Search PubMedSearch

SEARCH · Search PubMed

Results for “Mixed methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,827 records · Page 13Linked to original sources

Insulin, Semaglutide and Dapagliflozin in Adults With Type 1 Diabetes: Design and Methods of Triple Therapy for Type 1 Diabetes (TTT1)-An International Phase 3 Clinical Trial.

AIMS: Attaining target glycaemia can be a challenge in Type 1 Diabetes (T1D) due to insulin-induced weight gain. Adjunct therapy with modern glucose-lowering agents developed for type 2 diabetes (T2D) has great potential but may be insufficiently efficacious and carries risks of hypoglycaemia and ketosis. We designed the first Phase 3 clinical trial to assess the efficacy and safety of adding a Glucagon-Like Peptide 1 receptor agonist (GLP-1RA) and a Sodium-Glucose Co-transporter (SGLT2) Inhibitor to insulin therapy in overweight and obese adults with T1D and glycaemia above target (HbA1c 7.5%-11.0% inclusive) (NCT03899402). MATERIALS AND METHODS: In Period 1, participants are randomized 2:1 (open label) for 26 weeks to semaglutide and insulin (uptitrated to 1.0 mg weekly) or standard insulin therapy. In Period 2, those randomized to semaglutide and insulin in Period 1 are further randomized (double-blind) for 26 weeks to dapagliflozin (10 mg daily) or placebo, in addition to semaglutide. The primary objective is to compare change in HbA1c on 'triple therapy' (dapagliflozin, semaglutide and insulin) with 'dual therapy' (placebo, semaglutide and insulin). Secondary objectives include comparisons of triple therapy with standard insulin therapy and dual therapy (semaglutide and insulin) with standard insulin therapy. Safety outcomes include hypoglycaemia and ketosis. A sample size recalculation during the trial based on analysis of masked data revised the original recruitment target from 114 to 82 participants. CONCLUSION: The TTT1 trial will provide clinically useful information on combination adjunct therapy in the treatment of T1D.

Humans

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236 nm, emission 340 nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125 × 4.0 mm, 5 μm) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8 mL/min. The method showed excellent linearity (r > 0.999) over 0.01-1.0 μg/mL for IMQ and 0.1-2.0 μg/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001 μg/mL for IMQ and 0.004 μg/mL for TBF, with quantification limits of 0.02 μg/mL and 0.16 μg/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000 nM. However, due to carry-over observed at 10,000 nM, the validated calibration range was established at 1-2000 nM, with matrix-dependent LLOQs of 1-10 nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

A homogeneous immunoassay based on AlphaLICA technology for detecting florfenicol residues in animal-derived foods.

Florfenicol (FF), a broad-spectrum amide antibiotic widely used in livestock, poultry, and aquaculture, poses potential threats to food safety and public health due to its residual accumulation. In this study, a novel homogeneous immunoassay based on Amplified Luminescent Proximity Homogeneous Assay (AlphaLICA) technology was developed for the first time for rapid screening of FF residues in milk and egg matrices. By covalently immobilizing the FF-BSA conjugate and goat anti-mouse IgG onto luminescent and photosensitive microspheres, respectively, the method achieved wash-free, homogeneous quantitative detection through a competitive immunoreaction. Under optimized conditions, the assay exhibited a linear range of 0.2-16.2 ng mL-1, with a limit of detection of 9.7 pg mL-1 and a limit of quantification of 183 pg mL-1. The intra- and inter-batch coefficients of variation ranged from 3.08% to 5.70% and 2.44% to 7.09%, respectively. Spike recovery rates in milk and egg matrices ranged from 93.18% to 107.17% (RSD &#x2264; 5.57%). Cross-reactivity with 11 other common antibiotics, including chloramphenicol and thiamphenicol, was below 0.1%, demonstrating excellent specificity. Comparative analysis with a commercial ELISA kit showed high consistency (r2 = 0.9332, p < 0.001). With high sensitivity, strong specificity, simple operation, and a detection time of only 10 min, this method provides a reliable technical platform for high-throughput, rapid monitoring of FF residues in milk and egg matrices.

Journal Article

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3&#xa0;mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100&#xa0;ng/mL (R2&#xa0;&#x2265;&#xa0;0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within &#xb1;15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans

Recent advances in electrode materials for electrochemical detection of zearalenone.

Zearalenone (ZEN) is an estrogenic mycotoxin commonly found in cereals, animal feed, and processed foods, making it an important concern for food safety and public health. Conventional chromatographic and immunological methods can detect ZEN; however, they often require expensive instruments, lengthy sample preparation, and skilled personnel, which restrict their use for rapid and on-site testing. Electrochemical sensors have attracted enormous interest of the scientific community because of their high sensitivity, rapid response, low cost, miniaturization potential, and compatibility with portable systems. The analytical performance of the electrochemical sensors is strongly influenced by electrode materials, morphology, conductivity, porosity, surface functionality, and the efficiency of bioreceptor immobilization. Despite several reviews on mycotoxin detection, a systematic assessment connecting electrode-material design, modification strategies, sensing mechanisms, and electroanalytical performance specifically for ZEN sensing remain limited. This review critically evaluates recent advances in metal oxides, carbon-based materials, metal-organic- and covalent organic frameworks, MXenes, polymers, and hybrid composites for electrochemical ZEN detection. Particular attention has been given to their roles in electron transfer, analyte enrichment, selectivity, and real-sample analysis. The review also compares the major limitations of current sensing systems, including complex fabrication, matrix interference, insufficient long-term stability, poor inter-electrode reproducibility, and limited scalability. Finally, future directions for developing robust, cost-effective, portable, and commercially viable ZEN sensors are discussed.

Journal Article

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Impact of kangaroo care on circadian rhythm, growth, physiological stability in premature infants, and cortisol and melatonin levels in maternal breast milk: A randomized controlled trial.

PURPOSE: This study aimed to examine the effects of regular kangaroo care (KC) on sleep-wake cycles, growth, physiological stability, and maternal breast milk cortisol and melatonin levels in premature infants. DESIGN: This study was a parallel group, single-blind, pre-test-post-test, randomised controlled trial (RCT). METHODS: This randomized controlled study was conducted in a neonatal intensive care unit (NICU) in T&#xfc;rkiye between September 2024 and September 2025 Thirty-six premature infants were randomized to intervention (n = 28) or control (n = 28). Infants in the intervention group received KC for three consecutive days, twice daily (10:00 a.m. and 10:00 p.m.) for 60 min per session. Data were collected using the Infant Information Form, Physiological Parameters Monitoring Chart, and Premature Infant Sleep-Wake Cycles Tracking Chart. Sleep-wake cycles were monitored using a Bispectral Index device. Breast milk cortisol and melatonin levels were measured at baseline and on day three using the competitive ELISA method. The study was registered at ClinicalTrials.gov (NCT06589349). RESULTS: Regular KC had a statistically significant effect on BIS values, heart rate, respiratory rate, oxygen saturation, and body temperature (p < 0.05). No statistically significant effects were observed on infant body weight or on maternal breast milk cortisol and melatonin levels (p > 0.05). CONCLUSION: The findings indicate that regular KC is associated with improved regulation of the sleep-wake cycle and enhanced physiological stability in premature infants. No significant changes were observed in maternal breast milk cortisol or melatonin levels following KC.

Humans

Effectiveness of a digi-physical tool and working method for paediatric obesity treatment in Abu Dhabi: a non-inferiority intervention study using an external historical comparator.

BACKGROUND: Effective paediatric obesity treatment requires high intensity, scalable interventions. A digi-physical tool for paediatric obesity treatment has shown positive results in Stockholm, Sweden. This study evaluates whether the same treatment method is effective in a different cultural setting. METHODS: This non-inferiority intervention study, using an external historical comparator, included 60 consecutively recruited children aged 6-15.9 years with obesity who initiated treatment at Sheikh Shakhbout Medical City in Abu Dhabi between June and December 2023. Patients were treated with Evira, a digi-physical tool and working method enabling high intensity individualized care, real-time monitoring, and interactive patient-clinician communication. The primary outcome was BMI z-score change at 26 weeks. Non-inferiority was assessed using a predefined margin of 0.10 BMI z-score, with outcomes compared to a prior published trial in Stockholm (n&#x2009;=&#x2009;107). RESULTS: A total of 112 children were included in the analysis (Abu Dhabi cohort, n&#x2009;=&#x2009;35; Stockholm cohort, n&#x2009;=&#x2009;77). The adjusted mean change in BMI z-score was -&#x2009;0.20 (95% CI: -&#x2009;0.28, -&#x2009;0.12) in the Abu Dhabi cohort and -&#x2009;0.20 (- 0.26, -&#x2009;0.14) in the Stockholm cohort (p&#x2009;=&#x2009;0.88). Non-inferiority was confirmed, (predefined margin 0.10 was not exceeded). A clinically significant BMI z-score reduction (&#x2265;&#x2009;0.20 units) was achieved by 45.7% of participants in Abu Dhabi and 36.4% in Stockholm (p&#x2009;=&#x2009;0.35). Non-retention rates at 26 weeks were 41.7% vs. 28.0%, respectively (p&#x2009;=&#x2009;0.07). CONCLUSIONS: The findings provide promising evidence that treatment outcomes achieved with the digi-physical treatment tool were comparable in the Abu Dhabi and Stockholm cohorts, supporting its feasibility in a second cultural and healthcare setting.

Humans

Comparison of paralog identification methods and their impact on species tree topologies in target capture phylogenomics within the Sindora clade (Detarioideae: Leguminosae).

Target capture is a common method of generating high throughput DNA sequencing data for phylogenetic reconstruction of species relationships, for which single copy genes are usually most informative. However, a pervasive problem with target capture is that putatively single copy genes may in fact be paralogs resulting from gene duplication, which are problematic for phylogenetic inference because their evolutionary history may differ from the divergence history of species. Here, we use as a case study a target enrichment dataset of 88 species of Detarioideae (Leguminosae) with a focus on the Sindora clade to examine approaches for handling paralogs, including the built-in paralog handling functions in HybPiper and CAPTUS, plus subsequent steps using Putative Paralog Detection and the tree-based Yang & Smith orthology inference approach. We compare the paralogs flagged using these methods and verify their performance with BLAST mapping against a reference genome sequence of Sindora glabra, and then subsequently compare the species tree topologies produced across these methods. Our comparisons of paralogs flagged across the Sindora clade show that the Putative Paralog Detection pipeline was the most accurate in identifying paralogs in terms of its similarity to the BLAST mapping, followed by the built-in paralog identification function of CAPTUS. However, the results we recovered for the Detarioideae subfamily suggest that the largest differences in species tree topology resulted from the use of paralog-filtered alignments (such as with the Putative Paralog Detection pipeline and the Yang & Smith orthology inference approaches) rather than just by removing the sequences of identified paralogous genes. This was the true for HybPiper-assembled datasets but was not seen in CAPTUS-assembled datasets. In all comparisons, the topological differences caused by different paralog handling methods tended to be confined to clades where processes such as hybridisation and introgression are prevalent. Our study provides a roadmap to establish the best approach to identify, eliminate or separate paralogs in the absence of a chromosomally contiguous reference genome for a study group, and highlights the importance of careful data inspection and processing in addition to understanding the extent of paralogy and paralog characteristics (e.g. sequence divergence between copies) for their study group.

Phylogeny

Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients.

OBJECTIVE: To explore agreement between self-report and objectively measured adherence to brace wearing by patients with knee osteoarthritis. METHOD: A single-arm observational analysis nested within the PROP OA randomised controlled trial (ISRCTN28555470). Of 237 adults with symptomatic knee osteoarthritis randomised to brace treatment, 60 were included in this sub-study investigating three different methods of assessing knee brace wear time over 26 weeks: 1. Self-report questionnaires (SRQ) at 12 weeks and 26 weeks; 2. Short message service (SMS) questions (days worn in past week, typical hours per day when worn) administered from week 1 to week 24; 3. A skin temperature sensor embedded in the brace, sampling every 10&#x202f;min for 26 weeks. The presence and reason for the sensor were concealed from participants. The estimated proportion of participants meeting "minimum brace use", defined a priori as &#x2265;1&#x202f;h on &#x2265;2 days in past week, was described for each measurement method, overall and by brace type (unloader, neutral). For temperature sensor measurements, time spent above 24&#xb0;C and time spent above 25&#xb0;C were used. Agreement between the measures was summarised by percentage agreement and kappa (&#x138;). RESULTS: The estimated proportions of participants meeting "minimum brace use" at 12 weeks were 83% (SRQ), 83% (SMS), 60% and 58% (temperature sensor, 24&#xb0;C and 25&#xb0;C thresholds, respectively). At 26 weeks, the corresponding estimates reduced to 72%, 71% (SMS at 24 weeks), 43% and 37%. Sensor data suggested the sharpest decline in brace use occurred within the first 12 weeks. Agreement between self-report measures was higher than between self-report measures and sensor (SRQ vs SMS at 12 weeks: 92% agreement, &#x138;=0.67 (95%CI: 0.34, 1.00); SRQ vs Sensor at 12 weeks: 74%, 0.35 (0.10, 0.60); SMS vs Sens at 12 weeks: 76%, 0.36 (0.05, 0.66). Agreement between all measurement methods reduced at 26 weeks. CONCLUSIONS: This novel use of a temperature sensor to monitor brace adherence in knee osteoarthritis indicates that self-report adherence substantially overestimates knee brace wearing time, with implications for clinical trials and practice.

Humans

Measuring economic efficiency in adult intensive care units: A systematic review of methods, metrics, and evidence.

OBJECTIVES: Intensive care units (ICUs) consume substantial hospital resources, yet "efficiency" is inconsistently defined and measured. This study systematically reviewed how economic efficiency has been conceptualised and quantified in adult ICUs and appraised the quality of evidence. METHODS: Following PRISMA 2020 and a PROSPERO-registered protocol (CRD420251107866), we searched MEDLINE, Embase, CINAHL, Cochrane Library and Web of Science (2000-August 2025), plus global grey sources. Eligible studies explicitly defined efficiency and reported an efficiency metric/model linking ICU inputs (e.g., staff, beds/capacity, time, consumables, or costs) to outputs/outcomes (e.g., throughput/discharges, length of stay/resource use, risk-adjusted mortality). Dual independent screening and extraction were performed. Study quality was appraised using MMAT, and findings were synthesised narratively (SWiM), given heterogeneity. RESULTS: 39 studies (2001-2025) from 17 countries were included, all from high-income or upper-middle-income settings. Four methodological families were identified: (1) frontier modelling (predominantly DEA; occasional SFA/RFDH), (2) benchmarking indicators (risk-adjusted mortality and LOS/resource-use ratios; "efficiency matrix" quadrant classification), (3) cost-outcome evaluations, and (4) operational/process metrics. Across families, variation in decision-making units, input/output selection, and risk adjustment limited comparability; long-term and patient-reported outcomes were absent, and equity considerations were uncommon. CONCLUSIONS: ICU efficiency research is feasible but fragmented and often methodologically limited. Standardised definitions, validated risk adjustment, uncertainty quantification, and inclusion of patient-centred and equity-relevant outcomes are needed before efficiency metrics can reliably inform value-based decision making.

Intensive Care Units

A systematic review of human avoidance learning: Cognition, computation, and methods.

Avoidance behaviour is fundamental for survival but can become maladaptive in clinical conditions. A large body of literature has accumulated on the dynamics of human avoidance learning. However, current theories and overviews do not provide an exhaustive account of this evidence. In this systematic review, we identify N = 116 studies on human avoidance learning. We analyse these studies with the goal of distilling robust empirical phenomena as a basis for theory-building, and examine their diagnostic value in differentiating between competing theories. We find that the evidence is difficult to reconcile with foundational two-factor and classical safety-signal accounts, and most strongly supports expectancy- and inference-based views, in which avoidance responses are selected with respect to represented consequences. At the same time, no current framework provides a complete account of the evidence: several findings point to an additional role for operant valuation, Pavlovian influences, and contextual or latent-state control over the expression of avoidance. Methodologically, we observe that the problem setting in the most common experimental paradigms is radically simpler than real-world avoidance and therefore unlikely to expose the limits of inferential or reflective mechanisms. Consequently, we argue that paradigms with greater computational demands and more realistic action affordances are required to identify the mechanisms underlying avoidance learning. Collectively, these insights provide a foundation for theoretical refinement, computational modelling, and methodological innovation, with implications for advancing interventions targeting maladaptive avoidance.

Humans

Routine methods misidentify Serratia spp.: Limitations of MALDI-TOF MS revealed by whole-genome sequencing.

Accurate species-level identification within the genus Serratia remains challenging due to extensive phenotypic overlap and high genomic relatedness among closely related and recently described taxa. This study presents an evaluation of routine and genome-based identification approaches applied to clinical Serratia isolates, integrating phenotypic assays, MALDI-TOF MS (Bruker Daltonics), 16S rRNA gene sequencing, and Whole-Genome Sequencing (WGS). A total of 103 isolates collected from a teaching hospital were analyzed. WGS was performed on a subset of isolates. Conventional biochemical methods classified all isolates as Serratia marcescens, whereas MALDI-TOF MS identified 60.1% as S. marcescens, 11.6% as S. ureilytica, and 28.1% just at the genus level. Peak analysis from MALDI-TOF MS revealed specific peaks associated with S. marcescens and S. ureilytica, but limited discriminatory power. WGS of six isolates initially identified as S. ureilytica by MALDI-TOF MS revealed reclassification as Serratia sarumanii (n = 5) and Serratia montpellierensis (n = 1), supported by Average Nucleotide Identity (ANI), Average Amino Acid Identity (AAI), and Digital DNA-DNA Hybridization (dDDH) thresholds. In contrast, 16S rRNA analysis showed limited species-level resolution. Phylogenomic and SNP-based analyses confirmed these classifications with strong support. Overall, this study underscores the critical role of high-resolution genomic approaches for precise species identification and highlights the need for continuous expansion and curation of MALDI-TOF MS reference databases to support reliable clinical diagnostics and epidemiological surveillance of emerging Serratia species.

Spectrometry, Mass, Matrix-Assisted Laser Desorpti

Systematic review of microorganism disinfection performance by chemical and ultraviolet light water treatment methods.

Safe drinking water is critical for public health, yet microbial contamination remains a significant global challenge. We conducted a systematic review to update World Health Organization guidance on water disinfection technologies by synthesizing peer-reviewed literature from 1997 to 2021 on the performance of free chlorine, chlorine dioxide, ozone, and ultraviolet (UV) light against bacteria, viruses, and protozoa. Following PRISMA guidelines, we analyzed log10 reduction values (LRVs) and contact times (Ct) or fluence (for UV) from laboratory and field studies. We included studies from multiple databases and expert-recommended studies. Results show mean Cts for 2 LRV of non-opportunistic bacteria as 6.0 (free chlorine), 0.4 (chlorine dioxide), and 1.2 (ozone) mg/L*min, and a mean UV fluence of 8.2 mJ/cm&#xb2; (all bacteria). Viruses required lower Cts, except for UV-resistant adenoviruses, while protozoa required higher Cts or fluences. Opportunistic bacteria required significantly higher Cts than non-opportunistic bacteria for free chlorine and chlorine dioxide. Temperature and pH effects were inconsistent, highlighting data variability and gaps in field studies. These findings support global guidance on water treatment and may be used alongside other context-specific data to understand the roles these technologies play in reducing waterborne exposures. We recommend standardized reporting from performance studies to enable straightforward synthesis of evidence.

Disinfection

Evaluation of one-step amplicon-based targeted enrichment for SARS-CoV-2 whole-genome sequencing using the Midnight amplicon scheme.

Genomic surveillance proved invaluable during the COVID-19 pandemic for tracking SARS-CoV-2 variants and guiding outbreak responses, underscoring the ongoing need to reduce whole-genome sequencing (WGS) costs and improve workflow efficiency to ensure accessibility in resource limited settings. Here, we evaluated a one-step reverse transcription polymerase chain reaction (RT-PCR) approach using the Midnight V2 primer scheme for targeted amplification of the SARS-CoV-2 genome, assessed its compatibility with Illumina sequencing, and compared its performance to a well-established two-step method. Initially, we determined optimal RT-PCR reaction conditions using the Midnight V2 primer panel for the one-step RT-PCR kit and scaled reaction volumes for both RT-PCR and library preparation. Clinical specimens (n&#x202f;=&#x202f;53) that had undergone routine WGS for surveillance purposes using the established two-step RT-PCR method were compared using the one-step RT-PCR assay. For samples with genome completeness greater than 70%, both methods gave comparable results with similar sequence coverage and 100% concordance for lineage assignment. Further investigation revealed a higher percentage of reads aligning to the SARS-CoV-2 genome with a greater depth of coverage using the one-step method compared to the two-step method. Finally, analysis of scaled one-step and library reaction volumes revealed significant cost savings for samples undergoing WGS. Overall, the results presented here verify the accuracy and reproducibility of one-step targeted amplification and offer an efficient and cost-effective workflow for routine SARS-CoV-2 genomic surveillance.

Humans