Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “systems drift”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Measurement of intracompartmental pressure with use of a new electronic transducer-tipped catheter system.

Laboratory and clinical tests were carried out to determine the clinical usefulness, validity, and safety of a new self-calibrating, battery-powered monitoring system for the measurement of intramuscular pressure with use of an electronic transducer-tipped catheter. The eight probes accurately recorded applied pressures ranging from zero to 160 millimeters of mercury (zero to 21.33 kilopascals). The system registered little temperature-induced drift (maximum, 1.25 millimeters of mercury [0.17 kilopascal]) between dry room temperature and 40 degrees Celsius. There were also minimum variations (range, -0.14 to 0.81 millimeter of mercury [0.02 to 0.11 kilopascal]) in the pressures recorded during a twenty-four-hour period. The resting pressure in the tibialis anterior muscle of twenty volunteers who had normal limbs was a mean (and standard deviation) of 13.1+/-8.3 millimeters of mercury (1.75+/-1.11 kilopascals). There was a good correlation between externally applied pressures (zero, twenty, forty, sixty, eighty, and 100 millimeters of mercury [zero, 2.67, 5.33, 8.00, 10.66, and 13.33 kilopascals] applied with use of antishock trousers) and the pressures measured in the tibialis anterior muscle of four volunteers (r = 0.997 to 0.999). The injection of sterile saline solution into the tibialis anterior muscle of a volunteer and the use of high-frequency recording during muscular activity showed a high degree of responsiveness and sensitivity to changes in intramuscular pressure. We also prospectively evaluated the clinical usefulness of the system and found it to be easy to assemble, calibrate, and use. Thus, this reusable, electronic transducer-tipped catheter system, which is based on a noninfusion technique, is simple, minimally traumatic, and highly precise. It is free of hydrostatic pressure artifacts and provides dynamic responses to changes in intramuscular pressure.

Adult↗

Latanoprost. Two years' experience of its use in the United Kingdom. Latanoprost Study Group.

OBJECTIVE: The aim of the study was to assess the efficacy and safety of latanoprost in the long-term treatment of glaucoma. DESIGN: The study was designed as a randomized, 6-month double-masked parallel group, multicenter study comparing latanoprost with timolol followed by an 18-month open-label, multicenter study in which all patients were treated with latanoprost. PARTICIPANTS: In total, 277 patients were treated with latanoprost for up to 24 months. INTERVENTION: For the first 6 months of treatment, latanoprost (0.005%) administered once daily was compared with timolol (0.5%) administered twice daily. Patients then received latanoprost (once daily) for an 18-month follow-up period regardless of their initial treatment. MAIN OUTCOME MEASURES: Intraocular pressure (IOP) was measured over the 24-month treatment period, and any ocular-systemic symptoms or adverse events were evaluated. RESULTS: Latanoprost significantly reduced (P < 0.001) IOP by approximately 8 mmHg from pretreatment values, and this reduction was maintained over the 24-month treatment period with no sign of upward drift. Latanoprost is apparently free of any systemic side effect. The most significant ocular side effect with latanoprost was an increase in iris pigmentation, which occurred in 51 patients. CONCLUSIONS: Latanoprost, administered once daily, is effective and well tolerated for the long-term treatment of patients with open-angle glaucoma or ocular hypertension.

Adrenergic beta-Antagonists↗

A capacitance pressure sensor using a phase-locked loop.

We are using a Hercules (model #F4-4R, 100 psi) pressure sensor to measure the pressure between the foot and shoe. An interface circuit converts the capacitance change into voltage. Over the pressure range from 0 to 1300 kPa, the capacitance changes from 275 to 580 pF. A 555 timer circuit converts the capacitance into a frequency range from 30 to 63 kHz. A phase-locked loop (PLL) converts this frequency to voltage from 0 to 5 V, which is then filtered using a first-order, low-pass filter, having a corner frequency of 20 Hz to reduce the ripple to 10 mV. The sensor's hysteresis is about 8 percent at 40 degrees Celsius (C) and 12 percent at 20 degrees C. The sensor has a maximal nonlinearity of 8 percent and a worst-case nonrepeatibility of 7 percent. Its temperature coefficient is -0.147 percent per degree C. Its spatial sensitivity decreases nonlinearly from 1 to 0.17 from the center towards the periphery. The sensitivity of the system is 2.77 mV/kPa and the temperature drift is +0.53 percent per degree C. We monitor the pressure at 7 locations under each foot (the rear and the front heel, great toe, and 4 of the 5 metatarsal heads). A portable data-acquisition system permits continuous monitoring for 7 minutes. Test results for pressure distribution for normal walk and run are presented. Results are useful when studying normal and abnormal gait, and for possibly providing feedback (sensory substitution) to diabetic patients with insensate feet in order to help them dynamically adjust pressure distribution under their feet.

Biomechanical Phenomena↗

Temperature-dependent solute retention time variations, base-line drifts, and solute peak splits during the analysis of fenvalerate by a high-performance liquid chromatography/diode array system.

The optical isomers of fenvalerate, (RS)-alpha-cyano(3-phenoxyphenyl)methyl (RS)-2-(4-chlorophenyl)-3-methylbutyrate, were analyzed by high-performance liquid chromatography (HPLC) on chiral columns eluted with mixtures of 2-propanol in hexane. The HPLC eluates were monitored by a photodiode-array ultraviolet absorbance detector. When the HPLC columns were maintained at ambient temperature, chromatograms with drifting base lines of four to eight peaks, instead of four, and isograms, three-dimensional chromatograms, with "negative" peak artifacts coeluted with fenvalerate isomers were usually obtained during a continuous run of the HPLC system for many days and by injecting onto the system only fenvalerate analytical standard solutions. Chromatograms and isograms without artifacts and straight base lines were obtained only when the HPLC column was thermostated and well equilibrated for at least 8-10 h.

Chromatography, High Pressure Liquid↗

The effect of respiration on the performance of the total artificial heart.

An electromechanical driven pusher plate type total artificial heart (TAH) has been developed in the Department of Surgery at Baylor College of Medicine. The control of this TAH is based upon Frank-Starling's law, and the output is likely to be affected by the respiration cycle. The necessity of an averaging system for the pumping to avoid this drifting of the output has been discussed in several papers. In this study, the effect of respiration on the performance of the TAH was evaluated in both in vitro and in vivo conditions. This TAH was driven without an averaging system in its control system. The results indicated that the mean output pressure was stable with minute changes in both the heart rate and outflow. This verifies that the electromechanical driven pusher plate type TAH, which is under development in our laboratory, compensated for the effect of respiration without an averaging system.

Animals↗

Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging.

Spectral quality in 1H magnetic resonance spectroscopic imaging (MRSI) critically depends on the stability of the main magnetic field. For echo-planar MRSI implemented at 3 T, temperature variation in the passive steel shims of the magnet system can lead to a significant drift in the resonance frequency. A method is presented that incorporates interleaved measurement of the instantaneous resonance frequency of a reference water signal into a volumetric MRSI sequence and allows correction for the drift during postprocessing. Results from normal human brain at 3 T indicate that the correction largely removes lineshape distortions, recovers metabolite signal loss, and improves spectral quality by reducing the width of spectral lines; however, particularly in inferior regions, other sources of distortion may be present that cause broadening of spectral lines.

Algorithms↗

Characterization of synthetic carrier ampholytes by repetitive scanning of the electric field during focusing.

This paper reports the utilization of a potential gradient array detector for monitoring the dynamics of the electric field during isoelectric focusing. Transient and steady state electric field profiles are presented for synthetic carrier ampholyte mixtures with a wide (approximately 3-10) pH range. Two available commercial products (Ampholine and Pharmalyte) and a laboratory synthesized mixture (PEHA ampholytes) are compared. The formation of conductivity gaps and their migration toward the cathode in extended experiments (cathodic drift) can be visualized with this system.

Ampholyte Mixtures↗

A controlled study of a new ECG electrode system.

A newly marketed resting ECG electrode system was compared with conventional metal suction and plate electrodes, electrode cream and patient cable. Two experienced technicians were given special training in the use of the new electrode, electrolyte and patient cable system and alternated daily in using new and conventional equipment. Nearly equal numbers of perfect-scoring ECGs were recorded with each system, attesting to the impartiality of the technicians. A total of 1,062 ECGs were evaluated, 554 with the new system and 508 with the conventional one. ECG tracings were evaluated by electrocardiographers unaware of which system was used for each. A quantitative scoring system was used to measure the technical quality of each tracing in terms of baseline drift, powerline artifact and myographic plus miscellaneous artifacts. The new system received mean scores of 2.33, 3.08, and 2.72, respectively, while the conventional electrodes received scores of 2.56, 3.03 and 2.79. We concluded that the two types of electrodes produced ECGs of essentially equal quality.

Electrocardiography↗

[Monitoring of intracranial pressure with intraparenchymal fiberoptic transducer. Technical aspects and clinical reliability].

A fiberoptic intracranial pressure transducer (Camino) was assessed prospectively in 100 patients. In all, 122 sensors were inserted intraparenchymally at the bedside, without the help of a neurosurgeon. Before the procedure, patients were given 2 to 4 mg of phenoperidine. The scalp was opened over a few millimeters in the frontal paramedian area. A burr holc was made with a 2 mm bit. The dura mater was opened and a hollow screw inserted in the diploë. When the zero of the transducer had been obtained, a 5 cm length was inserted within the screw. The transducer was then about 5 mm deep within cerebral parenchyma. The procedure took an average of about 15 min. An intracerebral haematoma around the transducer occurred five times. One had to be drained surgically. There were no infectious complications. The daily baseline drift was about 0.3 mmHg. The system seemed to be reliable: there was close agreement between the intracranial pressure (ICP), neurological status and CT scan findings. In trauma cases, there was also good correlation between mean ICP and the basal cistern obliteration score, finally, ICP became equivalent to mean arterial blood pressure in all brain dead patients. It is concluded that this system may be used in all cases where ICP requires to be monitored, even when the lateral ventricles are no longer visible, or when craniotomy has been performed. This will most probably result in a more extended use of ICP monitoring in neurosurgical intensive care.

Adolescent↗

Effects of microdialysis catheter insertion into the subcutaneous adipose tissue assessed by the SCGM1 system.

To monitor glucose in patients with diabetes continuously a microdialysis-based glucose sensor system (SCGM1 System, Roche Diagnostics GmbH, Mannheim, Germany) is under clinical development. This system allows monitoring of glucose levels in the subcutaneous interstitial fluid of patients with diabetes for a maximum duration of up to 120 h. The aim of the study was to determine the effect of microdialysis catheter insertion on the stability of the SCGM1 System glucose sensor signal. At four study sites, 47 experiments with the prototype of the novel SCGM1 System were performed in 42 patients with type 1 diabetes; two additional experiments were performed in two healthy volunteers. The microdialysis catheter was inserted in the subcutaneous adipose tissue of the patients in order to measure the glucose concentration in the interstitial fluid continuously. The catheter was perfused with a pump rate of 0.3 microL/min. For method comparison capillary blood glucose measurements were performed as reference values. In addition, the skinfold thickness was measured. Out of the total of 49 experiments 34 were usable. The average monitoring time in these experiments was 106.0 +/- 14.3 h (mean +/- SD). However, for this study the data from the first study day were evaluated in more detail. The analysis showed that during the first 12 h after catheter insertion the sensor signal increased 20% in comparison with the capillary blood glucose values (normalized calibration factor). This leads to a lower normalized calibration factor compared with the following study days. It remains stable in the time thereafter. The skinfold thickness showed no significant effect on the sensor signal. The observed increase in sensor signal in the first hours after insertion of the microdialysis catheter was probably due to a local trauma, which can induce an inflammation reaction. Thereafter, the signal registered by the SCGM1 System was stable and free of drift to the end of the experiment.

Adult↗

Patterns of hybridization and population genetic structure in the terrestrial orchids Liparis kumokiri and Liparis makinoana (Orchidaceae) in sympatric populations.

We investigated the potential for gene flow and genetic assimilation via hybridization between common and rare species of the terrestrial orchid genus Liparis, focusing specifically on sympatric and allopatric populations of the common Liparis kumokiri and the rare Liparis makinoana. We utilized analyses of genetic diversity, morphology, and the spatial distributions of individuals and genotypes to quantify the dynamics of interspecific gene flow at within- and among-population scales. High levels of allozyme genetic diversity (HE) were found in populations of the rare L. makinoana (0.317), whereas the common L. kumokiri (N = 1744 from 14 populations) revealed a complete lack of variation. This contrast may reflect different breeding systems and associated rates of genetic drift (L. makinoana is self-incompatible, whereas L. kumokiri is self-compatible). At the two known sympatric sites, individuals were found that recombined parental phenotypes, possessing floral characteristics of L. kumokiri and vegetative characteristics of L. makinoana. These putative hybrids were the only individuals found segregating alleles diagnostic of both parental species. Analysis of these individuals indicated that hybrid genotypes were skewed towards L. kumokiri and later generation recombinants of L. kumokiri at both sympatric sites. Furthermore, Ripley's bivariate L(r) statistics revealed that at one site these hybrids are strongly spatially clustered with L. kumokiri. Nonetheless, the relatively low frequency of hybrids, absence of ongoing hybridization (no F1s or first generation backcrossess), and strong genetic differentiation between morphologically 'pure' parental populations at sympatric sites (FST = 0.708-0.816) indicates that hybridization was not an important bridge for gene flow. The results from these two species suggest that natural hybridization has not played an important role in the diversification of Liparis, but instead support the view that genetic drift and limited gene flow are primarily responsible for speciation in Liparis. Based on genetic data and current status of the species, implications of the research for conservation are considered to provide guidelines for appropriate conservation and management strategies.

Conservation of Natural Resources↗

Analysis of tooth movement into an extraction space in the rat.

The purpose of this study was to evaluate the amplitude, direction and nature (translation or rotation) of the movements of teeth bordering an extraction site. Two experimental approaches were used. In one series of experiments, second maxillary molars were removed in 10 anaesthetized rats. To allow precise measurements of tooth movement into the extraction space, small cavities were drilled in the proximal surfaces of the first and third molars facing the gap. An elastomer impression was taken and the distance between the two cavities was recorded. This measurement was repeated 1, 2 and 3 months later. After killing the rats, the skulls were dried. The direction of movement was observed on occlusal photographs, and lateral X-rays were used to evaluate the nature of the drift (translation or rotation) observed. To evaluate the impact of occlusal forces on the tooth movements, a second experimental system was used in which the antagonistic occlusal contacts on the test side were removed (12 rats). In the first experiments, the average reduction of the extraction gap was 40.7 +/- 1.8% of the initial value, and in the second experiment, 44.7 +/- 3.3%. In both experimental systems the movement was derived largely from a mesial drift of the third molar, and its rate decreased with time. Furthermore, the drift of the third molar comprised one-third rotation and two-thirds translation. Student's t-test showed no influence of occlusal forces on the tooth movements.

Analysis of Variance↗

A mountain-scale thermal-hydrologic model for simulating fluid flow and heat transfer in unsaturated fractured rock.

A multidimensional, mountain-scale, thermal-hydrologic (TH) numerical model is presented for investigating unsaturated flow behavior in response to decay heat from the proposed radioactive waste repository in the Yucca Mountain unsaturated zone (UZ), The model, consisting of both two-dimensional (2-D) and three-dimensional (3-D) representations of the UZ repository system, is based on the current repository design, drift layout, thermal loading scenario, and estimated current and future climate conditions. This mountain-scale TH model evaluates the coupled TH processes related to mountain-scale UZ flow. It also simulates the impact of radioactive waste heat release on the natural hydrogeological system, including heat-driven processes occurring near and far away from the emplacement tunnels or drifts. The model simulates predict thermally perturbed liquid saturation, gas- and liquid-phase fluxes, and water and rock temperature elevations, as well as the changes in water flux driven by evaporation/condensation processes and drainage between drifts. These simulations provide insights into mountain-scale thermally perturbed flow fields under thermal loading conditions.

Computer Simulation↗

A flow injection microdialysis sampling chemiluminescence system for in vivo on-line monitoring of glucose in intravenous and subcutaneous tissue fluid microdialysates.

A novel flow injection on-line microdialysis system for in vivo monitoring of glucose in subcutaneous tissue fluid and blood is described. An implantable loop-type microdialysis probe was used for subcutaneous sampling, and a flow-through microdialyzer was used for intravenous sampling by pumping of the blood from the tested rabbit through the microdialyzer located outside the living system at a flow rate of 10 microL/min. The perfusion rate of the dialysate was 20 microL/min. The glucose in the dialysate was detected on-line with a flow injection chemiluminescence system after passing through an immobilized glucose oxidase reactor. The calibration of the detector system (including reactor) and monitoring of baseline drifts were performed simultaneously to improve the reliability of the monitoring process. The dialysate sample volume was 20 microL, and the sample throughout was 28 h-1. The variation of glucose level in subcutaneous tissue fluid and blood of the rabbits was monitored after the administration of glucose or insulin to demonstrate the favorable resolution and reliability of the system for in vivo on-line monitoring.

Animals↗

Indirect fluorescence detection of phenolic compounds by capillary electrophoresis on a glass device.

A micromachined capillary electrophoresis system has been fabricated on a glass device for the separation and indirect fluorescence detection of phenols. Using this device two phenols viz., 2,4-dichlorophenol and pentachlorophenol, were separated within 12 s compared to under 19 min on a conventional capillary electrophoresis system using direct ultraviolet detection. The precision of the glass device ranged from 12.7%-16.7% compared to 0.42%-4.9% for the conventional system. Both systems showed good linearity in the concentration range of 0.8-6.38 mM for the glass device and 5-130 microM for the conventional system. The relationship between temperature and high voltage with baseline drift was also investigated. These results provide a foundation for the development of a miniaturised chemical analysis system for the on-line analysis of phenols in water.

Journal Article↗

The dynamics of indirect reciprocity.

Richard Alexander has argued that moral systems derive from indirect reciprocity. We analyse a simple case of a model of indirect reciprocity based on image scoring. Discriminators provide help to those individuals who have provided help. Even if the help is never returned by the beneficiary, or by individuals who in turn have been helped by the beneficiary, discriminating altruism can be resistant against invasion by defectors. Indiscriminate altruists can invade by random drift, however, setting up a complex dynamical system. In certain situations, defectors can invade only if their invasion attempts are sufficiently rare. We also consider a model with incomplete information and obtain conditions for the stability of altruism which differ from Hamilton's rule by simply replacing relatedness with acquaintanceship.

Altruism↗

Scientific validation of two commercial pressure sensor systems for prosthetic socket fit.

The concept of measuring pressure at the interface between the stump and the prosthetic socket could provide valuable information in the process of prosthetic socket fabrication, modification, and fit. Two systems, the Rincoe Socket Fitting System (SFS) and Tekscan's F-Socket Pressure Measurement System, have been commercially designed for in situ interface pressure measurement over the past decade. Their use is not common in prosthetic practice, perhaps due to questions of cost effectiveness and the difficulties of interpreting the data. Another concern is the use of sensors for pressure measurements in areas of high contour and complex geometries such as the stump. Before these systems can be used in a clinical setting, it is necessary to determine the reliability and accuracy of each system. In order to assess the clinical validity of the Rincoe SFS and F-Socket systems, a series of trials was conducted to evaluate different aspects of sensor performance, namely; accuracy, hysteresis, drift and the effect of curvature. The sensors were subjected to tests in flatbed and custom-designed pressure vessels. Overall results indicated an accuracy error for the Rincoe SFS system of 25% (flatbed) and 33% (mould), with a corresponding 15% (flatbed) and 23% (mould) error in hysteresis, and 7% (flatbed) and 11% (mould) drift errors. The F-Socket system demonstrated an 8% (flatbed) and 11% (mould) accuracy errors, 42% (flatbed) and 24% (mould) hysteresis errors, and 12% (flatbed) and 33% (mould) drift errors. These findings indicate favourable results for the F-Socket Pressure Measurement System compared to the Rincoe Socket Fitting System with respect to its accuracy errors only. Nevertheless, it is the authors' belief that these systems are adequate in indicating areas of high pressure at the stump socket interface for clinical purposes, but both systems should be used with caution.

Artificial Limbs↗

Comparative toxicity of chlorothalonil: Ceriodaphnia dubia and Pimephales promelas.

Chlorothalonil is a commonly used fungicide in rural and urban environments and can be incidentally introduced into aquatic systems through rainfall runoff or direct overspray and drift from aerial applications. Few studies have been published regarding risks to aquatic organisms exposed to chlorothalonil, so this study was performed to provide a first-order risk characterization for receiving system biota. Definitive laboratory toxicity tests were conducted with aqueous solutions of chlorothalonil and sentinel aquatic organisms (Ceriodaphnia dubia Richard and Pimephales promelas Rafinesque). P. promelas was more sensitive (7-day potency=6.1% mortality/mug/L) than C. dubia (7-day potency=0.94% mortality/mug/L) to chlorothalonil exposures. All mortality of P. promelas and C. dubia resulting from these chlorothalonil exposures occurred within the first 96h and no sublethal effects (i.e., growth or reproduction) were detected under these experimental conditions following 7-day exposures.

Animals↗