Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “systems drift”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Count-dependent filter for smoothing bivariate FCM histograms.

A data-smoothing filter has been developed that permits the improvement in accuracy of individual elements of a bivariate flow cytometry (FCM) histogram by making use of data from adjacent elements, a knowledge of the two-dimensional measurement system point spread function (PSF), and the local count density. For FCM data, the PSF is assumed to be a set of two-dimensional Gaussian functions with a constant coefficient of variation for each axis. A set of space variant smoothing kernels are developed from the basic PSF by adjusting the orthogonal standard deviations of each Gaussian smoothing kernel according to the local count density. This adjustment in kernel size matches the degree of smoothing to the local reliability of the data. When the count density is high, a small kernel is sufficient. When the density is low, however, a broader kernel should be used. The local count density is taken from a region defined by the measurement PSF. The smoothing algorithm permits the reduction in statistical fluctuations present in bivariate FCM histograms due to the low count densities often encountered in some elements. This reduction in high-frequency spatial noise aids in the visual interpretation of the data. Additionally, by making more efficient use of smaller samples, systematic errors due to system drift may be minimized.

Cell Count↗

Real time frequency domain fibreoptic temperature sensor using ruby crystals.

The excited state phosphorescence lifetime of ruby crystals is used to monitor temperature in the physiological range from 15 degrees to 45 degrees C with precision and accuracy less than 1 degree C, in real time. Precision of 0.1 degree C is attained with 3 min integration times. A 500 micron cubic ruby crystal bounded to the distal end of an optical fibre of similar core dimensions is excited with pulsed Ne-He laser light of about 9 microW average power. The instrument uses a sampler for data acquisition, and frequency domain methods for data fitting. The instrument amplifies the a.c. components of the detector output and band limits the signal to 800 Hz. The fundamental frequency of the excitation is set to 24.41 Hz to obtain 32 or less harmonics. This band-limited signal is sampled and averaged between 20 and 100 cycles to obtain temperature measurements in real time. The frequency domain representation of the data is obtained by employing fast Fourier transform algorithms. The phase delay and the modulation ratio, of each sampled harmonic, is then computed. Five to 32 values of the phase and modulation are averaged before computing the sensor lifetime. The technique is capable of measuring precise and accurate excited state lifetimes from subpicowatt luminescent signals in plastic optical fibres. A least squares fit yields the lifetimes of single exponentials. A component of zero lifetime is introduced to account for the backscatter excitation seen by the photodetector leaking through optical interference filters. The phosphorescence lifetimes measured reproducibly to about six parts in 1000, with a 2 s integration time, are used to monitor physiological temperature. Temperatures are computed employing empirical polynomials. The system drift is 3% over 5 h of continuous operation. The instrumentation and methods allow 2.7 s update times and 50 s full response times.

Biomedical Engineering↗

Real-time frequency domain temperature and oxygen sensor with a single optical fiber.

The combined excited-state phosphorescence life-times of an alexandrite crystal and platinum tetraphenylporphyrin Pt(TPP) in a single-fiber sensor are used to monitor temperature and oxygen concentration in the physiological range from 15-45 degrees C and 0-50% O2 with precision of 0.24 degree C and 0.15% O2 and accuracy of 0.28 degree C and 0.2% O2. A 500-micron cubic alexandrite crystal bound to the distal end of a 750-micron-diameter optical fiber core and the Pt(TPP) coated circumferentially with a length of 1 cm from the end of the same fiber are excited with pulsed super-bright blue LED light. This apparatus uses a 125-kHz sampler for data acquisition and frequency domain methods for signal processing. The instrument amplifies both the dc and ac components of the photomultiplier output and band limits the signal to 20 kHz. The fundamental frequency of the excitation is set to 488.3 Hz and the highest harmonic used is the 35th. This bandlimited signal is sampled and averaged over a few hundred cycles in the time domain. The frequency domain representation of the data is obtained by employing fast Fourier transform algorithms. The phase delay and the modulation ratio of each sampled harmonic are then computed. At least four log-spaced harmonic phases or modulations are averaged before decoding the two lifetimes of temperature and oxygen phosphorescent sensors. A component of zero lifetime is introduced to account for the excitation backscatter leakage through optical interference filters seen by the photodetector. Linear and second-order empirical polynomials are employed to compute the temperatures and oxygen concentrations from the inverse lifetimes. In the situation of constant oxygen concentration, the lifetime of Pt(TPP) changes with temperature but can be compensated using the measured temperature lifetime. The system drift is 0.24 degree C for the temperature measurement and 0.59% for the oxygen concentration measurement over 30 h of continuous operation. The instrumentation and methods allow for 6-s update times and 90-s full-response times.

Algorithms↗

Cavity-enhanced spectroscopy in fiber cavities.

We discuss the relative merits of passive and active fiber cavities for ring-down. Ring-down times of approximately 2 micros were recently demonstrated in passive cavities, but operation is restricted to weak evanescent wave interaction. We report on active cavities with amplifiers used for loss compensation, permitting the use of open-path micro-optic cells. Ring-down times of tens of microseconds can readily be achieved and extended to several hundred microseconds in gain-clamped cavities, but relaxation oscillations and system drift impose limits on accuracy and repeatability. A cavity enhancement of 2 orders of magnitude is realistically possible, and sensitivity may be further enhanced if ring-down is combined with established spectroscopic methods.

Journal Article↗

Effects of nonlinearities and uncorrelated or correlated errors in realistic simulated data on the prediction abilities of augmented classical least squares and partial least squares.

Comparisons of prediction models from the new augmented classical least squares (ACLS) and partial least squares (PLS) multivariate spectral analysis methods were conducted using simulated data containing deviations from the idealized model. The simulated data were based on pure spectral components derived from real near-infrared spectra of multicomponent dilute aqueous solutions. Simulated uncorrelated concentration errors, uncorrelated and correlated spectral noise, and nonlinear spectral responses were included to evaluate the methods on situations representative of experimental data. The statistical significance of differences in prediction ability was evaluated using the Wilcoxon signed rank test. The prediction differences were found to be dependent on the type of noise added, the numbers of calibration samples, and the component being predicted. For analyses applied to simulated spectra with noise-free nonlinear response, PLS was shown to be statistically superior to ACLS for most of the cases. With added uncorrelated spectral noise, both methods performed comparably. Using 50 calibration samples with simulated correlated spectral noise, PLS showed an advantage in 3 out of 9 cases, but the advantage dropped to 1 out of 9 cases with 25 calibration samples. For cases with different noise distributions between calibration and validation, ACLS predictions were statistically better than PLS for two of the four components. Also, when experimentally derived correlated spectral error was added, ACLS gave better predictions that were statistically significant in 15 out of 24 cases simulated. On data sets with nonuniform noise, neither method was statistically better, although ACLS usually had smaller standard errors of prediction (SEPs). The varying results emphasize the need to use realistic simulations when making comparisons between various multivariate calibration methods. Even when the differences between the standard error of predictions were statistically significant, in most cases the differences in SEP were small. This study demonstrated that unlike CLS, ACLS is competitive with PLS in modeling nonlinearities in spectra without knowledge of all the component concentrations. This competitiveness is important when maintaining and transferring models for system drift, spectrometer differences, and unmodeled components, since ACLS models can be rapidly updated during prediction when used in conjunction with the prediction augmented classical least squares (PACLS) method, while PLS requires full recalibration.

Algorithms↗

Evaluation of a new catheter for esophageal pH monitoring.

A new catheter, provided with an Ion Sensitive Field Effect Transistor as a pH sensor and incorporating a reference electrode, was evaluated for esophageal pH recording. The pH-sensitivity was 54 mV/pH in vitro, with a linear response between pH 2 and pH 9. Clinical semi-ambulatory 24-hour esophageal pH recordings were carried out in 6 adults and 15 infants. System drift after 24-hour in vivo recording was 0.14 pH units +/- 0.10 pH units, and -0.01 pH units +/- 0.10 pH units, in pH 4.0 and pH 7.0 calibration solution, respectively, in the pediatric group (n = 15). It is concluded that the reusable catheter combines accurate esophageal pH monitoring with optimum patient comfort.

Adult↗

Time course and variability of dark focus.

When the eye is deprived suddenly of visual stimulation, the accommodative system drifts from the previous state of accommodation to a state known as the dark focus. This condition also is known as night myopia. We measured the time course of this drift using a continuously recording infra-red optometer. The time course resembles an exponential decay function with a time constant of 1-3 seconds. The recovery of accommodation to the prior level after visual stimulation is restored suddenly has a time constant of 0.2-0.4 seconds. The state of accommodation in the dark depends on the state of accommodation prior to the onset of darkness. Our subjects showed a zone of accommodative inactivity rather than a single resting point of accommodation.

Accommodation, Ocular↗

Modeling of an impact system with a drift.

A physical model to examine impact oscillators has been developed and analyzed. The model accounts for the viscoelastic impacts and is capable to mimic the dynamics of a bounded progressive motion (a drift), which is important in practical applications. The system moves forward in stick-slip phases, and its behavior may vary from periodic to chaotic motion. A nonlinear dynamic analysis reveals a complex behavior and that the largest drift is achieved when the responses switch from periodic to chaotic, after a cascade of subcritical bifurcations to period one. Based on this fact, a semianalytical solution is constructed to calculate the progression of the system for periodic regimes and to determine conditions when periodicity is lost.

Journal Article↗

Neutral and nonneutral mutations: the creative mix--evolution of complexity in gene interaction systems.

Random drift, while indifferent to the functionality of the molecular features on which it acts, may nevertheless affect evolving molecular mechanisms. It can lead to functional novelty in either gene structure or regulation. In particular, a nearly neutral (in the sense of Ohta), somewhat deleterious mutation can result in a loss of efficiency in gene regulation, and this loss is expected at times to be compensated by a selected event of a particular type: the use of an additional regulatory factor. An accumulation of additional regulatory factors, implying a combination of events of drift and selection, can permit regulatory systems to achieve an increase in both specificity and complexity as mere byproducts of a particular repair process. Nearly neutral mutations thus may, at times, constitute a required pathway for increases in gene interaction complexity. The process seems to point to an inbuilt drive-built into the gene interaction system itself-toward the evolution of higher organisms. This is a matter worthy of experimental exploration, since the general foundations for the evolution of "higher" from "lower" organisms seems so far to have largely eluded analysis.

Animals↗

A thin-film glucose electrode system with compensation for drift.

Thin-film platinum electrodes have been prepared for use in a system for measurement of glucose. Cyclic voltammetry was used to test the electrodes in phosphate and bicarbonate solutions, and in the dialysate of human serum. The peak current output for glucose concentrations between 50-300 mg/dl in a phosphate buffer, and 100-250 mg/dl in the dialysate of human serum, were linear. Two of the three inflection points occurring in the voltammograms are invariant with changes in scan rate, pH, CO2, O2, and glucose. A method for using these points to compensate for voltage drift and current shift is discussed.

Blood Glucose↗

Robust adaptive neural network control of uncertain nonholonomic systems with strong nonlinear drifts.

In this paper, robust adaptive neural network (NN) control is presented to solve the control problem of nonholonomic systems in chained form with unknown virtual control coefficients and strong drift nonlinearities. The robust adaptive NN control laws are developed using state scaling and backstepping. Uniform ultimate boundedness of all the signals in the closed-loop are guaranteed, and the system states are proven to converge to a small neighborhood of zero. The control performance of the closed-loop system is guaranteed by appropriately choosing the design parameters. The proposed adaptive NN control is free of control singularity problem. An adaptive control based switching strategy is used to overcome the uncontrollability problem associated with x0 (t0) = 0. The simulation results demonstrate the effectiveness of the proposed controllers.

Artificial Intelligence↗

Domain segregation in a two-dimensional system in the presence of drift

Motivated by experiments on optical patterns we analyze two-dimensional extended bistable systems with drift after a quench above threshold. The evolution can be separated into successive stages: linear growth and diffusion, coarsening, and transport, leading finally to a quasi-one-dimensional kink-antikink state. The phenomenon is general and occurs when the bistability relates to uniform phases or two different patterns.

Journal Article↗

A specimen-drift-free EDX mapping system in a STEM for observing two-dimensional profiles of low dose elements in fine semiconductor devices.

We developed a specimen-drift-free energy-dispersive X-ray (EDX) mapping system in a scanning transmission electron microscope (STEM) to improve the sensitivity and spatial resolution of EDX elemental mapping images. The amount of specimen drift was analysed from two STEM images before and after specimen drift by using the phase-correlation method, and was compensated for with an image-shift deflector of the STEM by the displacement of the scanning electron beam. We applied this system to observe the two-dimensional distribution of low dose arsenic in silicon semiconductor devices. The sensitivity of the elemental mapping was improved to several tenths atomic % for arsenic atoms while maintaining a spatial resolution of 2 nm.

Letter↗

Adaptive demodulation of dynamic signals from fiber Bragg gratings using two-wave mixing technology.

A two-wave mixing (TWM) interferometer using photorefractive (PRC) InP:Fe crystal is configured to demodulate the spectral shift of a fiber Bragg grating (FBG) sensor. The FBG is illuminated with a broadband source, and any strain in the FBG is encoded as a wavelength shift of the light reflected by the FBG. The wavelength shift is converted into phase shift by means of an unbalanced TWM interferometer. TWM wavelength demodulation is attractive for monitoring dynamic strains because it is adaptive and multiplexable. Adaptivity implies that it can selectively monitor dynamic strains without active compensation of large quasi-static strains and large temperature drifts that otherwise would cause system to drift. Multiplexability implies that several FBG sensors can be simultaneously demodulated using a single demodulator. TWM wavelength demodulation is therefore a cost-effective method of demodulating several spectrally encoded FBG sensors.

Journal Article↗

Drifting pattern domains in a reaction-diffusion system with nonlocal coupling.

Drifting pattern domains (DPDs), i.e., moving localized patches of traveling waves embedded in a stationary (Turing) pattern background and vice versa, are observed in simulations of a reaction-diffusion model with nonlocal coupling. Within this model, a region of bistability between Turing patterns and traveling waves arises from a codimension-2 Turing-wave bifurcation (TWB). DPDs are found within that region in a substantial distance from the TWB. We investigated the dynamics of single interfaces between Turing and wave patterns. It is found that DPDs exist due to a locking of the interface velocities, which is imposed by the absence of space-time defects near these interfaces.

Journal Article↗

Drift of particles in self-similar systems and its Liouvillian interpretation.

We study the dynamics of classical particles in different classes of spatially extended self-similar systems, consisting of (i) a self-similar Lorentz billiard channel, (ii) a self-similar graph, and (iii) a master equation. In all three systems, the particles typically drift at constant velocity and spread ballistically. These transport properties are analyzed in terms of the spectral properties of the operator evolving the probability densities. For systems (i) and (ii), we explain the drift from the properties of the Pollicott-Ruelle resonance spectrum and corresponding eigenvectors.

Journal Article↗