Radiance modelling using the P3 approximation.

Abstract

Light dosimetry is an essential component of effective photodynamic therapy (PDT) of tumours. Present PDT light dosimetry techniques rely on fluence-based models and measurements. However, in a previous paper by Barajas et al, radiance-based light dosimetry was explored as an alternative approach. Although successful in demonstrating the use of Monte Carlo (MC) simulations of radiance in tissue optical characterization, the MC proved time consuming and impractical for clinical applications. It was proposed that an analytical solution to the transport equation for radiance would be desirable as this would facilitate and increase the speed of tissue characterization. It has been found that the P3 approximation is one such potential solution. Radiance and fluence expressions based on the P3 approximation were used to optically characterize an Intralipid-based tissue phantom of varying concentration of scatterer (Intralipid) and absorber (methylene blue) using a plane wave illuminated, semi-infinite medium geometry. The results obtained compare favourably with the Grosjean approximation of fluence (a modified diffusion theory) using the same optical parameters (mu(a), mu(s), g). The results illustrate that radiance-based light dosimetry is a viable alternative approach to tissue characterization and dosimetry. It is potentially useful for clinical applications because of the limited number of invasive measurements needed and the speed at which the tissue can be characterized.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Dickey, O Barajas, K Brown, J Tulip, R B Moore. 1998. Radiance modelling using the P3 approximation.. https://doi.org/10.1088/0031-9155%2F43%2F12%2F013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characterization of obstructive nonapneic respiratory events in moderate sleep apnea syndrome.

Obstructive nonapneic respiratory events (ONAREs, i.e., obstructive hypopneas [OHs] and respiratory effort related arousals [RERAs]) are clinically important as producing sleep fragmentation but are much more difficult to detect and classify than obstructive apneas. We characterized 1,061 ONAREs in 15 unselected patients with moderate sleep apnea-hypopnea syndrome (OSAHS) according to the 1999 American Academy of Sleep Medicine (AASM) Task Force recommendations concerning accurate skills for respiratory measurements (i.e., pneumotachograph and esophageal pressure [Pes]) and definitions of respiratory events. OHs were defined as > or = 50% decrease in flow or < 50% but > or = 30% decrease in flow associated with either a desaturation of > or = 3% or a cortical arousal. RERAs corresponded to a less than 30% decrease in flow associated with an arousal. OHs represented a large majority of the events (79.9%, n = 848). Among the events demonstrating a 30 to 50% reduction in flow (n = 392), the occurrence of a cortical arousal permitted the classification of 246 events as OHs (62.8%). RERAs represented only 5.3% of the events. Finally 14.8% of the events were classified as indeterminate owing to a < 50% and > or = 30% airflow decrease without arousal or desaturation or an airflow decrease less than 30% without arousal. The same level of DeltaPes was observed at the end of OHs and RERAs (21.9 +/- 5.5 versus 18.9 +/- 5.7 cm H(2)O respectively [NS]) whereas the reduction in flow was as expected, higher for OH (57.9 +/- 10.7 versus 21.3 +/- 4.9%). In a population of moderate OSAHS, OH represented the dominant type of ONAREs when RERAs should be considered as specific but relatively rare respiratory events. The occurrence and the recognition of a microarousal represented the key associated factor for classifying respiratory events as hypopneas. The high rate (15%) of unclassified events demonstrated some limitations in the AASM Task Force recommendations for definitions of respiratory events. Similar levels of DeltaPes found at the end of RERAs and OHs, although the reduction in flow was higher for OHs, suggest that different levels of collapsibility can exist throughout the night in a given patient.

Data Interpretation, Statistical↗