Search PubMed⌕ Search

PubMed · 9872437

EEG source localization: implementing the spatio-temporal decomposition approach.

Abstract

OBJECTIVES: The spatio-temporal decomposition (STD) approach was used to localize the sources of simulated electroencephalograms (EEGs) to gain experience with the approach for analyzing real data. METHODS: The STD approach used is similar to the multiple signal classification method (MUSIC) in that it requires the signal subspace containing the sources of interest to be isolated in the EEG measurement space. It is different from MUSIC in that it allows more general methods of spatio-temporal decomposition to be used that may be better suited to the background EEG. RESULTS: If the EEG data matrix is not corrupted by noise, the STD approach can be used to locate multiple dipole sources of the EEG one at a time without a priori knowledge of the number of active sources in the signal space. In addition, the common-spatial-patterns method of spatio-temporal decomposition is superior to the eigenvector decomposition for localizing activity that is ictal in nature. CONCLUSIONS: The STD approach appears to be able to provide a means of localizing the equivalent dipole sources of realistic brain sources and that, even under difficult noise conditions and only 2 or 3 s of available EEG, the precision of the localization can be as low as a few mm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Z J Koles, A C Soong. 1998. EEG source localization: implementing the spatio-temporal decomposition approach.. https://doi.org/10.1016/s0013-4694(98)00084-4. https://searchpubmed.org/record/pubmed%3A9872437/eeg-source-localization-implementing-the-spatio-temporal-decomposition-approach

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗