Search PubMedSearch

SEARCH · Search PubMed

Results for “polyp detection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

340 records · Page 2Linked to original sources

Influence of soil types with different soil-forming process on the qualitative and quantitative detection of microplastics by near-infrared spectroscopy.

Microplastics (MPs) have become a pressing global environmental threat, with soils-acting as sinks for MPs from multiple sources-gaining increasing attention. Near-infrared (NIR) spectroscopy offers a promising tool for MPs detection due to its rapid, non-destructive, and field-applicable features. Although previous studies have focused on the effects of individual soil components on the NIR detection performance of MPs, there is still a lack of systematic research on how the complex background-formed by the coupling of multiple physicochemical properties in natural soils-affects detection performance. This study focuses on soil types with different soil-forming processes, selected five representative agricultural soils to systematically evaluate how the combinations of physicochemical properties they represented affect the performance of NIR-based qualitative and quantitative analysis of MPs in soils. The results demonstrated that soil type significantly affected both the spectral response and detection performance of MPs. Brown Pedocals and Brown Earth exhibited clearer characteristic absorption and stronger linear responses, achieving higher identification accuracy under low (<1.5 %) or zero MPs concentrations and the best quantitative performance (R2 &#x2265; 0.988, prediction set root mean square error (RMSEP) &#x2264; 0.110 %). In contrast, Phaeozem and Red Soil were more prone to misclassification at low concentrations, while Fluvo-aquic Soil showed the poorest quantitative performance. This study is the first to reveal, at a holistic level, the critical constraints posed by natural soil complexity on the NIR detection of MPs, offering targeted empirical evidence to support the application of NIR technology in real-world soil environments.

Soil

Portable metagenomics for preventive surveillance and outbreak control in livestock and poultry: Pathogen detection, resistome profiling, and antimicrobial stewardship.

Conventional diagnostics for livestock and poultry outbreaks commonly rely on culture or targeted PCR panels, which may be too slow or too narrow to guide early control decisions. Portable metagenomics, particularly real-time nanopore sequencing, offers a route to broad pathogen detection, antimicrobial-resistance gene profiling, and outbreak investigation within an integrated workflow. This implementation-focused review evaluates how near-point-of-care metagenomics may support preventive veterinary medicine through earlier detection, surveillance, cohorting, biosecurity decisions, and antimicrobial stewardship. We synthesize sample-to-answer workflows for enteric and respiratory disease in food-producing animals, including sampling, nucleic-acid extraction, host depletion or target enrichment, library preparation, sequencing, bioinformatics, quality control, and interpretation. Applications in calf diarrhea, bovine respiratory disease, poultry outbreaks, mastitis, and resistome monitoring are considered alongside the central limitation that detection alone does not establish causation. Pathogen and resistance-gene signals must therefore be interpreted with clinical signs, lesions, epidemiology, controls, and confirmatory testing. We also propose a minimum reporting checklist, intended as a practical framework rather than a validated consensus standard. Portable metagenomics is not a replacement for conventional diagnostics, but appropriately validated workflows can reduce uncertainty during time-sensitive outbreaks and support more judicious antimicrobial use.

Animals

Recent advances in electrode materials for electrochemical detection of zearalenone.

Zearalenone (ZEN) is an estrogenic mycotoxin commonly found in cereals, animal feed, and processed foods, making it an important concern for food safety and public health. Conventional chromatographic and immunological methods can detect ZEN; however, they often require expensive instruments, lengthy sample preparation, and skilled personnel, which restrict their use for rapid and on-site testing. Electrochemical sensors have attracted enormous interest of the scientific community because of their high sensitivity, rapid response, low cost, miniaturization potential, and compatibility with portable systems. The analytical performance of the electrochemical sensors is strongly influenced by electrode materials, morphology, conductivity, porosity, surface functionality, and the efficiency of bioreceptor immobilization. Despite several reviews on mycotoxin detection, a systematic assessment connecting electrode-material design, modification strategies, sensing mechanisms, and electroanalytical performance specifically for ZEN sensing remain limited. This review critically evaluates recent advances in metal oxides, carbon-based materials, metal-organic- and covalent organic frameworks, MXenes, polymers, and hybrid composites for electrochemical ZEN detection. Particular attention has been given to their roles in electron transfer, analyte enrichment, selectivity, and real-sample analysis. The review also compares the major limitations of current sensing systems, including complex fabrication, matrix interference, insufficient long-term stability, poor inter-electrode reproducibility, and limited scalability. Finally, future directions for developing robust, cost-effective, portable, and commercially viable ZEN sensors are discussed.

Journal Article

Selective and sensitive colorimetric sensing of carbosulfan based on BiO2-x/Bi2O2.75 nanosheets with excellent haloperoxidase-like activity.

The development of colorimetric methods based on directly inhibiting nanozyme activity for pesticide detection has attracted considerable attention. In this study, we report a novel colorimetric sensing strategy utilizing BiO2-x/Bi2O2.75 nanosheets (BiO2-x/Bi2O2.75 NSs) with haloperoxidase (HPO)-like activity for the rapid and sensitive detection of carbosulfan (CBS) in foods. Oxygen-vacancy-rich BiO2-x/Bi2O2.75 NSs with HPO-like activity were rationally constructed. Kinetic studies revealed a remarkable Michaelis-Menten constant (Km) of 0.014&#xa0;mM for I-, indicating a higher affinity for iodide ions than other reported HPO-like nanozymes, as evidenced by its lower Km. Under acidic conditions, CBS tends to be hydrolyzed to produce reductive sulfide species, which directly inhibit the iodoperoxidase-like activity of BiO2-x/Bi2O2.75 NSs, enabling selective detection with a limit of detection (LOD) of 0.18&#xa0;&#x3bc;g/mL and a linear range of 0.20-100&#xa0;&#x3bc;g/mL. When the concentration of interfering pesticides and substances was 5 times that of CBS, the sensor remained unaffected, exhibiting excellent stability and specificity. This work contributes to the detection of CBS in complex food matrices, bridging the application gap of HPO-like nanozymes in pesticide detection and providing a promising method for food safety detection.

Colorimetry

A point-of-use SERS assay for rapid detecting difenoconazole and flusilazole residues in fruit juices using Au/COF substrate.

We developed a ready-to-use surface-enhanced Raman scattering (SERS) sensor for rapid, pretreatment-free detection of difenoconazole (DIF) and flusilazole (FLU) in peach and lychee juices. The substrate combines Au nanoparticles (AuNPs) with covalent organic frameworks (COF) and is implemented on a portable 25-well plate, enabling in situ testing. Juices can be directly applied to the SERS-active Au/COF composite, allowing simultaneous adsorption and signal generation. The correlation between SERS intensity and logarithmic concentration yielded R-values between 0.925 and 0.986, meeting the monitoring needs of non-laboratory scenarios. The entire workflow completes within 12&#xa0;min, offering a faster alternative to conventional methods while maintaining high sensitivity and reproducibility. Detection limits reach 0.96-1.22&#xa0;ppb for DIF and FLU, both of which are below the regulatory maximum residue limits. Distinct SERS fingerprints enable reliable discrimination of mixed residues across juice matrices, supporting rapid on-site monitoring and cost-effective pesticide surveillance.

Triazoles

A homogeneous immunoassay based on AlphaLICA technology for detecting florfenicol residues in animal-derived foods.

Florfenicol (FF), a broad-spectrum amide antibiotic widely used in livestock, poultry, and aquaculture, poses potential threats to food safety and public health due to its residual accumulation. In this study, a novel homogeneous immunoassay based on Amplified Luminescent Proximity Homogeneous Assay (AlphaLICA) technology was developed for the first time for rapid screening of FF residues in milk and egg matrices. By covalently immobilizing the FF-BSA conjugate and goat anti-mouse IgG onto luminescent and photosensitive microspheres, respectively, the method achieved wash-free, homogeneous quantitative detection through a competitive immunoreaction. Under optimized conditions, the assay exhibited a linear range of 0.2-16.2 ng mL-1, with a limit of detection of 9.7 pg mL-1 and a limit of quantification of 183 pg mL-1. The intra- and inter-batch coefficients of variation ranged from 3.08% to 5.70% and 2.44% to 7.09%, respectively. Spike recovery rates in milk and egg matrices ranged from 93.18% to 107.17% (RSD &#x2264; 5.57%). Cross-reactivity with 11 other common antibiotics, including chloramphenicol and thiamphenicol, was below 0.1%, demonstrating excellent specificity. Comparative analysis with a commercial ELISA kit showed high consistency (r2 = 0.9332, p < 0.001). With high sensitivity, strong specificity, simple operation, and a detection time of only 10 min, this method provides a reliable technical platform for high-throughput, rapid monitoring of FF residues in milk and egg matrices.

Journal Article

Emergence of a Novel, Phenotypically Difficult-to-Detect Vancomycin-Resistant Enterococcus faecium Clone (ST117/CT7799).

A significant increase of vancomycin-resistant Enterococcus faecium (VREfm) infections was observed in South-Eastern Austria since 2024. The prolonged outbreak is caused by a novel vanB-VREfm clone (ST117/CT7799, "VREfmstyr"). This study characterizes the atypical difficult-to-detect resistance phenotype and assesses the genomic relatedness of the isolates. Patient and outbreak characteristics were investigated including whole genome sequencing of the isolates. Sensitivity of broth microdilution (BMD), gradient tests (GT), disk diffusion (DD), and automated susceptibility testing (VITEK2) was compared. The performance of commercial screening media was evaluated. From sporadic detections in early 2024 case numbers began to rise during the year. In 30/31 (97%) of all cases, intra-hospital transmission was considered likely and an association with invasive procedures was identified in most cases. Core genome multilocus sequence typing revealed only six allelic differences between VREfmstyr isolates collected in a 12-month period, all belonging to the E. faecium ST117/CT7799 lineage. BMD detected vancomycin resistance (MIC&#x2009;>&#x2009;4&#x2009;mg/L) in no more than 16/31 (52%) of isolates after 24&#x2009;h incubation, while GT and DD misclassified all isolates. Only prolonged incubation improved the performance of these assays. VITEK2 analysis, however, correctly classified all 31 isolates. Of four commercially available VRE-screening agars, only one was capable of detecting VREfmstyr after 24&#x2009;h incubation. The emergence and clonal dissemination of VREfm ST117/CT7799 reveals a serious diagnostic gap as commonly used diagnostic algorithms fail to reliably detect this resistance phenotype. Our findings should help to further evaluate the true geographical distribution and clinical significance of this novel VREfm clone.

Enterococcus faecium

Detectable C-Peptide and Diabetic Ketoacidosis Risk in Type 1 Diabetes.

OBJECTIVE: To investigate whether detectable C-peptide levels in type 1 diabetes is associated with a lower risk of diabetic ketoacidosis (DKA). RESEARCH DESIGN AND METHODS: We analyzed the Diabetes Control and Complications Trial publicly available data repository for the association between detectable stimulated C-peptide (>0.2 nmol/mL, measured annually) and DKA incidence over an average 6.5-year follow-up. We used crude and adjusted Andersen-Gill models for recurrent DKA events with time-dependent covariates. RESULTS: Of the 1,441 participants (53% male, median age 27 years), 129 (9%) experienced 180 DKA events. Of these events, 179 (99.44%) occurred after C-peptide was &#x2264;0.2 nmol/L in the prior year and only 1 event occurred with C-peptide >0.2 nmol/L. C-peptide >0.2 nmol/L was associated with a DKA hazard ratio of 0.07 (95% CI 0.01-0.48; P = 0.007), consistent across adjusted models. CONCLUSIONS: Endogenous insulin production was significantly associated with lower DKA risk, suggesting that treatments preserving insulin production could decrease long-term DKA risk.

C-Peptide

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video).

BACKGROUND AND STUDY AIMS: Pancreatobiliary endoscopic ultrasonography (EUS) is technically demanding, and supervised training opportunities are limited. We developed an artificial intelligence (AI) overlay system for detecting solid pancreatic lesions (SPL) and recognizing pancreatic parenchyma (PP) and evaluated its effect on reader performance. PATIENTS AND METHODS: Across six centers, two deep learning-based models were trained using expert-annotated EUS frames. We then conducted a randomized, two-sequence, two-period crossover reader study in which eight endosonographers (five novices and three experts) interpreted image sets with and without AI assistance. The primary endpoint was superiority of sensitivity for SPL detection among novices; key secondary endpoints included specificity and PP recognition. RESULTS: From 118 patients, 120 SPL-positive/negative image sets and 160 PP-positive/negative image sets were constructed. Among novices, AI assistance improved SPL detection sensitivity (88.7% vs. 76.8%, p&#x2009;<&#x2009;0.001) and accuracy (86.4% vs. 78.7%), while specificity met the predefined noninferiority criterion (84.2% vs. 80.5%, p&#x2009;<&#x2009;0.001). For PP recognition, sensitivity increased numerically (86.3% vs. 83.3%) but did not meet the predefined superiority criterion (p&#x2009;=&#x2009;0.095); specificity met the noninferiority criterion (87.8% vs. 81.0%), and accuracy increased from 82.1% to 87.0%. Among experts, sensitivity was maintained for both tasks, whereas specificity increased with AI assistance. CONCLUSIONS: AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.

Humans

Ultrasound protocols used to detect vascular gas emboli in divers: a systematic review.

INTRODUCTION: Venous gas emboli (VGE) detected via ultrasound can be used as a surrogate marker for decompression stress. While Doppler ultrasound is the historical gold standard, two-dimensional (2D) ultrasonography offers advantages for on-site monitoring, including a wider field of view and reduced dependence on noise-free environments. This systematic review evaluates 2D ultrasonography protocols used in decompression research since the 2015 International Meeting on Ultrasound for Diving Research, identifying methodological similarities, differences, and adherence to consensus recommendations. METHODS: A search of PubMed and Scopus identified studies using 2D ultrasound to detect VGE in divers. Inclusion criteria were: (1) use of 2D ultrasound, (2) detection of VGE or monitoring of decompression stress, (3) inclusion of a diver cohort, and (4) publication after 2015. Data extraction focused on VGE scoring systems, ultrasound hardware, measurement protocols, and operator experience. Risk of bias was assessed using ROBINS-I-V2, and compliance with the 2015 consensus recommendations was evaluated. RESULTS: Twenty studies were included. The Eftedal-Brubakk scale was most commonly used (n = 15), with cardiac ultrasound as the primary imaging modality; one study assessed a peripheral vessel. Common shortcomings included post-dive measurements lasting less than two hours, underreporting of operator experience and hardware specifications, limited individual-level data, and inappropriate use of parametric statistics for ordinal bubble grade data. No study fully complied with all consensus recommendations. CONCLUSIONS: This review demonstrates that, although two-dimensional ultrasound is widely used for post-dive VGE assessment, methodological heterogeneity with multiple shortcomings remain. Furthermore, nearly all studies restricted imaging to the heart, thus leaving peripheral vessel assessment largely unexplored.

Embolism, Air

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

In Situ Hybridization and RT-PCR Detection of Nervous Necrosis Virus in Fourfinger Threadfin, Eleutheronema tetradactylum, in Taiwan.

Between April and July 2020, suspected outbreaks of nervous necrosis virus (NNV) infection were observed in fourfinger threadfin (Eleutheronema tetradactylum) fingerling hatcheries in Pingtung County, southern Taiwan. Affected fish exhibited spiral swimming behaviour and abdominal distension, resulting in mortality rates between 50% and 100%. Histopathological examination showed severe vacuolation in the brain and ocular tissues, with large oval and/or irregular basophilic cytoplasmic inclusion bodies in the brain. Phylogenetic analysis of the viral replicase (RNA1) and capsid protein (RNA2) genes revealed high nucleotide sequence identities among the isolates in this study, with sequence similarity rates of 96.9%-99% for RNA1 and 98.2%-99.0% for RNA2 compared to RGNNV reference strains available in the NCBI GenBank database. This is the first detection of betanodavirus in fourfinger threadfin in Taiwan, using RT-PCR and ISH. A positive correlation between elevated water temperatures and disease severity indicates the need for year-round surveillance and genomic analysis to clarify the epidemiology of FTNNV. The data suggest that infected eggs may facilitate the vertical transmission of Betanodavirus. Crucially, utilising virus-free broodstock, alongside routine health screening and environmental control, is essential for mitigating NNV risks in fourfinger threadfin aquaculture.

Animals

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30&#xb7;9% (114 of 369 patients) with HD-WL versus 33&#xb7;8% (123 of 364 patients) with CADe assistance (odds ratio 1&#xb7;14 [95% CI 0&#xb7;83-1&#xb7;57], p=0&#xb7;41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85&#xb7;9% (95% CI 82&#xb7;0-89&#xb7;1) and specificity was 91&#xb7;4% (89&#xb7;4-93&#xb7;0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans