Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SYRINGES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Auto-disable syringes for immunization: issues in technology transfer.

WHO and its partners recommend the use of auto-disable syringes, "bundled" with the supply of vaccines when donor dollars are used, in all mass immunization campaigns, and also strongly advocate their use in routine immunization programmes. Because of the relatively high price of auto-disable syringes, WHO's Technical Network for Logistics in Health recommends that activities be initiated to encourage the transfer of production technology for these syringes as a means of promoting their use and enhancing access to the technology. The present article examines factors influencing technology transfer, including feasibility, corporate interest, cost, quality assurance, intellectual property considerations, and probable time frames for implementation. Technology transfer activities are likely to be complex and difficult, and may not result in lower prices for syringes. Guidelines are offered on technology transfer initiatives for auto-disable syringes to ensure the quality of the product, the reliability of the supply, and the feasibility of the technology transfer activity itself.

Disposable Equipment↗

The influence of needle and syringe size on chorionic villus sampling of term placentae: a randomised trial.

OBJECTIVE: To determine the effect of needle and syringe size on the amount of tissue obtained at chorionic villus sampling METHODS: Two needle sizes, 18 and 20 gauge, and two syringe sizes 5 mL and 20 mL, were used to assess samples from term post-partum placentae. Each of the four combinations was tested by 25 aspirations. The placentae were divided into 100 grid spaces and each grid space was randomly allocated to a needle/syringe combination. The resulting samples were cleaned to separate the chorionic villi (CV), centrifuged and then weighed. RESULTS: Significantly more tissue was obtained with an 18-g needle compared with a smaller 20-g needle (median weight difference 1.5 mg, 95% CI 0.8-2.3 mg). More tissue was also obtained with the larger 20-mL syringe though the impact of the syringe size was less than that of the needle size (median difference 0.8 mg, 95% CI 0-1.6). CONCLUSION: A larger syringe and needle size yields a larger quantity of chorionic villi from the post-partum term placenta.

Chorionic Villi Sampling↗

Syringe availability as HIV prevention: a review of modalities.

This review examines recent research into modalities for improving access to sterile syringes for injection drug users (IDUs) as a means to reduce human immunodeficiency virus (HIV) transmission. English language studies with empirical data were collected through Uncover reports and MedLine searches from 1998 to 2000. Although syringe-exchange programs are the most established and well-evaluated means of improving access to sterile syringes, research on alternative modalities-such as pharmacy sale, injector-specific packs, mass distribution, and vending machines-and on coverage of special populations suggests the need to pursue multiple avenues of increasing syringe availability simultaneously and, in particular, to explore modalities other than syringe-exchange programs when HIV incidence is under control. The impacts on HIV transmission of cocaine injection and sex with IDUs need to be explored further. Finally, any evidence of declining hepatitis C incidence among young IDUs might serve as a surrogate for a sharp drop in injection-related HIV risk behaviors in that population.

Developed Countries↗

Disposable insulin syringe reuse and aseptic practices in diabetic patients.

Diabetic patients are traditionally taught to discard plastic syringe/needle units after a single use and to employ aseptic technique for administering insulin injections. We surveyed 87 diabetic outpatients for compliance with aseptic recommendations. We then studied prospectively the effects of reusing disposable syringes in 56 diabetic patients who reused syringes a mean of 6.6 times for 8.3 months and an aggregate of 23,664 injections. Almost half (49%) of diabetic patients in a combined university clinic and private practice reused supposedly disposable insulin syringes a mean of 3.9 times. Compliance with standard aseptic precautions was poor, with only 29% of patients following recommended practices. No adverse effect of syringe reuse was identified. The authors conclude that diabetic patients frequently reuse disposable syringes, without apparent harmful effect.

Asepsis↗

Syringe pressure irrigation of subdermic tissue after appendectomy to decrease the incidence of postoperative wound infection.

To evaluate syringe pressure irrigation of the surgical wound to decrease its infection after appendectomy, we designed a randomized control trial at the Emergency Department of Mexico City General Hospital, including 350 patients with acute abdomen suggestive of appendicitis, without any other infection clinically evident. The trial was randomized into 2 groups. Group I patients received prophylactic systemic antibiotics before surgery. Group II patients received the same prophylactic systemic antibiotics plus syringe pressure irrigation of the surgical wound with 300 ml of saline solution using a 20-ml syringe with 19-gauge intravenous (IV) catheter to measure the incidence of postoperative wound infection. In our results, 283 patients had appendicitis. Of these, 188 were uncomplicated (66.4%) and 95 (33.6%) were complicated. Of the complicated cases, 40 were assigned to group I, and of these, 29 (72. 5%) developed wound infection. In group II there were 55 patients and only 9 (16.3%) developed wound infection after syringe pressure irrigation [p = 0.000001; 95% confidence interval (CI) = 0.02-0.22]. We conclude that syringe pressure irrigation of the surgical wound after appendectomy contributes significantly to decrease the incidence of postoperative wound infection in complicated cases. It is a cheap, safe, and accessible method in any surgical room.

Adolescent↗

Safety and immunogenicity of Haemophilus influenzae type b-tetanus toxoid conjugate, presented in a dual-chamber syringe with diphtheria-tetanus-pertussis and inactivated poliomyelitis combination vaccine.

The safety and immunogenicity of combining two established vaccines, polyribosyl ribitol phosphate conjugated to tetanus toxoid (PRP-T) (ActHIB, Pasteur Mérieux Connaught, Lyon, France) and diphtheria-tetanus-whole cell pertussis and inactivated poliovirus vaccine (DTP-IPV) (Tetracoq, Pasteur Mérieux Connaught, Lyon, France) were evaluated using a new dual-chamber syringe delivery system. Results were compared with those obtained when the two combination vaccines were either administered separately (two sites) or reconstituted manually and injected at a single site. A total of 487 2-month-old infants were enrolled in this study by 61 paediatricians in France. Infants were randomised to receive three immunisations of PRP-T and DTP-IPV at 2, 3 and 4 months of age, given either with the dual-chamber syringe (n = 213), as separate injections (n = 215), or as a single manually reconstituted injection (n = 59). Blood samples were taken prior to the first immunisation and 4 weeks after the third immunisation for the measurement of antibody titres. Infants were monitored by the parents for 3 days after each immunisation to detect local and systemic reactions. Local and systemic reactions occurring the 3 days following immmunisation were as expected for the combination vaccines used. Safety of the vaccination using the dual-chamber syringe was as good as, if not slightly better than, that for the two vaccines administered separately. After the first immunisation, pain and unusual crying were significantly more frequent in infants who received two injections, compared to those who were immunised with the dual-chamber syringe. Serological responses were good for all antigens in the three groups and there was no evidence for any immunological interference. Almost all subjects in each group achieved levels of antibodies considered to be protective for all antigens. There were no clinically relevant differences in antibody response between any of the groups. The dual-chamber and separate injection methods of vaccination were equivalent according to a pre-defined criterion (percentage of infants with anti-PRP antibody titres > or =1.0 microg/ml). Results from this study suggest that the two vaccines, PRP-T and DTP-IPV, may be safely and effectively administered in infants using the new dual-chamber syringe. This presentation provides an innovative strategy to combine different vaccines that are not yet available as a single formulation.

Agglutinins↗

Exponential gradient maker using a disposable syringe.

With a simple modification, any disposable syringe can become a reliable and easy to use exponential gradient maker. The modification consists of two notches, made with a razor blade, in the borders of the rubber sealing tip of the plunger. A clamp in the tube connected to the syringe allows control over solution flow. With the clamp prohibiting drainage, the body of the syringe is filled with the desired volume of starting solution I. A magnetic stir bar, small enough to spin inside the syringe is included. The notched plunger is introduced until no air space remains. This forms the fixed volume, closed mixing chamber, while the rest of the volume of the syringe forms the open chamber. The two chambers are connected through the notches in the plunger. The ending solution II is poured after the introduction of the plunger. Opening the clamp allows solution I in the closed chamber to flow out, and the solution II in the open chamber flows through the notches and mixes with solution I. This exponential gradient maker can be reused many times, but the low cost of the components makes it potentially disposable. This feature is especially useful when using toxic chemicals, or when pouring polyacrylamide gradient gels, since the apparatus may be disposed of after contamination or eventual polymerization.

Chemistry Techniques, Analytical↗

Relationship of syringe-tip diameter to voids in elastomer impressions.

An in vitro study was done to determine the relationship between syringe-tip diameters and the number of bubbles in extruded strips of two vinyl silicone impression materials. Results disclosed the following. There were highly significantly fewer bubbles in impression material extrusions from the second half of the syringeful than from the first half (p less than .001). The smaller-tip orifices, 0.6 and 0.67 mm in diameter, caused highly significantly fewer bubbles in the extruded impression materials than did the larger tips (p less than .001). The reasons and clinical implications for these effects are unknown and are being explored. From subjective observations, it was concluded that the pneumatically powered syringe provided an easier means of extruding the impression material through small syringe-tip orifices than did the conventional hand-powered syringe.

Dental Impression Materials↗

A laboratory investigation of a new design of self-aspirating syringe.

A new design of dental cartridge syringe which incorporates a double self-aspirating mechanism has been investigated under controlled conditions in the laboratory. The new design was compared to two self-aspirating syringes which have been available for some time, namely the Astra and Aspiject syringes. The new syringe aspirated as effectively as the Astra design and was better in this respect than the Aspiject. The method used to examine the syringes involved tests which might be of value in creating standards for dental local anesthetic cartridges.

Anesthesia, Dental↗

Performance of disposable needle syringe systems for local anesthesia.

The performance of different disposable needle syringe systems was determined by measuring needle-puncture pain, needle-bending forces, and the fluid dynamics of the systems. Thirty-gauge needles cause less needle-puncture pain than any other needle. The force required to bend the 30-gauge needle irreversibly was lower than that for the other needles. Studies of the fluid dynamics of different needle syringe assemblies demonstrated that the flow rate can be limited by using large-size syringes (30 mL) and needles with the smallest internal diameter. On the basis of the results of this study, 30-gauge needles attached to 10-mL syringes are recommended for infiltration anesthesia, and 25-gauge needles with 10-mL syringes are advocated for regional nerve blocks. In infiltration anesthesia, the local anesthetic agent should be injected slowly into the subdermal tissue over a 10-second period. When performing regional nerve blocks, it is also advisable to inject the local anesthetic agent over a 10-second time interval.

Anesthesia, Local↗

Transthoracic needle biopsy. What size syringe?

Using a vacuum gauge we demonstrated that with less effort, the identical vacuum can be obtained using a 10-cc syringe as opposed to a 50-cc syringe. We recommend using a 20 cc syringe during transthoracic needle aspiration since the syringe is easier to handle and still allows sufficient vacuum to be developed, even if a small amount of air enters the syringe.

Biopsy, Needle↗

Stability of premixed syringes of diamorphine and hyperbaric bupivacaine.

BACKGROUND: It is common clinical practice to add diamorphine to heavy bupivacaine when performing spinal anaesthesia for either obstetric or general surgical procedures. If pre-filled syringes were available potential problems arising due to the wrong mixture being administered could be reduced, whilst also providing greater assurances of sterility and accuracy of dosage. It is therefore necessary to establish whether diamorphine 100 microg/mL is stable in solution with 0.5% hyperbaric bupivacaine, to allow production of pre-filled syringes for use in spinal anaesthesia. METHOD: Diamorphine hydrochloride was dissolved in water for injection, and added to hyperbaric bupivacaine then stored in 5-mL plastic syringes. Eleven syringes were stored at 40 degrees C/75% relative humidity, 25 degrees C/60% relative humidity and 7 degrees C for 90 days. Samples were taken at five time points for measurement of diamorphine and bupivacaine concentrations using high performance liquid chromatography. RESULTS: Diamorphine concentrations fell over the study period. No significant changes were observed the bupivacaine content of the samples. There was 10% degradation of diamorphine after 4 days at 40 degrees C, after 7 days at 25 degrees C, and after 26 days at 7 degrees C. CONCLUSION: Diamorphine is stable in hyperbaric bupivacaine at 7 degrees C for long enough to allow preparation of pre-filled syringes in advance (by hospital pharmacy aseptic units) for use in spinal anaesthesia.

Analgesics, Opioid↗

A comparison of the aspirating abilities of re-usable and partly disposable dental cartridge syringes in vitro.

OBJECTIVES: To compare the ability of re-usable and partly disposable dental cartridge syringes to aspirate in vitro. METHODS: A laboratory investigation comparing two re-usable (Astra and Rotor) and one partly disposable (Ultra Safety-plus) dental cartridge syringes. Forces needed to move the cartridge plunger and forces required to produce aspiration of Bonney's Blue dye were measured using an Instron testing machine. RESULTS: There were significant differences in the forces needed to produce aspiration in the different systems (F = 194, p<0.001). The Astra system needed the least force to produce aspiration. The forces required to aspirate in the Rotor and Ultra Safety-plus systems did not differ. Each system aspirated effectively in vitro at the initial aspiration manoeuvre. The forces available for subsequent aspiration attempts varied with the speed of cartridge plunger movement. The volume of local anaesthetic cartridge used did not affect the force needed to produce aspiration in the Ultra Safety-plus syringe. The method of testing free-flow of solution through the needle affected the force generated at subsequent plunger movements. CONCLUSIONS: The re-usable and partly disposable syringes investigated aspirated effectively at the initial aspiration manoeuvre. The force available to produce aspiration at subsequent attempts varies with the speed of injection. The method of testing free-flow of solution through the needle in a loaded syringe affects the force available at the first aspiration manoeuvre.

Anesthesia, Dental↗

Pandemic influenza preparedness: the critical role of the syringe.

In the face of an almost unprecedented threat of a global pandemic of influenza it is imperative that stockpiling of appropriate drugs and devices begin now. One vital device is an appropriate syringe for delivering vaccine. With the potential for millions to be infected and the vaccine supply severely stretched it is imperative that the syringe used to vaccinate waste as little vaccine as possible and thus allow for a maximum number of persons to be vaccinated. Our study tested seven leading candidate vaccine syringes for dosing accuracy, dose-capacity per vial, medication wastage and a battery of ergonomic features. One device, the Flu+trade mark syringe, proved superior to the others in all important categories, possibly due to its low dead-space volume and its dosing accuracy. The data suggest that switching to this device from any of the others tested would provide between 2 and 19% additional vaccine doses per vial if the current 10-dose vials are used. Extrapolations from this data suggest that many thousands to millions of additional persons could be vaccinated in mass campaigns. Use of a syringe of this type, and the vaccine savings that would accrue, would likely be important in reducing morbidity and mortality in the event of a pandemic of influenza.

Disease Outbreaks↗

HIV incidence among injecting drug users in New York City syringe-exchange programmes.

BACKGROUND: There have been no studies showing that participation in programmes which provide legal access to drug-injection equipment leads to individual-level protection against incident HIV infection. We have compared HIV incidence among injecting drug users participating in syringe-exchange programmes in New York City with that among non-participants. METHODS: We used meta-analytic techniques to combine HIV incidence data from injecting drug users in three studies: the Syringe Exchange Evaluation (n = 280), in which multiple interviews and saliva samples were collected from participants at exchange sites; the Vaccine Preparedness initiative cohort (n = 133 continuing exchanges and 188 non-exchangers, in which participants were interviewed and tested for HIV every 3 months; and very-high-seroprevalence cities in the National AIDS Demonstration Research (NADR) programme (n = 1029), in which street-recruited individuals were interviewed and tested for HIV every 6 months. In practice, participants in the NADR study had not used syringe exchanges. FINDINGS: HIV incidence among continuing exchange-users in the Syringe Exchange Evaluation was 1.58 per 100 person-years at risk (95% CI 0.54, 4.65) and among continuing exchange-users in the Vaccine Preparedness Initiative it was 1.38 per 100 person-years at risk (0.23, 4.57). Incidence among non-users of the exchange in the Vaccine Preparedness Initiative was 5.26 per 100 person-years at risk (2.41, 11.49), and in the NADR cities, 6.23 per 100 person-years at risk (4.4, 8.6). In a pooled-data, multivariate proportional-hazards analysis, not using the exchanges was associated with a hazard ratio of 3.35 (95% CI 1.29, 8.65) for incident HIV infection compared with using the exchanges. INTERPRETATION: We observed an individual-level protective effect against HIV infection associated with participation in a syringe-exchange programme. Sterile injection equipment should be legally provided to reduce the risk of HIV infection in persons who inject illicit drugs.

Adult↗

Assessment of the stability of dalteparin sodium in prepared syringes for up to thirty days: an in vitro study.

BACKGROUND: If a low-molecular-weight heparin (LMWH) injectable formulation maintains its stability for up to 30 days, substantial cost reductions in hospital stay could be achieved with its use on an outpatient basis in patients who might otherwise be treated with IV heparin as inpatients. OBJECTIVE: This study was designed to assess the stability for up to 30 days of injectable solutions of the LMWH dalteparin sodium when repackaged in plastic syringes. METHODS: In the first part of the study, 1-mL and 3-mL plastic syringes were filled with the contents of a 10,000-IU/mL dalteparin ampule or a 25,000-IU/mL dalteparin multidose vial. In a separate part of the study, 1-mL and 3-mL syringes were filled with doses of 7500 IU and 10,000 IU, respectively, from a 10,000-IU/mL multidose vial. After the syringes were brought to room temperature or 4 degrees C, the stability of dalteparin was assessed over 30 days by measuring anti-factor Xa levels. RESULTS: No significant loss of dalteparin activity was found for up to 30 days in the syringes after storage at room temperature or 4 degrees C. The solutions retained anti-factor Xa activity at room temperature and under refrigeration. CONCLUSION: Dalteparin is stable for up to 30 days when stored at room temperature or 4 degrees C. The findings suggest that preparation of a postdischarge supply of dalteparin is feasible, contributing to more convenient and effective management of outpatients at risk for thrombotic complications.

Anticoagulants↗

Subcutaneous administration of midazolam: a comparison of the Bioject jet injector with the conventional syringe and needle.

PURPOSE: The purpose of this study was to compare jet injection to a syringe and needle in terms of the difference in discomfort and pharmacokinetics after the subcutaneous administration of midazolam. PATIENTS AND METHODS: Using a prospective, randomized, double-blinded study design, 14 subjects were administered midazolam on two separate occasions (at least 2 weeks apart). The subjects were randomly distributed into two groups: syringe and needle (saline)/jet injector (midazolam) or syringe and needle (midazolam)/jet injector (saline). The subjects were randomly assigned to receive either EMLA (eutectic mixture of local anesthetics) or a placebo at the injection site for the first administration and the other topical agent on the second visit. Each subject received one subcutaneous injection in the deltoid region per arm per day. Each injection contained the same volume of solution. Subjects completed visual analog scale (VAS) questionnaires assessing the discomfort of the injection. Blood samples were taken at specified intervals over 2 hours for determination of midazolam levels. RESULTS: The discomfort associated with the injection was less with the Biojector 2000 (Bioject Inc, Portland, OR) although this was not statistically significant. However, persistent discomfort was significantly greater at the needle site. The mean peak plasma level of midazolam was achieved more rapidly with the Biojector 2000 than with the syringe and needle (P < .05). However, the peak plasma level after jet injection or injection with a syringe and needle was not statistically different. CONCLUSION: The results of the study show that the Biojector 2000 is a needle-free injection system that can be used for the administration of a premedicant before induction of anesthesia. It has several advantages, including the potential reduction of anxiety associated with the "fear of needles" and occupational injuries.

Adolescent↗

Cleansing the traumatic wound by high pressure syringe irrigation.

The purpose of this study was to examine the influence of the fluid dynamics of syringe irrigation on the efficacy of wound cleansing and the infection rate of experimental wounds. The pressure experienced by a surface following wound irrigation was directly proportional to the pressure within the syringe and the size of the needle. High pressure syringe irrigation effectively removed bacteria from the surface of the wound. This reduction in the wound bacterial count resulted in a decrease in the infection rate of tissues. Low pressure irrigation with an asepto syringe did not significantly cleanse the wound of its bacterial contaminants and had no demonstrable clinical merit. On the basis of these studies, high pressure syringe irrigation is being employed routinely in our emergency department for the care of traumatic wounds.

Animals↗