Search PubMed⌕ Search

PubMed · 16023957

A microbead array chemical sensor using capillary-based sample introduction: toward the development of an "electronic tongue".

Abstract

The development of a micromachined fluidic structure for the introduction of liquid samples into a chip-based sensor array composed of individually addressable polymeric microbeads is presented. The micromachined structure consists of micromachined storage cavities combined with a covering glass layer that confines the microbeads and fluidic channels. In our sensor array transduction occurs via optical (colorimetric and fluorescence) changes to receptors and indicator molecules that are covalently attached to termination sites on the polymeric microbeads. Spectral data are acquired for each of the individual microbeads using a charged-coupled device (CCD) allowing for the near-real-time analysis of liquid sample. Hence the micromachined fluidic structure must allow for both optical access to the microbeads and fluid flow through the micromachined cavities that serve as the microreactors/analysis chambers. One of the key parts of the structure is a passive fluid introduction system driven only by capillary force. This simple means of fluid introduction realizes a compact device. The capillary flow on the inlet channel has been studied, and the responses of the microbeads (alizarin complexone) to a liquid sample have been characterized. The test results show that this system is useful in a micro-total-analysis-system (mu-TAS) and biomedical applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Young-Soo Sohn, Adrian Goodey, Eric V Anslyn, John T McDevitt, Jason B Shear, Dean P Neikirk. 2004-12-02. A microbead array chemical sensor using capillary-based sample introduction: toward the development of an "electronic tongue".. https://doi.org/10.1016/j.bios.2004.08.050

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Polymeric, electrically tunable diffraction grating based on artificial muscles.

We demonstrate a low-cost, electrically tunable diffraction grating that is driven by a dielectric elastomer actuator. The angular tuning range of the polymer-based device is up to 118 mrad for the first diffracted order. The achievable grating period change of 32% is an improvement by more than a factor of 150 compared with existing analog tunable diffraction gratings based on hard materials. We show that in combination with a white light source, the presented diffraction grating can be used as a wavelength-adjustable luminous source. Such an illuminant has a potential application in inexpensive color displays that could reproduce all perceivable colors.

Biomimetics↗

Design, synthesis and evaluation of peptidomimetics based on substituted bicyclic 2-pyridones-targeting virulence of uropathogenic E. coli.

Substituted bicyclic 2-pyridones, termed pilicides, are dipeptide mimetics that prevent pilus assembly in uropathogenic Escherichia coli. Here, we apply rational design to produce four classes of extended peptidomimetics based on two bioactive 2-pyridones. The key intermediate in the synthesis was an amino-functionalised 2-pyridone scaffold, which could be obtained via a mild and selective nitration and subsequent reduction. Procedures were then developed to further derivatize this amino-substituted core and a total of 24 extended peptidomimetics were synthesised and evaluated for chaperone affinity and in vivo antivirulence activity in P pili producing E. coli. Enhanced affinities for the target protein were observed within the generated set of compounds, while the ability to prevent pilus assembly in vivo was significantly decreased compared to the parent lead compounds. The results suggest that the limited in vivo potencies of the analogues are either uptake/distribution related or due to loss in binding specificity.

Biomimetics↗