A capacitance pressure sensor using a phase-locked loop.

Abstract

We are using a Hercules (model #F4-4R, 100 psi) pressure sensor to measure the pressure between the foot and shoe. An interface circuit converts the capacitance change into voltage. Over the pressure range from 0 to 1300 kPa, the capacitance changes from 275 to 580 pF. A 555 timer circuit converts the capacitance into a frequency range from 30 to 63 kHz. A phase-locked loop (PLL) converts this frequency to voltage from 0 to 5 V, which is then filtered using a first-order, low-pass filter, having a corner frequency of 20 Hz to reduce the ripple to 10 mV. The sensor's hysteresis is about 8 percent at 40 degrees Celsius (C) and 12 percent at 20 degrees C. The sensor has a maximal nonlinearity of 8 percent and a worst-case nonrepeatibility of 7 percent. Its temperature coefficient is -0.147 percent per degree C. Its spatial sensitivity decreases nonlinearly from 1 to 0.17 from the center towards the periphery. The sensitivity of the system is 2.77 mV/kPa and the temperature drift is +0.53 percent per degree C. We monitor the pressure at 7 locations under each foot (the rear and the front heel, great toe, and 4 of the 5 metatarsal heads). A portable data-acquisition system permits continuous monitoring for 7 minutes. Test results for pressure distribution for normal walk and run are presented. Results are useful when studying normal and abnormal gait, and for possibly providing feedback (sensory substitution) to diabetic patients with insensate feet in order to help them dynamically adjust pressure distribution under their feet.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Patel, M Kothari, J G Webster, W J Tompkins, J J Wertsch. 1989. A capacitance pressure sensor using a phase-locked loop.. https://pubmed.ncbi.nlm.nih.gov/2724153/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple model for the function of proteoglycans and collagen in the response to compression of the intervertebral disc.

The nucleus pulposus of the intervertebral disc exerts a pressure which enables it to support axial compression when contained by the annulus fibrosus. The disc was modelled as a thick-walled cylindrical pressure vessel in which the nucleus was contained radially by the annulus. As a result, the stress in the annulus had radial (compressive) as well as tangential (tensile) components. The radial stress at a given point in the annulus was considered to be balanced by the internal pressure which is expected to arise from the attraction of water by proteoglycans. There was a reasonable agreement between the calculated radial stress distribution and published results on the distribution of water within the annulus. As the internal pressure is expected to be isotropic, the annulus was expected to contribute to the axial resistance to compression of the disc; this contribution would be equal, in magnitude, to the radial stress. Predictions of the pressure distribution within the annulus were similar to published experimental measurements made in the radial and axial directions. The tangential stress within the annulus was considered to arise from the restoring stress in its strained collagen fibrils.

Biomechanical Phenomena

Flow-induced prostacyclin production is mediated by a pertussis toxin-sensitive G protein.

Fluid flow and several other agonists induce prostacyclin (PGI2) production in endothelial cells. G proteins mediate the response of a large number of hormones such as histamine, but the transduction pathway of the flow signal is unclear. We found that GDP beta S and pertussis toxin inhibited flow-induced prostacyclin production in human umbilical vein endothelial cells. In addition, flow potentiated the histamine-induced production of PGI2. This suggests that flow stimulates prostacyclin production via a pertussis toxin-sensitive G protein and modulates the stimulus-response coupling of other agonists.

Biomechanical Phenomena