Search PubMedSearch

SEARCH · Search PubMed

Results for “soft-tissue implants”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

286 records · Page 2Linked to original sources

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1 year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI = 3; DBS = 3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1 year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Proteomic insights into the immunomodulatory effects of Ca/Sr co-doped sol-gel coatings for titanium implants.

Ionic functionalization of biomaterial coatings has emerged as a powerful strategy to regulate early host responses at the implant interface. However, how combined Ca/Sr incorporation governs the adsorbed proteome and downstream immune signaling remains poorly understood. This study analyses, employing in vitro tests and proteomics, the effect of adding Sr and Ca to Si-based coatings designed to bioactivate Ti implants. Hybrid Si-based coatings were synthesized by the sol-gel route with a fixed Ca content (0.5 wt%) and increasing Sr contents (0.5, 1.0, 1.5 wt%), and their physicochemical properties, ion release kinetics, and hydrolytic stability were characterized. The coatings remained highly crosslinked despite Ca/Sr incorporation, whereas the highest Sr content increased hydrolytic degradation to around 70% after 56 days. Proteomic analysis identified 183 adsorbed proteins, of which 56 were differentially adsorbed on Ca/Sr-coatings, mainly associated with immune and coagulation pathways. In vitro, RAW 264.7 showed increased gene expression of TNF-α and TGF-β; with an enhanced TNF-α secretion by the addition of Ca and Sr. In parallel, MC3T3-E1 indicated that Ca/Sr-coatings were not cytotoxic and did not impair cell proliferation. However, ALP activity was reduced in the co-doped groups, indicating that the immunomodulatory effects induced by Ca/Sr incorporation were not accompanied by enhanced early osteogenic differentiation. The Ca/Sr combination induced alterations in the adsorption of immune-related proteins, which correlated with the in vitro findings. The deeper insight into how Ca/Sr mixtures modulate protein adsorption on biomaterial surfaces may be key to understanding the immunomodulatory capacity of these bioactive cations.

Animals

Cochlear Implantation in Sickle Cell Disease: A Systematic Review of Feasibility and Outcomes.

INTRODUCTION: Sickle cell disease (SCD) is associated with systemic complications, including sensorineural hearing loss (SNHL) from microvascular occlusion and chronic inflammation. Although reports link SCD to higher rates of SNHL, current evidence is limited by small sample size, varied audiologic methods, and lack of standardized screening. This systematic review summarizes available literature on SNHL and cochlear implantation (CI) in SCD. METHODS: A literature search of PubMed MEDLINE, Embase, Scopus, Web of Science, and CINAHL identified 79 citations. After removal of duplicates, 35 records were screened in Rayyan. Studies published between January 1, 2000, and June 30, 2025, were eligible if they reported patients with SCD who developed hearing loss and underwent CI. Nine full texts were reviewed, and 4 met the inclusion criteria. Screening and review were performed independently by 2 authors per PRISMA guidelines. RESULTS: Across 4 case reports, a total of 5 patients with SCD underwent CI, ranging in age from 2 to 42 years. Four presented with bilateral severe-to-profound SNHL and one with unilateral loss. Implantation was technically feasible in all cases, including patients with cochlear fibrosis or ossification requiring modified insertion techniques. Postoperative outcomes were favorable: all patients demonstrated reliable device function and low impedances. Only 60% showed meaningful auditory benefit, characterized by improved functional speech perception in 2 patients (40%) and access to the speech frequency range with hearing testing going from moderate/profound hearing loss to mild hearing loss in 3 patients (60%). Complications occurred in 2 patients (40%): one developed unilateral middle ear infection leading to meningitis, and another experienced a postoperative pulmonary embolism requiring anticoagulation. The remaining 3 patients (60%) had uncomplicated recoveries with reported improved hearing from moderate/profound hearing loss to mild hearing loss post implantation. CONCLUSION: While CI appears feasible in SCD, our findings suggest that additional data are needed to assess its effectiveness in this patient population. However, evidence is limited to case reports, and complications such as thromboembolism and rapid cochlear fibrosis highlight the need for close perioperative management. More comprehensive studies with larger sample size are required to define surgical risk, optimize management, and establish best practices for timely implantation in this population.

Humans

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n = 50) of articles showed low risk-of-bias, while 7.4% (n = 4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Climate and soil shape Daqu wheat quality and seed microbiome via rhizosphere taxa and microbial assembly.

The grain quality and seed microbiome of Daqu wheat are fundamental determinants of Daqu fermentation performance; however, the mechanisms by which cultivation environments influence these traits via rhizosphere microbial communities remain unclear. Bacterial and fungal communities across the bulk soil-rhizosphere-seed continuum of three wheat cultivars grown in four ecoregions were characterized using absolute quantitative amplicon sequencing. The rhizosphere microbiome was treated as a central intermediary, while the response variables were seed microbial diversity and grain-quality traits, including starch content, protein content, and grain hardness. Twelve physicochemical properties of soil and 11 climatic factors were integrated into a multidimensional association framework. Environmental conditions exerted stronger influences on both seed quality traits and microbial diversity than cultivar identity. Distinct regional signatures were also evident in rhizosphere microbiomes, with environmental gradients explaining community variation more effectively than geographic distance. Bacterial communities exhibited greater sensitivity to environmental fluctuations than fungi. Mantel analyses identified available nitrogen, precipitation, and atmospheric pressure as significant drivers of core rhizosphere taxa (P&#xa0;<&#xa0;0.05). iCAMP revealed that stochastic processes predominantly governed rhizosphere bacterial assembly, whereas stochastic and deterministic mechanisms jointly shaped fungal assembly. Partial least squares path modeling further uncovered a rhizosphere-mediated environment-seed cascade, wherein sunlight intensity and duration, atmospheric pressure, and soil nitrogen directly or indirectly affected seed wet gluten content, grain hardness, and seed microbial diversity through their influences on rhizosphere microbiota. Rhizosphere bacterial diversity was negatively associated with seed bacterial diversity (path coefficient&#xa0;=&#xa0;-0.118, P&#xa0;<&#xa0;0.05), indicating that rhizosphere communities may shape seed endophytic bacterial assemblages via environmental filtering and competitive interactions. Collectively, these findings elucidate how environments shape the quality and seed microbiomes of Daqu wheat, providing scientific guidance for optimal site selection and the standardized production of high-quality brewing wheat for industrial Baijiu.

Triticum

Orbital involvement in sickle cell disease: A systematic review.

Orbital involvement in sickle cell disease (SCD) is rare but potentially vision-threatening and is often misdiagnosed due to overlap with infectious orbital disease. We conducted a systematic review of case reports and series describing orbital complications in patients with confirmed SCD, following PRISMA and MOOSE guidelines. Across 53 studies, 76 cases were identified. Patients were predominantly male (77.6%), with an average age of 13.2 years. Orbital disease was the initial SCD manifestation in 6.6%. Presentations included periorbital edema in all, proptosis in 64.1%, restricted ocular motility in 56.5%, reduced visual acuity in 28.1%, and bilateral involvement in 38.2%. Laboratory findings commonly included leukocytosis (73%) and raised inflammatory markers (86.7%). Radiologically, orbital subperiosteal hematoma were observed in 70%, combined orbital bone infarction and hematoma in 38.2%, and orbital bone infarction alone in 19.7%. Magnetic resonance imaging is critical for accurate diagnosis. Intracranial hemorrhage was present in 9.2%. Less frequent manifestations included orbital apex syndrome, lacrimal gland disease, and nonspecific soft tissue swelling. Management was primarily conservative (82.9%), and surgery was reserved for vision-threatening or intracranial complications. Complete recovery was achieved in 93.1% of cases. While severe vision-threatening complications are uncommon, early recognition remains critical to optimising outcomes in sickle cell orbitopathy.

Humans

The spatial and temporal distribution of Staphylococcus aureus along a tropical Hawaiian watershed.

Staphylococcus aureus is a leading cause of community-acquired skin and soft-tissue infections worldwide. One major route of exposure is recreating in marine waters, but knowledge is limited regarding the drivers of S. aureus in surface waters that discharge into marine environments. This study explores spatial and temporal distributions of S. aureus, including antimicrobial-resistant and virulence genes, using both culture-dependent and molecular techniques across a tropical Hawaiian watershed with a gradient of human influence. Negative binomial generalized linear mixed models revealed that the interaction between spatial and temporal factors was the strongest predictor of S. aureus and associated genes. Cultured S. aureus was highest at mid-watershed sites in summer, which included a popular swimming hole, suggesting human shedding as a significant source. Molecular detection of S. aureus (femA gene) yielded concentrations two orders of magnitude higher than cultured concentrations and peaked at estuarine sites with the greatest nutrients and water residence times. In the winter at upstream sites with no public access, staphylococci antibiotic-resistant (mecA) and S. aureus virulence gene (etb) were elevated, indicating highly pathogenic S. aureus strains in surface waters may originate from zoonotic sources. Our findings indicate that human and zoonotic sources contribute antibiotic-resistant and virulent S. aureus to watersheds, with streams facilitating environmental transmission to marine waters. This watershed-scale assessment enables the prediction of spatial and temporal conditions associated with elevated S. aureus concentrations, thereby reducing exposure and infections.

Staphylococcus aureus

Intravenous Tranexamic Acid Reduces Perioperative Blood Loss in Reduction Mammoplasty With Immediate Implant-Based Reconstruction: A Randomized, Triple-Blinded, Placebo-Controlled Trial.

BACKGROUND: Postoperative hematoma and oozing can compromise outcomes after reduction mammoplasty with immediate reconstruction. Intravenous (IV) tranexamic acid (TXA) is antifibrinolytic, but prospective evidence in this setting is limited. OBJECTIVES: The aim of this study was to determine whether a single pre-incision dose of IV TXA reduces perioperative blood loss and fibrinolytic activation vs placebo. METHODS: In this randomized, triple-blinded, placebo-controlled trial, 60 women (American Society of Anesthesiologists I/II, 18-75 years) undergoing bilateral reduction mammoplasty with immediate implant-based reconstruction received TXA 10&#x2005;mg/kg in 100&#x2005;mL saline or placebo 10&#x2005;min before incision. The primary outcome was total blood loss within 24&#x2005;h (intraoperative suction + swab plus drain output). Secondary outcomes were perioperative changes in hemoglobin, D-dimer and fibrinogen, and complications within 30 days. Intention-to-treat analyses were performed. RESULTS: All patients completed follow-up. Total blood loss was lower with TXA than with placebo (mean &#xb1; standard deviation: 221.1 &#xb1; 72.4 vs 298.1 &#xb1; 90.6&#x2005;mL; mean difference -77.0&#x2005;mL; 95% CI, -122.4 to -31.6; P = .001). Intraoperative loss and 24&#x2005;h drain output were also reduced. Postoperative D-dimer rise was attenuated with TXA (0.31 &#xb1; 0.15 vs 0.49 &#xb1; 0.22&#x2005;&#xb5;g/mL; P = .002); hemoglobin decline was smaller. No thromboembolic, neurologic, or allergic events occurred; no skin-flap necrosis was observed. CONCLUSIONS: Pre-incisional IV TXA safely reduces perioperative bleeding and fibrinolytic activity after reduction mammoplasty. These findings support incorporation of IV TXA into perioperative protocols. LEVEL OF EVIDENCE: 2 (THERAPEUTIC): For image description, please refer to the figure legend and surrounding text.

Humans

Machine learning vs. traditional methods for predicting postoperative cardiac complications after non-cardiac surgery: a systematic review and Bayesian network meta-analysis.

INTRODUCTION: Accurate prediction of peri-operative cardiac complications is critical to optimise pre-operative decision-making. Traditional risk prediction scores, such as the Revised Cardiac Risk Index, show only modest discrimination. Machine learning can model complex, non-linear relationships but their predictive performance compared with traditional scores remains unclear. METHODS: We performed a systematic review and Bayesian network meta-analysis. The primary outcome was postoperative adverse cardiac events following non-cardiac surgery. Prediction models were assessed relative to the Revised Cardiac Risk Index. As many studies evaluated multiple versions of each model type, the highest performing ('best version') and lowest performing ('worst version') results were analysed. Models were ranked using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirteen studies evaluating 54 models and 927,113 patients were included. Machine learning approaches generally outperformed traditional risk scores. Automated machine learning ranked highest (SUCRA 96.6) showed the greatest improvement in the best version analysis (mean difference (MD) 0.28 (95%CrI 0.16-0.40)) and remained superior in the sensitivity analysis (MD 0.30 (95%CrI 0.14-0.45)). Gradient boosting models showed superior performance over the Revised Cardiac Risk Index across analysis (best version: MD 0.20 (95%CrI 0.14-0.26), worst version: MD 0.18 (95%CrI 0.12-0.25), SUCRA 82.4). The Gupta Perioperative Risk for Myocardial Infarction or Cardiac Arrest score outperformed the Revised Cardiac Risk Index in the best version analysis (MD 0.16 (95%CrI 0.01-0.32)). Between-study heterogeneity was low. None of the included studies externally validated their machine learning models and only six were judged to be at low risk of bias. DISCUSSION: Most machine learning models showed better discrimination than traditional risk scores, with automated machine learning and gradient boosting models ranking highest. However, study quality, calibration reporting and absence of external validation limit immediate clinical adoption. Prospective, multicentre evaluation is required before integration of these models into peri-operative practice.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

An Overview of Red Breast Syndrome: A Qualitative Systematic Review of the Literature and a Single-Center Case Series.

Red breast syndrome (RBS) is an uncommon inflammatory complication that may occur following implant-based breast reconstruction and can clinically mimic surgical-site infection. This qualitative systematic review, based on comprehensive PubMed and Scopus searches, summarizes the existing literature on RBS, focusing on its etiology, clinical presentation, diagnostic characteristics, and therapeutic approaches following breast reconstruction using acellular dermal matrices (ADMs). A management protocol is proposed based on available data, and a single-center case series is presented from our Hospital, including patients who developed RBS after direct-to-implant reconstruction with ADM between January 2022 and December 2024. Twenty-nine studies met the inclusion criteria, comprising case reports, case series, and retrospective or prospective cohort studies. The reported incidence of RBS ranged from 0% to 29.6%. Proposed etiologies include endotoxin contamination, residual cellular debris, delayed hypersensitivity reactions, and lymphatic or vascular impairment of mastectomy flaps. Most reports described localized erythema confined to the area of the ADM, with normal inflammatory markers and negative imaging findings, whereas antibiotic therapy frequently failed to achieve improvement. Corticosteroids represented the most consistently effective treatment, although some cases required ADM removal or replacement. In our institutional case series (n = 8), symptom onset occurred between 4 weeks and 7 months postsurgery. Inflammatory markers remained within normal limits, imaging rarely demonstrated fluid collections, and symptoms resolved within days to weeks with corticosteroid therapy or conservative management. This review consolidates current evidence, proposes a diagnostic-therapeutic algorithm and highlights the need for prospective investigations and manufacturer-level endotoxin testing to elucidate pathogenesis and optimize clinical management. Level of Evidence: 2 (Risk) For image description, please refer to the figure legend and surrounding text.

Humans

Socket motility assessment of anophthalmic sockets: a systematic review.

PURPOSE: Systematically review and categorize the methods used to assess socket and prosthetic motility in anophthalmic patients following enucleation or evisceration. METHODS: A systematic review was conducted in accordance with PRISMA guidelines. PubMed, Embase, Web of Science, and Scopus were searched from inception through September 2024. Studies reporting qualitative or quantitative assessments of motility in anophthalmic sockets or ocular prostheses were included. Motility assessment methods were categorized as qualitative (descriptive or graded clinical evaluation) or quantitative (numerical measurements in millimeters, degrees, or objective tracking systems). RESULTS: Thirty-five studies encompassing 1,819 patients met inclusion criteria. Nineteen studies used qualitative assessment methods, including subjective observation, graded scales based on cardinal gaze positions, or comparison with the contralateral eye. Sixteen studies employed quantitative techniques, such as the Kestenbaum limbus test, Lister perimeter measurements, conjunctival or limbal markings, photographic image analysis, infrared eye-tracking systems, and magnetic search-coil technology. Considerable heterogeneity was observed in measurement techniques, reporting standards, timing of assessment, and distinction between socket and prosthetic motility. CONCLUSIONS: Substantial variability exists in the methods used to assess motility in anophthalmic sockets, limiting comparability across studies. Establishing standardized, feasible, and reproducible assessment approaches may improve outcome reporting and facilitate meaningful comparisons in future oculoplastic research.

Humans

Effects of erector spinae plane block on postoperative pain in patients undergoing implant-based breast reconstruction for breast cancer: a randomized controlled trial.

BACKGROUND: Implant-based breast reconstruction after mastectomy causes acute pain. OBJECTIVE: To determine whether a single-shot T5 erector spinae plane block (ESPB) reduces postoperative pain. DESIGN: Single-center, RCT with allocation concealment; blinded assessors and statisticians. SETTING: Tertiary cancer center in China. PATIENTS: 100 adults scheduled for radical mastectomy with implant reconstruction were randomized (1:1); follow-up complete. INTERVENTION: Before induction, ESPB was given under ultrasound guidance at T5 with 30 mL of 0.375% ropivacaine plus dexmedetomidine 1 &#x3bc;g/kg; controls received no block. Standardized general anesthesia and postoperative PCA for both groups. MAIN OUTCOME MEASURES: Resting NRS at 6 h (MCID=1). Secondary outcomes were opioid consumption, quality of recovery, and PONV. RESULTS: ESPB did not significantly reduce resting pain at 6 h at the median (&#x3c4; =0.50; adjusted difference -0.9; p = 0.08). At the upper tail, pain intensity was lower (&#x3c4; = 0.75; -1.8; p <0.01). Repeated measures provided additional time-point information, improving estimation precision and test sensitivity. ESPB get lower pain scores at 6, 12, and 24 hours (all p <0.01). But, the 95% CI includes the MCID, the clinical benefit remains uncertain. Opioid use decreased at 24 h (-13.5 mg; p <0.01) and 48 h (-6.6 mg; p <0.01). Quality of recovery improved at 24 h (difference 5 points; p <0.01), but not later. No differences were observed in intraoperative hemodynamics or PONV. CONCLUSIONS: Single-shot T5 ESPB with perineural dexmedetomidine may reduce postoperative pain and opioid requirements and improve early recovery. Further large trials are warranted. Clinical relevance remains to be confirmed. TRIAL REGISTRATION: ClinicalTrials.gov NCT06143020.

Humans

Bioabsorbable vs. titanium screws in first metatarsophalangeal joint arthrodesis: a pilot randomized controlled trial with 2-year follow-up.

INTRODUCTION: To assess the feasibility and preliminary clinical outcomes of bioabsorbable screw fixation in first metatarsophalangeal joint arthrodesis compared to conventional titanium screw fixation. METHODS: In this prospective pilot randomized controlled trial, 30 patients were allocated 1:1 to bioabsorbable or titanium cannulated lag screw fixation. Arthrodesis was performed using a cup-and-cone technique at two Finnish hospitals. Full weight-bearing in an orthopaedic shoe was allowed after six weeks. Outcomes included AOFAS and VA-FAS FA-VAS scores, union rates, and complications assessed at 3, 6, 12, and 24 months. RESULTS: Both groups showed significant functional improvement with no between-group differences. At 24 months, mean AOFAS scores were 89.1 (SD 2.7) in the titanium group and 90.0 (SD 0.0) in the bioabsorbable group (p = 0.23). Mean FA-VAS total scores (sum of pain, function, and complaints subscales) were 1948 (SE 59.4) in the titanium group and 1914 (SE 61.4) in the bioabsorbable group (p = 0.655). Union rate was 90% overall; nonunion occurred in one titanium and two bioabsorbable patients, all requiring revision. No implant-related complications or hardware removal surgeries were recorded. Degradation of bioabsorbable screws caused no adverse clinical or radiographic reactions. CONCLUSIONS: Bioabsorbable screws appear safe and feasible in first metatarsophalangeal joint arthrodesis, with preliminary outcomes comparable to titanium fixation. These findings support the conduct of a larger confirmatory trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03133039, registered 28 April 2017. https://clinicaltrials.gov/ct2/show/NCT03133039.

Humans

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3&#x2009;mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40&#x2009;mL, 2-3&#x2009;mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0&#x2009;mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

Volumetric bone marrow cellularity (VBMC) assessment from routinely processed trephines using three-dimensional x-ray histology and gaussian peak modelling.

Objective.Bone marrow cellularity is routinely estimated from a small number of two-dimensional histology sections, making assessment sensitive to section representativeness, processing artefacts and observer interpretation. Three-dimensional (3D) x-ray histology (XRH), using x-ray computed microtomography (&#xb5;CT), enables non-destructive whole-block imaging of trephine biopsies. This study evaluated whether XRH combined with Gaussian peak modelling could provide a pragmatic whole-block volumetric bone marrow cellularity (VBMC) estimate from formalin-fixed paraffin-embedded (FFPE) trephine biopsy blocks.Approach.Six routinely processed FFPE bone marrow trephine blocks were imaged using &#xb5;CT-based XRH at &#x223c;15 &#xb5;m spatial resolution. VBMC was defined as the red-marrow (RM) fraction of the marrow soft-tissue compartment, RM/(RM + intra-biopsy wax), with wax serving as the volumetric proxy for adipocyte/yellow marrow space. Whole-volume greyscale histograms were modelled using a three-peak Gaussian approach representing intra-biopsy wax, RM and demineralised trabecular matrix. Peak-height and area-under-the-curve metrics were compared with whole-volume 3D segmentation and clinical two-dimensional (2D) cellularity estimates.Main Results.Gaussian peak modelling successfully approximated the segmented tissue-phase distributions. The peak-height-derived VBMC metric showed the closest agreement with whole-volume 3D segmentation, with an average absolute percentage difference of 9.3%, compared with 18.6% for clinical expert 2D cellularity estimates. The area-under-the-curve metric followed similar trends but consistently overestimated VBMC. Clinical 2D cellularity broadly followed whole-biopsy trends but showed one discordant case not explained by slice-position sampling alone. XRH also enabled unrestricted virtual reslicing and visualisation of sectioning-associated artefacts prior to further microtomy.Significance.Pre-sectioning XRH combined with Gaussian peak modelling provides a rapid, segmentation-free route to volumetric cellularity estimation from intact clinical FFPE trephine blocks. The approach supports objective whole-biopsy assessment while remaining compatible with routine histopathology workflows, reflecting the expected limitations of section-based visual estimation despite its role as the current clinical standard. In the near term, it could provide a non-disruptive adjunct to conventional 2D cellularity reporting, pending larger validation studies.

Imaging, Three-Dimensional

Flap Versus Tunneling for Horizontal Ridge Augmentation With FDBA and i-PRF: A Randomized Controlled Clinical Trial.

AIM: This study evaluated the efficacy of conventional flap and tunneling techniques for horizontal alveolar ridge augmentation using freeze-dried bone allograft (FDBA) particles combined with injectable platelet-rich fibrin (i-PRF). MATERIALS AND METHODS: Forty-five patients were randomly allocated to one of three groups (n&#x2009;=&#x2009;15 each): conventional flap (CF), tunneling with membrane (TM), or tunneling without membrane (TnM). Preoperative ridge width was measured via cone beam computed tomography (CBCT). All augmentation procedures incorporated FDBA and i-PRF; an absorbable collagen membrane was applied in the CF and TM groups. Follow-up assessments, including CBCT imaging and histomorphometric analysis, were conducted 6&#x2009;months postoperatively. For normally distributed data, ANOVA with Tukey's post hoc test and paired samples t-test were applied. Non-normally distributed data were analyzed using Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed-rank tests. RESULTS: Statistical analysis was performed on 43 patients. All groups demonstrated an increase in ridge width after 6&#x2009;months. At the 2&#x2009;mm level, the mean width gain was 1.28&#x2009;mm (95% CI: 0.17 to 2.40) in the TM group, 2.85&#x2009;mm (95% CI: 1.80 to 3.89) in the TnM group, and 1.95&#x2009;mm (95% CI: 1.07 to 2.83) in the CF group. However, statistical analysis revealed no significant intergroup variation (p&#x2009;>&#x2009;0.05). Histomorphometric assessments similarly demonstrated comparable outcomes across all groups, with no statistically significant differences observed (p&#x2009;>&#x2009;0.05). CONCLUSION: Within the limitations of this study, the tunneling technique, regardless of membrane use, appears to be a clinically viable alternative to the conventional flap method for horizontal alveolar ridge augmentation. However, further studies with longer follow-up periods are required to substantiate these findings. TRIAL REGISTRATION: irct.behdasht.gov.ir identifier: IRCT 20101204005305N21.

Humans