Search PubMedSearch

SEARCH · Search PubMed

Results for “erosive tooth wear”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2Linked to original sources

Nutrition and Diet-Related Training and Curriculum in the US Predoctoral Dental Programs.

PURPOSE: Nutrition and diet are vital for oral and systemic health. It is unclear how well US predoctoral dental programs prepare students in nutrition screening and counseling. This study analyzed US dental school curricula on these topics. METHODS: A cross-sectional online survey was sent to the publicly available email addresses of 67 of 72 academic dental deans at US Commission on Dental Accreditation-accredited dental schools. Items assessed availability, modes and hours of instruction, curricular topics, clinical integration, and instructors. Descriptive statistics summarized responses. RESULTS: A total of 21 academic deans responded, for an overall response rate of 29%. Most (85%) of responding academic dental deans reported that nutrition and diet education was mandatory, with none treating it as optional. Of these schools, 83% offered both classroom and clinical training, while 17% provided only didactic teaching. Didactic hours varied; 42% reported 10 or fewer hours. Foundational nutrition topics were common, although dietary guidelines such as MyPlate were reported less often (66%). Oral health-related nutrition content was broadly covered, with all respondents reporting instruction related to caries, erosion, periodontal disease, and oral dysfunction. Counseling content was less consistent, particularly public health nutrition (67%) and the impact of oral dysfunction on diet and nutrition (72%). CONCLUSION(S): Most responding academic dental deans report including nutrition and diet education in their curricula. However, it remains uncertain whether these topics are incorporated at schools that did not participate in the survey. Variability in curricular time, counseling, and teaching highlights the need for clearer competencies and more clinical training. Improving this could better prepare future dentists for common dietary risks affecting oral and systemic health.

dental caries

Coupling of spectroscopy and nitrogen-oxygen isotopes unveils the mechanisms of dissolved organic matter and nitrate pollution in lakes within the agro-pastoral transition zone.

Lakes in arid and semi-arid regions are subjected to severe ecological stress, such as organic pollution, eutrophication, and salinization, due to climate change and human activities. This study investigates Chagannur Lake, a typical arid-region lake that is representative and ecologically sensitive in Northern China's agro-pastoral ecotone, to uncover its pollution characteristics and mechanisms. We employed fluorescence spectroscopy and stable isotope analysis to trace dissolved organic matter (DOM) and nitrate sources. The DOM composition was dominated by microbial metabolic byproducts and protein-like substances, suggesting that microbial processes are key to organic matter transformation. Source apportionment revealed that pollutants primarily originated from livestock and poultry manure (37.6 %), agricultural fertilizers (35.6 %), and soil erosion (24.7 %), with agricultural fertilizers contributing most significantly in the Gogstai River (63.3 %). A structural equation model (SEM) coupling spectral and mass spectrometric data revealed that microbial transformation significantly impairs the lake's self-purification capacity, thereby promoting pollutant accumulation (path coefficient = 0.91,*p < 0.05). Moreover, microbial processes link endogenous and exogenous pollution, a mechanism effectively traced by isotopic and fluorescence indices (path coefficient = 0.55, &#x204e;&#x204e;p < 0.01). These findings enhance the understanding of pollution sources and transformation mechanisms in arid-region lakes and offer foundational theoretical support for policymakers engaged in pollution control strategies.

Lakes

Urban stormwater infrastructure as a microplastic superhighway: a critical review of transport dynamics, modelling, and mitigation across pavements and drainage networks.

This review examines the transport, fate, modelling, and mitigation of Microplastics (MPs) in urban stormwater infrastructure, with emphasis on pavements, runoff pathways, micro-drainage, and macro-drainage systems. Following a systematic review approach, more than 1000 records were screened and approximately 50 core studies were retained when they addressed urban stormwater or drainage-related MP transport with adequate methodological reporting; marine-only studies and biological-effect studies without direct relevance to transport processes were excluded. The evidence shows that stormwater systems function not merely as passive conduits but as dynamic reactive transport systems with temporary storage, where particle mobilisation, sedimentation, resuspension, and temporary retention regulate MP export. Road surfaces, especially high-traffic areas, are major reservoirs of tyre wear, road-marking, atmospheric, and litter-derived particles that are rapidly mobilised during rainfall. Conventional grab sampling may underestimate MP loads, which in some cases exceed treated wastewater effluent loads by up to six-fold. Drainage structures such as manholes can immobilise up to 17.3% of near-neutrally buoyant particles, while biofouling and aggregation may shift buoyant polymers from wash-load to bedload. Mitigation systems, including permeable pavements, bioretention, wetlands, and technical inserts, can achieve high removal of coarse MPs, but performance declines for fine particles below 100&#xa0;&#xb5;m. The review highlights the need for standardised flow-proportional sampling, physically informed modelling, and treatment-train strategies targeting both surface sources and in-network storage.

Microplastics

Seventeen-year follow-up of hypophosphatasia diagnosed in middle-aged siblings harboring a novel intronic and a rare missense ALPL gene mutation.

Hypophosphatasia (HPP) is the rare inborn-error-of-metabolism that features impaired mineralization of the skeleton and teeth due to a deactivating mutation or mutations of the gene ALPL which encodes the tissue-nonspecific isoenzyme of alkaline phosphatase (TNSALP). We report 17-year follow-up of twin sisters and a brother referred in middle-age for painful proximal femoral "stress fractures" and then diagnosed with HPP. They reported generalized muscle and bone pain, metatarsal fractures, arthropathy and, since childhood, tooth loss. Their concordant findings were explained by compound heterozygosity in ALPL for a rare maternal missense mutation (c.1403C&#xa0;>&#xa0;T, p.Ala468Val) in exon 12, together with a novel presumably paternal change (c.863-14G&#xa0;>&#xa0;A) predicting a cryptic mRNA splice site in intron 8. Fractures continued during follow-up until one sister received a three-and-one-half-year course of hydroxyapatite-targeted TNSALP supplementation therapy (asfotase alfa) during which substantial improvement occurred in her clinical, biochemical, and functional parameters as well as quality of life. Following subsequent unplanned treatment cessation she suffered significant clinical deterioration, including new fractures and loss of mobility. Her bone histopathology documented osteomalacia. Treatment resumption restored its benefits. Among ten asymptomatic family members evaluated in this four-generation kindred, eight were carriers heterozygous for either ALPL mutation. Those harboring the maternal missense defect manifested mild hypophosphatasemia, suggesting a dominant-negative mutation effect. This experience underscores the importance of in-depth phenotyping and then clinical follow-up to characterize ALPL variant combinations, and for maintaining effective asfotase alfa treatment.

Humans

Effectiveness of high-power laser use in the removal of esthetic restorations: a systematic review.

This systematic review aimed to evaluate the effectiveness of high-power lasers in the removal of esthetic restorations compared with conventional methods. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and registered in PROSPERO (registration number: CRD420251055736). A comprehensive electronic search was performed in MEDLINE, Scopus, Embase, Web of Science, and the Cochrane Library. Study selection, data extraction, and methodological quality assessment were independently performed by four reviewers using QUIN tool for in vitro studies. A total of 2.384 records were identified, of which 19 in vitro studies conducted on extracted human permanent teeth met the eligibility criteria and were included in the qualitative synthesis. The included studies evaluated different high-power laser systems, predominantly Er: YAG and Er, Cr: YSGG lasers, as well as CO&#x2082; lasers. Five studies were classified as high quality, whereas the remaining fourteen studies were classified as moderate quality. Available laboratory evidence suggests that laser-assisted techniques may represent a potential alternative approach for removing esthetic restorations, with advantages including conservative tissue removal, reduced damage to underlying tooth structures, and intrapulpal temperature increases within acceptable limits. The Er: YAG laser was the most frequently investigated system, with power settings ranging from 1.5 to 5.9&#xa0;W, showing particularly favorable laboratorial performance in the removal of lithium disilicate restorations, especially in thinner substrates. Within the limitations of the available evidence, high-power lasers appear to be a promising and minimally invasive alternative to conventional methods for the removal of esthetic restorations. However, the predominance of in vitro studies highlights the need for well-designed clinical trials to confirm these findings and support their clinical application.

Humans

Home-Based Cardiac Rehabilitation Using a Smart Ring and Telephone Counselling: A Randomized Controlled Trial.

BACKGROUND: Home-based cardiac rehabilitation (HB-CR) is a promising alternative to center-based cardiac rehabilitation as it can address several barriers impeding CR implementation because of its enhanced accessibility. However, to date, HB-CR has not garnered adequate attention due to a lack of communication between patients and medical staff. In this study, we aimed to investigate the effectiveness of HB-CR by monitoring the pulse rate (PR) using a smart ring equipped with photoplethysmography. METHODS: Patients with cardiovascular disease were educated on structured HB-CR methods following a symptom-limited cardiopulmonary exercise test (CPET), and were instructed to wear the device during the exercise session. The recorded PR was uploaded to a website via a smartphone and monitored by medical staff. Patients were randomly assigned to one of two groups: intervention or control group. The intervention group received weekly telephone counselling and was encouraged to maintain optimal levels of physical activity. In contrast, the control group only recorded their exercise data without additional interventions. After 3 months of training, the CPET was performed. RESULTS: Among the 64 randomized patients (32 in each group), an intention-to-treat analysis showed that peak oxygen consumption increased over time in both the groups, with a significantly greater improvement in the intervention group. The group-by-time interaction for peak oxygen consumption was statistically significant (estimated mean difference, 2.0 mL/kg/min; 95% confidence interval, 0.7-3.3; P = 0.004). CONCLUSION: HB-CR using a smart device was effective in improving oxygen consumption. However, appropriate monitoring and timely counselling by medical professionals are important for improved outcomes. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0005893.

Humans

Impact of neoprene wetsuits on lung volumes and work of breathing: implications for military diver safety and performance.

INTRODUCTION: Neoprene wetsuits may impose mechanical constraints on the chest wall, potentially altering respiratory function. This study investigated the impact of neoprene wetsuits on lung volumes, airway mechanics, and work of breathing (WOB) in healthy male divers. METHODS: A randomised crossover trial was conducted with 31 male divers at the Royal Netherlands Navy Diving Medical Centre. Participants underwent pulmonary function testing, including spirometry, body plethysmography, the forced oscillation technique (FOT), and diffusion capacity measurements, both with and without a hoodless standardised 5 mm neoprene full body wetsuit with a neoprene neck seal. Primary outcomes included changes in forced vital capacity (FVC), functional residual capacity (FRC), airway resistance (Raw), reactance (Xrs), and WOB. RESULTS: Wearing a neoprene wetsuit led to statistically significant reductions in FVC (2.8%, P < 0.05), forced expiration in one second (2.9%, P < 0.05), FRC (4.0%, P < 0.05), and expiratory reserve volume (10.9%, P < 0.05), alongside increases in inspiratory capacity and tidal volume. Raw increased significantly (P < 0.05), while the FOT revealed altered airway mechanics, evidenced by increased Xrs at multiple frequencies (P < 0.05). Diffusion capacity remained unchanged, suggesting preserved alveolar-capillary function. CONCLUSIONS: Neoprene wetsuits induce mechanically restrictive effects on the chest wall, reducing static and dynamic lung volumes and increasing WOB. While these changes may not be clinically relevant at rest, their impact needs to be determined during strenuous or prolonged dives, particularly when combined with other equipment that limits thorax excursions. Future research should explore the effects of the military 5 mm wetsuit under immersed conditions to better understand their operational impact on diver performance and safety.

Male

Effect of intraoperative 40-hz gamma-frequency auditory stimulation on postoperative delirium in older adults undergoing major surgery: a randomized clinical trial protocol.

INTRODUCTION: Postoperative delirium (POD) is a common and clinically significant complication among older adults undergoing major surgery under general anesthesia. Gamma-frequency (40-Hz) auditory stimulation has demonstrated potential neuroprotective and cognition-enhancing effects, suggesting a plausible role in perioperative delirium prevention. However, direct clinical evidence supporting intraoperative 40-Hz auditory stimulation in reducing POD remains limited, warranting rigorous evaluation in a randomized trial. PATIENTS AND METHODS: This prospective, parallel-group, randomized controlled trial will enroll 550 older adults scheduled for major noncardiac, nonneurosurgical surgery under general anesthesia. Participants will be randomized in a 1:1 ratio to either the active stimulation group, receiving intraoperative 40-Hz gamma-frequency auditory stimulation delivered via headphones for 2&#x2009;h following successful anesthesia induction, or the sham stimulation group, wearing headphones without active auditory output. The primary outcome is the incidence of POD on postoperative day 1 though 3, assessed using the Confusion Assessment Method (CAM) or the CAM for the ICU (CAM-ICU). Secondary outcomes include POD severity, sleep quality, pain scores, analgesic consumption, the incidence of postoperative nausea and vomiting (PONV), rescue antiemetic use, duration of post-anesthesia care unit (PACU) stay, length of hospital stay, quality of postoperative recovery, incidence of perioperative adverse events; postoperative morbidity, health-related quality of life, and all-cause 30-day mortality. DISCUSSION: This trial will determine whether intraoperative 40-Hz gamma-frequency auditory stimulation reduces the incidence of POD among older adults undergoing major surgery under general anesthesia. If efficacious, this noninvasive intervention could constitute a feasible perioperative strategy to mitigate delirium risk and enhance postoperative recovery. CLINICAL TRIAL REGISTRATION: Chinese Clinical Trial Registry (ChiCTR2500115156).

Humans

The effect of compression dressing on postoperative outcomes after upper eyelid blepharoplasty: a randomized, controlled, observer-blinded evaluation study.

PURPOSE: This study aimed to evaluate the impact of a compression dressing on postoperative pain, ocular surface changes, edema, ecchymosis, and aesthetic outcomes following upper eyelid blepharoplasty. METHODS: This observer-blinded, randomized, controlled trial included 112 eyelids from 56 patients who underwent bilateral upper eyelid blepharoplasty between June and August 2025. After surgery, one eyelid received a compression dressing (CD), while the other eyelid received no dressing (ND). Edema and ecchymosis were graded by masked observers on postoperative days 1, 7, 30, and 90. Aesthetic outcomes were evaluated using the Global Aesthetic Improvement Score. Pain was evaluated using a visual analog scale, and patient comfort was assessed by side preference. RESULTS: On postoperative day 1, ecchymosis scores were significantly lower in the CD group than in the ND group (unadjusted p = 0.002; Holm-adjusted p = 0.012). Edema scores were also lower on the CD side (unadjusted p = 0.012) and aesthetic scores were higher (unadjusted p = 0.046); however, neither difference remained statistically significant after Holm-Bonferroni correction for multiple comparisons (adjusted p = 0.060 and p = 0.138, respectively). No significant differences were observed in any parameter on postoperative days 7, 30, or 90 (all adjusted p > 0.05). Corneal staining scores were comparable between groups at all follow-ups, and no corneal erosions were observed. Pain scores on day 1 were similar (p = 0.977). CONCLUSIONS: Compression dressing after upper eyelid blepharoplasty was associated with a significant reduction in early postoperative ecchymosis, an effect that persisted after correction for multiple comparisons. Reductions in edema and improvements in aesthetic scores were observed on postoperative day 1 but did not remain statistically significant after adjustment. Overall, the benefits of compression dressing were limited in magnitude and transient, and routine use may not be necessary; its application should be individualized according to patient needs. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07701265 (retrospectively registered on July 8, 2026).

Humans

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

Multicenter randomized effectiveness/implementation trial of a digital self-management support tool to improve the quality of life during adjuvant hormonal therapy for patients with early breast cancer: The HOPE trial.

BACKGROUND: For patients with hormone receptor (HR) positive early breast cancer (BC), adjuvant endocrine therapy (ET) represents the cornerstone of treatment. However, 75% of patients experience ET-related symptoms that negatively affect their quality of life (QOL). Despite their high prevalence, these symptoms are often underestimated and under-addressed during consultations. As a result, non-adherence to ET is common and remains a major barrier for optimal disease and survival outcomes. METHODS: National, prospective, randomized, open-label hybrid type 1 effectiveness/implementation trial conducted in France comparing a personalized digital health pathway plus standard of care (SoC) vs. SoC alone in patients with HR+ early BC reporting ET-related symptoms. 180 patients will be randomized 1:1 to receive either 12&#xa0;weeks of the digital health pathway or 12&#xa0;weeks of SoC. The intervention is anchored by the Resilience&#xa9; digital companion including remote symptom and needs assessment, an introductory nurse-navigator phone call, and access to personalized, symptom-specific online educational and self-management programs (physical activity, yoga, meditation or cognitive behavioral therapy). In both arms, patients will be invited to wear a wearable device to objectively monitor behavioral parameters. The primary endpoint is the ET symptoms scale of the European Organization for Research and Treatment of Cancer (EORTC) QLQ-BR45 over 12-weeks. Secondary endpoints include other QOL domains, self-reported ET adherence, eHealth literacy, self-efficacy, and evaluation of the implementation process. DISCUSSION: This study should provide evidence on the effectiveness and real-world implementation of a personalized digital health pathway to improve QOL in patients experiencing ET-related symptoms. TRIAL REGISTRATION: ClinicalTrials.gov NCT06781996; Protocol version 3.0.

Humans

Efficacy and safety of deucravacitinib, an oral, selective tyrosine kinase 2 inhibitor, in patients with active psoriatic arthritis: 52-week results from the randomised, double-blind, placebo-controlled phase 3 POETYK PsA-1 trial.

OBJECTIVES: The randomised, double-blind, placebo-controlled, phase 3 Program fOr Evaluation of TYK2 inhibitor Psoriatic Arthritis-1 (POETYK PsA-1) trial evaluated the efficacy, safety, and tolerability of deucravacitinib, an oral, selective tyrosine kinase 2 inhibitor, in patients with PsA na&#xef;ve to biologic disease-modifying antirheumatic drugs. METHODS: Adults with active PsA, high-sensitivity C-reactive protein concentration &#x2265; 3 mg/L, and &#x2265; 1 PsA-related hand and/or foot erosion detectable via radiograph were randomised 1:1 to oral deucravacitinib 6 mg once daily or placebo through week (W) 16. At W16, patients continued receiving deucravacitinib or switched from placebo to deucravacitinib through W52. The primary endpoint was American College of Rheumatology 20% improvement in response (ACR20) at W16. Nonresponder imputation was used for missing data. Efficacy and safety were evaluated through W52. Post hoc rank analysis of covariance was used to evaluate structural damage with no missing data imputation. RESULTS: In 670 patients, a significantly greater proportion of those receiving deucravacitinib vs placebo achieved ACR20 at W16 (54.2% vs 34.1%, P < .001). Responses with deucravacitinib were increased at W52. Patients who switched from placebo to deucravacitinib achieved improvements similar to those in patients who received continuous deucravacitinib. Inhibition of structural damage was observed at W16 and W52. At W16, incidences of serious adverse events (AEs) (deucravacitinib, 1.8%; placebo, 2.4%) and discontinuations due to AEs (2.4%; 1.8%) were low and remained low through W52, without imbalances in cardiovascular events, malignancies, or opportunistic infections. No new safety signals were detected; no deaths occurred. CONCLUSIONS: Deucravacitinib demonstrated superiority vs placebo for clinical responses, patient-reported outcomes, and structural damage inhibition in patients with PsA, with favourable tolerability and safety.

Humans

The effect of drysuit diving in warm water on body temperature and post immersion orthostatic hypotension.

INTRODUCTION: Warm-water diving can limit heat dissipation, particularly when performed in fully encapsulating protective gear, leading to substantial thermal and cardiovascular strain that may impair diver safety. Following immersion, removal of hydrostatic support combined with heat-induced vasodilation may reduce central blood volume and increase susceptibility to orthostatic intolerance during egress and recovery. The extent to which this thermal strain impairs post-immersion orthostatic tolerance remains unknown. METHODS: Four randomised, crossover immersion trials were conducted at 28&#xb0;C, 33&#xb0;C, 38&#xb0;C without precooling (38&#xb0;C), and 38&#xb0;C with precooling (38&#xb0;C + Cool), with subjects wearing fully encapsulating dive gear. Subjects walked for up to 60 minutes at approximately 50% of O2max heart rate (HR) or until core temperature (Tc) reached 38.5&#xb0;C, or they voluntarily stopped. Tc, HR, and perceptual measures were recorded every 10 minutes. Orthostatic tolerance was assessed after immersion via a 70&#xb0; head-up tilt test. RESULTS: Eight healthy adults completed all aspects of the study. Tc and HR were higher during both 38&#xb0;C conditions compared with 28&#xb0;C and 33&#xb0;C (all P < 0.01) with no differences between 38&#xb0;C and 38&#xb0;C + Cool. Sweat loss exceeded 1.2 (SD 0.67) L&#x22c5;h-1 in both 38&#xb0;C conditions compared with &#x2264; 0.3 (0.32) L&#x22c5;h-1 at 28&#xb0;C and 33&#xb0;C (P < 0.01). Survival analysis showed orthostatic tolerance decreased with increasing thermal stress (log-rank P = 0.027; trend P = 0.003). Precooling did not reduce peak Tc or HR, nor did it improve tolerance time in 38&#xb0;C water. CONCLUSIONS: Encapsulated warm-water diving causes heat stress and cardiovascular strain that persists after immersion, impairing orthostatic tolerance. Precooling does not significantly reduce these outcomes.

Humans

Outcomes and Associated Prognostic Factors for Orthograde Canal Obturation Using Ortho MTA III: A Randomised Prospective Clinical Trial.

AIM: To prospectively compare treatment outcomes for orthograde canal obturation using Ortho MTA III (OMTA) with the continuous wave of compaction (CWC) using gutta-percha (GP) and AH Plus sealer, and to identify associated predictive factors. METHODOLOGY: Informed consent was obtained (110 patients), and single- or two-rooted permanent teeth (n&#x2009;=&#x2009;120) diagnosed with pulp necrosis (or previously treated) and asymptomatic apical periodontitis or chronic apical abscess (periapical index, PAI&#x2009;&#x2265;&#x2009;3) were randomly assigned to two groups (n&#x2009;=&#x2009;60/group). The canals were prepared to a minimal apical size #40 (ISO) based on their initial file size, disinfected and obturated by either CWC or OMTA using an enhanced disinfection protocol (GP disinfected, new gloves after each intraoperative radiograph and before starting obturation). Clinical and periapical radiographic examinations were conducted by two calibrated, independent endodontists during follow-up periods of at least 12&#x2009;months. Success rates and associated predictive factors (tooth-, operator- and patient-related) were analysed statistically using binary and multiple logistic regression (p&#x2009;<&#x2009;0.05). RESULTS: The median recall period was 30&#x2009;months (14-48&#x2009;months), and 104 teeth were finally analysed (recall rate: 86.67%). No significant differences in success rate were observed between the groups (p&#x2009;>&#x2009;0.05) under both loose (OMTA: 88.24%, CWC: 83.02%) and strict criteria (OMTA: 64.71%, CWC: 58.49%). Multivariate analysis revealed that age (OR&#x2009;=&#x2009;5.735, 95% CI: 1.286-25.577, p&#x2009;=&#x2009;0.022), periapical lesion size (OR&#x2009;=&#x2009;6.596, 95% CI: 1.397-31.138, p&#x2009;=&#x2009;0.017) and PAI score (OR&#x2009;=&#x2009;2.081, 95% CI: 1.047-4.136, p&#x2009;=&#x2009;0.036) were significant predictors of treatment failure. CONCLUSIONS: Orthograde obturation of infected canals with Ortho MTA III demonstrated comparable success and treatment outcomes to those filled with GP and sealer by CWC, supporting its potential as a clinically viable alternative for the obturation of infected root canals. TRIAL REGISTRATION: cris.nih.go.kr registration number: KCT00099939.

Humans

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I&#xb2; statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R&#xb2;=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Humans