Effects of comprehensive oral care on nasogastric tube removal in long-term care residents with dysphagia: A multi-center randomized controlled trial.

Oral care is essential for residents in long-term care (LTC) facilities to reduce complications such as aspiration pneumonia. While routine oral hygiene is standard practice, comprehensive oral care (COC)-which includes facial and intraoral muscle massage, salivary gland stimulation, and oral moisturization-may further enhance swallowing function. However, evidence linking COC directly to nasogastric (NG) tube removal remains limited. This study evaluated the effectiveness of COC in facilitating NG tube removal and improving swallowing function among LTC residents with dysphagia. A multicenter, open-label randomized controlled trial was conducted across eight LTC facilities. The intervention group (n = 40) received daily one-on-one COC sessions lasting 30-40 min, while the control group (n = 37) received routine oral hygiene. Participants were followed for six months, with outcomes including NG tube removal, swallowing function, body weight, and pneumonia incidence. At six months, the COC group demonstrated a significantly higher NG tube removal rate, with eight participants achieving full oral intake (p = 0.005). Functional Oral Intake Scale scores were also significantly higher in the intervention group (p = 0.005). Time to NG tube removal ranged from 17 to 182 days. Under intention-to-treat principles, the NG tube removal rate remained significantly higher in the COC group (16.7%vs. 0%, p = 0.005). Competing risks analysis using the Aalen-Johansen estimator confirmed a 6-month cumulative incidence of NG tube removal of 14.6% in the COC group versus 0% in the control group (Gray's test: p = 0.005), with no significant between-group difference in mortality (p = 0.500). No significant differences were observed in body weight change or pneumonia incidence between groups. Among participants who successfully discontinued NG tube use, dementia was the most common underlying condition. These findings suggest that daily one-on-one COC is a feasible intervention in LTC settings and may improve swallowing function while facilitating NG tube removal in residents with dysphagia.

Humans

Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.

BACKGROUND: Wearable sensors are a promising method for collecting clinical trial outcome data for people with Angelman syndrome (AS). However, there has yet to be a systematic probe into the ways in which wearable sensors have been successfully used in AS. The current study aims to provide a quantitative summary of wearable sensors used in AS, including contexts of use and psychometric properties, and to present key narrative highlights. METHOD: Literature searches were performed in three electronic databases: APA PsycInfo, PubMed and Web of Science Core Collection. Data items were categorized into four categories: sample characteristics, study methodological details, wearable sensor characteristics and psychometric properties assessed. Sample characteristics included sample size, age, biological sex, race/ethnicity and cognitive/developmental functioning. Study methodological details were subdivided into study design and setting. Wearable sensor characteristics included sensor type, placement site, means of attachment, assessed construct and sensor-related data loss. Psychometric properties assessed included reliability and validity of sensor-derived data. RESULTS: We identified 16 articles through our systematic review. Wearable sensors were used to study sleep (n = 10, 62.5%), language (n = 2, 12.5%), gait (n = 2, 12.5%), caregiver proximity (n = 1, 6.3%), EEG power (n = 1, 6.3%), and arousal (n = 1, 6.3%) in AS through actigraphs, vocalization recorders, inertial sensors, radio-frequency identification watches, wireless EEG caps, and functional near-infrared spectroscopy caps, respectively. Findings from these studies broadly indicate that wearable sensors are feasible, reliable and valid for assessing a range of behaviours relevant to AS. CONCLUSIONS: Wearable sensors are a promising solution to enhance assessments in AS. However, with the small extant literature characterized by small sample sizes and restricted focus on a few relevant features in AS, there remains ample opportunities to explore the use of wearable sensors in people with AS. Additional studies will better inform clinical decision-making and ultimately improve the lives of people with AS and their families.

Humans

Do wound protectors reduce contamination in total shoulder arthroplasty? A randomized controlled trial.

HYPOTHESIS: Cutibacterium acnes is the most frequent cause of shoulder prosthetic joint infection with skin edges as a source of wound contamination. The primary purpose of this study was to determine if the use of a wound protector device decreases the deep wound bacterial colonization in primary shoulder arthroplasty. The secondary purpose was to assess the effect of device usage on deltopectoral muscle and cephalic vein injury. METHODS: This was a prospective, randomized controlled trial. A total of 100 patients undergoing primary total shoulder arthroplasty were enrolled and randomized into 2 groups: a wound protector group and a control group. Five patients withdrew from the study, leaving 48 patients in the wound protector group and 47 controls. Three deep wound culture swabs were taken after final arthroplasty implantation. The surgeon also graded deltoid, pectoralis major, and cephalic vein injury on a 0-3 scale based on modification to the Tscherne classification of soft tissue injury. The primary outcome of this study was positive culture results for C acnes. Secondary outcomes included total bacterial culture positivity as well as soft tissue injury grades. A subanalysis removing likely contaminant positive cultures (growth >7 days and 1 colony only) was also performed. Comparisons between groups were made using Fisher exact test for categorical outcomes and t tests and Mann-Whitney U tests for continuous variables. RESULTS: The use of a wound protector did not result in any significant differences compared with controls in the rate of positive cultures for C acnes (15% vs. 21%, P = .593) or all bacteria (15% vs. 26%, P = .304). Removing likely contaminant positive cultures did not demonstrate any significant difference in culture positivity (9% vs. 17%, P = .355, for C acnes; 9% vs. 19%, P = .231, for all bacterial species). The wound protector group had better soft tissue injury scores for the deltoid muscle (P < .001) and pectoralis muscle (P < .001). No difference in cephalic vein injury was noted between the 2 groups (P > .05). No difference in surgical time was noted. CONCLUSION: The use of a surgical wound protector device in total shoulder arthroplasty did not significantly decrease bacterial colonization of the deep wound. However, soft tissue damage to the deltoid and pectoralis muscle was less severe in the wound protector group. These findings suggest that this device reduces iatrogenic soft tissue injury.

Humans

Effect of urinary catheter securement band on meatal pressure injury in male intensive care patients: A randomized controlled trial.

OBJECTIVES: To investigate the effectiveness of a urinary catheter securement band in preventing meatal pressure injury (meatal-PI) in male ICU patients, and to identify associated risk factors and the timing of injury development. METHODS: A total of 248 adult male ICU patients were randomly allocated to an intervention group (n&#xa0;=&#xa0;124) or a control group (n&#xa0;=&#xa0;124) between December 2024 and April 2025. The intervention group received a catheter securement band in addition to standard care, while the control group received standard care alone. Meatal-PI was evaluated daily using a structured monitoring form and a validated staging system. RESULTS: The incidence of meatal-PI was significantly lower in the intervention group (6.5%) compared with the control group (16.1%) (p&#xa0;=&#xa0;0.016). Multivariate analysis identified catheter securement, use of silicone catheters, higher Braden Scale scores, and shorter ICU length of stay as independent protective factors, while advanced age was associated with increased risk. Additional factors significantly associated with meatal-PI included comorbidities, higher device burden, latex catheter use, dry skin, lower Glasgow Coma Scale and Braden scores, sedation, and perineal oedema (p&#xa0;<&#xa0;0.001). CONCLUSIONS: The use of a catheter securement band significantly reduces the incidence of meatal-PI in male ICU patients. Incorporating catheter securement devices into routine nursing care, prioritising silicone catheter use, and performing regular meatal assessments may enhance patient safety by reducing the risk of device-related pressure injuries. Further research comparing different catheter securement methods across diverse patient populations is warranted. IMPLICATIONS FOR CLINICAL PRACTICE: The use of catheter securement bands may reduce the incidence of meatal-PI in male ICU patients. Incorporating standardized catheter stabilization strategies into routine intensive care nursing practice may enhance patient safety and support pressure injury prevention efforts.

Humans

The effect of dietetic counseling combined with digital tools intervention on hemodynamic markers in Greek adults: The GATEKEEPER Study.

BACKGROUND AND AIM: Hypertension is a leading cardiovascular risk factor with substantial global impact on morbidity, mortality, and healthcare costs. While lifestyle interventions remain central to management, mHealth technologies offer promising adjunctive support, though their clinical effectiveness remains uncertain. This study evaluated whether combining dietetic counseling with digital tools improves hemodynamic markers in adults aged &#x2265;55 years with increased cardiometabolic risk. METHODS AND RESULTS: This 3-month RCT (NCT05031299) included 954 adults with at least one metabolic syndrome risk factor, allocated 1:1:1 to Standard Care (dietetic counseling), Platform (counseling plus web-based platform), or Platform&#xa0;+&#xa0;Devices (counseling plus platform plus wearables). Outcomes included anthropometrics, lifestyle characteristics, blood pressure, pulse pressure, and estimated pulse wave velocity, analyzed using linear mixed-effects models adjusted for age and sex. All groups improved over 3 months. Waist circumference decreased by -6.29, -4.92, and -4.69&#xa0;cm across Standard Care, Platform, and Platform&#xa0;+&#xa0;Devices groups respectively, and systolic blood pressure declined by -4.84 to -7.15&#xa0;mmHg across groups. The Platform&#xa0;+&#xa0;Devices group showed greater increases in physical activity (94.62 MET-min/week; 95% CI 66.49 to 122.76) and greater reductions in pulse pressure (-3.90&#xa0;mmHg; -6.58 to -1.22) versus Standard Care. Weight loss was associated with lower odds of hypertension (OR 0.4; 95% CI 0.2-0.7), greater likelihood of hypertension reversal (OR 3.6; 1.2-10.3), and higher probability of achieving normal pulse pressure (OR 1.8; 1.1-3.1). CONCLUSIONS: Dietary lifestyle intervention improved cardiometabolic outcomes, with limited added benefit from digital tools. Weight loss was the primary driver of hemodynamic improvement.

Aged

Malaria rapid diagnostic tests: performance, pitfalls, and progress.

PURPOSE OF REVIEW: Malaria rapid diagnostic tests (RDTs) have revolutionized malaria diagnosis in endemic settings. RDTs are simple to use and accurate for clinical cases, although sensitivity is reduced at parasite densities below 200&#x200a;parasites/&#x3bc;l. However, increasing prevalence of hrp2/3 gene deletions in certain areas threaten utility of histidine-rich protein 2 (HRP2)-based RDTs, and lingering HRP2 antigenemia can generate false-positive results after parasite clearance. This review summarizes current performance of malaria RDTs, threats to their validity, and recent innovations to improve their performance and continued role in malaria diagnosis. RECENT FINDINGS: Most World Health Organization (WHO) prequalified RDTs perform well for clinical diagnosis, with only occasional exceptions, including a recently reported issue affecting several countries. RDT sensitivity is generally related to malaria transmission intensity, with higher proportions of false-negative results in lower-transmission areas. Newly prequalified lactate dehydrogenase (pLDH)-based RDTs perform well for both Plasmodium falciparum in areas with >5% hrp2/3 gene deletions&#xa0;and for Plasmodium vivax diagnosis. Several point-of-care alternatives to RDTs, including micro-fluidic devices, hemozoin-detecting devices, and automated hematology analyzers, have shown promising results in small studies, but require larger-scale trials before widespread use. SUMMARY: RDTs remain a critical tool in clinical diagnosis of malaria, and newer pLDH-based tests perform well in areas where hrp2/3 gene deletions threaten validity of HRP2-based RDTs.

Humans

Oxygen-controlled gamma-irradiation and annealing enable terminal processing of collagen-based biomaterials.

Gamma irradiation is a widely adopted method for terminal sterilization of medical devices; however, its application to collagen-based extracellular matrix (ECM) materials remains limited due to radiation-induced degradation of structural integrity and mechanical performance. Here, we present an engineered terminal-processing strategy that combines oxygen controlled gamma irradiation (25-30&#xa0;kGy) with post-irradiation dry-heat annealing to preserve ECM functionality while achieving effective sterilization. By modulating oxygen availability during irradiation, this approach alters radical reaction pathways, suppresses oxygen-mediated oxidative degradation, and generates a metastable radical-containing intermediate, which is subsequently converted into a structurally stabilized collagen network through thermal annealing. As a result, the treated matrices preserved ECM integrity and recovered clinically relevant mechanical properties. Furthermore, the process achieved cumulative viral reductions exceeding 6 log10 across a representative panel including enveloped and non-enveloped DNA and RNA viruses, demonstrating compatibility with sterility assurance and viral safety requirements for biologically derived medical devices. Notably, preliminary observations indicate that mechanical integrity can be partially preserved even at elevated irradiation doses up to 50&#xa0;kGy, suggesting potential applicability to sterilization validation frameworks requiring higher assurance levels. Overall, this work establishes a mechanistically grounded terminal-processing paradigm that enables control of radical fate, decouples sterilization efficacy from material degradation, and integrates sterilization, viral safety, and functional preservation into a unified and scalable framework for collagen-based biomaterials. This concept repositions gamma-irradiation from a purely degradative process to a controllable tool for tuning collagen structure and performance.

Gamma Rays

Home-Based Cardiac Rehabilitation Using a Smart Ring and Telephone Counselling: A Randomized Controlled Trial.

BACKGROUND: Home-based cardiac rehabilitation (HB-CR) is a promising alternative to center-based cardiac rehabilitation as it can address several barriers impeding CR implementation because of its enhanced accessibility. However, to date, HB-CR has not garnered adequate attention due to a lack of communication between patients and medical staff. In this study, we aimed to investigate the effectiveness of HB-CR by monitoring the pulse rate (PR) using a smart ring equipped with photoplethysmography. METHODS: Patients with cardiovascular disease were educated on structured HB-CR methods following a symptom-limited cardiopulmonary exercise test (CPET), and were instructed to wear the device during the exercise session. The recorded PR was uploaded to a website via a smartphone and monitored by medical staff. Patients were randomly assigned to one of two groups: intervention or control group. The intervention group received weekly telephone counselling and was encouraged to maintain optimal levels of physical activity. In contrast, the control group only recorded their exercise data without additional interventions. After 3 months of training, the CPET was performed. RESULTS: Among the 64 randomized patients (32 in each group), an intention-to-treat analysis showed that peak oxygen consumption increased over time in both the groups, with a significantly greater improvement in the intervention group. The group-by-time interaction for peak oxygen consumption was statistically significant (estimated mean difference, 2.0 mL/kg/min; 95% confidence interval, 0.7-3.3; P = 0.004). CONCLUSION: HB-CR using a smart device was effective in improving oxygen consumption. However, appropriate monitoring and timely counselling by medical professionals are important for improved outcomes. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0005893.

Humans

The radiographic effect of cage subsidence on neuroforamina after anterior cervical discectomy and fusion.

STUDY DESIGN: Retrospective Cohort Study. OBJECTIVE: The objective of this study is to investigate the effect of cage subsidence on neuroforaminal area after anterior cervical discectomy and fusion (ACDF) utilizing computed tomography (CT). SUMMARY OF BACKGROUND DATA: Restoration of disc height via implantation of an interbody device provides an indirect decompression of the cervical neuroforamina. Interbody cage subsidence is a potential postoperative occurrence, but the effect of this on neuroforaminal area has yet to be characterized. METHODS: A retrospective review was conducted of patients who underwent one- to four-levels of ACDF utilizing an interbody device with anterior plating. Cage subsidence, neuroforaminal area, height and width were measured on CT scans preoperatively and at least 6&#xa0;months postoperatively. Levels with a cumulative sum of cranial and caudal subsidence greater than 4&#xa0;mm were classified as severely subsided, while levels with cumulative subsidence less than 4&#xa0;mm were classified as non-severely subsided. RESULTS: A total of 83 patients (151 levels) were included in this retrospective analysis. Average endplate subsidence was 3.2&#xa0;&#xb1;&#xa0;1.9&#xa0;mm. Non-severely subsided levels demonstrated a greater perioperative increase in neuroforaminal area (7.9 vs 2.1&#xa0;mm2, p&#xa0;<&#xa0;0.001), neuroforaminal height (1.1 vs 0.4&#xa0;mm, p&#xa0;<&#xa0;0.001) and neuroforaminal width (0.7 vs 0.1&#xa0;mm, p&#xa0;<&#xa0;0.001) compared to severely subsided levels. Interbody subsidence significantly predicted a decreased change in neuroforaminal height, width and area (p&#xa0;<&#xa0;0.001). Severe subsidence was associated with an increased rate of pseudarthrosis, but similar reoperation rates and recurrent neurologic deficits between the two groups. CONCLUSIONS: Severe subsidence of interbody cages after an ACDF was associated with a decreased perioperative change in neuroforaminal dimensions. This decrease in the size of the neuroforamen may reduce the effect of indirect decompression of the nerve root.

Humans

Comparative effectiveness of percutaneous coronary intervention strategies for coronary small-vessel disease: a network meta-analysis of randomized trials.

BACKGROUND: Coronary small-vessel disease (SVD) remains challenging for percutaneous coronary intervention (PCI) because small lumens magnify restenosis and ischemic risk. Multiple devices are available, yet their comparative performance is uncertain. This study evaluated and ranked PCI strategies for SVD. METHODS: A systematic review and network meta-analysis was conducted in accordance with PRISMA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar were searched from inception to 15 August 2025. Eligible studies were English-language randomized controlled trials enrolling adults with angiographic SVD defined as reference vessel diameter &#x2264;3.0&#x2009;mm, comparing PCI strategies, and reporting target lesion revascularization (TLR), binary restenosis (BR), or myocardial infarction (MI). A frequentist random-effects network meta-analysis generated odds ratios (ORs) with 95% confidence intervals (CIs) and treatment rankings using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirty-nine trials including 14,503 patients met the criteria. For TLR (37 studies; 11,980 patients), the highest SUCRA values were observed with sirolimus-eluting stents (SES 90.1%), zotarolimus-eluting stents (ZES 83.9%), and everolimus-eluting stents (EES 82.2%). For BR (32; 6,468), SES, ZES, and paclitaxel-coated balloons (DCB-PTX) ranked highest (95.0%, 80.0%, and 78.3%). For MI (37; 11,602), SES, DCB-PTX, and ZES ranked highest (79.0%, 78.7%, and 68.5%). Representative effects showed SES reduced TLR versus bare-metal stents (BMS) (OR, 0.25; 95% CI, 0.15-0.43) and MI versus BMS (OR, 0.41; 95% CI, 0.21-0.79). Conventional approaches such as BMS, plain old balloon angioplasty (POBA), and gold-plated balloon angioplasty (GPBA) ranked lowest across outcomes. CONCLUSION: SES provides the most consistent clinical benefit for coronary SVD. ZES, EES, and DCB-PTX are effective alternatives in selected settings, whereas BMS, POBA, and GPBA are less effective. These findings offer comparative evidence to guide device selection in SVD.

Humans

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

The environmental impact of diagnosis and therapy in obstructive sleep Apnea: A systematic review.

Healthcare contributes significantly to global greenhouse gas (GHG) emissions, yet the environmental impact of sleep medicine, particularly the diagnosis and therapy of obstructive sleep apnea (OSA), remains poorly characterized. We systematically searched PubMed, Scopus, and Embase (2015-2025) for studies on OSA care reporting environmental metrics (carbon footprint, energy use, resource consumption) or healthcare resource utilization. Supplementary searches identified additional non-peer-reviewed sustainability-focused studies that have been presented at conferences. Of 19 primary peer-reviewed studies on OSA care and utilization, only one reported environmental metrics (telemedicine CO2 savings related to reduction in travel-related emissions). Supplementary sources revealed that OSA care has a measurable carbon footprint driven by disposable equipment, device electricity, and travel and that OSA diagnostics create significant solid waste with opportunities for waste reduction through the use of reusable equipment. This review shows that while the environmental impact of sleep medicine has been rarely studied to this date, available evidence suggests significant opportunities for sustainability through virtual care, home testing, and equipment optimization. Future research should incorporate environmental impact into the assessment of clinical pathways.

Humans

Morphology-Encoded Colorimetric Hydrogen Sensing Using Embedded Reactive Pd Absorbers in Fabry-Perot Cavities.

Chemical reactions offer a powerful strategy for generating visible optical responses through localized changes in absorption, dielectric environment, and interfacial wetting. A palladium (Pd)-embedded Fabry-Perot cavity is introduced as a reaction-active optical platform in which structural color is governed by intracavity absorption coupled with reaction-induced dielectric perturbation. Positioning Pd within the dielectric spacer creates a spatially controllable reactive absorber whose vertical location relative to the standing-wave field dictates wavelength-selective absorption within the cavity. The morphology of the embedded Pd layer provides an additional design parameter by modulating both optical loss and interfacial wetting. Under hydrogen exposure in the presence of oxygen, catalytic water formation at the Pd/polymer interface generates localized dielectric heterogeneity and interfacial water droplets, thereby perturbing the optical path length and amplifying the visible response. As a result, the cavity exhibits pronounced, morphology-dependent color transitions that are inaccessible through dielectric-layer engineering or Pd/PdH refractive-index changes alone, enabling direct visual hydrogen sensing under ambient light, as well as flexible optical devices capable of large-area patterning. These findings establish a design framework for reaction-active optical cavities that translate localized chemistry into a colorimetric hydrogen sensing mechanism.

Fabry&#x2013;Perot resonator

Diagnostic Value and Limitations of Dermoscopy in Humans and Animals: A Critical Comparative Analysis.

BACKGROUND: Dermoscopy is a noninvasive imaging technique that is well-established in human dermatology, where it enhances the diagnosis of neoplastic, inflammatory, infectious, and alopecic skin disorders. In veterinary dermatology, its use is expanding yet remains heterogeneous and largely descriptive, despite growing evidence of conserved dermoscopic patterns across species. HYPOTHESIS/OBJECTIVES: To review the applications of dermoscopy in veterinary dermatology, and to provide a comparative analysis of dermoscopic features observed in dogs, cats, and horses in relation to corresponding findings in human dermatology. MATERIALS AND METHODS: A systematic review of the literature reporting dermoscopic findings in veterinary dermatology was conducted in accordance with PRISMA guidelines. PubMed, Scopus and Google Scholar were searched for studies published up to 30 July 2025. Eligible studies included original articles describing dermoscopic features in dogs, cats, or horses. Extracted data included species, dermatological condition, dermoscopic findings, device type and histopathological correlation, when available. Levels of evidence were assessed using the Oxford Centre for Evidence-Based Medicine criteria. RESULTS: Thirty studies met the inclusion criteria. Most were descriptive case reports or case series. Dermoscopy was applied to a wide range of conditions, including alopecias, parasitic infestations, dermatophytosis, neoplastic and sebaceous lesions, inflammatory dermatoses, and congenital vascular anomalies. Recurrent dermoscopic features showed strong similarities to those described in human dermatology, although species-specific anatomical differences influenced interpretation. CONCLUSIONS: Dermoscopy represents a valuable adjunct diagnostic tool in veterinary dermatology, with clear translational relevance. Standardisation of terminology and further prospective studies are required to support its broader clinical integration.

Animals

Barefoot ambulation following partial foot amputation: A systematic review of biomechanical outcomes.

BACKGROUND: Partial foot amputation (PFA) is increasingly performed due to rising prevalence of diabetes and peripheral vascular disease. While PFA may preserve gait and reduce energy expenditure compared with transtibial amputation, biomechanical deficits are common. This review aimed to evaluate biomechanical outcomes during baref following PFA. METHODS: A systematic review was conducted. MEDLINE, Embase, CINAHL, SCOPUS and Web of Science databases were searched for studies reporting biomechanical outcomes in adults with PFA without prosthesis. Eligible outcomes included spatiotemporal metrics, joint kinematics and kinetics, plantar pressures, and ground reaction forces. FINDINGS: Twelve studies including a total of 101 participants met inclusion criteria. Across studies, PFA was associated with impaired barefoot gait. This included spatiotemporal changes, such as reduced walking speed and shorter step length, and kinetic changes, such as reduced ankle power. Elevated plantar pressures were commonly reported, particularly in the forefoot and midfoot, highlighting loading abnormalities in the residuum. Several studies also described proximal compensatory strategies at the knee and hip, suggesting that biomechanical consequences extend beyond the foot and ankle. However, the evidence base was limited by small sample sizes, inconsistent protocols, and substantial heterogeneity. INTERPRETATION: Barefoot walking is impaired after partial foot amputation and the degree of dysfunction may vary by amputation level. Abnormal loading and compensatory changes may extend beyond the foot and ankle to the knee and hip. Given the limited and methodologically heterogeneous evidence, larger prospective studies with standardised biomechanical outcomes are needed to clarify the effects of amputation level and aetiology. This standardisation is important to inform surgical planning, rehabilitation, and prosthetic device design.

Humans

Implementing a novel digital health platform for self-management of postmenopausal osteoporosis: A qualitative study of user experiences, perspectives and implementation outcomes.

BACKGROUND: Osteoporosis self-management requires scalable support, and digital health platforms may meet this need. This study aimed to characterise the experiences and perspectives of postmenopausal women who participated in a 12-month randomised controlled trial (RCT) of a digital voice assistant (DVA) delivered osteoporosis self-management intervention, and to assess key implementation outcomes. METHODS: This was a qualitative analysis of interviews with postmenopausal women from the intervention arm (DVA group) of the RCT. The DVA program broadcast education videos, medication reminders, home-based exercise, nutrition advice and monthly quizzes through a DVA device. Semi-structured interviews were recorded, transcribed and managed in NVivo through reflexive thematic analysis, guided by the Practical Planning for Implementation and Scale-Up and Proctor's implementation outcome taxonomy frameworks. Evidence weighting summarised participant coverage and code density. RESULTS: Twenty-two of 25 (88%) DVA group participants completed semi-structured interviews. Thematic analysis identified seven themes mapped to Proctor's implementation outcomes. Evidence weighting indicated strong support for the intervention's appropriateness and acceptability, moderate support for its adoption, fidelity, feasibility and sustainability, and limited support for costs. Participants valued clear audiovisual guidance, conversation-based interactions with natural language, and flexible home-based access to self-management. CONCLUSION: Digital health platforms for osteoporosis self-management appear feasible, acceptable and sustainable among postmenopausal women. Findings indicate that these platforms are approaching readiness for evaluation in implementation-focused settings, contingent on streamlined content, reliable delivery modalities, accessible user support, clear privacy regulations and pragmatic pricing models.

Humans

Virtual Reality Mastoidectomy as Precadaver Training for Novices: A Randomized Crossover Study.

OBJECTIVES: To compare cognitive load during virtual reality (VR) simulation and cadaveric dissection (CD) mastoidectomy training in novice learners. To determine whether training order influences cognitive load, characterize cognitive load progression during the procedure, and assess whether VR training improves subsequent cadaveric performance. METHODS: In this randomized crossover study, 24 core surgical trainees with no prior mastoidectomy experience performed a cortical mastoidectomy in both VR and CD settings. Participants were randomized to either VR-first or CD-first training sequences. Cognitive load was measured using a bespoke auditory reaction-time device at baseline and 10, 30, and 50&#x2009;min. Relative reaction time (RRT) served as an objective index of cognitive load. Cadaveric performance was assessed using the Modified Welling Scale by two blinded otologists. RESULTS: Cognitive load was significantly lower during VR than CD, with mean RRT rising 26% from baseline in VR versus 60% in CD (p&#x2009;<&#x2009;0.001). Training order did not affect cognitive load in either modality, and RRT increased progressively throughout mastoidectomy in both VR and CD. Participants who began with VR achieved significantly higher cadaveric performance scores than those who began with CD (mean 9.50 vs. 4.96; p&#x2009;<&#x2009;0.001), and inter-rater reliability for performance scoring was high. CONCLUSION: VR mastoidectomy reduces cognitive load and enhances subsequent cadaveric performance in novice trainees, supporting its role as a cognitively optimized precadaver training modality that complements, rather than replaces, cadaveric dissection. These findings suggest VR enhances early learning efficiency and resource utilization in novice otolaryngology training. LEVEL OF EVIDENCE: N/A.

Humans

The application of artificial intelligence in healthcare practice: A mapping review of systematic reviews.

Artificial intelligence (AI) is rapidly transforming healthcare practice, with growing evidence supporting its use in diagnosis, prognosis, treatment planning, and operational decision-making. The proliferation of systematic reviews in recent years underscores the need for an updated synthesis of the literature to inform research, policy, and practice. We searched PubMed, Web of Science, Scopus, IEEE Xplore, and CINAHL for systematic reviews and meta-analyses published between 2019 and February 2026. Eligible reviews focused on AI applications in healthcare practice, were peer-reviewed, and written in English. A total of 368 reviews met the inclusion criteria. Publication volume increased steadily, peaking in 2025. AI research was concentrated in high-density domains, such as radiology, oncology, and critical care. Across reviews, diagnostic imaging, electronic health record (EHR) data, and biomarkers/laboratory results accounted for 68% of training data sources, though newer data types, such as wearable device and sensor data, emerged from 2022 onward. Diagnosis, prognosis, and treatment comprised over 80% of AI applications, with novel uses emerging in recent years, such as AI-assisted clinical documentation (e.g., ambient documentation tools) and patient education. Ethical concerns were reported in 78.5% of reviews, with privacy, model accuracy, data and algorithmic bias, and explainability as recurrent themes. The proportion of reviews reporting ethical concerns increased from 2021 to 2025. AI applications in healthcare are expanding in scope, diversifying in data sources, and evolving toward novel clinical and operational uses. The human-centered AI or augmented intelligence paradigm, integrating computational precision with clinical expertise, holds significant promise but will require parallel advances in governance, regulatory frameworks, and ethical oversight to ensure safe adoption.

Artificial Intelligence