Search PubMedSearch

SEARCH · Search PubMed

Results for “Implant-supported prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,017 records · Page 2Linked to original sources

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n  = 627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Humans

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y₂O₃ partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p ≤ 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Influence of endodontic access on the fracture resistance, retention and microleakage of full-coverage restorations in vitro: A systematic review and meta-analysis.

BACKGROUND: Endodontic access through retained full-coverage restorations (FCRs) is a preferred option for patients because of its high cost-effectiveness. However, the clinical performance of FCRs after repaired access cavity remains insufficiently characterized. This systematic review investigates the effects of endodontic access cavity preparation through retained FCRs on fracture resistance, retention, and microleakage based on in vitro studies. METHODS: A comprehensive search was performed in PubMed, Web of Science, and Scopus databases. Studies investigating the influence of endodontic access on the fracture resistance, retention, and microleakage of FCRs were included. Two independent reviewers conducted study selection, data extraction, and risk-of-bias assessment using the QUIN tool. Meta-analysis was employed to estimate fracture resistance and retention, with sensitivity analysis and subgroup evaluation also performed. Microleakage was summarized qualitatively. RESULTS: Twentythree studies were included: fracture resistance (n = 15), retention (n = 5), and microleakage (n = 3). Endodontic access significantly reduced fracture resistance for zirconia (p = 0.0002) and lithium disilicate (LD) restorations (p = 0.007), but not for resin-matrix ceramic (RMC) restorations (p = 0.25). Abutment tooth type contributed to heterogeneity within the LD and RMC subgroups. Retention was significantly reduced when access cavities were left unrepaired (p = 0.03), whereas appropriate repair protocols restored or enhanced retention relative to baseline. Accelerated aging increased microleakage in retained FCRs. Surface pretreatments and flowable resin liners tended to reduce microleakage, but findings were inconsistent. CONCLUSIONS: Endodontic access significantly reduces fracture resistance of zirconia and LD FCRs, whereas RMC restorations show no significant change. Appropriate repair protocols can restore or improve retention, potentially exceeding original values. Limited evidence suggests that effective sealing is achievable with appropriate materials. However, well-designed and in-vivo researches are needed to provide more detailed clinical guidance. CLINICAL SIGNIFICANCE: When performing endodontic access through retained FCRs, reduced fracture resistance must be carefully considered for zirconia and LD restorations, while RMC restorations may be exempt from this concern. Loss of retention with access can be restored after repair. Surface pretreatment and flowable resin liners help decrease microleakage.

Humans

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 ± 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 ± 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 ± 4.45 vs 46.93 ± 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 ± 5.96 vs 39.27 ± 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 ± 0.507) compared with the laser group (0.07 ± 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 ± 0.19 vs 1.55 ± 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Autologous bone grafts versus alloplastic implants for orbital floor reconstruction: a systematic review and meta-analysis.

PURPOSE: The choice of reconstructive material for orbital floor fractures remains a subject of debate. While autologous bone has historically been considered the "gold standard," alloplastic implants offer potential advantages in reducing surgical morbidity. This meta-analysis aimed to compare the safety and efficacy of autologous bone grafts versus alloplastic implants in orbital floor reconstruction. METHODS: A systematic review was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251140583). Electronic databases (PubMed, Scopus, Web of Science, Cochrane Library) were searched from inception to August 2025. Randomized controlled trials and comparative cohort studies evaluating functional outcomes (diplopia, enophthalmos) and complications (ectropion, infection, malposition) were included. Data were synthesized using a random-effects model, with risk ratios (RR) and 95% confidence intervals (CI) calculated. RESULTS: Twenty studies comprising 2,119 patients were included. Alloplastic implants demonstrated statistically significant superiority in periocular safety, with a reduced risk of postoperative ectropion compared to autologous grafts (RR = 2.245; p = 0.020). In an exploratory sensitivity analysis excluding one outlier study, autologous grafts were associated with a significantly higher risk of implant malposition (RR = 2.074; p = 0.004). Autologous reconstruction was associated with a strong trend toward increased postoperative pain (p = 0.052) and inherent donor-site morbidity. No statistically significant differences were observed regarding infection (p = 0.402), enophthalmos (p = 0.201), or diplopia (p = 0.221). CONCLUSION: Alloplastic implants were associated with a lower risk of ectropion and implant malposition, with functional outcomes statistically comparable to autologous bone. Given the elimination of donor-site morbidity, alloplastic biomaterials represent a safe and effective alternative for orbital floor reconstruction; however, the predominance of retrospective, heterogeneous studies in the current evidence base means these findings should inform, rather than replace, individualized surgical decision-making pending further high-quality randomized trials.

Humans

The Soundtrack of Everyday Life: Real-world Music Listening Habits of Adult Cochlear Implant Users.

OBJECTIVE: Characterize real-world patterns of music listening and reward sensitivity among adult cochlear implant (CI) users compared with normal-hearing (NH) listeners. STUDY DESIGN: Cross-sectional observational study. SETTING: Online. PATIENTS: Adults (&#x2265;18&#xa0;y) with a CI or NH who used a music-streaming platform as their primary listening method. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Objective measures included platform-derived audio features (acousticness, danceability, energy, tempo, and valence), listening volume, unique-song ratio, and decade preferences. Self-reported measures included listening habits and the Barcelona Music Reward Questionnaire (BMRQ). Group comparisons used ANCOVAs and mixed-effect models adjusting for age and gender; within-CI analyses compared prelingual versus postlingual deafness. RESULTS: Among 16 CI users (69% male, 39.0&#xb1;15.6&#xa0;y) and 29 NH listeners (38% male, 32.2&#xb1;11.3&#xa0;y), CI users demonstrated a higher unique-song ratio (&#x3b2;=-0.157, CI as reference; 95%CI [-0.281, -0.034]; P =0.014) and stronger preference for older music (Pillai trace=0.537; F8,35 =5.07; P <0.001), adjusting for age. No significant group differences were observed in weekly listening time, listening volume, audio features, or BMRQ scores (total and subscores). Equivalence was confirmed for Emotion Evocation and Sensory-Motor subscales. There were no statistically significant differences in listening environments after Holm correction. No statistically detectable differences were observed between pre- and postlingually deafened CI users. CONCLUSIONS: Musically active CI users showed no significant differences in listening volume or overall music-reward sensitivity compared with NH peers, but demonstrated higher unique-song ratios and a bias toward older music. Findings highlight the value of ecologically valid data in understanding real-world music experiences among CI users.

Adult

Evaluation of intravenous sedation in dental implant surgeries: A prospective cohort study.

PURPOSE: This study aimed to evaluate the impact of intravenous sedation on patient-centered outcomes during implant and bone augmentation surgeries. METHOD: A prospective observational cohort study included 40 patients undergoing placement of &#x2265;3 implants, with or without bone augmentation. Patients underwent surgery under either intravenous sedation (n = 20) or local anesthesia alone (n = 20), according to routine clinical decision-making and patient preference. The sedation group received intravenous sedation with a multimodal regimen comprising remimazolam, dexmedetomidine, alfentanil, and low-dose esketamine, whereas the control group received local anesthesia only. Patient-reported outcome measures, hemodynamic parameters (SBP, DBP, HR, SpO2), postoperative pain (0-10 scale), and OHRQoL (OHIP-14) were recorded from baseline through 7 days post-surgery. RESULTS: Intravenous sedation was associated with significantly lower intraoperative pain (0.5 [IQR: 0&#x223c;2.75] vs. 3.25 &#xb1; 2.40, p = 0.003), anxiety (1 [IQR: 0&#x223c;2.75] vs. 4 [IQR: 3&#x223c;6], p = 0.001), and experienced discomfort (2 [IQR: 1&#x223c;3.75] vs. 4.15 &#xb1; 2.16, p = 0.016), and shortened perceived treatment duration (2.90 &#xb1; 2.34 vs. 5 [IQR: 4&#x223c;5], p = 0.020). Early postoperative pain was lower in the sedation group from Days 1-4 (p = 0.003-0.010). Hemodynamic parameters were more stable under sedation, with lower SBP (116.42 &#xb1; 13.32 vs. 144.11 &#xb1; 17.42 mmHg, p < 0.001), DBP (73.21 &#xb1; 10.28 vs. 82.37 &#xb1; 11.03 mmHg, p = 0.012), and HR (71.00 [IQR: 62.50&#x223c;79.25] vs. 85.00 &#xb1; 10.72 bpm, p = 0.021). OHRQoL scores favored the sedation group in swallowing, diet, malaise, and daily activities, particularly during the first three postoperative days (p=0.006-0.040). CONCLUSION: Intravenous sedation may enhance the patient experience during implant and/or bone augmentation procedures by reducing intraoperative pain and anxiety, improving hemodynamic stability, and promoting better early-postoperative recovery and OHRQoL. These findings suggest that intravenous sedation provides a safe and effective alternative for implant dentistry surgery, particularly for anxious or pain-sensitive individuals.

Humans

Influence of nicotine on protein expression around hydrophilic osseointegrated implants: A proteomic study in male rats.

OBJECTIVE: To ensure the success of dental implant treatment, various factors must be considered, including osseointegration and systemic conditions. There is evidence in the literature that smokers may exhibit alterations in tissue healing, which can compromise the success of implant rehabilitation. Therefore, this study aimed to investigate the influence of nicotine on the protein profile of bone tissue around hydrophilic implants during the osseointegration process in rats. DESIGN: Bone tissue samples from the control and nicotine groups (n&#x202f;=&#x202f;3 per group) were subjected to protein extraction, mass spectrometry, and bioinformatic analyses. Protein identification was performed using Proteome Discoverer 2.1 software and the SEQUEST algorithm, and the protein data were compared with those of a protein database of Rattus norvegicus obtained from UniProt. RESULTS: A total of 740 proteins were detected in both the control group and the nicotine-exposed group. Among them, the proteins biglycan, periostin and histone H4 were highlighted because of their higher abundance in the healthy implant group, while they were reduced in the nicotine-exposed group. CONCLUSIONS: Nicotine has the potential to alter the protein profile of bone tissue around hydrophilic implants during osseointegration, which may impair tissue remodeling and healing.

Animals

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Proteomic insights into the immunomodulatory effects of Ca/Sr co-doped sol-gel coatings for titanium implants.

Ionic functionalization of biomaterial coatings has emerged as a powerful strategy to regulate early host responses at the implant interface. However, how combined Ca/Sr incorporation governs the adsorbed proteome and downstream immune signaling remains poorly understood. This study analyses, employing in vitro tests and proteomics, the effect of adding Sr and Ca to Si-based coatings designed to bioactivate Ti implants. Hybrid Si-based coatings were synthesized by the sol-gel route with a fixed Ca content (0.5&#x202f;wt%) and increasing Sr contents (0.5, 1.0, 1.5&#x202f;wt%), and their physicochemical properties, ion release kinetics, and hydrolytic stability were characterized. The coatings remained highly crosslinked despite Ca/Sr incorporation, whereas the highest Sr content increased hydrolytic degradation to around 70% after 56 days. Proteomic analysis identified 183 adsorbed proteins, of which 56 were differentially adsorbed on Ca/Sr-coatings, mainly associated with immune and coagulation pathways. In vitro, RAW 264.7 showed increased gene expression of TNF-&#x3b1; and TGF-&#x3b2;; with an enhanced TNF-&#x3b1; secretion by the addition of Ca and Sr. In parallel, MC3T3-E1 indicated that Ca/Sr-coatings were not cytotoxic and did not impair cell proliferation. However, ALP activity was reduced in the co-doped groups, indicating that the immunomodulatory effects induced by Ca/Sr incorporation were not accompanied by enhanced early osteogenic differentiation. The Ca/Sr combination induced alterations in the adsorption of immune-related proteins, which correlated with the in vitro findings. The deeper insight into how Ca/Sr mixtures modulate protein adsorption on biomaterial surfaces may be key to understanding the immunomodulatory capacity of these bioactive cations.

Animals

Cochlear Implantation in Sickle Cell Disease: A Systematic Review of Feasibility and Outcomes.

INTRODUCTION: Sickle cell disease (SCD) is associated with systemic complications, including sensorineural hearing loss (SNHL) from microvascular occlusion and chronic inflammation. Although reports link SCD to higher rates of SNHL, current evidence is limited by small sample size, varied audiologic methods, and lack of standardized screening. This systematic review summarizes available literature on SNHL and cochlear implantation (CI) in SCD. METHODS: A literature search of PubMed MEDLINE, Embase, Scopus, Web of Science, and CINAHL identified 79 citations. After removal of duplicates, 35 records were screened in Rayyan. Studies published between January 1, 2000, and June 30, 2025, were eligible if they reported patients with SCD who developed hearing loss and underwent CI. Nine full texts were reviewed, and 4 met the inclusion criteria. Screening and review were performed independently by 2 authors per PRISMA guidelines. RESULTS: Across 4 case reports, a total of 5 patients with SCD underwent CI, ranging in age from 2 to 42 years. Four presented with bilateral severe-to-profound SNHL and one with unilateral loss. Implantation was technically feasible in all cases, including patients with cochlear fibrosis or ossification requiring modified insertion techniques. Postoperative outcomes were favorable: all patients demonstrated reliable device function and low impedances. Only 60% showed meaningful auditory benefit, characterized by improved functional speech perception in 2 patients (40%) and access to the speech frequency range with hearing testing going from moderate/profound hearing loss to mild hearing loss in 3 patients (60%). Complications occurred in 2 patients (40%): one developed unilateral middle ear infection leading to meningitis, and another experienced a postoperative pulmonary embolism requiring anticoagulation. The remaining 3 patients (60%) had uncomplicated recoveries with reported improved hearing from moderate/profound hearing loss to mild hearing loss post implantation. CONCLUSION: While CI appears feasible in SCD, our findings suggest that additional data are needed to assess its effectiveness in this patient population. However, evidence is limited to case reports, and complications such as thromboembolism and rapid cochlear fibrosis highlight the need for close perioperative management. More comprehensive studies with larger sample size are required to define surgical risk, optimize management, and establish best practices for timely implantation in this population.

Humans

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Soft Tissue Volume Augmentation at Single Implant Sites Applying Collagen Matrices or Connective Tissue Grafts: 10-Year Follow-Up of a Randomized Controlled Trial.

AIM: To compare up to 10&#x2009;years clinical, profilometric and patient-reported outcomes of implant sites previously augmented using a volume-stable collagen matrix (VCMX) or connective tissue graft (SCTG) in the aesthetic zone. METHODS: The original non-inferiority randomized controlled trial (RCT) enrolled 20 patients who received soft tissue volume augmentation with VCMX or SCTG at single implant sites. Clinical assessments and standardized measurements were performed at baseline after crown insertion and at 6&#x2009;months, 1, 3, 5, 7.5, and 10&#x2009;years. The primary outcome was mucosal thickness. Secondary outcomes included marginal bone levels (MBL), probing depth (PD), bleeding on probing (BOP), plaque control record, Pink Aesthetic Score (PES), OHIP-14 and buccal profilometric changes. Group comparisons were performed using mixed-effects and generalized estimating equation (GEE) models, which account for within-patient correlations due to repeated measurements and allow inclusion of all available data without requiring imputation for missing observations. RESULTS: Of the 20 originally enrolled patients, 10 (5 in the SCTG group and 5 in the VCMX group) were available for re-examination at 10&#x2009;years. The adjusted between-group difference in mucosal thickness was -0.02&#x2009;mm (95% CI -0.99 to 0.96). As the lower bound of the confidence interval remained above the prespecified non-inferiority margin of -1&#x2009;mm, non-inferiority of VCMX was shown. Buccal contour changes were comparable during the early follow-up, while a trend toward a greater long-term contour decrease was observed in group VCMX (-0.31&#x2009;mm [95% CI, -0.65 to 0.03]; p&#x2009;=&#x2009;0.07). Mean PES values were 10.6 in the SCTG group and 9.6 in the VCMX group, with no significant between-group differences (p&#x2009;=&#x2009;0.45). Both groups revealed high levels of oral health-related quality of life, with low median OHIP-14 scores (SCTG, 0.0; VCMX, 1.0; p&#x2009;=&#x2009;0.26). CONCLUSION: These preliminary long-term findings showed no clinically relevant differences between SCTG and VCMX in terms of clinical, profilometric and patient-reported outcomes. While SCTG remains the reference standard, VCMX represents a less invasive alternative but with a slight tendency toward greater long-term contour reduction. CLINICAL SIGNIFICANCE: Volume-stable collagen matrices serve as a viable alternative to autogenous connective tissue grafts for peri-implant soft tissue volume augmentation, particularly in patients seeking a reduced morbidity, without compromising long-term clinical or aesthetic outcomes. TRIAL REGISTRATION: German Clinical Trials Register: DRKS00017484.

Humans

Factors associated with periprosthetic joint infection following total knee arthroplasty: an updated systematic review and meta-analysis.

BACKGROUND: This study aimed to systematically evaluate factors associated with periprosthetic joint infection (PJI) following total knee arthroplasty (TKA), and thereby to provide evidence-based references for clinical prevention and perioperative risk stratification. METHODS: Computerized searches were conducted in the following databases from their inception until May 26, 2025: PubMed, Web of Science, Embase, the Cochrane Library, CINAHL, China National Knowledge Infrastructure, Wanfang Database, Chinese Scientific Journal Database, and Chinese Biomedical Literature Database. Two researchers independently screened the literature, extracted data, and assessed study quality. The methodological quality was assessed using the Newcastle-Ottawa Scale. Quantitative synthesis was performed when at least two studies reported comparable exposure definitions and sufficient comparator information; otherwise, narrative synthesis was used. Review Manager 5.4 software was used for the primary analysis. This study is registered on PROSPERO (CRD420251079339). RESULTS: A total of 25 observational studies were included in the qualitative synthesis, of which 24 contributed to the primary quantitative synthesis. Quantitatively pooled factors associated with PJI included male sex (OR&#xa0;=&#xa0;1.39, 95% CI 1.27-1.51), BMI &#x2265;30&#xa0;kg/m2 (OR&#xa0;=&#xa0;5.72, 95% CI 2.65-12.36), prolonged operative time, type 2 diabetes mellitus (OR&#xa0;=&#xa0;2.09, 95% CI 1.45-3.01), rheumatoid arthritis (OR&#xa0;=&#xa0;2.64, 95% CI 1.38-5.02), smoking (OR&#xa0;=&#xa0;1.65, 95% CI 1.34-2.04), blood transfusion (OR&#xa0;=&#xa0;2.27, 95% CI 1.59-3.25), American Society of Anesthesiologists score &#x2265;3 (OR&#xa0;=&#xa0;2.73, 95% CI 1.02-7.32), history of hormone therapy (OR&#xa0;=&#xa0;4.88, 95% CI 2.90-8.22), postoperative urinary tract infection (OR&#xa0;=&#xa0;3.59, 95% CI 1.15-11.21), intraoperative blood loss >200&#xa0;ml (OR&#xa0;=&#xa0;1.51, 95% CI 1.03-2.22), postoperative drainage tube placement duration &#x2265;24&#xa0;h (OR&#xa0;=&#xa0;2.23, 95% CI 1.50-3.32), preoperative anemia (OR&#xa0;=&#xa0;1.82, 95% CI 1.67-1.99), and combined pulmonary disease (OR&#xa0;=&#xa0;5.54, 95% CI 1.93-15.96). Age was narratively summarized because its classification differed substantially across studies. CONCLUSION: Multiple demographic, comorbidity-related, and perioperative factors were associated with PJI after TKA. However, because the included studies were observational and clinically heterogeneous, these findings should be interpreted as associations rather than causal effects. Optimization of modifiable factors may help reduce the burden of PJI, but further prospective studies using standardized PJI definitions and adjusted effect estimates are required.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

An Overview of Red Breast Syndrome: A Qualitative Systematic Review of the Literature and a Single-Center Case Series.

Red breast syndrome (RBS) is an uncommon inflammatory complication that may occur following implant-based breast reconstruction and can clinically mimic surgical-site infection. This qualitative systematic review, based on comprehensive PubMed and Scopus searches, summarizes the existing literature on RBS, focusing on its etiology, clinical presentation, diagnostic characteristics, and therapeutic approaches following breast reconstruction using acellular dermal matrices (ADMs). A management protocol is proposed based on available data, and a single-center case series is presented from our Hospital, including patients who developed RBS after direct-to-implant reconstruction with ADM between January 2022 and December 2024. Twenty-nine studies met the inclusion criteria, comprising case reports, case series, and retrospective or prospective cohort studies. The reported incidence of RBS ranged from 0% to 29.6%. Proposed etiologies include endotoxin contamination, residual cellular debris, delayed hypersensitivity reactions, and lymphatic or vascular impairment of mastectomy flaps. Most reports described localized erythema confined to the area of the ADM, with normal inflammatory markers and negative imaging findings, whereas antibiotic therapy frequently failed to achieve improvement. Corticosteroids represented the most consistently effective treatment, although some cases required ADM removal or replacement. In our institutional case series (n = 8), symptom onset occurred between 4 weeks and 7 months postsurgery. Inflammatory markers remained within normal limits, imaging rarely demonstrated fluid collections, and symptoms resolved within days to weeks with corticosteroid therapy or conservative management. This review consolidates current evidence, proposes a diagnostic-therapeutic algorithm and highlights the need for prospective investigations and manufacturer-level endotoxin testing to elucidate pathogenesis and optimize clinical management. Level of Evidence: 2 (Risk) For image description, please refer to the figure legend and surrounding text.

Humans

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3&#x2009;mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40&#x2009;mL, 2-3&#x2009;mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0&#x2009;mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans