Comments on past and present situation of intensive monitoring of the fetus during labor.

Modern intensive monitoring of the fetus during labor affords the opportunity for the greatest possible safety to the infant, whilst at the same time dispensing with unnecessary operations to terminate labor which can be dangerous for the mother and her child. Developments over the past 28 years, since cardiotocography has been in clinical use, have unfortunately also been accompanied by confusion and mistakes. We think that there are two main reasons for this: I. Many who use cardiotocography have not assessed its efficiency correctly. Heart rate pattern with all their variations have too often been regarded as the only diagnostic criteria for the determination of fetal hypoxia. However this procedure only allows a rough selection of actually endangered fetuses. In more than 50% of the cases with a suspicious or pathologic cardiotocogram there is no concrete clinical evidence of manifest danger of hypoxia. II. Investigations concerning the practical importance of monitoring the fetus during labor were often not based on actual clinical indications. Attempts were made to prove that continuous electronic monitoring of the fetal heart rate could be replaced by simple traditional auscultation. Furthermore due to failure to appreciate the real efficiency of cardiotocography, this truly excellent method was in fact blamed for the faults arising from wrong interpretation, instead of underlining the lack of logic of the investigators concerned. After all, several prospective studies, that have examined the efficiency of various monitoring strategies, demonstrate the shortcomings of these techniques in the clinical setting and have shown them to have no relevance in every practice. Presently the most suitable way to monitor the fetus during labor is to combine cardiotocography with a biochemical method. At the moment fetal blood analysis is the most suitable test to be performed in cases where the cardiotocogram is not normal. Then the role of fetal blood analysis is to find out whether in fact a danger of hypoxia is threatened or not. Today the most urgent task when monitoring the fetus during labor is not so much to reduce the number of cases of cerebral palsy since these are seldom caused by intrapartum asphyxia. The major objective is now recognised to be to prevent early morbidity of the fetus, newborn, and the consequences that flow from this. The excellent results of combined intensive monitoring of the fetus during labor are particularly well illustrated by the intrapartum mortality in our hospital during different periods when monitoring practice has been progressively and methodically improved by stages. During the period when monitoring consisted of simple auscultation used on its own, the intrapartum mortality was 0.56%. After the introduction of fetal blood analysis--at that time cardiotocography did not yet exist--the mortality sank to 0.32%. During the first ten years of cardiotocography combined with fetal blood analysis the mortality reduced further to 0.17%, and during the following 13 years it reached to a minimal level of 0.4%. Finally, in this review, other aspects are commented on such as oximetry. Oximetry, presently used as pulse oximetry, as an additional biochemical method will possibly be incorporated as the third method of monitoring the fetus during labor. Oximetry could also be used as an automatic alarm system in the labor ward when fetal O2 levels drop below a particular limit to draw the attention of the staff to the case concerned. Up to now this has not been convincingly achieved with the use of cardiotocography.

Cardiotocography↗

Fetal electrocardiogram plus heart rate recording for fetal monitoring during labour.

BACKGROUND: It is thought that adding fetal electrocardiography (ECG) to cardiotocography (CTG) alone may provide better information about fetal heart activity. OBJECTIVES: The objective of this review was to assess the effects of simultaneous recording of fetal electrocardiographic waveforms plus conventional cardiotocography, with cardiotocography alone, during labour. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group trials register. SELECTION CRITERIA: Randomised trials of electrocardiogram waveform analysis with or without cardiotocography during labour. DATA COLLECTION AND ANALYSIS: Trial quality was independently assessed by two reviewers. Data extraction was done by one reviewer and checked by the second reviewer. Study authors were contacted for additional information. MAIN RESULTS: One study of 2434 pregnant women was included. This trial was of sound methodological quality. The number of operative deliveries for fetal distress was reduced by half in the electrocardiographic waveform and cardiotocography group (odds ratio 0.53, 95% confidence interval 0.39 to 0.73). There was no apparent effect on the rate of operative delivery for poor progress of labour (odds ratio 1.05, 95% confidence interval 0.87 to 1.27). The use of the electrocardiographic waveform analysis monitor had no obvious effect on the condition of the newborn. REVIEWER'S CONCLUSIONS: Analysis of the fetal electrocardiographic waveform during labour may be associated with reduced obstetric intervention without jeopardising fetal outcome.

Cardiotocography↗

Fetal electrocardiography in labor and neonatal outcome: data from the Swedish randomized controlled trial on intrapartum fetal monitoring.

OBJECTIVE: Cardiotocography plus automatic ST analysis of the fetal electrocardiography has been shown recently to reduce both the operative delivery rate for fetal distress and the cord artery metabolic acidosis rate. The purpose of this study was to analyze findings that were related to cases with a complicated/adverse neonatal outcome in the Swedish randomized controlled trial. STUDY DESIGN: Of the 4966 term fetuses that were included in the trial, all 351 newborn infants who required special neonatal care were identified. Cases of perinatal death, neonatal encephalopathy, or metabolic acidosis at birth were reviewed. RESULTS: Of the 29 fetuses with adverse/complicated neonatal outcome, 22 fetuses had cardiotocography and ST patterns that indicated a need for intervention, according to the cardiotocography plus ST clinical guidelines. The number of live-born with moderate or severe neonatal encephalopathy showed a significant decrease from 0.33% (8/2447 fetuses) in the cardiotocography-only group to 0.04% (1/2519 fetuses) in the cardiotocography plus ST group. CONCLUSION: Cardiotocography plus ST analysis provides accurate information about intrapartum hypoxia and may prevent intrapartum asphyxia and neonatal encephalopathy by giving a clear alert to the staff members who are in charge.

Acidosis↗

Fetal vibroacoustic stimulation for facilitation of tests of fetal wellbeing.

BACKGROUND: Acoustic stimulation of the fetus has been suggested to improve the efficiency of antepartum fetal heart rate testing. OBJECTIVES: The objective of this review was to assess the merits or adverse effects of the use of fetal vibroacoustic stimulation in conjunction with tests of fetal wellbeing. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group trials register. Date of last search: October 2000. SELECTION CRITERIA: All published and unpublished randomized controlled trials assessing the merits of the use of fetal vibroacoustic stimulation in conjunction with tests of fetal wellbeing. DATA COLLECTION AND ANALYSIS: Both reviewers independently extracted data and assessed trial quality. Authors of published and unpublished trials were contacted for further information. MAIN RESULTS: A total of seven trials with a total of 4325 participants were included. Fetal vibroacoustic stimulation reduced the incidence of non-reactive antenatal cardiotocography test (odds ratio (OR) 0.61, 95% confidence interval (CI) 0.49-0.75) and reduced the overall mean cardiotocography testing time (weighted mean difference (WMD) -4.55 minutes, 95% CI -5.96 minutes to -3.14 minutes). Vibroacoustic stimulation evoked more than mock stimulation when used in conjunction with fetal heart rate testing (OR 0.08, 95% CI 0.06-0.12). REVIEWER'S CONCLUSIONS: Vibroacoustic stimulation offers benefits by decreasing the incidence of non-reactive cardiotocography and reducing the testing time. Further randomized trials should be encouraged to determine not only the optimum intensity, frequency, duration and position of the vibroacoustic stimulation, but also to evaluate the efficacy, predictive reliability, safety and perinatal outcome of these stimuli with cardiotocography and other tests of fetal wellbeing.

Acoustic Stimulation↗

The monitoring of labor by telemetry.

Telemetry and conventional cardiotocography were compared by monitoring the labor of 60 patients with an uneventful pregnancy and delivery in the 38th-42nd week of pregnancy. 31 patients were monitored by telemetry and 29 by cardiotocography. The patients were matched for age (+/- 5 years), duration of pregnancy (+/- 7 days) and parity (I or II). The husband attended labor and delivery in 42% of the cases in the telemetry group and in 59% of the cases in the control group. Induction of labor by amniotomy was performed in 32% of the cases in the telemetry group and in 24% of the cases in the cardiotocography group. The patients monitored subjective pain every half hour during the opening phase. The telemetric patients were encouraged to sit or walk during the first stage. No maternal or fetal complications occurred. All infants were born in good condition with APGAR scores greater than or equal to 7 recorded at one and five minutes. There were 4 operative deliveries in the telemetry group and 5 in the control group. Indications for these were maternal or uterine exhaustion with the exception of two control patients where fetal asphyxia was suspected. The duration of the first stage of labor did not differ significantly between the telemetry and the cardiotocography groups. The telemetric patients received less analgesics than the controls but this difference was not significant. In spite of less analgesia in the telemetry group, the secondparas of the telemetry group experienced significantly less (p less than 0.01) labor pain than the controls. In addition, the secondparas of the telemetry group considered the present labor less painful than the previous one significantly more often than the controls. Among the primiparous patients there was no difference in the amount of pain experienced by the patients.

Adult↗

Maternal glucose administration for facilitating tests of fetal wellbeing.

BACKGROUND: Antenatal maternal glucose administration has been suggested to improve the efficiency of antepartum fetal heart rate testing. OBJECTIVES: The objective of this review was to assess the merits or adverse effects of antenatal maternal glucose administration in conjunction with tests of fetal wellbeing. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group trials register in June 2001. SELECTION CRITERIA: All published and unpublished randomized controlled trials assessing the merits of antenatal maternal (oral or intravenous) glucose administration in conjunction with tests of fetal wellbeing. DATA COLLECTION AND ANALYSIS: Both reviewers independently extracted data and assessed trial quality. Authors of published and unpublished trials were contacted for further information. MAIN RESULTS: A total of two trials with a total of 708 participants were included. Antenatal maternal glucose administration did not decrease the incidence of non-reactive antenatal cardiotocography tests. REVIEWER'S CONCLUSIONS: Antenatal maternal glucose administration has not been shown to reduce non-reactive cardiotocography. More trials are needed to further substantiate this and to determine not only the optimum dose, but also to evaluate the efficacy, predictive reliability, safety and perinatal outcome of glucose administration in conjunction with cardiotocography and also other tests of fetal wellbeing.

Administration, Oral↗

Digital communication with fetal monitors.

BACKGROUND: Fetal heart rate (FHR) values in the averaged format that are provided by commercial computed cardiotocography analysis systems may be unsuitable for special analysis purposes. METHOD: I developed a communication software program to obtain any measured values of fetal monitors for individual analysis of computed cardiotocography. EXPERIENCE: The software program was used to study the data continuity of beat-to-beat FHR values as an experiment for chaos theory and power spectrum analysis. The results indicated that the signal loss was recognized at a precision of 95%. CONCLUSION: The described method of digital communication with fetal monitors was found to be useful for individual purposes in the field of computed cardiotocography analysis.

Algorithms↗

The relative risk of 'fetal distress' in pregnancy associated with meconium-stained liquor at different gestation.

Pregnancies complicated with meconium-stained liquor are regarded as at risk of fetal distress. Evidence from animal and human studies indicate that passage of meconium may be related to fetal maturity. This retrospective study attempts to quantify the relative risk of non-reassuring cardiotocography or 'fetal distress' in pregnant women complicated by meconium-stained liquor for preterm, term and post-term pregnancies. A total of 9542 singleton pregnancies, delivered in a tertiary obstetric unit in Hong Kong between 1 July 1996 and 31 June 1999, were included in the study. Of these pregnancies, 1946 (20.4%) were identified as having meconium-stained liquor, ranging from thin to thick staining. There was a strong association between incidence of meconium-stained liquor (P < 0.0005) and moderate/thick meconium-stained liquor with advanced gestational age. The incidence of non-reassuring cardiotocography in women presenting with meconium-stained liquor was significantly higher (9.8% vs. 6.4%). The relative risk of non-reassuring cardiotocography in women with meconium-stained liquor increased with more advanced gestation. Close fetal surveillance during labour is required among these pregnancies. Premature labour is associated with higher incidence of fetal distress but the presence of meconium did not pose an additional risk.

Amniotic Fluid↗

Prediction of fetal outcome by Doppler examination and by the non-stress test.

Ninety-four women with high-risk pregnancies were referred to the Aker University Hospital, Department of Obstetrics, and monitored by Doppler velocimetry and conventional cardiotocography. The peak systolic/end diastolic (A/B) ratio was measured in the velocity waveform obtained in the umbilical artery blood flow. The non-stress test (NST) was classified according to the Fischer scores. In this mixed group of high-risk pregnancies, the sensitivity of the A/B ratio to predict fetal growth retardation was 71%, predictive value 57% and specificity 77%. The corresponding values for NST were 39%, 65% and 90%. It is concluded that Doppler velocimetry is more sensitive than cardiotocography for identifying fetal growth retardation. In an attempt to further improve the detection rate of fetal pathology, the cases with abnormal NST scores were added to those with high A/B ratios and collectively defined as abnormal. In consequence, only an insignificant improvement in sensitivity (79%) could be achieved. When the A/B ratio is normal, there seems little justification for expending time, effort and resources in routine use of cardiotocography.

Blood Flow Velocity↗

[Evaluation of the cardiotocographic specificity in antepartum diagnosis].

BACKGROUND: In last years, pregnancies and deliveries carefully monitorized, have led to perinatal mortality decrease. The more common diagnostic method used to point out fetal distress is cardiotocography, which is carried out as a routine screening during pregnancy and labor. The importance of cardiotocography, the limitations of this of measurement of fetal heart rate (FHR) are highlighted: no decrease in neurologic sequelae, positive and/or negative falses, dependence in interpretation on clinicians' experience. Our search aimed at checking the specificity of electronic fetal monitoring of fetal hearth rate at antepartum diagnosis moment. METHODS: 53 pregnant women in the third trimester of gestation period have been studied and the pregnancies results have been compared with specific women CTG trace and results of other diagnostic method (Ultrasound, Velocimetry). RESULTS: Analysing our data we find out that diagnostic methods of fetal distress, at present, are not significative. CONCLUSIONS: To sum up, it is possible to confirm that cardiotocography has a low specificity in fetal distress diagnosis, although it remains the most reliable method. In any case a global evaluation is necessary to monitorize pregnancy by means of clinical screening ordinary used.

Cardiotocography↗

[Clinical considerations on oligohydramnios].

BACKGROUND: Oligohydramnios represents a physiopathologic process, associated to a high rate of pregnancy complications and increased fetal morbidity and mortality. The purpose of this study is to determine whether amniotic fluid ultrasound evaluation is a useful parameter to identify pregnancies at risk for fetal distress. METHODS: 91 pregnant women with oligohydramnios were followed, and fetal conditions monitored with cardiotocography and ultrasounds. Delivery way and new-born conditions at birth were considered too. RESULTS: Cardiotocograms appeared abnormal in 61 cases (67%). Intrauterine growth restriction (IUGR) observed in 36 cases (39.56%). Cesarean section was performed in 60 cases (66%) for fetal distress, identified with cardiotocography. Also significant was the correlation with oligohydramnios, IUGR and cardiotocographic anomalies. From the results, it may be inferred that oligohydramnios is an index of affected fetal good health, because frequently is related with pregnancy anomalies and fetal health involvement. CONCLUSIONS: We can then affirm that the ultrasound evaluation of amniotic fluid represents a useful means to identify pregnancies at risk for fetal distress. In case of oligohydramnios, it is important to increase the surveillance on fetus, with the different means at our disposal (ultrasonography, velocimetry, cardiotocography).

Cardiotocography↗

[The cardiotocographic service during pregnancy. Reports on operative procedures used at different centers of the National area].

BACKGROUND: Aim of the paper is to verify the presence of operative procedures and their differences in the use of cardiotocography during pregnancy by some sample Centres in the national area. METHODS: From the year-book AOGOI 1997, 50 Operative Units of Obstetrics and Gynecology were chosen and sent a questionnaire, duly prepared, in order to get the following information: presence of a specific Cardiotocographic Service during pregnancy and its supply; number of patients and way of making appointments; duration and frequency of controls; type of reporting; type of cardiotocographs used; behaviour in emergency cases and possible combined diagnostics. RESULTS: Most of the Centres interviewed (64%) have their own Cardiotocographic Service which may be used in the morning by appointment. The patients have generally physiological pregnancies at term. Some differences were observed among the Centres concerning the period of the first control and the frequency of the following ones. The average number of antepartal non-stress tests has been of 3.9 with a very wide range (1-10). Only in 23.5 and in 12.7% of the cases a cardiotocographic control is required starting from the 40th and 41st week respectively. In the remaining cases (63.8%) controls are to be effected between the 34th and the 39th week. The average duration of the cardiotocographic recording changes if computerized appliances are used; in any case, the most likely duration is between 21 and 30 minutes. Doubtful reports per year were more when using non-computerized cardiotocography (10.8% vs 7.08%). In most of the Centres, a system of reporting on a final evaluating form, enclosed to the cardiotocogram, is used and in 72% of the cases the Centre may give an echographic and echofluximetric combined evaluation. Almost the total of the sample interviewed solved the problem of "emergencies" by entrusting the medical and paramedical staff of the Obstetrics Department, with controls. CONCLUSIONS: Antepartal Cardiotocography has nowadays become a means of control widely spread also in physiological pregnancy. In fact, most of the sample Centres have their own ambulatory Service. The same operative procedures were not followed by these Services and the solution of running problems (admission of users) varies in each Centre according to the number of users and the availability of means and staff.

Cardiotocography↗

[Predictive factors of infantile cerebral lesions during pregnancy and labor].

The risks connected with children's cerebral lesions are examined by means of two different surveys related to a retrospective study over a period of about 10 years. One of these surveys is clinical and is based in the obstetric case history of children carrying psychomotor handicaps. The other survey is instrumental and concerns 100 cases of pathologic cardiotocography during labour associated with fetal suffering. The results of border surveys are discusses. For the assessment of the obstetric risk the sum of the pathologic conditions that emerged during pregnancy and delivery have to be taken into consideration. Cardiotocography is still a fundamental diagnostic examination to recognise the suffering fetus and the data collected real a close association between cardiotocography diagnosis and the conditions of the baby at the birth.

Brain Damage, Chronic↗

Fetal manipulation for facilitating tests of fetal wellbeing.

BACKGROUND: Manual fetal manipulation has been suggested to improve the efficiency of antepartum fetal heart rate testing. OBJECTIVES: The objective of this review was to assess the merits or adverse effects of the use of manual fetal manipulation in conjunction with tests of fetal wellbeing. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group trials register in June 2001. SELECTION CRITERIA: All published and unpublished randomized controlled trials assessing the merits of the use of fetal manipulation in conjunction with tests of fetal wellbeing. DATA COLLECTION AND ANALYSIS: Both reviewers independently extracted data and assessed trial quality. Authors of published and unpublished trials were contacted for further information. MAIN RESULTS: Only two trials with a total of 1090 women with 2110 episodes of participation were included. Manual fetal manipulation did not decrease the incidence of non-reactive antenatal cardiotocography test (odds ratio 1.28 confidence interval 0.94-1.74). REVIEWER'S CONCLUSIONS: Manual fetal manipulation has not been shown to reduce the incidence of non-reactive cardiotocography. Trials of manual fetal manipulation should take into consideration that there have not been any benefits demonstrated as yet.

Abdomen↗

Validity of the Hewlett-Packard actograph in detecting fetal movements.

OBJECTIVE: To detect fetal movements during non-stressed cardiotocography to evaluate the validity of the Hewlett-Packard Doppler ultrasound actograph in detecting fetal movements. METHODS: This was a prospective, observational study. Thirty healthy pregnant women were divided into two gestational age groups (Group I, 31 + 0 to 34 + 0 weeks, n = 15; Group II, 37 + 0 to 40 + 0 weeks, n = 15). A Hewlett-Packard M-1350-A actocardiograph was used to make recordings of 45 min for each woman. Fetal movements were also detected sonographically by an observer and they were recorded independently by the pregnant woman. Ninety consecutive 30-s periods were analyzed to study agreement between the three techniques. RESULTS: The mean total agreement for fetal activity plus quiescence between ultrasound and the actograph was 63.7% for Group I, and 72.2% for Group II. In cases of fetal activity only, these values were 45.8% and 47.6%, respectively. Total agreements between ultrasound and the pregnant woman were 74.0% and 79.0%, respectively, for Groups I and II. Cohen's kappa values for total agreement between ultrasound and actograph were 0.31 (95% CI, 0.27-0.36), indicating 'fair' agreement in Group I, and 0.43 (95% CI, 0.38-0.47), indicating 'moderate' agreement in Group II. CONCLUSIONS: Use of the Hewlett-Packard actograph may offer some additional information during routine cardiotocography. However, our results were disappointing; the technique appears not to be suitable for detailed recordings of fetal behavior, and may even be misleading when difficult cardiotocographic patterns have to be interpreted.

Adult↗

Prognostic value of umbilical-middle cerebral artery pulsatility index ratio in fetuses with growth restriction.

OBJECTIVE: To study the utility of Doppler velocimetry and computerized cardiotocography in the management of intrauterine growth restriction and prediction of neonatal outcome. PATIENTS AND METHODS: Seventy-two pregnant women with fetuses showing growth restriction and delivered within 48 h of their last Doppler velocimetry evaluation. The last computerized cardiotocographic trace from these fetuses was used for statistical analysis, and the last trace from the healthy fetuses of 93 consecutive women undergoing cesarean section was used as control. Umbilical artery pulsatility index (UA PI), middle cerebral artery pulsatility index (MCA PI), UA PI/MCA PI ratio, and uterine artery resistance index (Ut RI) were assessed. RESULTS: Among women with growth-restricted fetuses, all parameters were significantly higher in those who had hypertension; and in those who had diabetes, only the UA PI/MCA ratio was significantly higher. Umbilical artery PI values and the UA PI/MCA ratio were higher in those who had a nonreassuring result to computerized nonstress test immediately before delivery. A multiple logistic analysis showed that the UA PI/MCA ratio was the only Doppler velocimetry parameter predicting cardiotocographic nonreactivity; furthermore, the predictivity of extended newborn hospitalization (longer than 15 days) was verified, with a sensitivity of 56% and a specificity of 92% when the ratio was higher than 1.26. CONCLUSION: The MCA PI of fetuses with growth restriction should be assessed. The UA PI/MCA ratio is predictive of a nonreactive computerized cardiotocography trace and of prolonged neonatal hospitalization.

Adult↗

Developments in CTG analysis.

FHR monitoring has been the subject of many debates. The technique, in itself, can be considered to be accurate and reliable both in the antenatal period, when using the Doppler signal in combination with autocorrelation techniques, and during the intrapartum period, in particular when the FHR signal can be obtained from a fetal ECG electrode placed on the presenting part. The major problems with FHR monitoring relate to the reading and interpretation of the CTG tracings. Since the FHR pattern is primarily an expression of the activity of the control by the central and peripheral nervous system over cardiovascular haemodynamics, it is possibly too indirect a signal. In other specialities such as neonatology, anaesthesiology and cardiology, monitoring and graphic display of heart rate patterns have not gained wide acceptance among clinicians. Digitized archiving, numerical analysis and even more advanced techniques, as described in this chapter, have primarily found a place in obstetrics. This can be easily explained, since the obstetrician is fully dependent on indirectly collected information regarding the fetal condition, such as (a) movements experienced by the mother, observed with ultrasound or recorded with kinetocardiotocography (Schmidt, 1994), (b) perfusion of various vessels, as assessed by Doppler velocimetry, (c) the amount of amniotic fluid or (d) changes reflected in the condition of the mother, such as the development of gestation-induced hypertension and (e) the easily, continuously obtainable FHR signal. It is of particular comfort to the obstetrician that a normal FHR tracing reliably predicts the birth of the infant in a good condition, which makes cardiotocography so attractive for widespread application. However, in the intrapartum period, many traces cannot fulfil the criteria of normality, especially in the second stage. In this respect, cardiotocography remains primarily a screening and not so much a diagnostic method. As long as continuous monitoring of fetal acid-base balance has not been extensively tested in clinical practice, microblood sampling of the fetal presenting part (Saling, 1994) is a useful adjunct. The problem with non-normal tracings is that their significance is very often unclear. They may indicate serious fetal distress, finally resulting in preventable destruction of critical areas in the fetal brain and damage to various organs; or, on the contrary, they may indicate temporary changes in cardiovascular control as a reaction to the intermittent effects on fetal haemodynamics of, for example, uterine contractions, whether or not in combination with partial or complete compression of umbilical cord vessels or the vessels on the chorionic plate (van Geijn, 1994). Many factors influence the FHR and its variability, which further complicates the interpretation of FHR patterns; some have been discussed here in some detail. Undoubtedly, there is a need for quantitative and objective FHR analysis, as long as it does not lead to erroneous results. Close collaboration between engineers and clinicians is a prerequisite for further advances in this field. Decision support systems certainly have a future but only if they are able to take into account a large set of clinical data and can combine it with data obtained from FHR signals and other parameters referring to the fetal condition, such as fetal growth, Doppler velocimetry, amniotic fluid volume and biochemical and biophysical data obtained from the mother. Basic technical concepts inherent in computerized CTG analysis, such as sampling rate (Chang et al, 1995), signal loss, artefact detection (van Geijn et al, 1980), further processing of intervals, archiving in digitized format and monitor display, should receive considerable attention. There is still a long way to go until decision support systems find their way into obstetric practice. Further developments can only be achieved thanks to efforts of many basic and clinical researchers, wo

Auscultation↗

Maternal perceptions of labor with fetal monitoring by pulse oximetry in a research setting.

OBJECTIVE: Little research has evaluated maternal experience with fetal pulse oximetry for fetal surveillance. The purpose of this study was to compare maternal perceptions of labor with intrapartal cardiotocography with or without fetal pulse oximetry in a research setting. METHODS: One hundred women with vaginal, vertex deliveries and uncomplicated fetal outcomes were enrolled. The study group was a subset of 50 mothers who had participated in a pulse oximetry trial. The control group of 50 mothers was monitored by cardiotocography only. Both groups were matched for age, parity, weeks of gestation, epidural anesthesia use, and duration of labor. A global measure of maternal perception of labor was established by experience with labor, general attitude toward monitoring devices, satisfaction with monitoring, nursing and medical care, and anxiety, each of which was evaluated separately. The mothers in the study group were also interviewed about aspects related to the fetal pulse oximetry research setting, such as information, movement restriction, discomfort, care, privacy, and safety. The questionnaires were based on a standardized rating scale model, and the interviews were conducted two to four days after delivery. The results were analyzed by chi-squared, paired t test, and ANOVA. RESULTS: No significant differences were observed between the study and control participants in any parameter concerning the maternal perception of labor. Mothers' experiences with pulse oximetry as assessed by interview was overwhelmingly positive. CONCLUSIONS: Fetal monitoring by pulse oximetry in a research setting did not affect maternal perceptions of labor. Mothers' experiences with pulse oximetry were highly positive, suggesting that research in fetal pulse oximetry need not compromise maternal perceptions of labor.

Adult↗