Developments in CTG analysis.

Abstract

FHR monitoring has been the subject of many debates. The technique, in itself, can be considered to be accurate and reliable both in the antenatal period, when using the Doppler signal in combination with autocorrelation techniques, and during the intrapartum period, in particular when the FHR signal can be obtained from a fetal ECG electrode placed on the presenting part. The major problems with FHR monitoring relate to the reading and interpretation of the CTG tracings. Since the FHR pattern is primarily an expression of the activity of the control by the central and peripheral nervous system over cardiovascular haemodynamics, it is possibly too indirect a signal. In other specialities such as neonatology, anaesthesiology and cardiology, monitoring and graphic display of heart rate patterns have not gained wide acceptance among clinicians. Digitized archiving, numerical analysis and even more advanced techniques, as described in this chapter, have primarily found a place in obstetrics. This can be easily explained, since the obstetrician is fully dependent on indirectly collected information regarding the fetal condition, such as (a) movements experienced by the mother, observed with ultrasound or recorded with kinetocardiotocography (Schmidt, 1994), (b) perfusion of various vessels, as assessed by Doppler velocimetry, (c) the amount of amniotic fluid or (d) changes reflected in the condition of the mother, such as the development of gestation-induced hypertension and (e) the easily, continuously obtainable FHR signal. It is of particular comfort to the obstetrician that a normal FHR tracing reliably predicts the birth of the infant in a good condition, which makes cardiotocography so attractive for widespread application. However, in the intrapartum period, many traces cannot fulfil the criteria of normality, especially in the second stage. In this respect, cardiotocography remains primarily a screening and not so much a diagnostic method. As long as continuous monitoring of fetal acid-base balance has not been extensively tested in clinical practice, microblood sampling of the fetal presenting part (Saling, 1994) is a useful adjunct. The problem with non-normal tracings is that their significance is very often unclear. They may indicate serious fetal distress, finally resulting in preventable destruction of critical areas in the fetal brain and damage to various organs; or, on the contrary, they may indicate temporary changes in cardiovascular control as a reaction to the intermittent effects on fetal haemodynamics of, for example, uterine contractions, whether or not in combination with partial or complete compression of umbilical cord vessels or the vessels on the chorionic plate (van Geijn, 1994). Many factors influence the FHR and its variability, which further complicates the interpretation of FHR patterns; some have been discussed here in some detail. Undoubtedly, there is a need for quantitative and objective FHR analysis, as long as it does not lead to erroneous results. Close collaboration between engineers and clinicians is a prerequisite for further advances in this field. Decision support systems certainly have a future but only if they are able to take into account a large set of clinical data and can combine it with data obtained from FHR signals and other parameters referring to the fetal condition, such as fetal growth, Doppler velocimetry, amniotic fluid volume and biochemical and biophysical data obtained from the mother. Basic technical concepts inherent in computerized CTG analysis, such as sampling rate (Chang et al, 1995), signal loss, artefact detection (van Geijn et al, 1980), further processing of intervals, archiving in digitized format and monitor display, should receive considerable attention. There is still a long way to go until decision support systems find their way into obstetric practice. Further developments can only be achieved thanks to efforts of many basic and clinical researchers, wo

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H P Van Geijn. 1996. Developments in CTG analysis.. https://doi.org/10.1016/s0950-3552(96)80033-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transmission of lung sounds through light clothing.

BACKGROUND: Doctors are exhorted to always place the stethoscope directly on the skin and never to auscultate through clothing. Nevertheless, casual observation reveals that doctors and even pulmonologists often violate this principle. OBJECTIVES: This study was designed to evaluate the sensitivity of two common stethoscopes when used through clothing. METHODS: Littmann Classic and Littmann Master Cardiology stethoscopes were studied under conditions of light (60-100 g), medium (240 g) and heavy (555 g) force when placed on a lung sound test platform with one or two layers of cloth (T-shirt material and flannel) interposed between the stethoscope and the test surface. The test platform was designed to mimic the acoustic and mechanical properties of the chest wall and was driven by amplified white noise. The recorded amplitude spectra were compared over a range of 150-1,000 Hz. RESULTS: Compared to the sensitivity on a bare test platform surface, either fabric in single or double layers attenuated the sounds by a mean of 5-18 dB under light pressure. This attenuation was nearly abolished by the addition of either medium or heavy force on the stethoscope head. CONCLUSIONS: The deleterious effect of one or two layers of indoor clothing on lung sounds acquired through a stethoscope can be negated by force on the stethoscope head making effective auscultation possible. Nevertheless, auscultation through clothing remains problematic due to the hindrance to inspection and percussion and the risk of acoustic artifacts caused by clothing.

Auscultation↗

A huge obstructive myxoma located in the right heart without causing any symptom.

Cardiac myxoma is unusual and mostly located in left atrium. Although it is a benign tumor of the heart, it may cause life-threatening cardiac problems like valvular obstruction, systemic or pulmonary massive embolism, infection, arrhythmia, malignance. We report a huge cardiac myxoma originated from right atrium. It was moving between right atrium and ventricle without any symptoms.

Auscultation↗