Search PubMedSearch

SEARCH · Search PubMed

Results for “Physiological parameters”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

435 records · Page 17Linked to original sources

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

The knee-ankle link: impact of knee varus severity on distal joint malalignment and concomitant pathologies.

BACKGROUND: Knee varus deformity is traditionally managed as an isolated joint pathology; however, persistent distal symptoms following proximal realignment suggest a more extensive kinetic chain dysfunction. The degree to which knee varus severity dictates distal malalignment and secondary pathologies remains poorly quantified in the current literature. METHODS: This systematic review and meta-analysis were conducted in accordance with PRISMA 2020 guidelines (PROSPERO: CRD420261363327). A comprehensive search of PubMed, Embase, Web of Science, and the Cochrane Library was performed from inception to April 2026. Studies examining the relationship between knee varus (HKA angle) and radiographic distal alignment or pathologies were included. Data synthesis utilized random-effects models, with prevalence analyzed via generalized linear mixed models (GLMM). RESULTS: Fourteen studies were included in the final synthesis. While pooling of continuous radiographic parameters was limited by high statistical heterogeneity in Talar Tilt (I2 = 96.5%), individual large-cohort data (Huang et al.) indicated that severe knee varus (HKA > 10°) was associated with increased odds of concomitant ankle osteoarthritis (OR 2.29; 95% CI 1.28-4.11) and a specific cohort prevalence of 37.1%. Furthermore, single-arm prevalence data revealed divergent trends across different study populations, with compensatory hindfoot valgus reaching 69.9% in some cohorts and rigid varus up to 63.9% in others. CONCLUSIONS: Severe genu varum is associated with distal kinetic chain alterations and concomitant ankle pathologies. However, due to the extreme heterogeneity and divergent distal adaptations observed across different cohorts, standardized knee-centric protocols may be insufficient. Further longitudinal and interventional studies are required to establish phenotype-specific rehabilitation guidelines.

Humans

ReMeDy: A Flexible Statistical Framework for Region-Based Detection of DNA Methylation Dysregulation.

Region-based epigenome-wide association studies have demonstrated improved statistical power and biological interpretability compared with probe-wise analyses of DNA methylation data. However, most existing region-based methods characterize methylation dysregulation primarily through changes in mean methylation levels associated with a phenotype of interest. Substantial evidence indicates that phenotype-associated methylation alterations may also manifest through changes in methylation variability or through joint shifts in mean and variability. Despite this, no existing statistical framework jointly models mean-variance methylation changes in a region-based manner. We propose ReMeDy, a flexible statistical framework that uses a hierarchical likelihood approach within a generalized linear model setting to identify differentially methylated regions, variably methylated regions, and regions exhibiting joint differential and variable methylation at a genome-wide scale. Unlike existing models, ReMeDy operates directly on biologically defined co-methylated regions, allowing it to naturally capture spatial correlation inherent in DNA methylation array data, while avoiding reliance on heuristic, user-defined tuning parameters such as smoothing spans and kernel bandwidths that can substantially influence results and introduce subjectivity. Through extensive simulation studies and comprehensive benchmarking against popular models, we demonstrate that ReMeDy maintains false discovery and Type-I error rates at nominal levels while achieving consistently higher statistical power across a wide range of realistic scenarios. Application to population-level DNA methylation data further shows that ReMeDy identifies biologically meaningful regions and pathways implicated in complex human diseases that are not captured by conventional mean-based analyses alone. ReMeDy is implemented as an open-source R package and is freely available at https://github.com/SChatLab/ReMeDy.

DNA Methylation

Development of a cell-based nanoluciferase reporter system for high-throughput screening of HBV cccDNA inhibitors.

Hepatitis B virus (HBV) persistence is sustained by the viral covalently closed circular DNA (cccDNA) minichromosome, which remains a major barrier to curative antiviral therapies. The lack of reliable quantitative cccDNA detection methods and surrogate markers has hindered efforts to target cccDNA in antiviral high-throughput screening (HTS). Here, we established a novel inducible cccDNA-dependent nanoluciferase (NLuc) reporter cell line, designated HepBLE12, by inserting an in-frame 11-amino acid split-NLuc HiBiT tag into the precore (pC) coding region of an HBV transgene. The resulting 1.3-kDa HiBiT tag on pC serves as the detection module of the split NLuc system, generating quantitative luminescence upon high-affinity complementation with the cognate 18-kDa LgBiT subunit in cell lysates. Notably, the HiBiT assay enables direct detection of intracellular HiBiT-pC protein rather than secreted HBeAg, providing a reporter signal more closely linked to cccDNA activity. HepBLE12&#x202f;cells exhibited inducible and robust viral DNA replication, and the cccDNA-dependent HiBiT signal was validated under diverse experimental conditions that modulate cccDNA formation or transcription. We further miniaturized the assay to a 384-well format and optimized key parameters following standard HTS assay development practices. The assay was successfully automated and demonstrated excellent performance in a multi-day variability study and a pilot screen, with signal-to-background (S/B)&#x202f;&#x2248;&#x202f;9, coefficient of variance (CV)&#x202f;<&#x202f;10%, and average Z-factor value of 0.74, exceeding canonical HTS quality benchmarks. Together, the HepBLE12 cell-based HTS platform provides a robust and practical tool for identifying inhibitors targeting HBV cccDNA.

Hepatitis B virus

Optimizing focal vibration therapy for balance and gait: A systematic review.

OBJECTIVE: This systematic review evaluated the efficacy of focal (localized) vibration therapy (FVT) applied to muscles/tendons on balance, gait, and mobility, with a specific focus on defining optimal vibration protocols (frequency, amplitude, dosing) and muscle-targeting strategies to maximize sensorimotor recovery. METHODS: A systematic review was conducted across six databases (CINHAL, Embase, Medline, Web of Science, Scopus, CENTRAL) from January 2000 to May 2025. Studies were included if they involved human participants, applied FVT therapeutically, and reported balance, gait, or mobility outcomes. Data extraction included study characteristics, intervention protocols, and outcomes. Methodological quality was assessed using the PEDro scale. RESULTS: Sixty-two studies (n&#x202f;=&#x202f;2090 participants) were included. Methodological quality assessment (PEDro scale) indicated 44% of studies met high-quality standards. Biomechanical analysis identified the quadriceps, gastrocnemius/soleus, and plantar muscles as the most effective vibration sites, given their critical roles in gait propulsion and postural stability. The synthesis of protocol data indicated a promising therapeutic window characterized by a vibration frequency of 80-120&#x202f;Hz (primarily fixed sinusoidal waveforms at a single frequency) and an amplitude of 0.2-0.5&#x202f;mm (reported only in 12 studies; amplitude was not reported in 23 studies), applied bilaterally for a minimum of 3 sessions per week over 4-12 weeks, which could lead to improved balance and gait performance with benefits sustained for up to 5 months. CONCLUSION: FVT shows potential to improve gait and balance, particularly when targeting lower-extremity muscles with optimized vibration parameters. To advance the field, future research must prioritize the development of standardized protocols and investigate neurophysiological mechanisms to refine FVT as a precision bioengineering solution for mobility deficits.

Humans

Macroprolactinemia as a diagnostic pitfall in hyperprolactinemia: a systematic review and quantitative synthesis.

CONTEXT: Macroprolactinemia is a well-recognized cause of hyperprolactinemia and an important diagnostic pitfall in endocrine practice. However, interpretation of published quantitative prolactin data remains sparse as studies vary in confirmation method, assay platform, polyethylene glycol (PEG) recovery cutoff, and reporting of prolactin measurement. EVIDENCE ACQUISITION: PubMed, Embase, Scopus, Web of Science, the Cochrane Library, and Google Scholar were systematically searched. Eligible studies reported macroprolactinemia-specific quantitative prolactin data in patients with confirmed macroprolactinemia defined by PEG precipitation, gel filtration chromatography (GFC), or both. Two reviewers independently performed study selection, data extraction, and quality assessment. Findings were summarized using study-level descriptive synthesis. The review was prospectively registered in PROSPERO and conducted in accordance with PRISMA 2020 guidelines. EVIDENCE SYNTHESIS: Forty-five studies encompassing 2853 macroprolactinemia cases from 21 413 screened patients with hyperprolactinemia across 22 countries were included. Among 33 studies eligible for primary quantitative analysis, the median study-level central total prolactin attributed to macroprolactinemia was 61.4 ng/mL ([IQR] 42.0-80.0; range 28.1-137.6), and the median study-level post-PEG monomeric prolactin was 11.7 ng/mL (IQR 8.3-13.2; range 4.0-17.0)). The median study-level maximum total prolactin was 264.5 ng/mL (IQR 97.0-425.5; range 81.8-663.0); extreme elevations were attributable to coexisting prolactinomas. CONCLUSION: In confirmed macroprolactinemia, total prolactin elevation is typically moderate, and post-PEG monomeric prolactin is usually within or near the normal range. The post-PEG monomeric prolactin value, rather than percent recovery alone, is the most informative parameter for distinguishing isolated macroprolactinemia from coexisting true hyperprolactinemia. These quantitative benchmarks may help clinicians to avoid unnecessary investigation or treatment.

Humans

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

The effects of visuomotor training and tDCS stimulation on visuomotor integration and visual processing: an electrophysiological approach.

BACKGROUND: Visuomotor integration coordinates visual and motor cortical activity to produce goal-directed responses and can be indexed by Rolandic Mu-rhythm suppression and visual evoked potential (VEP) P100 parameters. Perceptual-motor training improves visuomotor performance, and transcranial direct current stimulation (tDCS) over primary motor cortex (M1) has been reported to enhance motor learning when paired with training. This study examined whether anodal M1 tDCS augments the effects of Senaptec visuomotor training in healthy adults. METHODS: Sixty participants were randomized to active anodal tDCS (five 10-minute sessions, 1&#xa0;mA; n&#xa0;=&#xa0;31) or sham (n&#xa0;=&#xa0;29) over M1 immediately before each Senaptec training session; 53 completed all sessions and post-testing. Outcomes were Mu-suppression ratios, VEP P100 latency and amplitude, and Senaptec measures of visual sensitivity and visuomotor control. RESULTS: Active tDCS produced no augmentation of any outcome, with no significant group&#xa0;&#xd7;&#xa0;time interaction for any measure, consistent across composite and task-level analyses. Training alone produced no change in Mu suppression or visuomotor control. By contrast, both groups showed significant training-related gains in visual sensitivity, including near-far quickness and stereopsis, accompanied by shorter P100 latencies and larger amplitudes, indicating more efficient early visual processing. CONCLUSIONS: A clear dissociation emerged: training produced robust improvements in early visual processing, whereas neither tDCS nor training altered sensorimotor (Mu) or visuomotor-control measures. The tDCS results should be interpreted cautiously given the modest dose and limited power to detect small effects, rather than as evidence of inefficacy. Tablet-based perceptual training enhanced visual processing independent of neuromodulation.

Humans

Intraskeletal Variation in Cortical Bone Quantity in a Medieval Italian Sample: A Multivariate Exploratory Approach.

Bioarcheologists interpret skeletal health by examining variability within and between individuals. Studies of bone loss have generated contradictory and conflicting results regarding the onset and severity of age-related bone loss on a global and temporal scale, perhaps due to mismatched methodologies. Intraskeletal comparisons of bone tissue prove challenging precisely because of heterogeneous baselines in quantity and remodeling of cortical bone throughout the skeleton, as well as evolutionary histories and environmental impacts on growth and development. Here we analyze cortical bone indicators from the rib, metacarpal, and femoral cortical bone in a subset of individuals (n&#x2009;=&#x2009;72) regions from the medieval Italian archaeological site of Pieve di Pava. To facilitate intraskeletal comparisons across elements with different biological baselines, we standardize cortical bone parameters using z-scores. Variation in relative intraskeletal cortical bone was assessed using accessible multivariate methods (principal component analysis and hierarchical cluster analysis). Results suggest an association between femoral and metacarpal cortical bone values, with stochastic trends in metacarpal and femoral relative bone quantity in relation to the rib bone quantity at the sample level. Our study demonstrates that while intraskeletal analyses are challenging, they are made more robust by synthesizing multivariate methods alongside exploratory data analysis (EDA) methods to tack between sample-level and individual-level scales and variability. Ultimately, we advocate for leveraging multivariate techniques not as a final step, but rather as a means of generating new hypotheses and challenging tendencies to a priori establish typological groups in the research process.

Skeleton

Engineering copper ferrite (CuFe2O4) nanocomposites for enhanced eco-friendly photocatalysis: a systematic critical review on mechanisms, performance, and environmental applications.

Water pollution caused by organic and inorganic contaminants, particularly dyes and pharmaceuticals, represents a major environmental challenge. Advanced oxidation processes based on photocatalysts have emerged as efficient and sustainable approaches for water and wastewater treatment. Copper ferrite (CuFe2O4) is considered a promising photocatalyst owing to its narrow bandgap, visible-light activity, chemical stability, and magnetic properties. Despite extensive experimental investigations, a comprehensive systematic comparison of CuFe2O4-based photocatalysts under diverse operational conditions has remained limited. In this study, a systematic review following PRISMA guidelines was conducted using studies published between January 2014 and November 2025 indexed in Scopus, PubMed, Web of Science, and ScienceDirect. From an initial pool of 397 studies, 98 articles met the inclusion criteria. Key parameters&#xa0;-&#xa0;including pollutant type, pH, catalyst dosage, initial pollutant concentration, irradiation time, light source, and degradation efficiency&#xa0;-&#xa0;were quantitatively compared to identify performance trends and operational optima. The results demonstrate that CuFe2O4-based nanocomposites, particularly heterojunction, Z-scheme, and S-scheme architectures combined with TiO2, g-C3N4, graphene, and metal oxides, achieve high degradation efficiencies (often >90&#x202f;%) for a wide&#xa0;range of organic pollutants and selected inorganic contaminants (e.g., Cr(VI)). Enhanced charge separation and suppressed electron-hole recombination were identified as the primary factors contributing to improved photocatalytic activity. In addition, the intrinsic magnetic properties of these&#xa0;nanocomposites enable facile catalyst recovery and reuse. In conclusion, CuFe2O4-based nanocomposites, especially those&#xa0;incorporating advanced heterojunction architectures, emerge as highly efficient and magnetically recoverable photocatalytic platforms for sustainable water and wastewater treatment, with strong potential for scalable implementation and real-wastewater applications.

Catalysis

Extender-dependent effects of reduced glutathione on post-thaw boar sperm quality: A systematic review and meta-analysis.

Supplementation of reduced glutathione (GSH) in freezing media has been proposed to improve post-thaw boar sperm quality, although reported findings remain inconsistent. This study aimed to quantitatively evaluate the effects of reduced glutathione on post-thaw sperm quality through a systematic review and meta-analysis. The study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Scopus, PubMed, CAB Direct, EBSCOhost, and Google Scholar were systematically searched. Based on predefined inclusion and exclusion criteria, 15 in vitro studies comprising 19 experiments were included. Four outcomes were analyzed: total motility, progressive motility, viability, and acrosome integrity. Standardized mean differences (SMD) were calculated using random-effects models. Heterogeneity was assessed using Cochran's Q test, and the I2 statistic. Publication bias was evaluated using funnel plots, Egger's test, and trim-and-fill analysis, while sensitivity analyses were performed using Baujat plots and leave-one-out analysis. Reduced glutathione was positively associated with total motility (SMD = 0.74; 95% CI: 0.42-1.05; P<0.001), progressive motility (SMD = 0.90; 95% CI: 0.21-1.58; P=0.014), viability (SMD = 0.67; 95% CI: 0.11-1.23; P=0.022), and acrosome integrity (SMD = 0.72; 95% CI: 0.32-1.12; P=0.002). Low to high heterogeneity was observed across outcomes, indicating variability in the estimated effects across studies. Significant subgroup differences were identified according to GSH concentration, freezing media, and thawing media. Overall, the available evidence suggests a possible positive association between GSH supplementation and several post-thaw sperm quality parameters, although these subgroup findings are exploratory and require confirmation in well-standardized experimental studies.

Animals

Pharmacokinetics of injectable favipiravir: phase I, randomized, double-blind, placebo-controlled study in healthy East Asian subjects.

Favipiravir, an oral antiviral medication, has been approved in Japan for the treatment of patients with novel or re-emerging influenza and severe fever with thrombocytopenia syndrome (SFTS). Randomized, double-blind, placebo-controlled trials were conducted in an East Asian population to characterize the pharmacokinetics and tolerability of an injectable favipiravir formulation. In the single-ascending dose trial, subjects received a single intravenous (IV) dose of 300-2,400 mg of favipiravir. In the multiple dose trial, 1,800 mg was administered twice daily on the first day, followed by 800 mg twice daily for the subsequent 10 days, which is the approved tablet dose for SFTS in Japan. This multiple-dose trial was divided into a cohort receiving intravenous administration throughout the treatment period (IV cohort) and a cohort switching to oral administration from Day 6 (Switching cohort). After a single administration of &#x2264;2,400 mg, the pharmacokinetic parameters increased in a dose-dependent manner but showed slight deviation from linearity. The geometric mean maximum plasma concentration following a single 2,400&#x202f;mg dose was 126 (range: 110 to 138) &#x3bc;g/mL. In the IV cohort, the trough (at 12 h post-dose) plasma concentrations were maintained at approximately 85 &#x3bc;g/mL after Day 2. These concentrations were approximately 20% higher than those achieved with the same oral doses. In the Switching cohort, these concentrations were maintained throughout the treatment. No serious adverse events were observed. These findings support advancing injectable favipiravir into clinical evaluation.CLINICAL TRIALSThis study is registered with the Japan Registry of Clinical Trials as jRCT2071210042 and jRCT2071210126.

Humans

Effects of Sacubitril Valsartan Combined With Vericiguat on NT-proBNP and CK-MB Levels in Patients With Chronic Heart Failure.

This study aims to probe the influence of sacubitril valsartan sodium tablets combined with vericiguat on N-terminal pro-B-type natriuretic peptide (NT-proBNP) and creatine kinase isoenzyme (CK-MB) levels in patients with chronic heart failure (CHF). One hundred and twenty CHF patients were enrolled and stratified into a control group (sacubitril valsartan sodium tablets) and a combination group (sacubitril valsartan sodium tablets&#x2009;+&#x2009;vericiguat). Outcome measures included New York Heart Association (NYHA) functional class shifts, echocardiographic indices, cardiac injury markers, 6-min walk distance (6MWD), endothelial function parameters, inflammatory mediator levels, and adverse clinical events. Following a 6-month treatment period, patients in the combination group exhibited superior functional improvement, as reflected by greater advancement in NYHA class. Echocardiographic evaluation revealed more favorable ventricular remodeling in this group, with reduced left ventricular end-diastolic and end-systolic diameters and an elevated ejection fraction. The combination group had a higher 6MWD. Biomarker analysis showed lower NT-proBNP and CK-MB levels in the combination group. Furthermore, improvements in endothelial function were noted, with decreased endothelin and elevated NO, NOS, and CGRP levels in the combination group. Markers of systemic inflammation, including CRP and IL-6, were also attenuated in the combination group. The incidence of adverse reactions and cardiovascular events did not differ significantly between the groups. Co-administration of sacubitril/valsartan and vericiguat enhances cardiac performance, optimizes vascular endothelial responsiveness, modulates heart failure-related biomarkers, and mitigates inflammatory activity in patients with CHF without increasing the risk of adverse events.

Humans

Current Concepts and Emerging Technologies in Aesthetic Outcome Assessment of Breast Reconstruction.

Aesthetic outcomes are a crucial determinant of the overall success of breast reconstruction. Recently, aesthetic assessment has evolved from relying mainly on subjective impressions to incorporating more quantitative methods. This systematic review summarizes current concepts and emerging technologies in aesthetic outcome assessment after breast reconstruction. A comprehensive search of studies evaluating aesthetic outcomes following implant-based, autologous or hybrid breast reconstruction was performed between 2000 and 2025. Assessments were classified as subjective or objective. Extracted variables included assessment characteristics, aesthetic outcome domains, and patient-centered outcomes. Risk of bias was assessed using the Joanna Briggs Institute Critical Appraisal Checklist. Levels of evidence were classified according to the Oxford Centre for Evidence-Based Medicine. A total of 51 studies involving 7711 participants from 16 countries were included. Subjective tools were most frequently employed, led by the BREAST-Q (35/51, 69%), followed by expert- or panel-based evaluations (17/51, 33%) and the visual analog scale (2/51, 4%). Objective methods were applied in 19 studies and included 3-dimensional surface imaging (8/51, 16%), BCCT.core (7/51, 14%), eye tracking (3/51, 6%), and artificial intelligence-based analyses (3/51, 6%). Although subjective tools captured satisfaction with breast appearance, objective tools quantified morphological parameters and positional landmarks. BREAST-Q remains the cornerstone of outcome evaluation after breast reconstruction, providing patient-centered perspectives, including, but not limited to, aesthetic perception. A progressive shift toward multimodal evaluation was noticed, as no single modality comprehensively addressed all aesthetic domains. Future research should focus on integrating subjective and objective assessment methods within a unified framework. Level of Evidence: 3 (Therapeutic) For image description, please refer to the figure legend and surrounding text.

Humans

Acceptability of capillary point-of-care testing: a systematic review.

OBJECTIVE: To identify and synthesise evidence on the acceptability and perceived experience of finger-prick point-of-care testing (POCT) among patients and clinicians across healthcare settings. DESIGN: Systematic review conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA 2020) guidelines. DATA SOURCES: Medline, Embase, PsycInfo, CINAHL, Cochrane and Web of Science were searched from inception to January 2024 and re-run in July 2025, supplemented by citation tracking of relevant studies. ELIGIBILITY CRITERIA: Studies reporting patient and clinicians' experiences, perceptions, satisfaction or acceptability relating to finger-prick POCT for any health condition or blood parameter were eligible. Quantitative, qualitative and mixed-methods designs were included. DATA EXTRACTION AND SYNTHESIS: Data were extracted independently by two reviewers and synthesised using thematic analysis and narrative synthesis. Methodological quality was appraised using the Mixed-Methods Appraisal Tool. RESULTS: 21 studies met the inclusion criteria, encompassing 9128 participants (17 quantitative, 3 qualitative, 1 mixed methods). Across diverse clinical contexts, finger-prick POCT was reported as generally acceptable, less distressing and perceived as a convenient alternative to venous sampling in comparative studies. Thematic synthesis identified two major themes: (1) enhancing the patient-clinician relationship through improved engagement, communication and understanding of care and (2) clinical implications of finger-prick POCT on clinicians' workflow, confidence and skill acquisition. Finger-prick POCT was perceived to promote personalised consultations, enable immediate discussion of results and streamline decision-making. Clinicians highlighted its potential to expand task sharing, improve efficiency and strengthen continuity of care, although concerns regarding training, reliability and quality assurance were identified. CONCLUSIONS: Finger-prick POCT is generally acceptable to patients and clinicians, improving comfort, convenience, engagement and perceived efficiency. Implementation should prioritise training, infrastructure and quality assurance frameworks to maximise clinical and experiential benefits. PROSPERO REGISTRATION NUMBER: CRD42024512130.

Humans

Impact of adenosine in controlled aortic root reperfusion on clinical outcomes among patients undergoing valvular heart surgery.

BACKGROUND: Adenosine is a vital medication in cardiac surgery, particularly in valvular heart procedures. While its use has been linked to improved postoperative cardiac function in some studies, there remains significant uncertainty regarding the adenosine usage in aortic reperfusion phase. This lack of consensus poses challenges for surgeons, perfusionists, and anesthesiologists alike. This study aims to explore the impact of adenosine on clinical outcomes in patients undergoing valvular heart surgery. METHOD: This prospective randomized controlled trial was conducted over a three-month period. Sixty patients undergoing valvular heart surgery were enrolled using a continuous sampling method and randomly allocated into two equal groups of 30 patients each. The intervention group received adenosine-enriched aortic root reperfusion immediately prior to aortic declamping, while the control group underwent standard warm blood aortic root reperfusion. Both groups were matched for demographic and clinical characteristics to ensure comparability. RESULTS: Results indicated no significant differences in mean cardiopulmonary bypass (CPB) time, aortic cross-clamping duration, or mechanical ventilation between the intervention and control groups. However, the intervention group that received adenosine had a higher rate of antiarrhythmic agent usage in the operating room (P&#xa0;<&#xa0;0.05). Inotropic agent usage was similar in both groups during surgery and in the ICU. Additionally, laboratory parameters on the first day of ICU admission were comparable between groups. CONCLUSION: Results in the control group showed more favorable outcomes in terms of anti-arrhythmic drug usage, electroshock application, and arrhythmia prevalence. This study showed advantages for the standard warm blood aortic root reperfusion technique in managing post-operative cardiac rhythm disturbances, in comparison with the trial group.

Humans

Transcription regulation of cell fate plasticity - from embryonic development to tissue regeneration.

Cell fate plasticity refers to the capacity of cells sharing the same genome to alter, reverse, or reconfigure their identity under physiological, pathological, or experimental conditions. This property underlies embryonic development, cellular reprogramming, and tissue regeneration, but becomes progressively restricted as lineage identity is stabilized. Embryonic development represents an intrinsic process of fate transitions, whereas reprogramming and regeneration reveal how differentiated cells can dedifferentiate or transdifferentiate under specific conditions. Across these contexts, plasticity is governed by multilayered regulatory networks involving transcription factors, epigenetic regulators, cofactors, and the core transcription machinery. Robust regulatory programs stabilize cell identity, whereas stochastic fluctuations in gene expression and chromatin state can prime cells for fate transitions, adding a tunable dimension to plasticity control. In this review, we synthesize recent advances in the regulation of cell fate plasticity across development, reprogramming, and regeneration, highlighting how transcription factors, epigenetic modifications, transcriptional cofactors, and core transcription machinery cooperate to control cell fate decisions and plasticity.

Animals