Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Storage Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Dermatoscopy of "dysplastic nevi": a beacon in diagnostic darkness.

The sequential progression model for melanocytic tumours from common nevus to malignant melanoma was proposed by Clark almost 30 years ago. The "dysplastic nevus" has frequently been considered a logical offspring of this concept and as a direct precursor of melanoma, analogous to the epithelial dysplasia-carcinoma sequence. Despite the use of modern molecular methods, there is no consensus as to if the dysplastic nevus represents a true precursor lesion of melanoma, a separate distinct type of nevus, or a diagnostic dilemma. Currently, the concept of melanocytic dysplasia remains subject to confusing definitions at all levels of the diagnostic process, i.e. clinical appearance, dermatohistopathology, and molecular biology. In this review, we collect evidence that nevi fulfilling Clark and Elder's classic histological criteria mostly represent "endpoints" of nevocytic evolution, whereas a minority of "dysplastic nevi" represent true melanoma precursors. The unsolved dilemma is that neither clinical, histopathological nor molecular criteria exist to make a distinction between dysplastic nevi and early melanomas. Our analysis of the current knowledge on dysplastic nevi shows that dermatoscopy remains the only quantifiable, easily applicable and reproducible diagnostic tool to approach the problem. Due to a "quantum leap" in optical resolution, objective scores can be established, e.g. the total dermatoscopy score (TDS) according to the ABCD rule, and documentation of changes over time are possible by digital image storage devices. Although dermatoscopy does not solve the dilemma of discriminating early, basically feature-less melanomas from dysplastic nevi, and it does not prove that dysplastic nevus is a distinct entity, it helps make melanocytic tumours with unclear malignant potential a manageable disease.

Dermatology↗

Surface plasmon subwavelength optics.

Surface plasmons are waves that propagate along the surface of a conductor. By altering the structure of a metal's surface, the properties of surface plasmons--in particular their interaction with light--can be tailored, which offers the potential for developing new types of photonic device. This could lead to miniaturized photonic circuits with length scales that are much smaller than those currently achieved. Surface plasmons are being explored for their potential in subwavelength optics, data storage, light generation, microscopy and bio-photonics.

Journal Article↗

An investigation of the photoinduced changes of absorption of high-performance photoaddressable polymers.

Recently, a novel class of photoaddressable polymers (PAPs) has been reported, which allows for reversible photorecording with values of the photoinduced birefringence in excess of 0.2. These polymers are copolymers of methacrylate-type monomers with a mesogenic and a nonmesogEnic photoactive azobenzene in the side chain. This report presents a detailed analysis of the three-dimensional photoinduced reorientation of side chains within thin layers of PAP materials, utilizing polarized UV/Visible spectroscopy, infrared, and photothermal deflection spectroscopy (PDS). The three-dimensional orientation distribution before and after illumination with 514 nm polarized light was investigated by angle-dependent UV/Vis absorption spectroscopy. As-prepared samples possess an uniaxial orientation with the photoactive units being preferentially aligned within the plane of the substrate layer. These films become biaxial upon photoalignment with polarized light incident normal to the substrate plane. For PAP materials containing mesogenic side chains, the out-of-plane absorption stays nearly unchanged, proving that the photoinduced reorientation occurs mainly within the layer plane. For a homopolymer bearing only a nonmesogenic azobenzene in the side chain, photobleaching is observed, associated with a disease in absorption in all three principle directions. This finding can be understood in terms of an orientational coupling between the photodegradation product and the active azobenzene units. Photodegradation was well established by infrared spectroscopy. Photothermal deflection spectroscopy has been performed to manifest photoinduced changes in the transparent wavelength region of the PAP material, below the absorption edge. In contrast to the pronounced optical changes in the UV/Vis and IR spectra, the absorption in this range remains nearly unchanged. This result provides evidence that the polymers can be well applied for holographic storage in thick-layer devices.

Journal Article↗

Displaying radiologic images on personal computers: image storage and compression: Part 1.

This is the third article of our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers. Part 1 of this article discusses image storage and reviews the basic concepts of information theory and image compression; part 2 will discuss specific methods of image compression. There are a wide variety of removable storage devices available to users who need to archive radiologic images on their personal computers. Tape drives have potentially very large storage capacity but slow performance. Removable SyQuest (SyQuest Technology, Femont, CA) and Bernoulli disks have near hard disk performance and can store from 100 to 150 Mbytes. Magneto-optical drives can store nearly 1 Gb on a 5.25" disk, with somewhat slower performance. Selecting the most appropriate storage solution requires a careful balance of the user's requirements, including performance, storage needs, cost and compatibility with other users. Despite the advances in low cost high capacity storage technology, image compression remains a crucial technology for modern diagnostic radiology because digital images require such large amounts of storage. Image compression is possible because radiologic images have relatively low entropy (high information content) compared with random noise. Image compression is classified as lossless (nondestructive) or lossy (destructive). Lossless image compression commonly achieve compression ratios of 1.5:1 to 3:1 (33% to 67%), whereas lossy compression can compresses images from 3:1 to 30:1 (67% to 97%).(ABSTRACT TRUNCATED AT 250 WORDS)

Computer Storage Devices↗

On-line and in-situ detection of polycyclic aromatic hydrocarbons (PAH) on aerosols via thermodesorption and laser-induced fluorescence spectroscopy.

A fiber optical sensor system for the determination of polycyclic aromatic hydrocarbons (PAH) on aerosols by laser-induced, time-resolved fluorescence is combined with a thermodesorption device. The sensor system is based on an aerosol flow cell, which is fibre-optically coupled to a pulsed nitrogen laser for excitation and the detection system. Time-resolved fluorescence emission spectra are detected by a monochromator equipped with a photomultiplier and a fast digital storage oscilloscope. The analytical figures of merit of the thermodenuder are reported for benzo[a]pyrene, benzo[b]fluoranthene, and benzo[ghi]-perylene on ultrafine soot and NaCl aerosols. By thermodesorption of the PAH, problems due to quenching of the PAH fluorescence by the bulk aerosol material or excimer formation on the aerosol surface were avoided. For the PAH under study, the sensitivity was improved considerably and detection limits between 110 and 850 ng m(-3) were attained, while a response time of 2-3 min was achieved with the thermodenuder. A calibration for PAH on ultrafine soot and NaCl aerosols was established independent of the aerosol substrate.

Aerosols↗

The zeta potential of cyclo-olefin polymer microchannels and its effects on insulative (electrodeless) dielectrophoresis particle trapping devices.

While cyclo-olefin polymer microchannels have the potential to improve both the optical detection sensitivity and the chemical resistance of polymer microanalytical systems, their surface properties are to date not thoroughly characterized. These surface properties dictate, among other things, electrokinetic effects when electric fields are present. Here, we report the measurement of the zeta potential of cyclo-olefin polymers (injection-molded and hot-embossed Zeonor 1060R and 1020R) microchannels as a function of pH, counter-ion concentration, storage conditions, and chemical treatment in aqueous solutions both with and without EOF-suppressing additives. In contrast with previous reports, significant surface charge is measured, consistent with titration of charged sites with pK(a) = 4.8. Storage in air, acetonitrile, or aqueous solutions has relatively minor effects. While the source of the surface charge is unclear, chemical functionalization has shown that carboxylic acid groups are not present at the surface, consistent with the chemical structure of Zeonor. EOF-suppressing additives (hydroxypropylmethylcellulose) and conditioning in perchloric acid allow the surface charge to be suppressed. We demonstrate dielectrophoretic particle trapping devices in Zeonor 1060R substrates that show reduced trapping voltage thresholds as compared to previous implementations in glass.

Cycloparaffins↗

A novel device for the non-invasive measurement of free hemoglobin in blood bags.

The production of red blood cell concentrates from human donors is a very expensive procedure and human resources are in short supply. Under perfect storage conditions at a temperature of 2-6 degrees C, a blood bag must be used within 35-49 days (in Germany). Visual inspection of the bag for apparent hemolysis by a blood bank physician is a crucial but subjective quality control assessment. Since an interruption of the cold chain cannot be definitely ruled out, bags are often disposed of prematurely for safety reasons. There is currently no method of testing a closed blood bag with respect to hemolysis for its suitability to be used in a transfusion. The proposed optical measuring device is a hemoglobin sensor which determines the free hemoglobin in standard erythrocyte concentrates without opening the bag. The optical measurements are done on the flexible tube connected to the main bag. The optical measurements were evaluated using standard hemoglobin solutions with an accuracy of 0.005 g/dL. These investigations show that in the future each blood bag can be tested non-invasively for its content of free hemoglobin. This will contribute to decreasing the wastage rate of red blood cell concentrates.

Blood Chemical Analysis↗

Material properties of the human lumbar facet joint capsule.

The human facet joint capsule is one of the structures in the lumbar spine that constrains motions of vertebrae during global spine loading (e.g., physiological flexion). Computational models of the spine have not been able to include accurate nonlinear and viscoelastic material properties, as they have not previously been measured. Capsules were tested using a uniaxial ramp-hold protocol or a haversine displacement protocol using a commercially available materials testing device. Plane strain was measured optically. Capsules were tested both parallel and perpendicular to the dominant orientation of the collagen fibers in the capsules. Viscoelastic material properties were determined. Parallel to the dominant orientation of the collagen fibers, the complex modulus of elasticity was E*=1.63MPa, with a storage modulus of E'=1.25MPa and a loss modulus of: E" =0.39MPa. The mean stress relaxation rates for static and dynamic loading were best fit with first-order polynomials: B(epsilon) = 0.1110epsilon-0.0733 and B(epsilon)= -0.1249epsilon + 0.0190, respectively. Perpendicular to the collagen fiber orientation, the viscous and elastic secant moduli were 1.81 and 1.00 MPa, respectively. The mean stress relaxation rate for static loading was best fit with a first-order polynomial: B (epsilon) = -0.04epsilon - 0.06. Capsule strength parallel and perpendicular to collagen fiber orientation was 1.90 and 0.95 MPa, respectively, and extensibility was 0.65 and 0.60, respectively. Poisson's ratio parallel and perpendicular to fiber orientation was 0.299 and 0.488, respectively. The elasticity moduli were nonlinear and anisotropic, and capsule strength was larger aligned parallel to the collagen fibers. The phase lag between stress and strain increased with haversine frequency, but the storage modulus remained large relative to the complex modulus. The stress relaxation rate was strain dependent parallel to the collagen fibers, but was strain independent perpendicularly.

Adult↗

Solid-state optical scanning system for remote measurements in biomechanical systems.

A remote optical sensing system, employing a self-scanning photodiode array, is described, and its operation is demonstrated for measurements of rapid dimensional changes in contracting smooth muscle preparations. The single-line sensor array, a commercially available charge-coupled device integrated circuit, with 256 elements at 25-microns intervals, is mounted in the image plane of an optical system focused on a backlit test object. The amplitude profile of each scan is proportional to the illumination reaching the individual sensory elements. Auxilliary circuitry generates a raster of successive scan lines on the face of a storage oscilloscope. Spatial and temporal information about the target and its motions may be derived from the displayed raster scan. Performance is illustrated using an artificial target and a muscle fiber bearing opaque markers. Successive lines may be scanned in as briefly as 5 ms (at 10-ms intervals) or in as long as 50 ms (at 1-s intervals). Each raster may contain up to 256 lines, although not all of the lines need to be displayed. The spatial resolution is determined by the photodiode spacing in the sensory array and by the magnitude of the optical system in use; as described here, the resolution is on the order of 0.2 mm for a 20-mm scan length.

Animals↗

Simultaneous digitization of upper airway fiber-optic images and respiratory signals.

We developed an inexpensive and efficient method for simultaneously digitizing respiratory signals and fiber-optic images of the upper airway. The main components of the system are a fiber-optic scope, a charge coupled device video camera, and a personal computer equipped with a frame grabber and an A/D board. The frame grabber digitizes images at five frames per second while the A/D board samples six respiratory signals at 25 samples per second. Digitized images are saved only in the event that the user instructs the computer to do so in order to limit disk space requirements. A circular buffering technique provides continuous storage of the most recent 50 frames in frame grabber memory. This feature gives the user up to 10 seconds, following the beginning of a respiratory event, to initiate the saving of images to computer hard disk. A postacquisition program displays the data acquired during the sleep study and allows the user to interactively select images for subsequent upper airway area measurement. This system enables us to observe and quantify the dynamics of the upper airway during different breathing conditions with minimal time and cost. It is also a potential clinical tool to use to determine the site of obstruction during sleep in patients with obstructive sleep apnea.

Computers↗

A microbead array chemical sensor using capillary-based sample introduction: toward the development of an "electronic tongue".

The development of a micromachined fluidic structure for the introduction of liquid samples into a chip-based sensor array composed of individually addressable polymeric microbeads is presented. The micromachined structure consists of micromachined storage cavities combined with a covering glass layer that confines the microbeads and fluidic channels. In our sensor array transduction occurs via optical (colorimetric and fluorescence) changes to receptors and indicator molecules that are covalently attached to termination sites on the polymeric microbeads. Spectral data are acquired for each of the individual microbeads using a charged-coupled device (CCD) allowing for the near-real-time analysis of liquid sample. Hence the micromachined fluidic structure must allow for both optical access to the microbeads and fluid flow through the micromachined cavities that serve as the microreactors/analysis chambers. One of the key parts of the structure is a passive fluid introduction system driven only by capillary force. This simple means of fluid introduction realizes a compact device. The capillary flow on the inlet channel has been studied, and the responses of the microbeads (alizarin complexone) to a liquid sample have been characterized. The test results show that this system is useful in a micro-total-analysis-system (mu-TAS) and biomedical applications.

Biomimetics↗

Anisotropic spinodal dewetting as a route to self-assembly of patterned surfaces

The ability to pattern surfaces on a microscopic length scale is of importance for technological applications such as the fabrication of microelectronic circuits and digital storage media. Devices fabricated entirely from polymers are now available, opening up the possibility of adapting polymer processing technologies to fabricate cheap, large-area devices using non-lithographic techniques--for example, by exploiting dewetting and phase separation in thin films. But the final pattern adopted by the polymer film using such approaches requires a template printed onto the substrate by optical lithography, microcontact printing or vapour deposition. Here we describe a simple process for patterning surfaces that does not require a template. Our method involves the spinodal dewetting of a polymer surface by a thin polymer film, in which a liquid film breaks up owing to the amplification of thermal fluctuations in film thickness induced by dispersion forces. A preferred orientation is imposed on the dewetting process simply by rubbing the substrate, and this gives rise to patterns of remarkably well-aligned polymer lines. The width of these lines is well-defined, and is controlled by the magnitude of the dispersion forces at the interface, which in turn can be varied by varying the thickness of the polymer substrate. We expect that further work will make it possible to optimize the degree of order in the final morphology.

Journal Article↗

Development of an integrated filing system for endoscopic images.

A new integrated filing system for endoscopic images has been developed, comprising a main image filing system and subsystems located at different stations. A hybrid filing system made up of both digital and analog filing devices was introduced to construct this system that combines the merits of the two filing methods. Each subsystem provided with a video processor, is equipped with a digital filing device, and routine images were recorded in the analog image filing device of the main system. The use of a multi-input adapter enabled simultaneous input of analog images from up to 8 video processors. Recorded magneto-optical disks make it possible to recall the digital images at any station in the hospital; the disks are copied without image degradation and also utilised for image processing. This system promises reliable storage and integrated, efficient management of endoscopic information. It also costs less to install than the so-called PACS (picture archiving and communication system), which connects all the stations of the hospital using optical fiber cables.

Analog-Digital Conversion↗

Two-dimensional, computer-controlled film scanner: quantitation of fluorescence from ethidium bromide-stained DNA gels.

A two-dimensional scanner based on a digital plotter is described. The device is used to analyze photographic negatives of ethidium bromide-stained DNA-agarose gels. Scanning is controlled by and photometric data transferred to a computer for processing, storage, display, and analysis such as integration of the areas under bands and determination of the mean distances of migration of polydisperse samples. An integral light source and detector module designed for reading optical "bar-codes" is mounted in place of the pen of the plotter. Spatial resolution and reproducibility are about 0.2 and 0.005 mm, respectively. Photometric precision as good as one part per thousand is achieved by sinusoidal modulation of the intensity of the light source and synchronous, phase-sensitive detection of the signal from the detector by a lock-in amplifier. No part of the sensor assembly touches the surface of the negative. In contrast to a densitometer, the computer transforms photometric data to values directly proportional to the amount of DNA at given points on the original gel. The ability to move the sensor in two dimensions over the negative allows for the integration across the width of a lane correctly allowing for the nonuniform distribution of the DNA.

Computers↗

Image identification system based on an optical broadcast neural network processor.

We describe the implementation of a vision system based on a hardware neural processor. The architecture of the neural network processor has been designed to exploit the computational characteristics of electronics and the communication characteristics of optics in an optimal manner, thus it is based on an optical broadcast of input signals to a dense array of processing elements. The vision system has been built by use of a prototype implementation of a neural network processor with discrete optic and optoelectronic devices. It has been adapted to work as a Hamming classifier of the images taken with a 128 x 128 complementary metal-oxide semiconductor image sensor. Its results, performance characteristics of the image classification system, and an analysis of its scalability in size and speed, with the improvement of the optoelectronic neural processor, are presented.

Algorithms↗

Confocal fluorescence microscopy and three-dimensional reconstruction.

Several recent technological advances have considerably improved the field of confocal fluorescence microscopy. Improvements in confocal microscope design, new fluorescent probes and indicators, more sensitive imaging devices, and computer advances which allow for data manipulation and storage provide a convenient method to acquire complex three-dimensional (3-D) architectural details which previously were difficult or impossible to obtain from biological specimens. Applications of the laser scanning and tandem scanning confocal microscopes offer the potential for gaining powerful insights into the complex relationship of cellular structure and function. Confocal microscopy generates optical sections free from out-of-focus blur. With the development of new visualization tools to render and display complex 3-D data, a set of optical sections taken at different focal planes can be three-dimensionally reconstructed to create an animated sequence which can reveal latent features of the specimen. The combination of confocal microscopy and 3-D reconstruction provides a powerful new imaging tool to advance knowledge about structural and functional cellular properties as they occur dynamically in three dimensions.

Animals↗

Adaptive silicon monochromators for high-power wigglers; design, finite-element analysis and laboratory tests.

Multipole wigglers in storage rings already produce X-ray power in the range up to a few kilowatts and planned devices at third-generation facilities promise up to 30 kW. Although the power density at the monochromator position is an order of magnitude lower than that from undulators, the thermal strain field in the beam footprint can still cause severe loss of performance in X-ray optical systems. For an optimized adaptive design, the results of finite-element analysis are compared with double-crystal rocking curves obtained with a laboratory X-ray source and, in a second paper [Quintana, Hart, Bilderback, Henderson, Richter, Setterson, White, Hausermann, Krumrey & Schulte-Schrepping (1995). J. Synchotron Rad. 2, 1-5], successful tests at wiggler sources at CHESS and ESRF and in an undulator source at HASYLAB are reported.

Journal Article↗

Manufacture of epikeratophakia lens.

Epikeratophakia lenses may be manufactured from donor cornea either with a lathe or using devices that make flat cuts on to previously deformed cornea. Details are given of a manufacturing technique using a cryolathe, including the storage and preparation of donor corneas and derivation of the formulae used to determine the radius of lathe cut.

Aphakia↗