With a simple modification, any disposable syringe can become a reliable and easy to use exponential gradient maker. The modification consists of two notches, made with a razor blade, in the borders of the rubber sealing tip of the plunger. A clamp in the tube connected to the syringe allows control over solution flow. With the clamp prohibiting drainage, the body of the syringe is filled with the desired volume of starting solution I. A magnetic stir bar, small enough to spin inside the syringe is included. The notched plunger is introduced until no air space remains. This forms the fixed volume, closed mixing chamber, while the rest of the volume of the syringe forms the open chamber. The two chambers are connected through the notches in the plunger. The ending solution II is poured after the introduction of the plunger. Opening the clamp allows solution I in the closed chamber to flow out, and the solution II in the open chamber flows through the notches and mixes with solution I. This exponential gradient maker can be reused many times, but the low cost of the components makes it potentially disposable. This feature is especially useful when using toxic chemicals, or when pouring polyacrylamide gradient gels, since the apparatus may be disposed of after contamination or eventual polymerization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Domingo. 1990-08-15. Exponential gradient maker using a disposable syringe.. https://doi.org/10.1016/0003-2697(90)90049-f

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Light activated patterning of dye-labeled molecules on surfaces.

This Communication describes a novel method for patterning proteins, ligands, or other organic/inorganic species onto solid substrates. The process works by linking the moiety of interest to a fluorophore that can be subsequently photobleached and bound to the interface. The technique can be performed in aqueous solution and allows several species to be addressed onto the surface simultaneously by using different frequencies of light. Because the method can be used with fluorophores excited by visible light, shorter and more damaging wavelengths can be avoided.

Chemistry Techniques, Analytical↗

Virgin olive oil quality classification combining neural network and MOS sensors.

A model based on neural networks has been designed to detect lampante virgin olive oils, a category of olive oil that cannot be consumed without a previous refining process according to the current regulation of the European Communities. The response of 7 metal oxide sensors analyzing 114 olive oil samples has been used in the design, training, and internal validation of the neural network with only 4.5% error in validation. The designed mathematical model, the equations of which are fully described, has been validated also with an external set of 13 samples of diverse varieties and geographical origins with 100% correct classification.

Chemistry Techniques, Analytical↗