The effects of extracorporeal shock wave lithotripsy on pacemaker function.

Twenty-two pacemaker pulse generators were exposed to shock waves of an extracorporeal shock wave lithotripter to assess the effects of the extremely high pressure transients on pacemaker function. The pulse generator and distal aspect of the lead were positioned 5 cm from the focal point of the lithotripter and 10 cm from each other. Pulse generator function was analyzed during shock wave delivery synchronized with pulse generator output, during shock waves at a rate faster than the escape rate, and after exposure to lithotripsy. During shock waves delivered synchronously with pulse generator output, only one of 22 pulse generators malfunctioned by intermittently reverting to the magnet rate. When subjected to shock waves at a rate greater than the escape rate, 50% of the pulse generators were inhibited by electromechanical interference from the lithotripter. Both bipolar and unipolar devices were affected. However, analysis after exposure to shock waves showed that none of the pacemakers was damaged or spuriously reprogrammed. In conclusion, cardiac pacemakers do not appear to be damaged or reprogrammed by exposure to extracorporeal shock wave lithotripsy. The likelihood of false inhibition appears to be very low if shock waves are delivered synchronously with the QRS.

Equipment Failure↗

Automatic implantable defibrillator discharge resulting from routine pacemaker programming.

A middle-aged gentleman with an idiopathic dilated cardiomyopathy, drug-refractory sustained ventricular arrhythmia, and high-degree AV block was managed with an automatic implantable cardioverter-defibrillator (AICD) and a Cordis Multicor II VVI pacemaker. During a routine follow-up visit, the pacemaker threshold was determined. Seven seconds after reprogramming the Cordis pacemaker to the "stat" VVI mode, the AICD discharged. The time to discharge after reprogramming the pacemaker equalled the previously determined AICD charge time. No other rhythm disturbance was documented and the rate with double counting of pacemaker stimulus and QRS complex was less than the triggering rate for the AICD. In conclusion, the AICD can be triggered by pacemaker programming signals unrelated to subsequent pacemaker function.

Electric Countershock↗

Effects of extracorporeal shock wave lithotripsy on cardiac pacemakers and its safety in patients with implanted cardiac pacemakers.

UNLABELLED: Effects of extracorporeal shock wave lithotripsy (ESWL) were studied on 15 pacemakers (standard single chamber n = 5, dual chamber n = 6, rate responsive single chamber [Activitrax] n = 4). In-vitro testing involved suspending the pacemakers in a bath of degassified, deionized water firmly taped to a platform at the point of maximal pressure, i.e., second focal point (F2), where they received pressure shocks (means = 1300) from the HM3 Dornier lithotriptor. The pacemakers, programmed to their most sensitive setting, were continuously pacing at nominal outputs (atrial and ventricular pacing in the DDD mode). All units were assessed by a pacing system analyzer before and after the study, then underwent destructive analysis. During standard single chamber pacing (VVI) the pacing stimulus triggered ESWL. For dual chamber devices, ESWL was triggered by the atrial paced event which induced inhibition of the ventricular output in two pacemaker. This was eliminated by reprogramming to a less sensitive setting. The pacemaker can, hermetic seal and internal circuitry were undamaged in all units. Two rate responsive single chamber pacemakers had their activity sensing piezoelectric elements shattered when placed at F2. Two other units placed 5 cm from F2 were stimulated to their maximum upper programmed pacing rate with ESWL therapy, but were otherwise unaffected. Subsequent to this study, six patients with pacemakers programmed to the VVI (five), DDD (one) modes implanted in the thorax underwent successful ESWL without pacemaker or arrhythmic event. CONCLUSIONS: (A) It is generally safe for patients implanted with standard single chamber devices in a ventricular application to undergo ESWL without modifying the pacing/sensing parameters. (B) Patients implanted with dual chamber devices who pace in the atrium should be reprogrammed to the VVI mode during ESWL. (C) Patients with piezoelectric activity sensing rate responsive single chamber pacemakers should have this feature programmed off during ESWL and, if implanted in the abdomen, probably should not undergo ESWL.

Aged↗

A new algorithm for a high level of protection against pacemaker-mediated tachycardia.

Pacemaker-mediated tachycardia (PMT) is a well-known complication of DDD pacing. PMT needs a permeable V-A conduction and is usually initiated by a premature ventricular or atrial systole, artifact sensing, or misprogramming (long AV delay [AVD]). Today, protection against PMT is expected from pacemaker multiprogrammability. Unfortunately, this prevention is often ineffective; postventricular atrial refractory period (PVARP) must be prolonged, which limits the upper tracking rate and the patient capacity. The new Chorus ELA Medical DDD pacemaker provides classic protection against PMT (PVARP prolongation after premature V or A complex, magnet application, noise sensing), but also automatically reduces an eventual PMT and adjusts AVD or PVARP for a high level of protection. The process is divided in four steps: (1) a sensing step for 16 cycles, with V-P conduction analysis; (2) confirmation of the presence of the PMT and analysis of V-A conduction time; (3) a termination step, by extending the PVARP after the following ventricular heart beat; and (4) in case of immediate recurrence of the tachycardia, reprogramming of the AVD and eventually of the PVARP. By first reducing AVD, before reprogramming PVARP, the pacemaker preserves point 2:1, providing a higher exercise capacity. This algorithm was successfully tested in three patients who had a permeable V-A conduction, without any adverse effect.

Algorithms↗

DDD pacemakers maximize hemodynamic benefits and minimize complications for most patients.

A 44-month retrospective analysis was performed on 666 pacemakers implanted at Mt. Sinai Medical Center. Mapping techniques and endocardial waveform analyses were used during lead positioning to ensure the best electrical environment. The optimal pacing lead type was selected based on the clinical situation. Follow-up evaluations were rigorous. Patient population ranged in age from 28 to 103 with a mean of 78 years at time of implant. Seventy percent of the patients received DDD pacemakers with an 81% survival incidence at 44 months. Of the VVI population (30% of the implants), there was a 62% survival incidence. Most problems associated with the pacing systems were related to the atrial channel. Loss of atrial sensing occurred in 7.5% of the population and was corrected noninvasively in 5.8%. Due to chronic loss of atrial sensing, 1.7% of the population remained programmed to DVI/VVI. A total of 7.7% were chronically reprogrammed from DDD to VVI, 5.6% secondary to atrial fibrillation. Reoperations were necessary in 1.2% of the malfunctioning systems that could not be corrected by reprogramming. The following conclusions were reached: (1) maximizing hemodynamic benefits and minimizing pacemaker complications permitted a survival rate equal to or better than that of the general population, and (2) chronic problems related to the atrial lead and malfunctions of the pacing system were minimized by careful patient selection, appropriate pacemaker and lead selection, endocardial waveform analysis, and thorough follow-up.

Adult↗

Long-term pacing in heart transplant recipients is usually unnecessary.

The indications for and timing of permanent pacing were reviewed in all 17 of 154 adult heart transplant recipients at this center who have had permanent pacemakers implanted. Resting 12-lead ECGs recorded during routine follow-up were examined. A prospective study of pacing requirement was then undertaken. Holter monitoring was performed before and after reprogramming the pacemakers to VVI mode at 50 beats/min. Exercise responses in various pacing modes were then assessed in seven patients with rate responsive pacemakers using a standard Bruce protocol treadmill test. The indication for pacing was sinus node dysfunction in 59% (10/17) and atrioventricular (AV) block in 41% (7/17). The majority of pacemakers were implanted between seven and 21 days after transplantation. There was a progressive reduction in the frequency of pacing on 12-lead ECGs with time after transplantation. There was a progressive reduction in the frequency of pacing on 12-lead ECGs with time after transplantation. Eight of 14 patients with empirically selected programming paced during Holter monitoring. After reprogramming to 50 beats/min VVI mode only three of 14 patients, all with sinus node dysfunction, paced. Rate responsive pacing made no difference to exercise time. The requirement for long-term pacing in cardiac transplant recipients is small (3/154) and is limited to patients with sinus node dysfunction. Rate responsive pacing did not increase exercise tolerance.

Adult↗

DDI pacing: indications, expectations, and follow-up.

The DDI mode of pacing that permits noncompetitive atrioventricular sequential bradycardia support was chosen in 65 of 480 (14%) patients selected for dual chamber pacing between February 1985 and March 1990. All patients were implanted with Pacesetter 283 or 285 pulse generators and programmed to DDI. The indications for pacing were sick sinus syndrome (n = 52), combined sinus node dysfunction and AV block (n = 13). Forty-two of these patients had a history of paroxysmal atrial arrhythmias. All patients received passive fixation atrial and ventricular leads. Follow-up thereafter was performed predischarge, and at 6 weeks, 3 and 6 months after discharge. The duration of follow-up ranged from 1-61 months (mean 31 months). Fifty-four of 65 (83%) patients chosen for DDI remain programmed in the DDI mode. Three patients were reprogrammed to VVI and eight to DDD. During the course of follow-up, six patients presented with effective VVI pacing with consistent ventriculoatrial conduction that was appropriately sensed by the atrial circuit with atrial output inhibition. A further four patients presented with "functional undersensing" due to ventricular blanking period (VBP) characteristics in these pulse generators and in this mode. Functional undersensing was eliminated in all but one patient by reprogramming the VBP to 13 msec with no subsequent episodes of provoked crosstalk inhibition. Effective VVI pacing was observed in patients with AV block during times of sinus acceleration.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Long-term stability of P wave sensing in single lead VDDR pacing: clinical versus subclinical atrial undersensing.

Optimal function of a single lead P wave synchronous rate adaptive ventricular pacing system (VDDR) requires reliable P wave sensing over time and during daily activities. The stability of P wave sensing and the incidence of sensitivity reprogramming in a single pass lead with a diagonally arranged bipole was assessed in 30 patients with complete atrioventricular block over a follow-up period of 12 +/- 1 months (range 6 months to 3 years). Atrial sensing was assessed during clinic visits, by physical maneuvers (postural changes, breathing, Valsalva maneuver, walking and isometric exercise), maximum treadmill exercise and Holter recordings. P wave amplitude at implantation was 1.21 +/- 0.09 (0.5-3.6) mV, and the atrial sensing threshold remained stable over the entire period of follow-up. Using an atrial sensitivity based on twice the sensing threshold at 1 month, P wave undersensing was found in 2, 4, 3, and 7 patients during clinic visit, physical maneuvers, exercise, and Holter recordings, respectively. Atrial sensitivity reprogramming was performed in three patients based on the correction of undersensing during physical maneuvers. Although eight patients had atrial undersensing on Holter recordings, the number of undersensed P waves was small (total 101 beats or 0.013% +/- 0.001% of total ventricular beats) and no patient was symptomatic. One patient had intermittent atrial undersensing at the highest sensitivity, but the VDDR mode was still functional most of the time. No patient had myopotential interference at the programmed sensitivity. One patient developed chronic atrial fibrillation and was programmed to the VVIR mode. Thus, single lead VDDR pacing is a stable pacing mode in 97% of patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Atrial fibrillation and anticoagulation in patients with permanent pacemakers: implications for stroke prevention.

Several large prospective randomized trials have demonstrated that anticoagulation with warfarin reduces the risk of thromboembolic stroke in high risk patients with chronic AF by approximately 70%. Large numbers of patients with permanent pacemakers have AF, and anticoagulation rates in this population have not been described. In a prospective analysis of 110 consecutive patients attending the pacemaker clinic of a large university hospital we assessed the number of patients with AF and the proportion of these patients who were receiving anticoagulation to prevent thromboembolic stroke. Where necessary, temporary pacemaker reprogramming to low ventricular rates was utilized to facilitate the diagnosis of AF. Fifty-three of the 110 patients (48%) were diagnosed with AF, all of whom (100%) had accepted high risk factors for thromboembolic stroke. Only eight of the 53 (15%) had been anticoagulated with warfarin. Thirty-six of the 53 patients (68%) diagnosed with AF had no prior documented diagnosis of chronic AF, and the majority had no symptoms suggesting AF. A single lead II ECG was insufficient in 67 of the 110 patients (61%) to diagnose the underlying atrial rhythm; the remainder required 12-lead ECGs or temporary pacemaker reprogramming to low ventricular rates to diagnose the underlying atrial rhythm. AF is common in patients with permanent pacemakers. It is commonly asymptomatic, and anticoagulation is markedly underutilized in reducing stroke risk in these patients. Attention to the possibility of AF in paced patients should allow prompt diagnosis and allow both the initiation of anticoagulation in order to reduce thromboembolic stroke risk and consideration for cardioversion of AF to sinus rhythm.

Aged↗

Long-term survival of VDD pacing.

UNLABELLED: All patients with VDD systems implanted at a tertiary pacing center were identified from a computer database and data collected on pacing indications, follow-up duration, rate response, reasons for programming changes, and implant P wave amplitudes. RESULTS: 366 implants were identified for which complete data were available for 335 leads implanted in 316 patients. The mean follow-up period was 24.1 months, and age at implant was 73.5 +/- 11.8 years. During follow-up, 19 patients died (6%) and 62 (19.6%) were followed elsewhere. Indications for pacing were complete heart block, 56.6%; intermittent AV block, 21.8%; postablation complete heart block, 5.4%; 2:1 AV block, 13%; and others, 3.2%. Two groups: no mode change (NMC, n = 280) and mode change (MC, n = 36) were identified. Reasons for reprogramming in the MC group were as follows: atrial sensing, 11; AF/atrial flutter, 18; chronotropic incompetence, 3; and others 4. Significantly more MC patients had rate response programmed ON (44.4% vs 22.1%, P < 0.05). No significant differences between the two groups were found in other variables, including male gender (55.5% vs 54.6%), length of follow-up (27.1 +/- 17.8 vs 23.8 +/- 20.6 months), age at last follow-up (72 +/- 12.3 vs 75.9 +/- 11.9 years), and P wave amplitude (1.7 +/- 0.9 vs 1.8 +/- 0.9 mV). CONCLUSION: Reprogramming of VDD systems is infrequent. When necessary, it is usually prompted by atrial arrhythmias or failure of atrial sensing. When adequate atrial chronotropy has been verified, VDD is an acceptable alternative to DDD pacing and survives well over the long term.

Aged↗

Late retesting of system performance in ICD patients without spontaneous shocks.

UNLABELLED: One hundred five implantable cardioverter defibrillator (ICD) patients (71 +/- 9 years of age, 83% men) without spontaneous ICD discharges for > or = 12 months were tested to assess high voltage (HV) circuit integrity and the system's ability to recognize and terminate ventricular fibrillation (VF). Indications for ICD implantation were sustained ventricular tachycardia (VT) (35%), cardiac arrest (27%), and inducible VT (38%). Eighty-two percent of the patients had coronary artery disease (CAD), and the mean left ventricular ejection fraction (LVEF) was 36% +/- 13%. RESULTS: One hundred patients had inducible VF and five did not. Testing led to ICD reprogramming in 50 (49%) patients. Two (1.9%) patients required ICD replacement: (1) a 45-year-old patient with a Ventritex 110 ICD implanted for 13 months interfaced with a CPI 0062 lead implanted for 46 months could not be defibrillated internally (impedance nonmeasurable); (2) an 82-year-old patient with a 23-month-old Medtronic 7219 ICD interfaced with 6936 and 6933 leads whose defibrillation threshold (DFT) had doubled since implantation (24 J from 12 J). Lead fractures were found in both cases (proximal coil of the 0062, and subcutaneously in the 6933). Based on DFT determinations, the first shock output was programmed lower in 37 patients and higher in 10 patients. Shock pulse width was changed in one patient and the ventricular refractory period in another. No programming changes were made in 54 (51%) patients. CONCLUSIONS: (1) Late testing of HV circuit integrity in ICD patients without an ICD shock in > or = 12 months identifies previously unsuspected HV lead fractures; (2) chronic DFT testing resulted in HV output reprogramming in one-half of the patients.

Adult↗

Low-dose lipopolysaccharide (LPS) pretreatment of mouse macrophages modulates LPS-dependent interleukin-6 production in vitro.

Lipopolysaccharide (LPS) can induce mouse macrophages to produce a number of cytokines and other inflammatory mediators. Our laboratory previously reported that LPS-dependent macrophage-derived tumor necrosis factor alpha (TNF-alpha) production could be significantly potentiated by pretreatment with LPS at substimulatory LPS priming doses. The observed potentiation was shown to be coincident with a down-regulation of LPS-dependent nitric oxide (NO) production (X. Zhang and D. C. Morrison, J. Exp. Med. 177: 511-516, 1993). In order to determine whether these LPS reprogramming effects in mouse macrophages were selective for these two macrophage-derived mediators, we have examined the effects of LPS pretreatment on LPS-dependent interleukin 6 (IL-6) production. Thioglycolate-elicited mouse peritoneal macrophages were pretreated with various subthreshold stimulatory concentrations of LPS for 6 h, washed three times, and then stimulated with an effective stimulatory concentration of smooth LPS for 18 h. In confirmation of earlier studies, pretreatment of mouse macrophages with substimulatory doses of LPS inhibited the subsequent LPS-dependent NO production. This down-regulation was accompanied by a coordinate up-regulation of LPS-dependent IL-6 production, similar to what was shown earlier for TNF-alpha production. These priming effects with the substimulatory dose of smooth LPS are shown to be independent of doses of LPS used for subsequent activation and are not restricted to specific LPS stimulation. Moreover, the enhancement of the IL-6 response by LPS pretreatment is still observed in the presence of neutralizing antibody to TNF-alpha. These findings, therefore, provide further support for the conclusion that LPS-dependent macrophage reprogramming is likely to involve common regulatory pathways that control the secretion of both IL-6 and TNF-alpha.

Animals↗

Early complications of permanent pacemaker implantation: no difference between dual and single chamber systems.

OBJECTIVE: To evaluate the incidence of intraoperative and early postoperative complications (up to two months after implant) of endocardial permanent pacemaker insertion in all patients under-going a first implant at a referral centre. METHODS: Prospective evaluation of all endocardial pacemaker implantation procedures performed from April 1992 to January 1994 carried out by completion of standard audit form at implant. Patients' demographic data, medical history, details of pacemaker hardware used, and any complications were noted. Follow up information was also collected prospectively onto standard forms at pacemaker outpatient clinic. SETTING: United Kingdom tertiary referral cardiothoracic centre. PATIENTS: 1088 consecutive patients underwent implantation of their first endocardial permanent pacemaker from April 1992 to January 1994. Implant and follow up data were available for 1059 (97.3%) patients at analysis. The median (range) age was 77 years (16-99); 51.2 % were male. RESULTS: Dual chamber units were implanted in 54.1% of patients, single chamber atrial in 5.2%, and ventricular in 40.7%. A temporary pacing lead was present at implant in 22.9% of patients. Most (93.6%) implants were performed via the subclavian vein. Immediate complications were rare: eight (0.8%) patients developed pneumothorax requiring medical treatment and 11 (1.0%) an insignificant pneumothorax. There was no significant difference in the pneumothorax rate for dual chamber (DDD) compared with single chamber systems. Arterial puncture without sequelae was documented in 2.7% of attempts at subclavian vein cannulation. A total of 35 patients (3.3%) required reoperation; the reoperation rate for dual chamber (3.5%) was similar to that for single chamber (3.1%) systems. Electrode displacement (n = 15, 1.4%) was the most common reason for reoperation. Atrial lead displacement (n = 10, 1.6% of atrial leads) was significantly more common than ventricular lead displacement (n = 5, 0.5% of ventricular leads, P = 0.047). There was no difference in electrode displacement rates for dual (1.6%) compared with single (1.2%) chamber systems. Pacemaker pocket infection led to reoperation in 10 patients (six dual, four single chamber, P = not significant) and was significantly more common in patients who had a temporary pacing lead in place at implant (2.9%) than in those who did not (0.4%, P = 0.0014). Five patients (0.5%) required reoperation for generator erosion (two dual, three single chamber, P = not significant). and a further five for drainage of haematoma or a serous fluid collection (three dual, two single chamber, P = not significant). Complications that did not require reoperation were also rare. Undersensing occurred in 10 patients (0.9%). Atrial undersensing (n = 8) was significantly more common than ventricular undersensing (n = 2, P = 0.017). All patients were successfully treated by reprogramming of sensitivity. Superficial wound infection was treated successfully with antibiotics in nine patients (six dual, three single chamber, P = not significant). Three patients with DDD generators developed sustained atrial fibrillation: two required reprogramming to VVI mode and one required cardioversion. CONCLUSIONS: Permanent pacing in a large tertiary referral centre with experienced operators carries a low risk. Infection rates are low, < 1% overall but significantly higher in patients who undergo temporary pacing before implantation. Lead displacement and undersensing are more likely to occur with atrial than ventricular leads. The overall complication rate for dual chamber pacing, however, is no higher than for single chamber pacing.

Adolescent↗

Coding of movement direction and amplitude in Parkinson's disease: are they differentially impaired (or unimportant)?

A recent study suggested that the preparation of movement direction, but not amplitude, may be selectively impaired by Parkinson's disease (PD). The authors examined the reprogramming of direction only, amplitude only, and direction and amplitude together, and included a control condition in which neither parameter was reprogrammed. The findings suggested that neither direction nor amplitude coding was differentially impaired in PD. Thus the structures affected by PD may not be uniquely involved in specifying only the direction or the amplitude of future movements; these structures probably have more complex higher-level roles.

Aged↗

How do monoclonal antibodies induce tolerance? A role for infectious tolerance?

One of the major goals in therapeutic immunosuppression has been to achieve long-term benefit from short-term therapy. The discovery in the mild-1980s that CD4 antibodies can induce immunological tolerance without depleting CD4+ T cells has reawakened interest in the use of nondepleting monoclonal antibodies for reprogramming the immune system in autoimmunity and in transplantation. Since that time, antibodies to CD11a, CD4OL, CD25, CD3, and CTLA4-Ig have all been shown capable of facilitating tolerance. In order to apply to principle of reprogramming in the clinic, we have sought to understand the mechanisms that are involved in its induction and its maintenance. In a number of allogeneic transplant models (heart, skin, bone marrow) anti-CD4 (+/- CD8) antibodies can be shown to block the rejection process while selectively promoting the development of CD4+ regulatory T cells responsible for a dominant tolerance that is reflected in findings of linked suppression and infectious tolerance. In these models, T cells that have never been exposed to CD4 antibodies become tolerant to grafted antigens by experiencing antigen in the microenvironment of regulatory T cells. Dominant tolerance is not the only mechanism that can be facilitated by CD4 Mab therapy. If allogeneic marrow is given at high cell doses under the umbrella of CD4 and CD8 antibodies, then tolerance can be achieved through clonal deletion. The mechanism by which regulatory CD4+ T cell suppress is not yet defined but could be active or passive. We have proposed the "civil service model" to explain how tolerant T cells might interfere with the responses of competent T cells in such a way as to render them tolerant.

Animals↗

Parkin Induces Ubiquitination and Large Extracellular Vesicle Release of HMGB1 to Activate Antitumor Immunity.

UNLABELLED: Parkin (PRKN) is a mitochondria-associated E3 ubiquitin ligase that mediates mitophagy and organelle quality control. More recently, PRKN has been implicated in stimulating antitumor immunity and reprogramming the tumor immune microenvironment. In this study, we showed that PRKN ubiquitinates the alarmin molecule, high-mobility group box-1 (HMGB1) on Lys146 (K146) using predominantly K48 linkages. By molecular modeling, the in-between-ring domain of PRKN (Gln326-Leu358) made extensive contacts with the amino-terminus A-box of HMGB1 (Met1-Ser42), forming a mitochondria-associated PRKN-HMGB1 complex that juxtaposes K146 to ubiquitin active site residues Gly76 and Arg74. Instead of proteasomal degradation, PRKN ubiquitination of K146 enabled the loading of HMGB1 but not HMGB1 K146A mutant, onto autophagy- and mitochondria-derived large extracellular vesicles (LEV). In turn, released PRKN-HMGB1-LEV stimulated a potent IFN and cytokine response in recipient cells, expanding CD8+ T-cell subsets with effector (CD69+/KLRG1+), self-renewal (TCF1+/PD-1+), and cytotoxic (KLRG1+/GrzB+) properties. Conditional expression of PRKN induced HMGB1 release, activated intratumoral CD8+ T cells, and suppressed syngeneic tumor growth in vivo in a response that was abolished by HMGB1 silencing. These data identify that PRKN-LEV-regulated release of HMGB1 reprograms antitumor immunity via stimulation of IFN signaling and expansion of specialized CD8+ T-cell subsets. SIGNIFICANCE: Parkin ubiquitinates the alarmin molecule HMGB1 to enable its regulated release in large extracellular vesicles that activate interferon signaling, expand specialized CD8+ T-cell subsets, and promote antitumor immunity.

HMGB1 Protein↗

Dissociation of left ventricular hypertrophy, beta-myosin heavy chain gene expression, and myosin isoform switch in rats after ascending aortic stenosis.

BACKGROUND: Reexpression of the fetal beta-myosin heavy chain (beta-MHC) gene was reported to be a marker for phenotypic reprogramming and cardiac hypertrophy in rats. Recent in vitro studies strongly suggested a role of angiotensin II for phenotypic reprogramming. In the present investigation, beta-MHC gene expression was studied in an experimental model of pressure-over-load hypertrophy that is not associated with a concurrent activation of the circulating renin-angiotensin system. METHODS AND RESULTS: Hypertrophy was induced in rats by ascending aortic banding (n = 40). After 7 days, myosin contained 31% (P < .05) of the beta-MHC isoform in banded but < 5% in sham-operated animals. However, no specific elevation of beta-MHC mRNA levels was found in banded animals. In contrast, hearts of rats with abdominal aortic banding displayed a marked increase in beta-MHC mRNA levels (3-fold to 5-fold, P < .05). Both the left ventricular weight and left ventricular peak systolic pressure were significantly elevated compared with sham-operated animals (abdominal aortic banding, +13% and 164 +/- 7 mm Hg; ascending aortic banding, +27% and 191 +/- 9 mm Hg). Plasma renin activity was elevated in rats with abdominal aortic banding (2.5-fold, P < .05) but not in rats with ascending aortic banding. CONCLUSIONS: The results of the present work do not support the concept that increased beta-MHC gene expression is a general "stable late marker" of myocardial hypertrophy in rats. Our results suggest that the stimulation of the renin-angiotensin system is crucial for the activation of the beta-MHC gene.

Analysis of Variance↗

Machine Learning and Metabolomics to Characterize Warburg-Like Metabolic Subtypes in Human Retinal Endothelial Cells Exposed to Risk Factors Associated With Proliferative Diabetic Retinopathy.

PURPOSE: High glucose (HG), hypoxia (Hyp), and their combination are major risk factors for proliferative diabetic retinopathy (PDR). Although these conditions induce features of the Warburg-like metabolic reprogramming in human retinal endothelial cells (HRECs), it remains unclear whether they produce distinct metabolic and angiogenic subtypes. This study aimed to characterize the Warburg-like-associated metabolic heterogeneity induced by these PDR-related risk factors and evaluate the ability of supervised machine-learning models to distinguish these subtypes. METHODS: HRECs were cultured under normoglycemic, HG, Hyp (2% O2), and combined HG-Hyp conditions. Untargeted LC-MS/MS metabolomics quantified metabolites spanning carbohydrates, amino acids, nucleotides, and lipids. Principal component analysis (PCA) assessed overall metabolic variation, and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analysis identified metabolic pathways associated with angiogenesis. In vitro angiogenesis assays measured endothelial tube formation and branching. Nine supervised classifiers (decision tree, logistic regression, na&#xef;ve Bayes, random forest, K-Nearest Neighbors, neural network, gradient boosting, AdaBoost, and Support Vector Machine) were trained on the highest-ranked metabolites selected by the Information Gain Ratio feature-ranking approach. Model performance was evaluated using 10-fold cross-validation, leave-one-out cross-validation (LOOCV), permutation testing, and a classifier stability analysis under biologically meaningful distributional shift using an independent chemically induced hypoxia model (CoCl2). RESULTS: PCA revealed partial separation of metabolic profiles across conditions, indicating different Warburg-like metabolic subtypes. The combined HG-Hyp condition exhibited enhanced angiogenic potential relative to either HG or Hyp alone. KEGG pathway enrichment analysis identified fatty acid biosynthesis and elongation among the most significantly enriched pathways in HRECs under combined HG-Hyp conditions, alongside amino sugar and nucleotide sugar metabolism, glycerophospholipid metabolism, the pentose phosphate pathway, and glycolysis/gluconeogenesis. Supervised machine-learning classifiers distinguished these metabolic subtypes, with AdaBoost and gradient Boosting showing the most balanced, reproducible performance across 10-fold cross-validation, LOOCV, and permutation testing, and remaining the most reliable classifiers under domain-shift testing (area under the curve = 0.88, P = 0.0061). CONCLUSIONS: In this exploratory analysis, HG, Hyp, and their combination drive metabolically and functionally distinct subtypes of Warburg-like metabolic reprogramming in HRECs, with HG-Hyp in combination producing a highly angiogenic phenotype. Boosting-based ensemble classifiers provide a promising framework for detecting these subtypes even under domain-shift conditions, warranting validation in larger independent datasets. TRANSLATIONAL RELEVANCE: Integrating metabolomics with machine-learning classification offers a strategy to identify Warburg-like metabolic subtypes in retinal endothelial cells, providing insights into angiogenic mechanisms and guiding the development of targeted diagnostics or therapeutics for PDR.

Humans↗