Search PubMedSearch

SEARCH · Search PubMed

Results for “Psychomotor Performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

730 records · Page 2Linked to original sources

Re-evaluating pediatric laryngoscope blade size recommendations: Comparable intubation performance across blade sizes in pediatric manikin models.

BACKGROUND: Pediatric airway management traditionally emphasizes strict adherence to age-based laryngoscope blade size recommendations, despite limited empirical validation. OBJECTIVES: To evaluate whether intubation performance varies across a range of blade sizes, and whether a Macintosh 2 blade performs comparably across multiple pediatric age groups in a simulation setting. METHODS: We conducted a randomized crossover simulation study using three pediatric airway manikins (neonate, infant, and child age groups). Emergency medicine residents and faculty physicians performed intubations using multiple laryngoscope blade types and sizes, including standard and nonstandard options. Primary outcomes were intubation time and first-attempt success. Secondary outcomes included complications and operator-rated ease of glottic view and tube passage. Between-blade differences were estimated with 95% confidence intervals. RESULTS: Across manikin sizes and blade types, intubation times were short and first-attempt success rates exceeded 98% in most conditions. Performance remained consistent even with blade sizes outside conventional age-based recommendations. Between-blade differences in intubation time were small, and complication rates were low across conditions. The Macintosh 2 blade performed comparably across all manikin sizes, with similar intubation times, high success rates, and favorable ease ratings. CONCLUSIONS: Intubation performance in pediatric manikin models was similar across a wide range of blade sizes. These hypothesis-generating findings warrant prospective clinical evaluation of simplified blade selection strategies for pediatric intubation.

Manikins

Malaria rapid diagnostic tests: performance, pitfalls, and progress.

PURPOSE OF REVIEW: Malaria rapid diagnostic tests (RDTs) have revolutionized malaria diagnosis in endemic settings. RDTs are simple to use and accurate for clinical cases, although sensitivity is reduced at parasite densities below 200 parasites/μl. However, increasing prevalence of hrp2/3 gene deletions in certain areas threaten utility of histidine-rich protein 2 (HRP2)-based RDTs, and lingering HRP2 antigenemia can generate false-positive results after parasite clearance. This review summarizes current performance of malaria RDTs, threats to their validity, and recent innovations to improve their performance and continued role in malaria diagnosis. RECENT FINDINGS: Most World Health Organization (WHO) prequalified RDTs perform well for clinical diagnosis, with only occasional exceptions, including a recently reported issue affecting several countries. RDT sensitivity is generally related to malaria transmission intensity, with higher proportions of false-negative results in lower-transmission areas. Newly prequalified lactate dehydrogenase (pLDH)-based RDTs perform well for both Plasmodium falciparum in areas with >5% hrp2/3 gene deletions and for Plasmodium vivax diagnosis. Several point-of-care alternatives to RDTs, including micro-fluidic devices, hemozoin-detecting devices, and automated hematology analyzers, have shown promising results in small studies, but require larger-scale trials before widespread use. SUMMARY: RDTs remain a critical tool in clinical diagnosis of malaria, and newer pLDH-based tests perform well in areas where hrp2/3 gene deletions threaten validity of HRP2-based RDTs.

Humans

Clinical Performance of Bulk-Fill Versus Incremental Composite Placement Approaches in Vital Posterior Teeth: A 24 Months Randomized Controlled Trial.

BACKGROUND: Composite resin placement technique may influence marginal integrity, polymerization stress distribution, and long-term clinical performance of posterior restorations. This randomized controlled clinical trial evaluated the 24-month clinical performance of four different placement techniques in Class I posterior composite restorations. METHODS: Fifty patients aged 20-35&#x2009;years presenting with four occlusal carious lesions each were enrolled, resulting in 200 restorations. Cavities (4-5&#x2009;mm depth) were prepared according to caries extension. Restorations were randomly allocated into four equal groups (n&#x2009;=&#x2009;50) according to placement technique: stamp technique, snowplow technique, modified incremental "pizza" technique, and bulk-fill technique. All materials were applied following manufacturers' instructions. Clinical evaluation was performed at baseline and after 6, 12, and 24&#x2009;months using FDI criteria. Functional (fracture/retention, marginal adaptation), esthetic (marginal staining, anatomical form), and biological (postoperative sensitivity, secondary caries) properties were assessed by two calibrated evaluators. Statistical analysis was performed at a significance level of &#x3b1;&#x2009;=&#x2009;0.05. RESULTS: Thirty-eight patients with a total of 152 restorations were evaluated at the end of the 24&#x2009;months in line with FDI at the end of the study with 76% recall rates. No statistically significant differences were observed among groups regarding fracture/retention or secondary caries (p&#x2009;>&#x2009;0.05). Marginal adaptation and marginal staining demonstrated minor deterioration over time across all groups, with statistically significant intergroup differences found (p&#x2009;<&#x2009;0.05). Postoperative sensitivity was minimal and transient in all groups with no significant difference (p&#x2009;=&#x2009;0.181). CONCLUSIONS: Within the limitations of this 24-month follow-up, the four placement techniques demonstrated comparable clinical performance in Class I posterior composite restorations. Selection of technique may therefore be guided by clinical preference and procedural efficiency rather than differences in short-term clinical outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07415317.

Humans

Effects of Hydrogen-Rich Water Supplementation on Exercise Performance, Autonomic Nervous System Recovery, and Blood Lactate Concentration During Repeated Sprint Exercise in Male University Athletes.

Hydrogen-rich water (HRW) supplementation has been proposed to exert anti-fatigue effects during exercise; however, its impact on exercise performance and autonomic nervous system (ANS) function during repeated sprinting remains unclear. The aim of this study was to examine the effects of acute pre-exercise HRW ingestion on repeated sprint performance, ANS regulation, and blood lactate concentration. This randomized, single-blind, placebo-controlled crossover study included 13 male university athletes (23.9 &#xb1; 2.0 years). Each participant completed two sessions of 7&#xd7;6-second all-out cycling sprints interspersed with 30-second recovery intervals, with a one-week washout period between sessions. Critical flicker fusion frequency, heart rate, heart rate variability (HRV), and blood lactate were assessed at baseline, during exercise, and at 0-5 min and 10 min post-exercise. Compared to the placebo trial, the HRW trial demonstrated significantly higher average power output (d = 0.61) and significantly lower total work decrement and fatigue index (d = 0.62; d = 0.64). Post-exercise HRV recovery was significantly accelerated in the HRW trial, including RMSSD (d = 0.62), LF/HF ratio (d = 0.82), SampEn (d = 0.79), and DFA&#x3b1;1 (d = 0.79). Blood lactate at 3 min post-exercise was approximately 1 mmol/L lower in the HRW trial (d = 0.64). These findings suggest that acute HRW ingestion attenuates the decline in power output, accelerates ANS recovery, and enhances lactate clearance following repeated sprint exercise.

Humans

Creatine formulations and repeated sprint training: effects on physical and physiological adaptations in soccer players during the short-term preparation phase.

BACKGROUND: This research examined the impact of various creatine (Cr) supplementation formulations during a 4-week preparatory phase on the efficacy of repeated sprint training (RST) and on improvements in physical and physiological performance in male soccer athletes. METHODS: A total of forty collegiate young soccer players volunteered for the study. They were randomly divided into four groups: creatine monohydrate (Cr-Mon, n&#x2009;=&#x2009;10), creatine ethyl ester (Cr-Ee, n&#x2009;=&#x2009;10), creatine hydrochloride (Cr-Hcl, n&#x2009;=&#x2009;10), and placebo (PL, n&#x2009;=&#x2009;10). All athletes engaged in a 4-week training intervention, three times a week (i.e. 12 sessions), and physical (countermovement vertical jump [CMVJ], 20-m sprint, and L-run) and physiological (Wingate anaerobic power and incremental exercise tests) performance were assessed both before and after the training period. RESULTS: All training groups improved physical and physiological performance following the 4-week intervention period (p&#x2009;<&#x2009;0.05). Additionally, the groups receiving the Cr supplement exhibited significantly greater changes (p&#x2009;=&#x2009;0.001) in physical performance, peak power output, and fatigue index compared to the PL group. However, no significant differences were found among the groups regarding mean power output and VO2max. Notably, the Ee and Hcl forms of Cr showed superior gains (p&#x2009;<&#x2009;0.05) in physical performance and peak power compared to the Mon form after the 4-week intervention. CONCLUSIONS: The results underscore the importance of Cr ingestion in enhancing adaptations for short-term physical performance tasks, highlighting the effectiveness of the Ee and Hcl forms in further improving the CMVJ, 20-m sprint, L-run, and peak power among soccer players during the short-term preparation phase.

Humans

Apoptosis protein markers in comorbid type 2 diabetes mellitus and depression; relationships with cognitive performance, incident dementia, and white matter hyperintensities.

Type 2 diabetes mellitus (T2DM) and major depressive disorder (MDD) are reciprocal risk factors, and both elevate dementia risk. Dysregulation of programmed cell death is implicated in T2DM, MDD, and neurodegeneration, but proteomic markers of apoptosis have yet to be studied as dementia predictors in people with T2DM and/or MDD. This study examines apoptosis markers in comorbid T2DM and MDD, and their associations with cognitive, dementia, and neuroimaging outcomes. The retrospective sample (n&#xa0;=&#xa0;15,765) consisted of UK Biobank participants (MDD only n&#xa0;=&#xa0;1230; T2DM only n&#xa0;=&#xa0;3644; comorbid T2DM&#xa0;+&#xa0;MDD n&#xa0;=&#xa0;721). Individuals with T2DM&#xa0;+&#xa0;MDD comorbidity had poorer cognitive performance, and a higher 15-year dementia incidence (HR&#xa0;=&#xa0;4.44, 95% CI&#xa0;=&#xa0;[3.23,6.11]). Among 60 apoptosis-related proteins identified by Kyoto Encyclopedia of Genes and Genomes pathway enrichment, 41 were significantly up-regulated in comorbid T2DM&#xa0;+&#xa0;MDD relative to controls, and 4 were higher in the comorbid group than both T2DM alone and MDD alone. Tumor necrosis factor ligand superfamily member 10 (TNFSF10), growth arrest and DNA damage-inducible protein GADD45 beta, tumor necrosis factor ligand superfamily member 6, and RAC-gamma serine/threonine-protein kinase were associated with dementia risk. Nine proteins (e.g. apoptosis-inducing factor 1, mitochondrial, caspase-2, mitogen-activated protein kinase kinase kinase 5, TNFSF10), were associated with white matter hyperintensity volumes in comorbid T2DM&#xa0;+&#xa0;MDD after FDR correction, but none were associated with cognitive performance, atrophy, or white matter microstructural changes. These findings identify peripheral apoptosis markers that were further elevated in comorbid T2DM&#xa0;+&#xa0;MDD compared to either alone, pointing to an important pathophysiological element underlying adverse outcomes in the context of mood and metabolic comorbidity.

Humans

A study on the differences in recovery effects of different types of nutritional supplements on competitive performance of esports athletes under mental fatigue.

BACKGROUND: To compare the effects of different nutritional supplements on the recovery of core competitive performance abilities in esports athletes following mental fatigue and to observe changes in the autonomic nervous system during recovery after nutritional supplementation by monitoring heart rate variability (HRV). METHODS: A randomized crossover within-subject controlled experimental design was adopted, including nutritional supplement type (caffeine, nitrate, Ginkgo biloba extract, catechins, placebo)&#x2009;&#xd7;&#x2009;mental fatigue state (initial, fatigued, post-supplementation). Twenty high-level first-person shooter (FPS) esports athletes were recruited. Mental fatigue was induced using a Stroop task. After ingesting the different supplements and resting for 60&#x2009;minutes, the participants completed assessments of shooting accuracy, shooting stability, spatial localization, and multitasking ability using the KovaaK's simulation trainer. HRV indices were also recorded to evaluate changes in autonomic regulation. RESULTS: For shooting accuracy, compared with the placebo condition, all four supplements significantly improved shooting accuracy scores following mental fatigue (all p&#x2009;<&#x2009;0.05); however, no significant differences were observed among the effects of the different supplements. For shooting stability, caffeine, nitrate, and catechins produced significant recovery effects on shooting stability (all p&#x2009; <&#x2009;0.05); however, no significant differences were observed among the effects of these three supplements. For spatial localization and multitasking ability, the improvements in these two abilities in the post-supplementation state may have resulted from natural recovery, and none of the four nutritional supplements demonstrated a significant recovery effect. The HRV results showed that indices including RMSSD and SDNN changed under some supplement conditions. CONCLUSIONS: Mental fatigue significantly reduced the competitive performance of esports athletes. Four types of nutritional supplements all promoted the recovery of shooting accuracy, while caffeine, nitrate, and catechins promoted the recovery of shooting stability. However, no additional recovery advantages of the nutritional supplements over placebo were identified for spatial localization or multitasking ability. Changes in HRV may reflect changes in autonomic regulation during recovery, but further research is still warranted.

Humans

Effects of acute resistance exercise on prefrontal oxygenation and task-switching performance: Considerations of loading strategies and blood flow restriction.

Although acute resistance exercise (RE) has been proposed to influence cognitive flexibility and underlying neural mechanisms, it remains unclear whether these effects vary across loading strategies and whether exercise-induced prefrontal hemodynamic responses translate into cognitive outcomes. The present study examined (1) prefrontal cortex (PFC) oxygenated hemoglobin (O2Hb) responses across exercise sets and conditions, (2) the effects of low-load (LL), LL with blood flow restriction (BFR), and high-load (HL) RE on task-switching performance, and (3) whether exercise-related PFC O2Hb responses were associated with pre- to post-exercise changes in task-switching performance. Thirty physically active adults completed three randomized, counterbalanced RE conditions consisting of four sets of barbell squats. LL was performed at 30% one-repetition maximum (1RM) with and without BFR, whereas HL was performed at 70% 1RM. Cognitive flexibility was assessed pre- and post-exercise using a modified Stroop task, indexed by switch-cost reaction time (RT) and accuracy. PFC O2Hb was assessed using functional near-infrared spectroscopy during exercise and expressed as changes from the resting baseline for each set (Sets 1-4). PFC O2Hb increased across sets, rising from Set 1 to Set 3 before plateauing, with no differences observed across conditions. Switch cost RT and accuracy did not improve from pre- to post-exercise, and no differences across conditions were detected. PFC O2Hb during the final set was not associated with changes in switch cost. These findings suggest that although acute RE elicits robust increases in prefrontal hemodynamic activity, such responses may not translate into acute improvements in cognitive flexibility.

Humans

Clinical performance evaluation of single-shade versus multi-shade composite resins in non-carious cervical lesions: a 36-month randomized clinical trial.

BACKGROUND: Composite resins are widely used as the material of choice for definitive restorations due to their ability to integrate functional and aesthetic aspects in dental rehabilitation. Recently, one-shade composite resins have been introduced to simplify the clinical workflow. OBJECTIVES: This study aimed to compare the clinical performance of a "chameleon effect" composite resin with that of a multi-shade composite resin in non-carious cervical lesions after 36 months of follow-up. METHODS: This study was a randomized, controlled, double-blind clinical trial with an equivalence design using a split-mouth approach. The sample consisted of 60 patients presenting at least two non-carious cervical lesions, totaling 120 restorations. Restorations were performed using two materials from the same commercial brand: Vittra Unique (one-shade group) and Vittra APS (multi-shade group). The clinical performance of the restorations was longitudinally evaluated according to the FDI criteria. Survival analysis was performed using Kaplan-Meier curves and the log-rank test, while other clinical parameters were compared using the chi-square test (&#x3b1; = 0.05). RESULTS: At baseline, no statistically significant differences were observed between the groups regarding the evaluated biological, functional, and aesthetic parameters (p > 0.05). Both materials demonstrated clinically acceptable performance according to the FDI criteria, with no significant differences between them. CONCLUSIONS: After 36 months, no significant differences were observed between the one-shade and the multi-shade composite resins in the restoration of non-carious cervical lesions. CLINICAL SIGNIFICANCE: This 36-month randomized clinical trial demonstrates that single-shade composite resins achieve structural durability and aesthetic integration equivalent to traditional multi-shade layering when restoring non-carious cervical lesions. This evidence validates a simplified, single-shade restorative workflow, significantly reducing chairside time and operator-dependent variables without compromising the clinical longevity.

Humans

Nondominant Hand Training in Laparoscopy for Surgical Interns: Feasibility and Impact.

OBJECTIVE: Laparoscopy requires bimanual proficiency, yet early trainees demonstrate underdeveloped nondominant hand (NDH) performance. Although deliberate practice of NDH skill contributes to overall performance, NDH training is rarely incorporated into residency simulation curricula and has not been formally evaluated in surgical trainees. We assessed feasibility and impact of integrating structured NDH training with established laparoscopic curriculum for surgery interns. DESIGN: Prospective, single-institution randomized pilot study. Interns were assigned the standard 4-week curriculum of laparoscopic dominant hand and bimanual tasks (Control) or completed assigned NDH tasks in addition to the standard curriculum (Intervention). Feasibility was determined by assigned task completion, daily standard and NDH-specific self-reported practice time, and improvement in bimanual task performance. Performance was video recorded weekly and assessed by blinded evaluators using MISTELS and GOALS scoring. Cognitive workload during laparoscopic tasks was measured via NASA-TLX. Exploratory analyses were conducted within a Bayesian framework. SETTING: A single academic institution with a surgical simulation training program. PARTICIPANTS: General surgery interns on their 4-week simulation rotation. RESULTS: Eleven general surgery interns (6 intervention, 5 controls; all right-hand dominant) completed the study with 100% task completion and practice log compliance. Both groups improved in bimanual performance and perceived cognitive load. Reduction in cognitive workload during bimanual task performance was greater in the NDH group. Time spent on NDH practice over 4 weeks was associated with improved bimanual performance, independent of time spent on standard curriculum tasks. CONCLUSIONS: Structured NDH training is feasible to implement within an existing curriculum and reduces perceived cognitive workload during bimanual laparoscopic tasks. NDH practice demonstrates a beneficial dose-response relationship with performance, supporting its integration into early laparoscopic training.

Laparoscopy

Systematic review of microorganism disinfection performance by chemical and ultraviolet light water treatment methods.

Safe drinking water is critical for public health, yet microbial contamination remains a significant global challenge. We conducted a systematic review to update World Health Organization guidance on water disinfection technologies by synthesizing peer-reviewed literature from 1997 to 2021 on the performance of free chlorine, chlorine dioxide, ozone, and ultraviolet (UV) light against bacteria, viruses, and protozoa. Following PRISMA guidelines, we analyzed log10 reduction values (LRVs) and contact times (Ct) or fluence (for UV) from laboratory and field studies. We included studies from multiple databases and expert-recommended studies. Results show mean Cts for 2 LRV of non-opportunistic bacteria as 6.0 (free chlorine), 0.4 (chlorine dioxide), and 1.2 (ozone) mg/L*min, and a mean UV fluence of 8.2 mJ/cm&#xb2; (all bacteria). Viruses required lower Cts, except for UV-resistant adenoviruses, while protozoa required higher Cts or fluences. Opportunistic bacteria required significantly higher Cts than non-opportunistic bacteria for free chlorine and chlorine dioxide. Temperature and pH effects were inconsistent, highlighting data variability and gaps in field studies. These findings support global guidance on water treatment and may be used alongside other context-specific data to understand the roles these technologies play in reducing waterborne exposures. We recommend standardized reporting from performance studies to enable straightforward synthesis of evidence.

Disinfection

Effects of carbohydrate mouth rinse on psychophysiological responses, kinematic variables and technical actions during small-sided soccer games.

BACKGROUND: This study investigated the effects of carbohydrate mouth rinsing (CHOMR) on various psychophysiological, kinematic, and technical actions during 4-a-side small-sided soccer games (SSGs). METHODS: In a randomized, crossover, double-blind design, 16 young male soccer players (age: 15&#x2009;&#xb1;&#x2009;1 years; height: 172.6&#x2009;&#xb1;&#x2009;7.0&#x2009;cm; body mass: 57.8&#x2009;&#xb1;&#x2009;7.9 kg) participated in two 4-a-side SSGs separated by one week following either CHOMR or placebo (PLA). During each SSGs, heart rate (HRmean, %HR, and HRmax), rating of perceived exertion (RPE), enjoyment, visual analogue scale (VAS) to perceived mental fatigue, mood states, total distance (TD), high-speed running distance (HSRD), average metabolic power (AMP), high metabolic load distance (HMLD), sprint distance (SD), acceleration (ACC), deceleration (DEC), and technical actions (e.g. passing, tackling, shooting, and interceptions) were assessed. RESULTS: Compared with PLA, CHOMR resulted in significantly higher RPE (p&#x2009;=&#x2009;0.025, g&#x2009;=&#x2009;0.86) and significantly lower VAS scores (p&#x2009;=&#x2009;0.010, g&#x2009;=&#x2009;-0.71). In addition, the CHOMR condition showed significantly higher values for interceptions, successful tackles, unsuccessful tackles, unsuccessful shots, and goals (p&#x2009;<&#x2009;0.05, g&#x2009;=&#x2009;0.96-2.02), whereas block values were significantly higher in the PLA condition. There were no statistically significant differences in HRmean, %HR, HRmax, enjoyment, TD, HSRD, AMP, HMLD, SD, ACC, DEC, successful passes, unsuccessful passes, successful shots, or mood states between the conditions (p&#x2009;>&#x2009;0.05). CONCLUSION: The current study findings suggest that CHOMR may enhance selected technical actions and lower VAS scores during 4-a-side SSGs, although it was also associated with higher RPE and did not alter the kinematic responses. In conclusion, CHOMR was associated with higher RPE, lower mental fatigue, and selective improvements in technical actions, with no significant effects on kinematic variables or HR.

Humans

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

Diagnostic performance of machine learning models for malignant and non-malignant pleural effusion: Systematic review and meta-analysis.

BACKGROUND: Accurately distinguishing malignant pleural effusion (MPE) from non-malignant pleural effusion is clinically important, but the generalisability and methodological quality of machine-learning (ML) models remain uncertain. METHODS: We searched eight databases to 23 April 2026. Diagnostic performance was pooled using random-effects and Reitsma bivariate models, and study quality was assessed using PROBAST+AI. RESULTS: Forty-two studies were included; 17 contributed to the AUC meta-analysis and 14 to the bivariate analysis. The pooled AUC was 0.90 (95&#xa0;% CI 0.85-0.94; 95&#xa0;% prediction interval 0.62-0.98), with sensitivity of 0.80 (95&#xa0;% CI 0.77-0.83) and specificity of 0.87 (95&#xa0;% CI 0.79-0.92). Only nine studies reported external, temporal or independent validation. Externally validated studies had a lower pooled AUC than studies without external validation (0.83 vs 0.92), with lower specificity observed in the two externally validated studies contributing sensitivity and specificity data. All 42 development assessments had high overall quality concerns, and all 42 model evaluations were judged at high risk of bias. CONCLUSIONS: ML models showed good apparent accuracy for distinguishing MPE from non-MPE, but the evidence was limited by substantial heterogeneity, high risk of bias and scarce external validation. The pooled estimates reflect the average performance of different selected models rather than the expected accuracy of a single clinical test. ML models should be regarded as adjuncts to existing diagnostic pathways until they are confirmed by rigorous multicentre prospective external validation and clinical-impact studies.

Humans

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Performance of Automated Hematology Analyzer Criteria in Detecting Peripheral Blood Smear Abnormalities: A Systematic Literature Review.

OBJECTIVES: Criteria for visual examination of stained peripheral blood smear (PBS) differ among institutions in the United States and internationally. In an effort to standardize review criteria, the International Consensus Group for Hematology Review (ICGHR) proposed in 2005 a consensus list of rules for CBC findings that should trigger a review of automated cell counter results and potentially lead to further testing or blood smear review. The primary aim of this paper is to report on the published literature in the past 20&#x2009;years regarding PBS review criteria and their ability to identify relevant peripheral blood abnormalities. METHODS: We performed a systematic review of the published literature from 2005 to 2025 to investigate and summarize PBS review criteria and performance in the context of automated hematology analyzers in clinical laboratories. RESULTS: Of 5351 citations, 68 studies met our search criteria. These studies included 22 countries and all major hematology analyzer manufacturers. Marked variability was observed in study populations, analyzer flagging criteria, details of PBS visual review, definitions of a "positive" smear, and approaches to statistical data analysis. Across studies, the blast flag sensitivity ranged from 18% to 100% while the blast flag specificity ranged from 17% to 100%. Wide ranges in sensitivity/specificity were also seen for atypical and/or abnormal lymphocyte flags across studies. For studies analyzing the same patient population, less striking variation was seen across instruments. CONCLUSIONS: This systematic review provides a 20-year overview of the literature, highlighting significant variability in PBS review criteria, dependence on study design and hematology analyzer, and the importance of developing harmonized evidence-based guidelines.

Humans

External load metrics and monitoring in women's football match play: A systematic review.

This systematic review aimed to identify the most commonly used variables for monitoring external load during elite women's football matches and to compare reporting practices internationally and in Brazil. Searches were conducted in Web of Science, PubMed, and SciELO using the PICOS framework between February and March 2026, resulting in the inclusion of 35 studies. The main outcomes analysed were total distance covered (TD), distance covered across speed zones (HSR, VHSR, sprint), number of accelerations and decelerations, and maximum speed. TD and distance covered across speed zones were the most frequently reported indicators (94.3%), followed by HSR (82.8%) and sprint distance (68.5%). Considerable variability was observed in the classification of speed zones and thresholds used to define accelerations and decelerations, limiting comparisons between studies. External load values varied according to playing position and competition level, with international matches generally imposing greater demands than national competitions. Brazilian research remains limited and demonstrates notable methodological variability. This review proposes standardised speed and acceleration/deceleration thresholds based on the most recurrent ranges reported in the literature, supporting improved consistency in monitoring practices across elite women's football contexts.

Humans