Search PubMedSearch

SEARCH · Search PubMed

Results for “Traditional Chinese medicine”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

482 records · Page 22Linked to original sources

Optimising Exercise Prescription: A Meta-Analysis Examining the Dose Response of Exercise Duration on Cardiorespiratory Fitness Following HIIT and MICT.

BACKGROUND: High-intensity interval training (HIIT) is often promoted as a time-efficient alternative to moderate-intensity continuous training (MICT) for improving cardiorespiratory fitness, yet the duration of HIIT sessions varies considerably across studies. OBJECTIVE: We aimed to characterise the dose-response relationship between exercise session duration and the improvement in cardiorespiratory fitness for HIIT and MICT. METHODS: A dose-response meta-analysis of randomised controlled trials comparing exercise duration in HIIT and MICT, following Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines and registered in PROSPERO (CRD42022335590). Effect sizes were calculated using a random-effects meta-analysis. The primary outcome was maximal oxygen uptake (VO2max). Secondary outcomes included blood pressure, lipid profiles, glucose metabolism markers and body composition measures. A one-stage random-effects dose-response meta-analysis was performed to examine the relationship between exercise duration and adaptations. We searched PubMed and Google Scholar; eligibility criteria for selecting studies were randomised controlled trials in humans, published in English and exercise interventions lasting at least 4&#xa0;weeks. RESULTS: We identified 69 randomised controlled trials (2387 participants). High-intensity interval training elicited greater improvements in VO2max than MICT (d = 0.38, 95% confidence interval 0.27-0.49, p < 0.001). High-intensity interval training demonstrated a non-linear dose-response relationship between exercise session duration and VO2max, with 80% of maximal effect (changes in VO2max = 3.45&#xa0;mL/kg/min) achieved with only ~11&#xa0;min/session (95% confidence interval 9.5-40.2). Moderate-intensity interval training showed a linear dose-response relationship between exercise session duration and VO2max, requiring ~52&#xa0;min/session to achieve 80% of the&#xa0;maximal observed&#xa0;effect (95% confidence interval 30.4-55.8). The dose-response relationship was consistent across populations. High-intensity interval training and MICT had comparable effects in improving cardiometabolic risk factors. CONCLUSIONS: High-intensity interval training demonstrated a non-linear dose response, with 80% of maximal effect on VO2max in ~11&#xa0;min/session, whilst MICT required four to five times longer to reach similar responses. The different types of training had comparable effects on cardiometabolic risk factors.

Journal Article

Association of Early Knee Extension Range of Motion Deficits With Cartilage T2 Relaxation Following Anterior Cruciate Ligament Reconstruction.

BACKGROUND: Anterior cruciate ligament (ACL) injury significantly increases the risk for developing knee osteoarthritis (OA), yet the early contributors to cartilage degeneration remain poorly understood. While range of motion (ROM) deficits after ACL reconstruction (ACLR) are associated with long-term development of radiographic OA, the association between early ROM recovery and cartilage composition has not been established. HYPOTHESIS: Knee extension ROM deficits at 2 months after ACLR would be associated with worsening tibiofemoral and patellofemoral cartilage T2 relaxation times at 6 months. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: A total of 30 participants (15-35 years) were enrolled within 1 month of ACL injury and before ACLR. At 2 months post-ACLR, active knee extension ROM was measured in the supine position using a goniometer. An extension deficit was considered >3&#xb0; less extension in the injured knee compared to the uninjured side. Quantitative magnetic resonance imaging-based T2 relaxometry of the injured knee was performed preoperatively and at 6 months post-ACLR to measure percent change in mean T2 relaxation times in predefined tibial and femoral cartilage regions. Independent t tests were used to compare changes in T2 values between participants with and without an extension deficit. RESULTS: The mean age of the participants was 18.8 &#xb1; 3.9 years, and 63.3% were female. Fifteen (50.0%) participants exhibited an extension deficit at 2 months. Those with an extension deficit demonstrated a greater increase in T2 relaxation time in the anterior (mean difference, 10.21% [95% CI, 3.67%-16.76%]; P = .003) and weightbearing (mean difference, 6.14% [95% CI, 2.19%-10.09%]; P = .004) cartilage of the medial femoral condyle. No significant group differences were observed in other cartilage regions (all P > .05). CONCLUSION: Knee extension ROM deficits at 2 months post-ACLR are associated with early compositional changes in the medial femoral cartilage, indicating a potential relationship between limited extension and OA risk.

Humans

Characteristics of p53 and Smad4 immunohistochemistry in pancreatic ductal adenocarcinoma and validation by next-generation sequencing.

BACKGROUND: Mutations in four major driver genes -KRAS, CDKN2A, TP53, and SMAD4- are central to the pathogenesis of pancreatic ductal adenocarcinoma (PDAC) and critically inform diagnosis, therapeutic decision-making, and prognostic assessment. Although next-generation sequencing (NGS) is widely regarded as the gold standard for detecting these mutations, its clinical application is often limited by suboptimal analytical efficiency and substantial economic cost. Among these genes, immunohistochemical (IHC) staining for the proteins encoded by TP53 and SMAD4 has been extensively adopted in routine pathology practice. However, standardized IHC pattern classification schemes and rigorous validation of their predictive accuracy for underlying genomic alterations remain lacking in PDAC. METHODS: We retrospectively enrolled 63 PDAC patients and systematically characterized the typical IHC expression patterns of p53 and Smad4. Targeted NGS was subsequently performed on all available tumor specimens, and the resulting mutational profiles were correlated with corresponding IHC findings. Diagnostic performance including sensitivity, specificity and accuracy of p53 IHC for predicting TP53 mutations and of Smad4 IHC for predicting SMAD4 mutations was rigorously evaluated. RESULTS: Among the four canonical driver genes, co-occurring double- or triple-gene mutations were prevalent; within TP53 and SMAD4, missense mutations constituted the most frequent variant type. Using NGS as the reference standard, we validated the diagnostic utility of a three-tiered p53 IHC classification system, particularly in fine-needle biopsy (FNB) specimens. Furthermore, we proposed a novel, refined Smad4 IHC pattern classification that incorporates an "intermediate" category, thereby expanding upon conventional binary interpretation. This new scheme achieved markedly improved mutation prediction accuracy (0.76) compared with traditional approaches (0.57). CONCLUSION: Our study highlights the complementary diagnostic value of p53 and Smad4 IHC relative to molecular testing in PDAC, especially when tissue is limited, as commonly encountered in FNB specimens. The newly established Smad4 IHC classification system, which integrates an intermediate expression category into the conventional two-tier framework, demonstrates superior clinical utility and enhances predictive accuracy for SMAD4 genomic alterations.

Humans

Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.

BACKGROUND: Wearable sensors are a promising method for collecting clinical trial outcome data for people with Angelman syndrome (AS). However, there has yet to be a systematic probe into the ways in which wearable sensors have been successfully used in AS. The current study aims to provide a quantitative summary of wearable sensors used in AS, including contexts of use and psychometric properties, and to present key narrative highlights. METHOD: Literature searches were performed in three electronic databases: APA PsycInfo, PubMed and Web of Science Core Collection. Data items were categorized into four categories: sample characteristics, study methodological details, wearable sensor characteristics and psychometric properties assessed. Sample characteristics included sample size, age, biological sex, race/ethnicity and cognitive/developmental functioning. Study methodological details were subdivided into study design and setting. Wearable sensor characteristics included sensor type, placement site, means of attachment, assessed construct and sensor-related data loss. Psychometric properties assessed included reliability and validity of sensor-derived data. RESULTS: We identified 16 articles through our systematic review. Wearable sensors were used to study sleep (n&#x2009;=&#x2009;10, 62.5%), language (n&#x2009;=&#x2009;2, 12.5%), gait (n&#x2009;=&#x2009;2, 12.5%), caregiver proximity (n&#x2009;=&#x2009;1, 6.3%), EEG power (n = 1, 6.3%),&#xa0;and arousal (n&#x2009;=&#x2009;1, 6.3%) in AS through actigraphs, vocalization recorders, inertial sensors, radio-frequency identification watches, wireless EEG caps,&#xa0;and functional near-infrared spectroscopy caps, respectively. Findings from these studies broadly indicate that wearable sensors are feasible, reliable and valid for assessing a range of behaviours relevant to AS. CONCLUSIONS: Wearable sensors are a promising solution to enhance assessments in AS. However, with the small extant literature characterized by small sample sizes and restricted focus on a few relevant features in AS, there remains ample opportunities to explore the use of wearable sensors in people with AS. Additional studies will better inform clinical decision-making and ultimately improve the lives of people with AS and their families.

Humans

Effects of blood flow restriction training combined with plyometric training on lower limb muscle strength and motor unit recruitment in basketball players: An experimental study.

OBJECTIVE: Previous studies have shown that plyometric training (PT) improves neuromuscular function and explosive power but not maximal strength. Blood flow restriction training (BFR) combined with low-intensity resistance training (RT) increases muscle mass and strength. This study investigated the effects of PT, and BFR combined with PT on lower-limb muscle function. METHODS: Twenty elite basketball players were randomly assigned to two groups: PT-alone group (PT, n&#x202f;=&#x202f;10) and BFR combine with PT group (PT-BFR, n&#x202f;=&#x202f;10). All participants underwent bodyweight-based plyometric training three times per week for eight weeks. Peak torque values for hip and knee flexion and extension, as well as root mean square (RMS) values derived from electromyography, were measured before and after the intervention. RESULTS: After the 8-week intervention, both groups showed significant improvements in knee flexion and extension peak torque at 180&#xb0;/s (all p&#x202f;<&#x202f;0.01). Between-group comparisons revealed greater gains in the PT-BFR group for hip extension and flexion at 60&#xb0;/s (p&#x202f;=&#x202f;0.036-0.002; &#x3b7;p2 = 0.225-0.233). RMS of the rectus femoris increased significantly more in the PT-BFR group than in the PT group (right: p&#x2009;=&#x2009;0.004, &#x3b7;p2 = 0.385; left: p&#x2009;=&#x2009;0.020, &#x3b7;p2 = 0.266), whereas no significant changes were observed in the gastrocnemius, tibialis anterior, or biceps femoris (all p&#x2009;>&#x2009;0.05). CMJ height also improved more in the PT-BFR group, with a significant group &#xd7;&#x2009;time interaction (p&#x2009;=&#x2009;0.042, &#x3b7;p2 = 0.210). CONCLUSION: Both training protocols enhanced bilateral lower-limb strength, with notable gains in the non-dominant leg; however, the magnitude did not differ substantially between groups. In contrast, compared with PT alone, BFR combined with PT produced superior enhancements in lower-limb muscle strength and neuromuscular recruitment. These findings suggest that when PT is employed to improve explosive power, it may be effectively combined with BFR to further augment muscular strength.

Humans

Beyond predictive performance: A systematic review and critical methodological appraisal of AI/ML and conventional modelling strategies in breast, colorectal, and pancreatic Cancer.

BACKGROUND: Predictive modelling for cancer risk, treatment-related complications, and survival is central to precision oncology. Conventional logistic regression (LR) and Cox proportional hazards (CoxPH) regression remain widely used but are limited when modelling nonlinear interactions, high-dimensional imaging features, and multimodal clinical-metabolic predictors. Artificial intelligence (AI) and machine learning (ML) methods offer expanded capability through automated feature extraction, ensemble learning, and flexible survival modelling, but the evidence on when AI/ML adds value over conventional models across cancer sites and predictive tasks remains fragmented. OBJECTIVE: To systematically evaluate the methodological performance, validation strategies, and translational limitations of AI/ML models compared with conventional statistical models in published predictive-modelling studies for breast, colorectal, or pancreatic cancer. METHODS: PubMed, Scopus, and Web of Science were searched for studies published between January 2019 and March 2025. Two reviewers independently conducted title-and-abstract screening, full-text eligibility assessment, and PROBAST risk-of-bias assessment. Sixty-five studies (n&#xa0;=&#xa0;907,567 participants) were narratively synthesised by cancer site, predictive task, model family, comparator, validation strategy, predictor modality, and calibration or explainability reporting. RESULTS: The 65 studies comprised breast cancer (n&#xa0;=&#xa0;35), colorectal cancer (n&#xa0;=&#xa0;21), and pancreatic cancer (n&#xa0;=&#xa0;9). AI/ML superiority over LR and CoxPH was task- and data-dependent. CNN- and U-Net-based models predominated in imaging and body-composition tasks, tree-based ensembles consistently outperformed LR for tabular perioperative complication prediction, and CoxPH remained competitive, and in the largest pancreatic risk study, superior to XGBoost (C-index 0.802 vs 0.723) in well-structured datasets. PROBAST analysis-domain risk was moderate in 54 of 65 studies (83%), driven by limited external validation, sparse calibration reporting (11/65), and few decision-curve analyses (7/65). CONCLUSION: AI/ML adds the most methodological value in imaging-derived feature extraction and nonlinear perioperative prediction, while conventional regression remains preferable in large, structured datasets with linear predictors. Clinical translation requires standardised body-composition definitions, external validation, calibration assessment, decision-curve analysis, and explainability, in line with TRIPOD+AI and CLAIM standards.

Humans

Teach-Back in Clinical Communication: A Systematic Review and Meta-analysis.

BACKGROUND: Teach-back has been identified as a high-quality clinical communication strategy. Our aim was to synthesize current literature on teach-back effectiveness. METHODS: We searched MEDLINE, Embase, and CINAHL Complete databases to identify relevant studies published between 2018 and 2026. We also included pre-2018 studies identified in prior systematic reviews. Studies were eligible for inclusion if they involved adult patients and/or care partners, delivered teach-back in a single encounter, had a comparator group, and reported proximal/intermediate patient outcomes (as defined in our conceptual model). Two independent investigators screened each citation at the title/abstract and full-text levels and assessed risk of bias. Study characteristics and results were extracted. When meta-analysis was performed, we used standardized mean differences (SMD) to estimate summary effects. We assessed certainty of evidence (COE) using Grading of Recommendations Assessment, Development and Evaluation (GRADE) domains. RESULTS: Our systematic review included 18 randomized controlled trials (RCTs) involving 1985 participants. Across 9 RCTs assessing knowledge acquisition, conceptual inconsistencies precluded meta-analysis. Overall, there was no clear pattern of the effect of teach-back on knowledge (very low COE). In a meta-analysis of 5 RCTs assessing self-efficacy (416 participants), we found that teach-back interventions led to a large increase in self-efficacy relative to usual care (SMD&#x2009;=&#x2009;2.40; 95%CI 0.37-4.44) (very low COE). In a meta-analysis of 7 RCTs assessing adherence to health behaviors (571 participants), teach-back interventions led to a large increase in adherence (SMD&#x2009;=&#x2009;1.04; 95%CI 0.45-1.64) (low COE). Meta-analyses for both self-efficacy and adherence had large confidence intervals that ranged from small to large effect sizes and had substantial heterogeneity. DISCUSSION: In this systematic review and meta-analysis, we did not identify a clear benefit of teach-back on knowledge acquisition but did find evidence that teach-back improves self-efficacy and self-reported, short-term adherence to health behaviors.

clinical communication

Interactive gaming during inhalational induction of anesthesia reduces pediatric patient anxiety and improves induction compliance: A randomized controlled trial.

BACKGROUND: Preoperative anxiety affects up to 75% of pediatric surgical patients and is associated with adverse postoperative outcomes. Traditional anxiolytic strategies with premedication carry drawbacks including delayed recovery and paradoxical reactions, driving interest in non-pharmacologic alternatives. Audiovisual distraction represents one approach, encompassing passive methods (e.g. watching a video) and active modalities (e.g. interactive gaming). The Bedside Entertainment and Relaxation Theater (BERT) is a projection-based environment that enables audiovisual distraction during induction. Whether BERT-based interactive gaming reduces anxiety and improves induction compliance compared to standard perioperative care remains unknown. METHODS: This single-center RCT enrolled 74 pediatric patients aged 4 to 14 undergoing inhalational induction, randomized to standard care (SOC) or interactive gaming via BERT added to SOC during induction (BERT). The primary outcome was change in patient anxiety from baseline to induction, measured using the Modified Yale Preoperative Anxiety Scale (mYPAS). Secondary outcomes included caregiver anxiety, induction compliance, OR efficiency, opioid administration, and OR staff perceptions. RESULTS: Patients in the BERT group experienced significantly smaller increases in anxiety from baseline to induction than SOC (median mYPAS increase [IQR]: 0 [0 to 0] vs 10 [0 to 38], p&#xa0;<&#xa0;0.001). Induction compliance improved, with lower Induction Compliance Checklist (ICC) scores indicating fewer induction-related disruptive behaviors than SOC (median: 0 vs 1, shift -1 [95% CI: -2 to 0]; p&#xa0;=&#xa0;0.004). Caregiver anxiety increased less in the BERT group than SOC (mean STAI increase: 0.18 vs 1.89, difference&#xa0;-&#xa0;1.7, [95% CI: -3.2 to -0.26]; p&#xa0;=&#xa0;0.022). OR staff reported high acceptability, with 97% supporting continued use. No differences were observed in OR efficiency or opioid administration between groups. CONCLUSIONS: Interactive gaming via BERT attenuated increases in patient anxiety, improved induction compliance, and reduced the rise in caregiver anxiety without prolonging OR time. These findings support BERT as an effective, workflow-compatible anxiolytic strategy for pediatric inhalational induction.

Humans

Comparing the efficacy and safety of unilateral versus bilateral spinal anesthesia: a meta-analysis and systematic review.

BACKGROUND: Unilateral spinal anesthesia has gained increasing attention in recent years. Emerging evidence suggests that it provides comparable analgesia to conventional bilateral spinal anesthesia while reducing adverse effects, and its efficacy and safety compared to bilateral spinal anesthesia remains controversial. OBJECTIVE: This systematic review and meta-analysis aims to evaluate and compare the efficacy and safety of unilateral versus bilateral spinal anesthesia. DESIGN: Systematic reviews and meta-analysis of randomized controlled trials (RCTs). DATA SOURCES: A systematic search was conducted across PubMed, EMBASE, and Cochrane Library from inception to December 10, 2024. ELIGIBILITY CRITERIA: Included studies were randomized controlled trials involving adult patients (&#x2265;18&#x2009;years) undergoing surgery under spinal anesthesia, comparing unilateral versus bilateral spinal anesthesia for efficacy and adverse effects. Studies that focused exclusively on either unilateral or bilateral spinal anesthesia were excluded. The comparator group used the same local anesthetic as the experimental group, with no restrictions on adjuncts (e.g. fentanyl, morphine). RESULTS: Nineteen randomized controlled trials including 1191 patients met the inclusion criteria. Compared with bilateral spinal anesthesia, unilateral spinal anesthesia has a longer onset of sensory blockade (MD = 2.58, 95% CI: 0.93 to 4.22, p&#x2009;=&#x2009;0.002), a shorter duration of sensory blockade (MD&#x2009;=&#x2009;-27.83, 95% CI: -39.25 to -16.42, p&#x2009;<&#x2009;0.00001). In addition, unilateral spinal anesthesia significantly reduced the incidence of hypotension (RR = 0.40, 95% CI: 0.31 to 0.52, p&#x2009;<&#x2009;0.0001), nausea and vomiting (RR = 0.20, 95% CI: 0.07 to 0.56, p&#x2009;=&#x2009;0.002), and post-dural puncture headache (RR = 0.44, 95% CI: 0.23 to 0.81, p&#x2009;=&#x2009;0.009). No statistically significant differences were observed in bradycardia and urinary retention. Collectively, these findings support unilateral spinal anesthesia as a strategy that may enhance perioperative safety while maintaining adequate anesthetic efficacy in appropriately selected patients. CONCLUSIONS: Unilateral spinal anesthesia may offer a favorable balance between anesthetic efficacy and safety compared with bilateral spinal anesthesia, although its clinical utility may depend on surgical duration and patient characteristics.

Humans

The Effects of Intermittent Hypoxic Training Strategies on Maximal Oxygen Uptake in Healthy Humans: A Meta-analysis with Meta-regression.

BACKGROUND: Intermittent hypoxic training aims to enhance exercise performance and health, commonly assessed through maximal oxygen uptake (VO2max). Currently applied methods are live-high train-low (LHTL), live-low train-high (LLTH) and passive hypoxic conditioning (PHC). However, within these methods, numerous modes of application exist, and effectiveness is debated. OBJECTIVE: To determine the effect of LHTL, LLTH and PHC on VO2max in healthy participants, and identify factors associated with the amplitude of change in VO2max. METHODS: We conducted a systematic review with random-effects meta-analysis and meta-regression. Studies were identified through PubMed, EMBASE and Web of Science. We included controlled studies, calculating between-group standardised mean differences. Athlete and non-athlete populations were analysed separately. RoB2 was used to assess study quality and publication bias was investigated with funnel plots and the Egger's test. RESULTS: Of the 5244 identified studies, 62 were included for analysis, resulting in a sample size of 1332 participants (610 athletes, 722 non-athletes). LHTL increased VO2max significantly more than control in athletes (mean difference [MD]&#x2009;=&#x2009;2.17; 95% CI&#x2009;=&#x2009;0.77, 3.56) but not in non-athletes (MD&#x2009;=&#x2009;3.1; 95% CI&#x2009;=&#x2009;&#x2009;-&#x2009;0.23, 6.43). LLTH did not increase VO2max significantly more than control in athletes (MD&#x2009;=&#x2009;0.89; 95% CI&#x2009;=&#x2009;&#x2009;-&#x2009;0.27, 2.05) but it did in non-athletes (MD&#x2009;=&#x2009;1.70; 95% CI&#x2009;=&#x2009;0.85, 2.54). PHC did not increase VO2max significantly more than control in athletes (MD&#x2009;=&#x2009;&#x2009;-&#x2009;1.07; 95% CI&#x2009;=&#x2009;&#x2009;-&#x2009;3.51, 1.37) but it did in non-athletes (MD&#x2009;=&#x2009;2.26; 95% CI&#x2009;=&#x2009;1.00, 3.52). Multivariate meta-regressions identified the severity, duration, and frequency of hypoxic exposure to be significantly associated with the change in VO2max. CONCLUSIONS: LHTL showed a significant effect on VO2max in athletic populations while LLTH and PHC showed a significant effect on VO2max in non-athletic populations only. Future studies should target investigating which characteristics (e.g. severity, duration) of the hypoxic exposure are most beneficial.

Journal Article

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC&#x2009;=&#x2009;0.91-0.92 [0.83-0.97]; k&#x2009;=&#x2009;55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC&#x2009;=&#x2009;0.90-0.91 [0.85-0.95] (k&#x2009;=&#x2009;228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs&#x2009;=&#x2009;0.90 [0.83-0.94] (k&#x2009;=&#x2009;124) and ICC&#x2009;=&#x2009;0.91 [0.72-0.98] (k&#x2009;=&#x2009;9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load&#x2013;velocity relationship

Clinical performance evaluation of single-shade versus multi-shade composite resins in non-carious cervical lesions: a 36-month randomized clinical trial.

BACKGROUND: Composite resins are widely used as the material of choice for definitive restorations due to their ability to integrate functional and aesthetic aspects in dental rehabilitation. Recently, one-shade composite resins have been introduced to simplify the clinical workflow. OBJECTIVES: This study aimed to compare the clinical performance of a "chameleon effect" composite resin with that of a multi-shade composite resin in non-carious cervical lesions after 36 months of follow-up. METHODS: This study was a randomized, controlled, double-blind clinical trial with an equivalence design using a split-mouth approach. The sample consisted of 60 patients presenting at least two non-carious cervical lesions, totaling 120 restorations. Restorations were performed using two materials from the same commercial brand: Vittra Unique (one-shade group) and Vittra APS (multi-shade group). The clinical performance of the restorations was longitudinally evaluated according to the FDI criteria. Survival analysis was performed using Kaplan-Meier curves and the log-rank test, while other clinical parameters were compared using the chi-square test (&#x3b1; = 0.05). RESULTS: At baseline, no statistically significant differences were observed between the groups regarding the evaluated biological, functional, and aesthetic parameters (p > 0.05). Both materials demonstrated clinically acceptable performance according to the FDI criteria, with no significant differences between them. CONCLUSIONS: After 36 months, no significant differences were observed between the one-shade and the multi-shade composite resins in the restoration of non-carious cervical lesions. CLINICAL SIGNIFICANCE: This 36-month randomized clinical trial demonstrates that single-shade composite resins achieve structural durability and aesthetic integration equivalent to traditional multi-shade layering when restoring non-carious cervical lesions. This evidence validates a simplified, single-shade restorative workflow, significantly reducing chairside time and operator-dependent variables without compromising the clinical longevity.

Humans

Comparative effectiveness of percutaneous coronary intervention strategies for coronary small-vessel disease: a network meta-analysis of randomized trials.

BACKGROUND: Coronary small-vessel disease (SVD) remains challenging for percutaneous coronary intervention (PCI) because small lumens magnify restenosis and ischemic risk. Multiple devices are available, yet their comparative performance is uncertain. This study evaluated and ranked PCI strategies for SVD. METHODS: A systematic review and network meta-analysis was conducted in accordance with PRISMA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar were searched from inception to 15 August 2025. Eligible studies were English-language randomized controlled trials enrolling adults with angiographic SVD defined as reference vessel diameter &#x2264;3.0&#x2009;mm, comparing PCI strategies, and reporting target lesion revascularization (TLR), binary restenosis (BR), or myocardial infarction (MI). A frequentist random-effects network meta-analysis generated odds ratios (ORs) with 95% confidence intervals (CIs) and treatment rankings using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirty-nine trials including 14,503 patients met the criteria. For TLR (37 studies; 11,980 patients), the highest SUCRA values were observed with sirolimus-eluting stents (SES 90.1%), zotarolimus-eluting stents (ZES 83.9%), and everolimus-eluting stents (EES 82.2%). For BR (32; 6,468), SES, ZES, and paclitaxel-coated balloons (DCB-PTX) ranked highest (95.0%, 80.0%, and 78.3%). For MI (37; 11,602), SES, DCB-PTX, and ZES ranked highest (79.0%, 78.7%, and 68.5%). Representative effects showed SES reduced TLR versus bare-metal stents (BMS) (OR, 0.25; 95% CI, 0.15-0.43) and MI versus BMS (OR, 0.41; 95% CI, 0.21-0.79). Conventional approaches such as BMS, plain old balloon angioplasty (POBA), and gold-plated balloon angioplasty (GPBA) ranked lowest across outcomes. CONCLUSION: SES provides the most consistent clinical benefit for coronary SVD. ZES, EES, and DCB-PTX are effective alternatives in selected settings, whereas BMS, POBA, and GPBA are less effective. These findings offer comparative evidence to guide device selection in SVD.

Humans

Long-term microbiome and clinical effects of a microbiome-guided personalized diet versus low-FODMAP diet in irritable bowel syndrome: A 12-month follow-up randomized controlled trial.

Dietary therapy is central to irritable bowel syndrome (IBS) management, yet the long-term durability of the low-FODMAP diet (LFD), and of microbiome-guided personalization, remains unclear. We assessed the long-term clinical and gut-microbiome effects of a microbiome-guided personalized diet (PD) compared with a standard LFD in adults meeting Rome IV criteria for IBS. In this multicenter, open-label randomized controlled trial with blinded outcome assessment, participants who completed a 6-week dietary intervention (PD or LFD) were followed at 6 and 12 months without further dietary intervention. Outcomes included the IBS Severity Scoring System (IBS-SSS), IBS Quality of Life (IBS-QOL), and the Hospital Anxiety and Depression Scale (HADS); gut microbiota were profiled by 16S rRNA sequencing. Longitudinal changes were evaluated using linear mixed-effects models, responder analyses, PERMANOVA, and PERMDISP. Both diets reduced IBS-SSS at 6 weeks. PD maintained symptom improvement at 6 and 12 months (-82.0 and -78.3 points from baseline), whereas LFD benefits regressed by 12 months (+29.3 points; between-group p&#x2009;=&#x2009;0.001). At 12 months, IBS-SSS responder rates were higher with PD than LFD (62.5% vs 34.5%; absolute risk difference&#x2009;+28.0%, 95% CI 4.2-47.7; Fisher p&#x2009;=&#x2009;0.029), and IBS-QOL, HADS-anxiety, and HADS-depression showed more favourable trajectories with PD. PD was associated with sustained Shannon alpha-diversity gains (+0.488 at 6 weeks;&#x2009;+0.205 at 12 months; both p&#x2009;<&#x2009;0.01). A modest between-group beta-diversity difference at 6 months (R2&#x2009;=&#x2009;0.035; p&#x2009;=&#x2009;0.011) was not significant at 12 months. This hypothesis-generating follow-up suggests more durable benefit with PD; larger trials powered for long-term clinical and microbiome outcomes are warranted.

Humans

Volumetric bone marrow cellularity (VBMC) assessment from routinely processed trephines using three-dimensional x-ray histology and gaussian peak modelling.

Objective.Bone marrow cellularity is routinely estimated from a small number of two-dimensional histology sections, making assessment sensitive to section representativeness, processing artefacts and observer interpretation. Three-dimensional (3D) x-ray histology (XRH), using x-ray computed microtomography (&#xb5;CT), enables non-destructive whole-block imaging of trephine biopsies. This study evaluated whether XRH combined with Gaussian peak modelling could provide a pragmatic whole-block volumetric bone marrow cellularity (VBMC) estimate from formalin-fixed paraffin-embedded (FFPE) trephine biopsy blocks.Approach.Six routinely processed FFPE bone marrow trephine blocks were imaged using &#xb5;CT-based XRH at &#x223c;15 &#xb5;m spatial resolution. VBMC was defined as the red-marrow (RM) fraction of the marrow soft-tissue compartment, RM/(RM + intra-biopsy wax), with wax serving as the volumetric proxy for adipocyte/yellow marrow space. Whole-volume greyscale histograms were modelled using a three-peak Gaussian approach representing intra-biopsy wax, RM and demineralised trabecular matrix. Peak-height and area-under-the-curve metrics were compared with whole-volume 3D segmentation and clinical two-dimensional (2D) cellularity estimates.Main Results.Gaussian peak modelling successfully approximated the segmented tissue-phase distributions. The peak-height-derived VBMC metric showed the closest agreement with whole-volume 3D segmentation, with an average absolute percentage difference of 9.3%, compared with 18.6% for clinical expert 2D cellularity estimates. The area-under-the-curve metric followed similar trends but consistently overestimated VBMC. Clinical 2D cellularity broadly followed whole-biopsy trends but showed one discordant case not explained by slice-position sampling alone. XRH also enabled unrestricted virtual reslicing and visualisation of sectioning-associated artefacts prior to further microtomy.Significance.Pre-sectioning XRH combined with Gaussian peak modelling provides a rapid, segmentation-free route to volumetric cellularity estimation from intact clinical FFPE trephine blocks. The approach supports objective whole-biopsy assessment while remaining compatible with routine histopathology workflows, reflecting the expected limitations of section-based visual estimation despite its role as the current clinical standard. In the near term, it could provide a non-disruptive adjunct to conventional 2D cellularity reporting, pending larger validation studies.

Imaging, Three-Dimensional

A systematic review and network meta-analysis of single nucleotide polymorphisms associated with oral submucous fibrosis risk.

BACKGROUND: Oral submucous fibrosis (OSF) is a chronic and insidious oral disease characterized by hyalinization of the subepithelial connective tissue and progressive fibrosis of the oral submucosa. It is a precancerous condition of oral squamous cell carcinoma. Studies have demonstrated that single nucleotide polymorphisms (SNPs) are closely associated with susceptibility to OSF. This study aims to comprehensively evaluate the association between SNPs and OSF risk and to rank the strength of the association between different genetic models and OSF susceptibility. METHODS: Literature related to OSF was comprehensively searched from PubMed, Web of Science, Embase, Cochrane Library, CNKI, and Wangfang databases up to July 2025. Full-text case-control studies with patients diagnosed with OSF were included. Quality assessment was performed to evaluate the risk of bias. RevMan 5.4, GeMTC 0.14.3, and STATA 17.0 were used for the pairwise and Bayesian network meta-analysis. RESULTS: A total of 24 studies with 2545 cases and 3772 controls, covering 13 SNPs in 11 genes, were included in our meta-analysis. We found that CYP1A1 rs4646903:T>C, CYP1A1 rs1048943:A>G, GSTT1 null genotype, GSTM1 null genotype, and XRCC3 rs861539:C>T were associated with an increased risk of OSF, while MMP2 rs243865:C>T and MMP3 rs3025058: 5A>6A were associated with a decreased risk of OSF. Further Bayesian network meta-analysis indicated the top 5 genetic models with the highest association with OSF risk in network group 1 were the dominant model, homozygous model, allelic model, and recessive model of CYP1A1 rs1048943:A>G (ranked 1-4), and the heterozygous/dominant model of CYP1A1 rs4646903:T>C (both ranked 5). While the allelic models of XRCC3 rs861539:C>T and MMP3 rs3025058: 5A>6A ranked first for predicting OSF in group 2 and group 3, respectively. CONCLUSION: Some specific SNPs are significantly related to the risk of OSF. Among them, the dominant model of CYP1A1 rs1048943:A>G may be the most strongly associated genetic model with OSF risk. Future large-sample, well-designed studies with detailed genotype data are needed to validate the roles of these SNPs in OSF risk.

Humans

Closed-loop vasopressor systems for hemodynamic control in perioperative and critical care settings: a systematic review and meta-analysis.

Maintaining mean arterial pressure (MAP) within a predefined target is central to haemodynamic management in surgical and critically ill adults receiving vasopressors. Closed-loop vasopressor (CLV) systems automate titration to optimise blood pressure control, but their clinical effectiveness remains uncertain. We performed a systematic review and meta-analysis comparing CLV with manual titration. This PRISMA 2020-compliant review was prospectively registered in PROSPERO (CRD420250655697). MEDLINE, Embase, Scopus, Web of Science, CENTRAL, and the Cochrane Library were searched (January 2000-June 2025). Randomised controlled trials enrolling adults receiving vasopressors in perioperative or intensive care settings were included. Primary outcomes were time within the MAP target range and time spent in hypotension or hypertension. Risk of bias was assessed using RoB 2.0 and certainty of evidence using GRADE. Random- or fixed-effects models were selected according to heterogeneity. Six randomized controlled trials (215 patients) were included in the systematic review, whereas five perioperative trials contributed to the meta-analysis of haemodynamic control outcomes, and one ICU-based study was summarized narratively because it did not report comparable MAP control endpoints. CLV increased time within the MAP target range (mean difference [MD] 33.94%, 95% CI 20.41-47.46; I2&#x2009;=&#x2009;77%) and reduced time in hypotension (MD&#x2009;-&#x2009;18.24%, 95% CI&#x2009;-&#x2009;28.95 to&#x2009;-&#x2009;7.53; I2&#x2009;=&#x2009;73%). There was no significant difference in time in hypertension, cumulative norepinephrine dose, or major/minor adverse events. ICU length of stay was not pooled because of clinical and methodological heterogeneity. Certainty of evidence ranged from low to high (moderate for haemodynamic control outcomes). CLV systems improved haemodynamic control, primarily in perioperative settings,&#xa0;but heterogeneity and small samples limit confidence in effect size and generalisability.&#xa0;Evidence in critically ill populations remains limited, and larger trials are needed to determine whether improvements in these physiological surrogate endpoints translate into meaningful patient-centred outcomes.

Humans

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans