Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Gloves, Protective”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

The effects of different materials of protective gloves on thermoregulatory responses.

The effects of two kinds of protecting gloves for pesticide spraying made of different materials on thermoregulatory responses during exercise were studied at ambient temperature of 28 degrees C and relative humidity of 60% in six healthy females, aged 19. One kind of gloves was made of polyurethane (A) and the other of Goretex (B) with cotton lining in each glove. Both kinds of gloves had almost the same volume. Main results of the experiment were summarised as follows: (1) during the exercise an increase of rectal temperature was inhibited more effectively in B than in A; (2) skin temperature of hand was significantly lower in B than in A; (3) absolute humidity and temperature inside the gloves were significantly lower during the period from the gripping bar exercise to the end of the experiment; (4) the number of contractions by the handgrip exercise performed immediately after the second turning of the screw was significantly smaller in A than in B. The findings presented suggest that the gloves made of Goretex material could reduce thermal strain during intermittent work in warm environmental conditions.

Adolescent↗

The value and limitations of protective gloves in medical health service: Part III.

The value of protective gloves in the health care environment is well known. However, these gloves are not perfect. Some are permeable to microorganisms and various chemicals, and/or result in side effects for health care professionals. Gloves that offer the greatest protection and least side effects are highly desirable. Limitations of glove use due to side effects, and glove selection and therapeutic alternatives are described in Part III of this three-part series.

Dermatitis, Occupational↗

The value and limitations of protective gloves in medical health service: part II.

The value of protective gloves in the health care environment is well known. However, these gloves are not perfect. Some are permeable to microorganisms and various chemicals, and/or result in side effects for health care professionals. Gloves that offer the greatest protection and least side effects are highly desirable. Protection against microorganisms and protection against chemicals used in health care are described in Part II of this three-part series.

Antineoplastic Agents↗

The use of protective gloves and the prevalence of hand eczema, skin complaints and allergy to natural rubber latex among dental personnel in the county of Uppsala, Sweden.

During the past decade, there has been an increasing problem with acrylate allergy and natural rubber latex (NRL) allergy among dental personnel. The aim of the present study was to evaluate the prevalence of these problems among dentists, dental nurses and dental hygienists in Uppsala county, Sweden. The study was based on a self-administered questionnaire sent to 690 persons with 527 responders (76%). The most common skin problem was dry skin, fissures and/or itching on the hands. Of the 72 persons (13.6%) reporting to have suffered from hand eczema during the past 12 months, 41 were patch tested with the TRUE Test standard series and the Swedish dental screening series. In the patch tested group, 9.8% reacted to 1 or more of the acrylates. In addition, 389 persons were tested for NRL allergy with the Pharmacia Upjohn CAP-RAST test, and of these, we found 7.2% to be positive. The prevalence of self-reported hand eczema and the number of positive CAP-RAST tests differed between the 3 occupations, with higher figures for the dentists. There was also a correlation between atopic eczema and hand eczema. Of those reporting skin symptoms, 67.7% connected them to the place of work and 28.8% related them to the use of gloves.

Acrylates↗

The effect of an alternate environment as a collection medium on the permeation characteristics of solid organics through protective glove materials.

With a method developed for the determination of permeation characteristics of glove materials by organic solids, a study of the effect of a saline environment on permeation characteristics such as breakthrough and steady state permeation was performed at ambient temperature. The study uses saline as a collection medium and a stainless steel permeation cell designed exclusively for solids. The system allows for materials of five commercially available gloves to be exposed to nine organic solids. Natural rubber latex yielded the shortest and nitrile the longest breakthrough times. Overall, breakthrough times were comparable to a method using a helium collection medium, but in many exposures the saline-based collection medium yielded longer breakthrough times, 2% to 894%. In the testing involving the saline collection medium, results showed that the polarity of the glove material may be a factor that reduces measured permeation rate.

Gloves, Protective↗

High-performance liquid chromatography analysis of rubber allergens in protective gloves used in health care.

A high-performance liquid chromatography (HPLC) method developed for analysis of zinc dithiocarbamates was validated and used to perform a survey of disposable medical gloves used in southern Sweden. The gloves were extracted with acetone at room temperature for 10 min by shaking. The extracts were injected into a polyether ether ketone lined HPLC column, and peaks were analysed by a diode-array detector. The survey shows that of 19 gloves analysed, 10 contained zinc diethyldithiocarbamate (0.070-3.5 mg/g), 3 contained zinc pentamethylenedithiocarbamate (1.0-4.3 mg/g), 4 contained zinc dibutyldithiocarbamate (0.9-1.1 mg/g), and 2 contained 2-mercaptobenzothiazole (0.005-0.008 mg/g). None of them contained thiurams.

Allergens↗

Determination of alkylamine permeation through protective gloves using aliphatic amine pads.

A quantitative study of alkylamine permeation through a glove material using Permea-Tec aliphatic amine pads, used for the detection of chemical breakthrough of protective clothing, was performed for triethylamine following a microwave-extraction process and gas chromatographic analysis. Triethylamine exhibited > 99% adsorption on the pads at a spiking level of 729 ng (1.0 ml). Triethylamine showed recoveries from 63 to 90% (RSD < or = 5%) over the range 0.2-1.0 ml (146-729 ng) applied to pads. The ASTM F739 standard and direct permeability testing procedures were used to determine breakthrough times for five protective glove materials using triethylamine as a challenge chemical. Breakthrough times for six protective gloves were determined ranging from 40 s to > 4 h. The quantitative concentration of triethylamine on the pads following permeation through the gloves was also determined, ranging from 101 to 103 ng cm-2 (382-386 ng per pad).

Amines↗

A quantitative study of aromatic amine permeation through protective gloves using amine adsorptive pads.

A quantitative study of aromatic amine permeation through a glove material using Permea-Tec aromatic amine pads, used for the detection of chemical breakthrough of protective clothing, was performed for aniline following the microwave extraction process and gas chromatographic analysis. Aniline exhibited >99% adsorption on the pads at a spiking level of 1.94 mg (1.9 microL). Aniline showed recoveries from 65 to 89% (RSD < or =5.6%) over the range 1.1-1.9 microL (1.12-1.94 mg) of aniline applied to pads. The modified ASTM F739 and direct permeability testing procedures were used to determine breakthrough times for five protective glove materials using aniline as a challenge chemical. Breakthrough times for six protective gloves were determined, ranging from 182 sec to 82 min. The quantitative concentration of aniline on the pads following permeation through the gloves also was determined, ranging from 0.53 to 0.55 mg/cm2 (1.79-1.88 mg/pad).

Adsorption↗

Permeation and destructive effects of disinfectants on protective gloves.

In working situations where there is a possibility of acquiring blood-borne infections, the use of disinfectants is important. It is also important to use protective gloves, both to protect the skin against disinfectants and to protect against infections. Changes in the structure of the glove material may, however, interfere with the protective capability of the gloves. The influence of 4 disinfectants on the material structure and protective effect of 6 different brands of protective gloves was studied. The proposed International Organization for Standardization (ISO) standard method for determining the liquid chemical resistance of air-impermeable materials was used for permeation testing. Pieces of latex and vinyl glove were also exposed to isopropanol and ethanol for 10, 30 and 60 min and then viewed in a scanning electron microscope. Isopropanol permeated through latex and vinyl gloves in less than 10 min. The polyethylene (PE) gloves were of quite variable quality, and the breakthrough time ranged from 4 to greater than 240 min. The latex and vinyl gloves were also permeated by ethanol, but at a much lower rate. The disinfectants Blifacid, based on p-chloro-m-cresol, and Cidex, based on glutaraldehyde, did not permeate any of the gloves tested within 60 min. Isopropanol had a destructive effect on the material, which became opaque, stiff and brittle. This change in structure was verified with the scanning electron microscope. The tested gloves of latex, vinyl and PE, gave acceptable protection from contact with Blifacid and Cidex for at least 60 min. The same gloves do not give any total protection from contact with isopropanol and ethanol.

Disinfectants↗

In vitro evaluation of the efficacy of skin barrier creams and protective gloves on percutaneous absorption of industrial solvents.

OBJECTIVES: The aim of the experiments was to evaluate the efficacy of skin barrier creams (SBCs) and protective gloves and its potential for reduction of percutaneous absorption of industrial solvents. METHODS: We assessed percutaneous absorption of ethylene glycol (EG), isopropyl alcohol (IA) and 1,2,4-trimethylbenzene (TMB), using static diffusion cells. These solvents were applied neat (EG, TMB) as well as in 10% and 50% aqueous solution (EG, IA) or in 10% and 50% ethanol-diluted solution (TMB). Furthermore, we tested the percutaneous absorption of IA mixed in one cleaning agent (CA), used in newspaper printing shops to clean the rollers of printing machines. Additionally, the penetration behaviour of 10% and 50% solutions of EG, IA and TMB was tested. The experiments were carried out on untreated and on SBC-treated excised human skin from one donor, and on protective gloves. Saline was used as receptor fluid for EG and IA, and neat ethanol for TMB. RESULTS: The penetration of 50% EG, IA and TMB solutions through SBC-treated skin was higher than in untreated skin (factor 3.9 for EG, 0.32 for IA and 0.06 for TMB). The penetration of IA in the IA-CA mixture was five-times higher through untreated skin as for the single compound in 10% aqueous solution. In skin, treated with SBC, we found a 17-fold penetration enhancement of IA in the IA-CA mixture. No appreciable penetration of EG and IA was observed through nitrile rubber gloves. CONCLUSIONS: Our in vitro experiments could not demonstrate an efficacy of SBC to protect skin penetration for the tested solvents. The percutaneous absorption of all solvents in 50% solution was increased through skin treated with SBCs. Furthermore, SBCs enhance the penetration rates of solvents from complex mixtures compared with the single solvents. The tested gloves showed sufficient protection for the hydrophilic solvents, but not for TMB.

2-Propanol↗

Adverse reactions to protective gloves used in the dental profession: experience of the UK Adverse Reaction Reporting Project.

The Adverse Reaction Reporting Project (ARRP) was set up to measure the extent and severity of adverse reactions to dental materials in the UK. Further analysis into the use of protective gloves has been carried out to establish the degree to which gloves are having a deleterious effect on the dental profession. In addition the survey aimed to establish the techniques used to manage adverse reactions and their effectiveness. In a 23-month period, 369 reports were received concerning adverse reactions to protective gloves used in dental practices. Reporters were contacted for further information, and a 92% response rate was achieved. The 330 reports analysed showed dentists to be the largest group to report adverse reactions, whilst dental technicians reported the fewest. The referral rate for staff and patients was similar with a third of adverse reactions being referred (n=110) to a specialist for diagnosis. A confirmed diagnosis was received in 65% of referred cases (n=72), but the symptoms reported suggested a larger degree of Type I reactions occurring than diagnosed. The use of non-powdered gloves appeared to be favoured over powdered gloves in 42% of glove changes, and nitrile gloves were used as an alternative to latex in 39% of changes. In conclusion, the results from this survey showed that wearing gloves in dental practices in the UK caused a range of adverse reactions. In 79% (n=330) of cases reported and analysed, these reactions were readily resolved or improved by self-medication, prescribed medication and/or changing to a different type of protective glove.

Dental Staff↗

A test method for the evaluation of protective glove materials used in agricultural pesticide operations.

The ASTM Standard Test Method for Resistance of Protective Clothing Materials to Permeation by Liquids and Gases (F 739-85) and the recommended permeation cell have been modified to permit the testing of protective clothing materials for permeation by the low volatility, low water solubility active ingredients present in many pesticide formulations. The modification makes use of solid collection medium, a thin (0.02-in. thick) sheet of silicone rubber, to collect permeants. Those compounds permeating the protective material can then be desorbed into an appropriate solvent and analyzed using conventional methods and instruments. A series of permeation tests have been conducted using samples of 10 common, commercially available protective glove materials and the modified cell. Permeation of the active ingredient as well as carrier solvent components of several concentrated pesticide formulations containing low volatility, low water solubility active ingredients and aromatic hydrocarbon carrier solvents has been monitored. The relative breakthrough and the total mass of material permeating the glove materials appears to be strongly related to the concentration of the aromatic carrier solvent present in the formulations studied to date. The collection method was found to be less useful for monitoring the permeation of active ingredients, which have reasonably high water solubilities. The results obtained by using this method with samples of protective glove materials challenged by several concentrated pesticide formulations are described. For these formulations containing xylene boiling range aromatic solvents, gloves made of nitrile rubber, butyl rubber, and Silver Shield were most resistant to permeation; natural rubber and polyethylene glove materials were least resistant.

1-Propanol↗