a clinically viable alternative to the conventional flap method for horizontal alveolar ridge augmentation. However, further studies with longer follow-up periods are required to substantiate these findings. TRIAL REGISTRATION: irct.behdasht.gov.ir identifier: IRCT 20101204005305N21.

Humans

Sacral Neuromodulation in the Management of Refractory Pediatric Lower Urinary Tract Dysfunction.

INTRODUCTION: Sacral neuromodulation is currently used in the pediatric patient population for refractory lower urinary tract dysfunction (LUTD). Evidence, however, is currently limited for institutional experiences of long-term outcomes for sacral neuromodulation in the pediatric patient population. OBJECTIVE: The objective of this study is to perform a retrospective review of a large multi-institutional cohort of pediatric patients that underwent sacral neuromodulation (SNM) for refractory LUTD, focused on rates of symptom improvement, quality of life, and bowel-bladder dysfunction measures following device implantation. Secondary objectives included assessing device complication rates and device removals due to failure or successful resolution of symptoms. METHODS: We performed a retrospective cohort study of pediatric patients at three children's hospitals that underwent SNM device implantation for refractory LUTD. Patients 4-18 years of age who were diagnosed with refractory LUTD and managed at a participating institution with follow-up were included. Outcomes were evaluated at baseline and post-operatively after two-stage device implantation at initial follow-up and annually until device removal or final follow-up. RESULTS: From 2010 to 2022, a total of 205 children underwent SNM procedures at three pediatric hospital centers. 204 patients completed the two-stage procedure for permanent device implantation with a median follow-up of 3.4 years (1.3, 4.9). One hundred seventy-eight patients reported partial (25%) or complete (54%) device response/symptom improvement by final follow-up. Comparison of patient-reported validated questionnaires completed at baseline and by final follow-up visit revealed significant improvement in median Pediatric Quality of Life Inventory (PedsQL) (p&#x2009;=&#x2009;0.004) and Vancouver Nonneurogenic Lower Urinary Tract Dysfunction/Dysfunctional Elimination Syndrome bowel-bladder dysfunction (BBD) scores (p&#x2009;<&#x2009;0.001). Of those with any device complication (n&#x2009;=&#x2009;43;21%), 19 patients required device revision, and 20 required complete device removal. Separately, twenty-eight patients (13%) underwent device removal due to resolution of symptoms or treatment success at a median period of 5 years (4,7). CONCLUSION: SNM use demonstrated a majority of patients reporting at least partial subjective symptom improvement following device implantation across multiple institutions by final follow-up. SNM is a viable treatment option for refractory LUTD in the pediatric patient if willing to undergo an invasive procedure and in which thorough counseling of risks and benefits has occurred.

Humans

Pulmonary artery catheters or central venous catheters for cardiac surgery: the PUMA Pilot randomised clinical trial.

INTRODUCTION: Pulmonary artery catheters are used widely in cardiac surgery despite observed associations with worse outcomes and guidelines that recommend against their routine use. No adequately powered randomised trials are available. METHODS: The PUMA Pilot was a multicentre, randomised, parallel assignment, open-label, pilot and feasibility trial conducted at three tertiary cardiac surgery centres. Eligible patients were adults undergoing coronary artery bypass grafting, aortic valve replacement or surgery on the aortic root or ascending aorta with or without aortic valve replacement, with a predicted surgical mortality of <&#x2009;2%. Patients were allocated randomly to receive a pulmonary artery catheter or a central venous catheter inserted immediately before surgery. The primary feasibility outcome was protocol compliance, defined as receiving the assigned intervention without crossover. Secondary feasibility outcomes were eligibility rate; recruitment proportion and rate; data completeness; and rate of clinician refusal. RESULTS: We screened 480 patients and 206 (43%) were eligible; 150/203 (74%) approached provided informed consent. Three of 206 (1%) eligible patients were not included due to clinician refusal. Of 149 patients who were randomised, 76 were assigned to the pulmonary artery catheter group and 73 to the central venous catheter group. For the primary feasibility outcome, 147 patients (99%) received the allocated intervention. Data were complete for 144 (97%) patients. Median (IQR [range]) days alive and at home at 30&#x2009;days was 23.7 (21.9-24.7 [7.0-26.0]) in the pulmonary artery catheter group and 22.9 (20.8-23.9 [8.6-25.8]) in the central venous catheter group. Acute kidney injury occurred in 26/76 (34%) patients in the pulmonary artery catheter group and 14/73 (19%) in the central venous catheter group. DISCUSSION: A randomised trial of pulmonary artery catheters compared with central venous catheters in low-risk cardiac surgery is feasible. Such a trial would address significant practice variability and inform international guidelines.

Humans

Feasibility and efficacy of left bundle branch area pacing guided by modified chest lead 1.

BACKGROUND: Left bundle branch area pacing (LBBAP) typically requires 12&#x2011;lead electrocardiogram (ECG) measurements using an electrophysiology (EP) recording system. However, a simplified approach using modified chest lead 1 (MCL1) is potentially feasible. This study aimed to compare the success rate and pacing outcomes of LBBAP guided by MCL1 with those guided by the 12&#x2011;lead ECG using an EP recording system. METHODS: This retrospective, single-center study included patients with preserved left ventricular ejection fraction who underwent LBBAP for bradyarrhythmia. LBBAP was either guided by 12&#x2011;lead ECG using an EP recording system or by MCL1. In the MCL1 group, a follow-up examination with a 12&#x2011;lead ECG using an EP recording system was conducted within one week postoperatively. RESULTS: A total of 65 patients underwent LBBAP (EP recording system group: n&#xa0;=&#xa0;35; MCL1 group: n&#xa0;=&#xa0;30). The overall success rate of LBBAP was 84.6%, with no significant difference between groups (88.5% vs. 80.0%, p&#xa0;=&#xa0;0.49). No significant differences were observed in the paced QRS duration (140.4&#xa0;&#xb1;&#xa0;8.0 vs. 141.9&#xa0;&#xb1;&#xa0;13.1&#xa0;ms, p&#xa0;=&#xa0;0.54), V6-V1 interpeak interval (39.7&#xa0;&#xb1;&#xa0;16.5 vs. 38.3&#xa0;&#xb1;&#xa0;15.6&#xa0;ms, p&#xa0;=&#xa0;0.79), or V6 R-wave peak time (69.8&#xa0;&#xb1;&#xa0;12.3 vs. 71.5&#xa0;&#xb1;&#xa0;12.1&#xa0;ms, p&#xa0;=&#xa0;0.68). CONCLUSIONS: MCL1-guided LBBAP was feasible and achieved a high success rate, with outcomes comparable to those of conventional EP recording system-guided implantation. This simplified approach may reduce procedural complexity and may allow LBBAP implantation without the routine use of an EP recording system.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

Current Concepts and Emerging Technologies in Aesthetic Outcome Assessment of Breast Reconstruction.

Aesthetic outcomes are a crucial determinant of the overall success of breast reconstruction. Recently, aesthetic assessment has evolved from relying mainly on subjective impressions to incorporating more quantitative methods. This systematic review summarizes current concepts and emerging technologies in aesthetic outcome assessment after breast reconstruction. A comprehensive search of studies evaluating aesthetic outcomes following implant-based, autologous or hybrid breast reconstruction was performed between 2000 and 2025. Assessments were classified as subjective or objective. Extracted variables included assessment characteristics, aesthetic outcome domains, and patient-centered outcomes. Risk of bias was assessed using the Joanna Briggs Institute Critical Appraisal Checklist. Levels of evidence were classified according to the Oxford Centre for Evidence-Based Medicine. A total of 51 studies involving 7711 participants from 16 countries were included. Subjective tools were most frequently employed, led by the BREAST-Q (35/51, 69%), followed by expert- or panel-based evaluations (17/51, 33%) and the visual analog scale (2/51, 4%). Objective methods were applied in 19 studies and included 3-dimensional surface imaging (8/51, 16%), BCCT.core (7/51, 14%), eye tracking (3/51, 6%), and artificial intelligence-based analyses (3/51, 6%). Although subjective tools captured satisfaction with breast appearance, objective tools quantified morphological parameters and positional landmarks. BREAST-Q remains the cornerstone of outcome evaluation after breast reconstruction, providing patient-centered perspectives, including, but not limited to, aesthetic perception. A progressive shift toward multimodal evaluation was noticed, as no single modality comprehensively addressed all aesthetic domains. Future research should focus on integrating subjective and objective assessment methods within a unified framework. Level of Evidence: 3 (Therapeutic) For image description, please refer to the figure legend and surrounding text.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Modulation of heart rate and heart rate variability during animal-assisted treatment of patients in a minimally conscious state: A randomized controlled crossover study.

BACKGROUND: Animal-assisted treatment (AATx) is a promising and increasingly used approach in neurorehabilitation, yet its psychophysiological effects remain largely unexplored. Patients in a minimally conscious state (MCS) show severely altered consciousness with minimal but definite behavioral signs of awareness. Because behavioral assessment in this population is limited, psychophysiological measures such as heart rate (HR) and heart rate variability (HRV) may offer valuable insights into autonomic regulation during therapy. AIM: The present study investigated whether AATx influences HR and HRV compared to treatment as usual (TAU). METHODS: A randomized controlled crossover design with repeated measures was conducted. HR and HRV data were recorded using an Empatica E4 wristband, and linear mixed-effects models were fitted for each outcome variable. The analytic sample included twenty-one patients with MCS who completed at least one of the four sessions. RESULTS: We found a significant decrease in mean HR (estimate = -12.75, p&#x202f;=&#x202f;.041) and a significant increase in the standard deviation of normal-to-normal intervals (SDNN) (estimate = 15.76, p&#x202f;=&#x202f;.020) during AATx compared to TAU from the pretreatment to the posttreatment phase, indicating enhanced parasympathetic activation and greater autonomic flexibility. Other HRV parameters revealed no significant effects of AATx, though trends were consistent with the hypotheses. CONCLUSIONS: These findings provide preliminary physiological evidence that AATx can modulate autonomic activity in MCS patients. Despite limitations related to sample size and recording quality, the results highlight the potential of AATx as an emotionally engaging intervention in early neurorehabilitation.

Humans

Viscoelastic-Assisted Patient Interface Docking: A Technical Optimization in LenSx Femtosecond Laser-Assisted Cataract Surgery.

PURPOSE: To evaluate the efficacy of viscoelastic-assisted patient interface docking in LenSx (Alcon Laboratories, Inc) femtosecond laser-assisted cataract surgery (FLACS). METHODS: This was a randomized controlled trial. Patients undergoing FLACS from January to August 2025 at Aier Eye Hospital of Wuhan University were randomized via a random number table to receive balanced salt solution (BSS) or visoeleastic as the patient interface docking medium. The primary outcome was docking efficiency, measured by one-time docking success rate, the number of docking attempts, and mean docking time. Secondary outcomes included surgical safety (subconjunctival hemorrhage, capsulotomy completeness/tear rate), laser treatment duration (anterior capsulotomy time, nucleus pretreatment time, total laser emission time), and patient comfort (post-laser pain sensation). RESULTS: A total of 100 patients were enrolled, 50 in each group. Suction loss occurred in 7 patients (14%) in the BSS group and 1 patient (2%) in the viscoelastic group; the one-time docking success rate was significantly higher in the viscoelastic group (98%) than in the BSS group (86%) (chi-square = 3.93, P < .05). The viscoelastic group also had fewer mean docking attempts (1.02 &#xb1; 0.14) than the BSS group (1.16 &#xb1; 0.42), showing a significant difference (t = 2.23, P < .05). The viscoelastic group exhibited significantly shorter mean docking time (44.66 &#xb1; 4.47 seconds) compared to the BSS group (48.62 &#xb1; 3.11 seconds) (t = 2.17, P < .05). No significant differences were observed between the groups in subconjunctival hemorrhage, capsulotomy completeness/tear rate, anterior capsulotomy time, nucleus pretreatment time, total femtosecond laser emission time, or patient-reported pain sensation (all P > .05). CONCLUSIONS: Viscoelastic-assisted patient interface docking in FLACS effectively elevates one-time docking success rate, reduces docking attempts, and shortens docking time.

Humans