Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Space Suits”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Scanning for the scanner: FMRI of audition by read-out omissions from echo-planar imaging.

Echo-planar imaging (EPI) generates considerable acoustic noise by rapidly oscillating gradients. In functional magnetic resonance imaging (FMRI), unshielded EPI sounds activate the auditory system inasmuch as it is responsive. Instead of attenuating EPI noise, our goal was to utilize it for auditory FMRI by omitting read-outs from the pulse sequence's gradient train. Read-out gradient pulses are the primary noise determinant of EPI introducing its peak sound level and fundamental frequency peak which inversely relates to twice the echo spacing. Using model-driven analyses, we demonstrate that withholding read-outs from EPI is suited to reliably evoke hemodynamic blood oxygenation level-dependent (BOLD) signal modulations bilaterally in the auditory cortex of normal hearing subjects (n=60). To investigate the utility of EPI read-out omissions for auditory FMRI at an individual subject's level, we compare traditional Family-Wise-Error-Rate (FWER)-corrected maximum height thresholding to spatial mixture modeling (SMM). With the latter, appropriate bilateral auditory activations were confirmed in 95% of the individuals, whereas FWER-based voxel thresholding detected such activations in up to 72%. We illustrate the applicability of this novel EPI modification for clinical diagnostic purposes and report on a patient with bilateral large vestibular aqueducts (LVAs) and severe binaural sensorineural hearing loss (SNHL). In this particular case, read-out omissions from EPI were used to assert residual audition prior to cochlear implantation (CI). Requiring no specific task compliance or sophisticated stimulation equipment other than the scanner on its own, FMRI by read-out omissions lends itself to auditory investigations and to quickly probe audition.

Acoustic Stimulation↗

Regulation of transmitter release by high-affinity group III mGluRs in the supraoptic nucleus of the rat hypothalamus.

We analyzed the subtypes of group III metabotropic glutamate receptors (mGluRs) modulating inhibitory and excitatory transmission in the rat supraoptic nucleus. Bath application of the agonist l-AP4 at 200 microM, a concentration that activates all group III mGluR subtypes, inhibited the frequency but not the amplitude of miniature inhibitory and excitatory postsynaptic currents, indicating a presynaptic site of action. l-AP4 at low concentrations (10 microM), as well as ACPT-1 (50 microM), a specific mGluR III agonist, inhibited transmission at GABAergic and glutamatergic synapses to the same extent as 200 microM l-AP4. Because the potency of l-AP4 and ACPT-1 is much higher on mGluR4 and mGluR8 than on mGluR7, these results are consistent with the presence of high-affinity group III mGluRs regulating transmitter release in this nucleus. In agreement with these findings, DCPG (30 microM), a selective mGluR8 agonist, induced a significant depression of inhibitory and excitatory synaptic currents. Group III mGluRs such as mGluR8, because of their high affinity for glutamate, are particularly well suited to detect small changes in the concentration of this excitatory amino acid in the extracellular space. Their presence, therefore, may favor the negative feedback control exerted by glutamate on its own release as well as the intersynaptic crosstalk mediated by glutamate spillover on adjacent synapses.

Aminobutyrates↗

Structure determination of the [Fe(teec)(6)](BF(4))(2) metal complex from laboratory and synchrotron X-ray powder diffraction data with grid-search techniques.

The structure of the coordination compound [Fe(teec)(6)](BF(4))(2), hexa[1-(2-chloroethyl)tetrazole]iron(II) di(borotetrafluoride), has been determined using the grid-search techniques of the program suite MRIA. A Guinier-camera data set was used to determine the unit cell, the space group and to position the initial model. A high-resolution synchrotron powder data set was used to position a more detailed model using torsion-angle variation and to refine the structure leading to Rp = 0.0689, Rw = 0.0805 and GoF = 1.38. The crystal structure at room temperature shows the existence of two symmetry-equivalent iron(II) ions in the high-spin state.

Journal Article↗

Telemetry as a new concept in long term monitoring of SIDS-risk infant.

Sudden Infant Death Syndrome (SIDS) is the most frequent cause of infant death within the period of 2 to 12 months in western countries. It has been found that a suit similar to that worn by the astronauts during the execution of experiments on the Spacelab Mission D-2 is a very simple and useful means to carry the sensors required to monitor vital signs of babies at risk. A small baby-suit has been developed with the same technology used for the Spacelab Mission. The baby s suit is equipped with similar sensors to record thoracic and abdominal respiratory movements as its big -space travel brother-. This is a typical example of a successful technology transfer from medical aerospace activities into fields of daily clinical routine. In addition to the above described sensors, ECG-electrodes were integrated, as well as sensors to record vascular oxygen saturation and the corresponding pulse curve, and the baby s movements. All these vital signs are registered by a medical monitor, and permanently stored and automatically analysed online. In case of a life-threatening situation the system alerts simultaneously the personal at hospital and the parents at home. The requisite software algorithms have been developed by DLR in Cooperation with the pediatricians of the Pediatric Hospital in Köln-Porz, Cologne. When the system registers an alteration of the parameters above described -as a signal of a change in the baby s health condition- all vital signs are transfered in real-time to the supervising hospital via radio data transmission devices, mobile phone or a fixed network phone. The parents are also alerted by the device, and they can carry out the necessary reanimation procedures in case of an emergency. Parents will be trained in such actions when newborns must to be monitored. But nevertheless, they are guided and tele-assisted by an expert via telephone during the action. A clinical field trial, that will start in December 1999 at the Pediatric Hospital in Köln-Porz, Cologne, will evaluate the benefits of teleprotection by home monitoring of SIDS risk-babies.

Humans↗

[Hemodynamic indicators in men during constantly increasing overloads].

The effect of acceleration on central hemodynamics was investigated in centrifugation experiments. Also examined was the protective effect of muscle tension, anti-G suit, and of an altered acceleration vector. It was demonstrated that visual disorders were caused by a decrease in cardiac output. The countermeasures diminished the rate with which cardiac output declined due to the higher values of stroke volume that were produced by the anti-G suit and a changed body position. Arbitrary muscle tension ensured the effect only as a result of increased heart rate.

Acceleration↗

Urinary monitoring for diethylstilbestrol in male chemical workers.

Between 1969 and 1972 diethylstilbestrol (DES) accounted for 25 instances of breast tenderness and enlargement in male chemical workers in a DES production area of a large chemical plant. A gas chromatographic analysis for urinary DES was performed at three spaced intervals over a 90-day work span. All full-time workers who wore air suits when necessary developed increasing levels of DES upon increasing days of exposure. At a certain range of excretion (40 micrograms/ml/24 hours) two workers became symptomatic. DES was also detected in one helper and in two individuals not directly connected with the area of known exposure. Although no federal standard for DES exists, the following evidence points to the actuality of hazardous levels of exposure: (1) there had been a persistent history of DES reactions year after year; (2) high urine levels and adverse reactions were found in workers participating in the medical studies of this evaluation; and (3) there was widespread DES contamination of buildings and equipment, extending as far away as the lunchroom in a separate building.

Adult↗

Long-term survivorship of hip shelf arthroplasty and Chiari osteotomy in adults.

The current authors retrospectively assessed 56 hip shelf arthroplasties (48 patients) with a mean followup of 17 years (range, 15-30 years) and 89 Chiari osteotomies (82 patients) with a mean followup of 13 years (range, 6-25 years) done in adults with painful hip dysplasia. Preoperative joint space narrowing was observed in 32 of 56 shelf arthroplasties and in 67 of 89 Chiari osteotomies. Survival rates, using hip replacement as the end point, were 37% (20% to 54%) at 20 years for shelf arthroplasty and 68% (54% to 81%) at 18 years for Chiari osteotomy. The severity of preoperative arthrosis was the main factor that impaired the survivorship of shelf arthroplasty and Chiari osteotomy. With arthritic changes without joint space narrowing, the 18-year survival rates were 83% (69% to 97%) for shelf arthroplasty and 94% (89% to 99%) for Chiari osteotomy. Shelf arthroplasty is best indicated for moderate dysplasia (center edge angle >0 degrees) without severe arthrosis. Chiari osteotomy is best suited for severe dysplasia (center edge angle <0 degrees) especially without or with slight arthrosis. Chiari osteotomy also can be a salvage procedure when marked joint space narrowing is present but only if it is related to severe dysplasia (center edge angle <0 degrees).

Adolescent↗

Parallel sequence alignment in limited space.

Sequence comparison with affine gap costs is a problem that is readily parallelizable on simple single-instruction, multiple-data stream (SIMD) parallel processors using only constant space per processing element. Unfortunately, the twin problem of sequence alignment, finding the optimal character-by-character correspondence between two sequences, is more complicated. While the innovative O(n2)-time and O(n)-space serial algorithm has been parallelized for multiple-instruction, multiple-data stream (MIMD) computers with only a communication-time slowdown, typically O(log n), it is not suitable for hardware-efficient SIMD parallel processors with only local communication. This paper proposes several methods of computing sequence alignments with limited memory per processing element. The algorithms are also well-suited to serial implementation. The simpler algorithms feature, for an arbitrary integer L, a factor of L slowdown in exchange for reducing space requirements from O(n) to O(L square root of n) per processing element. Using this result, we describe an O(n log n) parallel time algorithm that requires O(log n) space per processing element on O(n) SIMD processing elements with only a mesh or linear interconnection network.

Algorithms↗

EEG source localization: implementing the spatio-temporal decomposition approach.

OBJECTIVES: The spatio-temporal decomposition (STD) approach was used to localize the sources of simulated electroencephalograms (EEGs) to gain experience with the approach for analyzing real data. METHODS: The STD approach used is similar to the multiple signal classification method (MUSIC) in that it requires the signal subspace containing the sources of interest to be isolated in the EEG measurement space. It is different from MUSIC in that it allows more general methods of spatio-temporal decomposition to be used that may be better suited to the background EEG. RESULTS: If the EEG data matrix is not corrupted by noise, the STD approach can be used to locate multiple dipole sources of the EEG one at a time without a priori knowledge of the number of active sources in the signal space. In addition, the common-spatial-patterns method of spatio-temporal decomposition is superior to the eigenvector decomposition for localizing activity that is ictal in nature. CONCLUSIONS: The STD approach appears to be able to provide a means of localizing the equivalent dipole sources of realistic brain sources and that, even under difficult noise conditions and only 2 or 3 s of available EEG, the precision of the localization can be as low as a few mm.

Artifacts↗

Central venous pressure in space.

Gravity affects cardiac filling pressure and intravascular fluid distribution significantly. A major central fluid shift occurs when all hydrostatic gradients are abolished on entry into microgravity (microG). Understanding the dynamics of this shift requires continuous monitoring of cardiac filling pressure; central venous pressure (CVP) measurement is the only feasible means of accomplishing this. We directly measured CVP in three subjects: one aboard the Spacelab Life Sciences-1 space shuttle flight and two aboard the Spacelab Life Sciences-2 space shuttle flight. Continuous CVP measurements, with a 4-Fr catheter, began 4 h before launch and continued into microG. Mean CVP was 8.4 cmH2O seated before flight, 15.0 cmH2O in the supine legs-elevated posture in the shuttle, and 2.5 cmH2O after 10 min in microG. Although CVP decreased, the left ventricular end-diastolic dimension measured by echocardiography increased from a mean of 4.60 cm supine preflight to 4.97 cm within 48 h in microG. These data are consistent with increased cardiac filling early in microG despite a fall in CVP, suggesting that the relationship between CVP and actual transmural left ventricular filling pressure is altered in microG.

Adult↗

Coronary MRA with 3D undersampled projection reconstruction TrueFISP.

Undersampled projection reconstruction (PR) offers improved imaging efficiency allowing a relative tradeoff between signal-to-noise ratio (SNR) or streak artifact and the number of acquired k-space views rather than the tradeoff between resolution or aliasing artifact and the number of acquired k-space lines inherent to Fourier imaging techniques. TrueFISP (true fast imaging with steady state precession) is ideally suited for undersampled PR imaging because of its inherently high SNR. The purpose of this work was to investigate the feasibility of using undersampled three-dimensional (3D) PR TrueFISP for breathhold coronary artery imaging. Phantom studies and a preliminary in vivo comparison demonstrated the improved spatial resolution of PR over Fourier TrueFISP with the same imaging time. In a 24-heartbeat coronary imaging scheme, segmented 3D PR TrueFISP provided a 1.0 x 1.0 mm(2) isotropic in-plane voxel size while acquiring between 93 and 153 views per partition. Streak artifacts were present in some images but were not found to impede coronary artery delineation. In conclusion, 3D undersampled PR TrueFISP provides isotropic in-plane voxel size within a single breathhold and is a promising technique for coronary artery imaging.

Arteries↗

Crystallization of Old Yellow Enzyme illustrates an effective strategy for increasing protein crystal size.

Old Yellow Enzyme (OYE) was the first flavoenzyme discovered, and has been widely used as a model flavoenzyme. Three crystal forms have been grown from natural protease-nicked OYE and one has been grown from intact recombinant OYE. The recombinant OYE crystals are best suited for structure determination and grow from a solution containing polyethylene glycol and MgCl2. They belong to space group P4(3)2(1)2 with unit cell dimensions a = b = 142.88 A, c = 43.01 A and have a single OYE chain per asymmetric unit. In order to optimize the production of large single crystals, we have carried out a systematic study of crystal size versus drop volume. Crystallographic lore holds that the volume of the medium in which the crystals are grown should have a significant effect on the final size of the crystals produced. However, a systematic investigation of the degree to which the volume of the crystallization sample affects the final size of the crystals has not been reported. In order to investigate this phenomenon, drops were set up in both hanging and sandwich geometry at a variety of drop volumes, but otherwise identical crystallization conditions. A 60-fold increase in drop volume produced a 730-fold increase in crystal volume, and a simultaneous increase in the effective diffraction limit of the crystals from near 2.5 A to well beyond 2.0 A resolution. The dramatic crystal volume increase appears to be due both to the increased amount of protein and the slower equilibration rates associated with larger drops. Our results also emphasize that the quality of diffraction data may often be limited by crystal size rather than intrinsic crystal order even in the case of reasonably sized (200 to 400 microns) crystals.

Crystallization↗

Functional structure of the organ of Corti: a review.

The mammalian auditory organs have a dual sensory system (inner vs. outer hair cells) with distinctly different cellular organizations and innervation patterns. However, the inner (IHCs) and outer (OHCs) hair cells are mechanoreceptors sharing similar general characteristics such as organization of stereocilia (including linkage system) and a gradation of stereociliary height along the length of the cochlea. This gradation of stereociliary height may be the single most important anatomic feature in the tuning capability of the sensory cell. Several lines of evidence suggest that the stereociliary stiffness may be modulated by the sensory cells themselves, most likely via the cuticular plate-rootlet complex. The stereociliary bundles of both types of hair cell are organized in a 'W' formation with a steplike arrangement. In the OHCs, the 'W' formation is sharply angulated and slanted toward the apex, coinciding with the slanted fiber arrangement of the overlying tectorial membrane, which is firmly coupled to the tips of the tallest row of the stereociliary bundles. However, in the IHCs, the 'W' formation is wide and its long axis is linear and arranged at a right angle to the radial axis of the organ of Corti; also, the ciliary bundles are freestanding (with a few exceptions in the basal turn). This arrangement in the IHCs would be best suited for deflection by the radial flow of the endolymph. Present evidence suggests that the subtectorial fluid space exists, is filled with endolymph, and freely communicates with endolymph. Because of the discovery of the phenomenon of 'cochlear emission', the possible motility of the sensory cells, particularly of the OHCs, has drawn intense interest in recent years. Recent investigations with dissociated sensory cells (OHCs) indicate some motile capability under various experimental conditions, although it has not been established that this motility is present in vivo. For this reason, the specialized cellular organization for motility and localization of contractile and cytoskeletal proteins have been investigated. These results support the possibility that the OHCs may have cellular facilities for this function.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Obtaining more accurate Fourier transform ion cyclotron resonance mass measurements without internal standards using multiply charged ions.

Space-charge effects produce frequency shifts in Fourier transform ion cyclotron resonance (FTICR) mass spectrometry and correction for these shifts is necessary for obtaining accurate mass measurements. We report a novel method for obtaining accurate mass calibration to correct for space-charge induced mass shifts without the requirement for internal calibrants. The new approach is particularly well suited for electrospray ionization-FTICR mass spectra that contain multiple charge states of the same molecular species. This method, deconvolution of Coulombic affected linearity (DeCAL), is described and presented with several examples demonstrating the increased mass measurement accuracy obtained. DeCAL provides the basis for more routinely obtaining higher mass accuracy measurements in conjunction with chromatographic separations for complex mixture analysis, and obviates the need for internal calibration in many applications.

Algorithms↗

G-protein-coupled receptor microarrays for multiplexed compound screening.

Conventional assay methods for discovering and profiling drug-target interactions are typically developed on a target-by-target basis and hence can be cumbersome to enable and orchestrate. Herein the authors report a solid-state ligand-binding assay that operates in a multiplexed mode to report compound activity against a micorarray-configured panel of G-protein-coupled receptor (GPCR) targets. The pharmacological fidelity of the system is high, and its miniaturized "plug-and-play" format provides improved efficiency both in terms of execution time and reagent consumption. Taken together, these features make the system ideally suited to explore the structure-activity relationship of compounds across a broad region of target class space.

Drug Evaluation, Preclinical↗