Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diffusion theory”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

The role of polymer spacers in specific adhesion.

We study the role of flexible spacers in specific adhesion from the point of view of polymer reaction--diffusion theory. By assuming that the interactions between complementary adhesion moieties occur on a length scale much smaller than the size of the polymer spacer, we describe in detail binding and rupture between two opposing surfaces. Predictions are given for the physical properties of interest such as the time evolution of bond density and the ranges of attraction and unbinding. We also discuss the dynamic crossover between reversible and irreversible bridging.

Journal Article↗

Minimal principle for rotor filaments.

Three-dimensional rotors, or scroll waves, provide essential insight into the activity of excitable media. They also are a suspected cause in the formation and maintenance of ventricular fibrillation, whose lethality is well known. It is therefore of considerable interest to find out what configurations can be adopted by such pathologies. A scroll's behavior is embodied in its organizing center or filament, a largely quiescent tube about which the scroll rotates. Predicting filament shape has normally required computer-intensive simulations of the whole scroll in time. We have found a fast and robust principle that yields the prediction for stationary filaments on a purely geometrical basis, blind to the reaction parameters of the medium. The procedure is to calculate the filament shape as a minimal path. We work in singly diffusive media whose diffusivity tensor--and no other feature--varies spatially. Mathematical and numerical evidence is presented for the proposition that a stable filament is a geodesic in a three-dimensional space whose metric is given by the inverse diffusivity tensor of the medium. Away from the boundaries, a stable filament is unaffected by the reaction parameters. The algorithmic aspects of this work are subsidiary to our main purpose of drawing attention to the universal and unexpectedly exact fit of an elementary geodesic principle within reaction-diffusion theories.

Actin Cytoskeleton↗

Movement of ions through fixed pores in the neural membrane.

A simple configuration is first proposed for the pores used by sodium and potassium ions in moving through the neural membrane. The voltage dependence of the ion current through a system of such pores is then derived from diffusion theory and shown not to agree well with experimental observation. Good agreement is obtained, however, when the end segments of the pores are modified to include constrictions and ion-specific trapping centers.

Animals↗

Gravitational symmetry breaking in microtubular dissipative structures.

Reduction-diffusion theories can account for both morphogenesis and the sensitivity of biological systems to weak fields. They predict that gravity can cause the symmetry breaking that is necessary for pattern formation. Microtubules play an important role in organizing the cell, and recent studies hae shown that they can form in vitro dissipative structures. We have found that these structures show patterns of microtubular orientation that are gravity dependent and that the gravitational field causes symmetry breaking. This behavior, which cannot be explained by convection, is in accordance with the theory of dissipative structures. These results suggest that microtubular dissipative structures may play an important role both in morphogenesis and in accounting for the sensitivity of biological systems to weak fields. They aso provide another explanation for biological gravitropism.

Animals↗

Passive dosimetry using detector tubes.

Detector tubes for toluene were cut to produce a nominal 0.5 cm orifice above the indicator material, and exposed to known vapor concentrations. The time needed to reach a pre-determined stain length by simple diffusion was measured. Calibration charts were prepared for time versus concentration for a 1 mm stain, as well as for various stain lengths. Tests were performed to determine the effect of increasing the orifice length and of diffusion through the glass wool plug. Each of these parameters resulted in less reliable concentration measurements than tubes of relatively shorter orifice length having no glass wool plug. Diffusion theory was used to develop theoretical calibration charts for comparison with experimental results, with the former underestimating necessary for appearance of the experimentally observed stains. The use of detector tubes having an orifice length of 0.5 cm as passive dosimeters is shown to be highly feasible based on experimental results.

Equipment and Supplies↗

Development of local injectable dental gel: the influence of certain additives on physicochemical properties of glycerylmonooleate-based formulations.

The current research study is based on the design and development of a sol-gel biodegradable controlled-release formulation for use in the treatment of periodontal diseases. Glycerylmonooleate (GMO) was used as a main composition in the gel base. The influence of various additives, e.g., glycerylmonostearate (GMS), methylcellulose (MC), surfactants, and triglycerides, in GMO formulations on rheologic and swelling properties and release characteristics was described. It was demonstrated that the surfactants and triglycerides affected rheologic behavior, whereas GMS and MC influenced both rheologic and swelling properties of the bases. The release study revealed that drug released from the gel bases depended on the square root of time. The kinetics can be explained by the Higuchi's diffusion theory. Some polyols could enhance drug release from the gel. The stability results suggested that the dental gels obtained should be kept in the low temperature range.

Anti-Bacterial Agents↗

Effects of zinc on responses of skeletal muscle.

Zn(++) potentiates the twitch tension of the frog's sartorius muscle by as much as two to three times, and prolongs twitch time parameters. Tetanus tension is unchanged, but fusion frequency is reduced. Thus, the basic mechanical effect of Zn(++) is prolongation, but not intensification, of the active state. Threshold effects appear at about 0.005 mM Zn(++), and maximal changes at 0.05 mM. In 0.05 mM, potentiation begins after a delay of about 1 min. and develops with half-time of 6 min.; full changes reverse in pure Ringer's with halftime of 60 min. Diffusion theory analysis of these kinetics indicates that the potentiating action of zinc involves special features not found in potentiation by anions: a primary membrane action is not excluded, but Zn(++) may have to penetrate to and act at sarcoplasmic reticular or myoplasmic sites. Zn(++) does induce excitatory membrane effects: the fall of the action potential is slowed and the refractory period is increased about four times; but excitability as such is not changed. Unique chemical features of Zn(++) are discussed in relation to possible mechanisms of its action on muscle fibers.

Action Potentials↗

Turbulence measurement by the pulse luminescence method using a nitrogen pulse laser.

In order to visualize and measure with ease the velocity distribution and diffusion of turbulent flow, the pulse luminescence method was investigated. Turbulence intensity was obtained from the turbulent diffusion patterns by Taylor's diffusion theory. Apparatus was developed for easier measurement. A nitrogen pulse laser was used for instantaneous, high-power excitation. With the use of a night vision scope a bright image was recorded by a TV camera and video tape recorder. The optimum concentration of LC-G1A luminescent particles was about 0-05% wt for the measurement. High fidelity of the particles as an indicator of the fluid velocity was confirmed. It was demonstrated that the turbulence intensity could be visualized and measured quantitatively by the pulse luminescence method.

Lasers↗

Can photography be used to measure isodose distributions of space irradiance for laser photodynamic therapy?

The space irradiance isodose distribution of light delivered in tissue by an interstitial optical fibre may be determined by photographing the light diffusing out of the tissue. Provided that a plane of symmetry is photographed, it is shown that there is no significant distortion of the isodose distribution measured in this way. Two series of photographs were taken to test the method. In one set, a partially reflecting film was used to simulate the presence of the missing tissue. Isodose distributions obtained were in agreement with the predictions of diffusion theory. The isodoses were "scaled' by measuring the space irradiance at one point with a bulb-tipped optical fibre. Optical parameters are deduced from the measurements. The method, which is simple and fast in use, should be of wide applicability.

Humans↗

In vivo measurement of the optical interaction coefficients of human tumours at 630 nm.

The light distribution within a treatment volume is determined by the source geometry (e.g. superficial or interstitial illumination) and the optical interaction coefficients of the irradiated tissue. We have measured the energy fluence rate at various points within tumours undergoing irradiation with 630 nm light for photodynamic therapy for several source geometries. The relative positions of source and detector fibres were determined using CT scanning techniques. The results of the measurements were then applied to solutions of the diffusion theory which allowed the determination of the absorption coefficient (sigma a = 30.5 +/- 16 m-1), the reduced scattering coefficient (sigma' s = 941 +/- 735 m-1), the effective attenuation coefficient (sigma eff = 261 +/- 49 m-1) and the build-up coefficient which relates surface irradiance to the energy fluence rate at depth (k = 1.6 +/- 0.6). Knowledge of these coefficients allows the transmission of light through tissue to be predicted and hence the optical dosimetry of subsequent treatments to be planned more effectively.

Breast Neoplasms↗

A facility for biomedical experiments with thermal neutrons.

The Studsvik thermal-neutron facility was originally designed for neutron capture radiography (NCR) at high thermal-neutron fluence and low fast-neutron contamination. It has now been modified to permit irradiation of living cells and animals without the need for stopping and restarting the R2-0 reactor. Previous calculations of the thermal-neutron intensity at the NCR position were performed using the two-dimensional diffusion theory code DIXY. In this report the Monte Carlo program MCNP 3B is used to calculate the neutron fluence at the radiography position, and neutron and photon fluences at the positions of the cell specimens. The normalized neutron fluences from the calculations agree well with measured values and show that the contamination with high-energy neutrons is low. The agreement between measured and calculated photon doses was reasonable. The thermal-neutron fluence rate is (2.3 +/- 0.1) x 10(9) cm-2 s-1 at 100 kW at the NCR position and (0.96 +/- 0.03 x 10(9) cm-2 s-1 at 100 kW at the front plate of the loading tube. The photon dose is about (1.6 +/- 0.2) x 10(-12) Gy per neutron. Survival curves of V79 cells grown as monolayers and irradiated in the thermal neutron beam, with and without boron, are presented.

Animals↗

A mathematical model for light dosimetry in photodynamic destruction of human endometrium.

We are involved in the development of photodynamic therapy (PDT) as a minimally invasive method for treating dysfunctional uterine bleeding, one of the primary clinical indications for hysterectomy. In this paper, we analyse light propagation through the uterus in order to specify the requirements for a light delivery system capable of effectively performing endometrial PDT. Our approach involves developing an analytical model based on diffusion theory to predict optical fluence rate distributions when cylindrical and spherical optical applicators are placed in the uterine cavity. We apply the results of our model calculations to estimate the thermal effects of optical irradiation and the effective photodynamic optical dose. Theoretical fluence rate calculations are compared to fluence rate measurements made in fresh, surgically removed human uteri. Our results show that a trifurcated cylindrical optical applicator inserted into the human uterus can provide a light dose that is sufficient to cause photodynamic destruction of the entire endometrium. When the optical power per unit length of each cylindrical applicator is 100 mW cm-1 (at 630 nm), a fluence rate of 40 mW cm-2 is delivered to the boundary layer between the endometrium and the myometrium (a depth of about 4-6 mm). The optical fluence delivered to the boundary layer after 20 min of exposure is 50 J cm-2, a level that is generally accepted to cause tissue damage throughout the endometrium in most patients.

Dose-Response Relationship, Radiation↗

Light dosimetry in vivo.

This paper starts with definitions of radiance, fluence (rate) and other quantities that are important with regard to in vivo light dosimetry. The light distribution in mammalian tissues can be estimated from model calculations using measured optical properties or from direct measurements of fluence rate using a suitable detector. A historical introduction is therefore followed by a brief discussion of tissue optical properties and of calculations using diffusion theory, the P3-approximation or Monte Carlo simulations. In particular the form of the scattering function is considered in relation to the fluence rate close to the tissue boundary, where light is incident. Non-invasive measurements of optical properties yield the absorption coefficient mu a and mu s(1 - g), where mu s is the scattering coefficient and g is the mean cosine of the scattering angle. An important question is whether this combination is sufficient, or whether g itself must be known. It appears that for strongly forward scattering, as in mammalian tissues, rather detailed knowledge of the scattering function is needed to reliably calculate the fluence rate close to the surface. Deeper in the tissue mu s (1 - g) is sufficient. The construction, calibration and use of fibre-optic probes for measurements of fluence rate in tissues or optical phantoms is discussed. At present, minimally invasive absolute fluence (rate) measurements seem to be possible with an accuracy of 10-20%. Examples are given of in vivo measurements in animal experiments and in humans during clinical treatments. Measurements in mammalian tissues, plant leaves and marine sediments are compared and similarities and differences pointed out. Most in vivo light fluence rate measurements have been concerned with photodynamic therapy (PDT): Optical properties of the same normal tissue may differ between patients. Tumours of the same histological type may even show different optical properties in a single patient. Treatment-induced changes of optical properties may also occur. Scattered light appears to contribute substantially to the light dose. All these phenomena emphasize the importance of in situ light measurements. Another important dosimetric parameter in PDT is the concentration and distribution of the photosensitizer. Apart from in vivo fluorescence monitoring, the photosensitizer part of in vivo PDT dosimetry is still in its infancy.

Animals↗

Radiance modelling using the P3 approximation.

Light dosimetry is an essential component of effective photodynamic therapy (PDT) of tumours. Present PDT light dosimetry techniques rely on fluence-based models and measurements. However, in a previous paper by Barajas et al, radiance-based light dosimetry was explored as an alternative approach. Although successful in demonstrating the use of Monte Carlo (MC) simulations of radiance in tissue optical characterization, the MC proved time consuming and impractical for clinical applications. It was proposed that an analytical solution to the transport equation for radiance would be desirable as this would facilitate and increase the speed of tissue characterization. It has been found that the P3 approximation is one such potential solution. Radiance and fluence expressions based on the P3 approximation were used to optically characterize an Intralipid-based tissue phantom of varying concentration of scatterer (Intralipid) and absorber (methylene blue) using a plane wave illuminated, semi-infinite medium geometry. The results obtained compare favourably with the Grosjean approximation of fluence (a modified diffusion theory) using the same optical parameters (mu(a), mu(s), g). The results illustrate that radiance-based light dosimetry is a viable alternative approach to tissue characterization and dosimetry. It is potentially useful for clinical applications because of the limited number of invasive measurements needed and the speed at which the tissue can be characterized.

Data Interpretation, Statistical↗

Laser thermal therapy: utility of interstitial fluence monitoring for locating optical sensors.

Multipoint optical fluence measurements can potentially be used to detect coagulation-induced changes in optical propagation during interstitial laser thermal therapy. Estimating the dimensions of coagulation using on-line optical monitoring, which is applicable to treatments where the tip of the source fibre is not precharred, may be limited by the accuracy of the placement of optical sensors with respect to source fibres. A strategy has been developed to determine accurately the position of a four-sensor linear array, prior to treatment, using optical fluence data obtained from the sensors for low-power (< or = 0.5 W) irradiation. A minimum of four sensors in an array was required in order to develop a mathematical formulation for position determination that did not require tissue optical properties or laser power as input. Optical propagation was based on diffusion theory for homogeneous tissues in spherical geometry. Low input laser power is needed to ensure that there are no thermally induced changes in tissue optical properties not accounted for in the mathematical description. Experimental evaluation was performed in a tissue-equivalent liquid phantom using 0.5 W of 805 nm optical energy and a translatable isotropic optical sensor. For sensor locations with 2 mm spacing, placement accuracy of 0.67 mm was achieved. The accuracy improved to 0.13 mm as the sensor spacing increased to 5 mm.

Hot Temperature↗

Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy.

A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO2) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO2 was 73.0 +/- 0.9 and 70.5 +/- 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO2 decreased (69.1 +/- 1.8 and 63.8 +/- 2.1% in MG and LG, respectively; P < 0.01). The LG desaturation was greater than the MG desaturation (P < 0.02). These results strengthen the role of time-resolved near-infrared spectroscopy as a powerful tool for investigating the spatial and temporal features of muscle SmO2 and tHb.

Adipose Tissue↗

Characterization of normal breast tissue heterogeneity using time-resolved near-infrared spectroscopy.

In recent years, extensive efforts have been made in developing near-infrared optical techniques to be used in detection and diagnosis of breast cancer. Variations in optical properties of normal breast tissue set limits to the performance of such techniques and must therefore be thoroughly examined. In this paper, we present intra- and intersubject as well as contralateral variations of optical and physiological properties in breast tissue as measured by using four-wavelength time-resolved spectroscopy (at 660, 786, 916 and 974 nm). In total, 36 volunteers were examined at five regions at each breast. Optical properties (absorption, mu(a), and reduced scattering, mu'(s)) are derived by employing diffusion theory. The use of four wavelengths enables determination of main tissue chromophores (haemoglobin, water and lipids) as well as haemoglobin oxygenation. Variations in all evaluated properties seen over the entire breast are approximately twice those for small-scale heterogeneity (millimetre scale). Intrasubject variations in optical properties are almost in all cases below 20% for mu'(s), and 40% for mu(a). Overall variations in water, lipid and haemoglobin concentrations are all in the order of 20%. Oxygenation is the least variable of the quantities evaluated, overall intrasubject variations being 6% on average. Extracted physiological properties confirm differences between pre- and post-menopausal breast tissue. Results do not indicate systematic differences between left and right breasts.

Adult↗

Simulation of voltage-sensitive optical signals in three-dimensional slabs of cardiac tissue: application to transillumination and coaxial imaging methods.

Voltage-sensitive dyes are an important tool in visualizing electrical activity in cardiac tissue. Until today, they have mainly been applied in cardiac electrophysiology to subsurface imaging. In the present study, we assess different imaging methods used in optical tomography with respect to their effectiveness in visualizing 3D cardiac activity. To achieve this goal, we simulate optical signals produced by excitation fronts initiated at different depths inside the myocardial wall and compare their properties for various imaging modes. Specifically, we consider scanning and broad-field illumination, including trans- and epi-illumination. We focus on the lateral optical resolution and signal intensity, as a function of the source depth. Optical diffusion theory is applied to derive a computationally efficient approximation of the point-spread function and to predict voltage-sensitive signals. Computations were performed both for fluorescent and absorptive voltage-sensitive dyes. Among all the above-mentioned methods, fluorescent coaxial scanning yields the best resolution (<2.5 mm) and gives the most information about the intramural cardiac activity.

Action Potentials↗