Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Diagnostic performance of segmental plethysmography and Doppler ultrasound in obliterating vascular diseases in the lower limbs.

The diagnostic value of three noninvasive techniques was evaluated in a group of 100 "normal" and 100 "abnormal" limbs. The choice of segmental plethysmography, systolic pressure determination, and Doppler velocity curve was based on the fact that these methods are noninvasive, inexpensive, and atraumatic; they can easily be performed by paramedical personnel. There was a statistically significant difference between the ankle-to-arm systolic blood pressure ratio of normals and abnormals as measured by Doppler ultrasound with 0.96 as the dividing line, no false positives and only 11% false negatives were found. However, there was a large overlap for many parameters calculated from the velocity curve. The general morphological aspect of the velocity curve shows a better diagnostic performance than the calculated parameters of this curve: a monophasis curve had an 85% chance of being normal. The ankle segmental plethysmogram yielded only 5% false negatives, but 20% false positives; moreover, a biphasic curve has a 90% chance of being normal. Thus large-scale screening in clinical practice or in epidemiologic studies can best be done by Doppler pressure measurements; the velocity curve performs less satisfactorily. Segmental plethysmography is more sensitive, but it yields more false positive results.

Blood Pressure↗

Map representation and diagnostic performance of the standard 12-lead ECG.

The diagnostic information contained in the standard 12-lead electrocardiogram was assessed by comparing the classification results produced by the standard leads for various clinical settings, such as normal versus myocardial infarction or versus left ventricular hypertrophy to those achieved by 120-lead data or body surface potential maps (BSPMs). Separately, optimal signal leads were extracted from the BSPM by ranking all leads in function of their capability of reconstructing the BSPM. Ranking was achieved by deriving eigenvalues from the covariance matrix calculated from all leads and corresponding measurements. Thus, while comparing the results from the standard leads (diagnostic leads) to those from the original raw map data, a comparison was also performed with respect to the best signal leads, namely the four best and the eight best. From the results observed for all bi- and multigroup classifications, it appeared that the diagnostic yield of the 12 standard leads matched those obtained with a number of signal leads lying between 4 and 8. This indicated that a large overlap still existed between the leads composing the 12-lead ECG (in fact, only 8 independent leads). Another interesting observation resulted from this investigation: although classifiers (discriminating variables) used for classification were identical, whether they originated from the raw standard leads (derived from the raw maps) or from standard leads reconstructed with four or eight signal leads, reconstructed measurements performed better than original measurements. This paradox can be explained by looking at the respective F values. Indeed, since increased F values result from higher ratios between the difference of group means and the composite variance from the pooled groups, higher differences and/or smaller variances produce larger ratios and hence, better group separations.

Body Surface Potential Mapping↗

[Relevance of a performance capacity model for uniform and standardized performance diagnostics].

To obtain a standardized method for performance capacity assessment in social medicine reference to a generally accepted model of performance capacity is necessary. Further, such a model enables description of the effects of chronic disease on performance capacity. This article describes how the term "performance capacity" can be reduced to operational basal parameters by a hierarchic breakdown, with the domain "physical performance capacity" having the most complex structure. Furthermore the construction of a graduation according to work-load taxonomies for every parameter is shown. The collection of data on the level of basal parameters is essential to assess the concrete performance capacity. To apply the model as a basis for estimating the effects of chronic disease, graduated disease features have to be created. The benefit of the procedure described lies in increased transparency of the decision process. Hence, performance capacity assessment will gain reliability and objectivity.

Chronic Disease↗

Use of Iliad to improve diagnostic performance of nurse practitioner students.

Nurse practitioners (NPs) have dual goals as primary care providers, combining the traditional goals of nursing with extended goals as diagnosticians. Diagnostic reasoning, therefore, is a critical component of NP education. Iliad, a computerized diagnostic reasoning expert system, has been used effectively to teach diagnostic skills to medical students. A pilot study was undertaken to determine the effects of Iliad training on NP students' diagnostic skill performance and to identify technical and instructional issues of implementation. The study found that the use of Iliad improved NP students' diagnostic reasoning, and that the training effects were modified by prior nursing experience. Successful use of Iliad required planning, faculty commitment, and technical support.

Clinical Competence↗

Clinical value of cell counts and indices in testicular fine needle aspiration cytology in primary infertility: diagnostic performance compared with histology.

OBJECTIVE: To compare the diagnostic value of testicular fine needle aspiration (FNA) cytology with that of open biopsy in primary infertility and nonobstructive azospermia or severe oligozoospermia, to evaluate the reliability of percentage cell counts and cell indices. STUDY DESIGN: Thirty patients (21 azospermic and 9 severe oligozoospermic) who had samples for testicular FNA obtained from both testis (mean age = 28.7) and open biopsy were included in the prospective study. Primary infertility, history, complete physical examination, hormonal assay and testicular ultrasound data were evaluated. One case was excluded because of an unsatisfactory result in aspiration cytology. The percentage population of Sertoli cells and spermatogenetic cells, in addition to spermatic index, sertoli cell index and sperm-Sertoli cell indexes, was calculated. The statistical analysis was determined using the paired t test. RESULTS: Progressively increasing values of the Sertoli cell index and progressively decreasing values of the sperm--Sertoli cell index were seen in maturation arrest, hypospermatogenesis and Sertoli cell-only syndrome. The difference between mean counts and indices in normal spermatogenesis and other histologic categories was statistically significant (p < 0.05). CONCLUSION: Percentage cell counts and cell indices in testicular FNA significantly correlate with histological categories. In primary male infertility, testicular FNA can be performed instead of open biopsy.

Adult↗

Effect of soft-copy display supported by CAD on mammography screening performance.

Diagnostic performance and reading speed for conventional mammography film reading is compared to reading digitized mammograms on a dedicated workstation. A series of mammograms judged negative at screening and corresponding priors were collected. Half were diagnosed as cancer at the next screening, or earlier for interval cancers. The others were normal. Original films were read by fifteen experienced screening radiologists. The readers annotated potential abnormalities and estimated their likelihood of malignancy. More than 1 year later, five radiologists reread a subset of 271 cases (88 cancer cases having visible signs in retrospect and 183 normals) on a mammography workstation after film digitization. Markers from a computer-aided detection (CAD) system for microcalcifications were available to the readers. Performance was evaluated by comparison of A(z)-scores based on ROC and multiple-Reader multiple-case (MRMC) analysis, and localized receiver operating characteristic (LROC) analysis for the 271 cases. Reading speed was also determined. No significant difference in diagnostic performance was observed between conventional and soft-copy reading. Average A(z)-scores were 0.83 and 0.84 respectively. Soft-copy reading was only slightly slower than conventional reading. Using a mammography workstation including CAD for detection of microcalcifications, soft-copy reading is possible without loss of quality or efficiency.

Aged↗

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Humans↗

Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings.

The purpose of this study was to evaluate the performance of a computer-assisted diagnostic (CAD) tool using various reconstruction slice thicknesses (RST). Image data of 20 patients undergoing multislice CT for pulmonary metastasis were reconstructed at 4.0, 2.0 and 0.75 mm RST and assessed by two blinded radiologists (R1 and R2) and CAD. Data were compared against an independent reference standard. Nodule subgroups (diameter >10, 4-10, <4 mm) were assessed separately. Statistical methods were the ROC analysis and Mann-Whitney U test. CAD was outperformed by readers at 4.0 mm (Az = 0.18, 0.62 and 0.69 for CAD, R1 and R2, respectively; P<0.05), comparable at 2.0 mm (Az = 0.57, 0.70 and 0.69 for CAD, R1 and R2, respectively), and superior using 0.75 mm RST (Az = 0.80, 0.70 and 0.70 and sensitivity = 0.74, 0.53 and 0.53 for CAD, R1 and R2, respectively; P<0.05). Reader performances were significantly enhanced by CAD (Az = 0.93 and 0.95 for R1 + CAD and R2 + CAD, respectively, P<0.05). The CAD advantage was best for nodules <10 mm (detection rates = 93.3, 89.9, 47.9 and 47.9% for R1 + CAD, R2 + CAD, R1 and R2, respectively). CAD using 0.75 mm RST outperformed radiologists in nodules below 10 mm in diameter and should be used to replace a second radiologist. CAD is not recommended for 4.0 mm RST.

Adult↗

The identification of bias in studies of the diagnostic performance of imaging modalities.

The demand for evidence-based healthcare is increasing nationally and internationally and it is equally necessary in both diagnostic and therapeutic practice. Evidence may be collected and combined by means of a systematic literature review of published and unpublished data on a well-defined topic. The output of such reviews is then available to guide health policy, influence good practice or direct research. Published guidelines are available on the performance of systematic reviews, especially those of randomized controlled trials. Although there is an extensive literature base of research data in diagnostic imaging there are few such trials, but it is still possible to perform systematic reviews. With the alternative study designs encountered it is important to be aware of the main threats to study validity. In this paper the biases likely to be encountered in studies of diagnostic performance are reviewed, with particular reference to diagnostic imaging tests. The biases are sub-divided into three categories. The first category is patient selection and covers the validity of generalizing results beyond the study population. The other two, concerning study design and execution and the interpretation of results, affect the likely validity of the results of a study. An understanding of these factors is an essential prerequisite for those undertaking or using a systematic literature review in the field of diagnostic imaging. The definitions form the foundations of a defensible review protocol.

Bias↗

ROC analysis of diagnostic performance utilizing serum antiproteases in cancer patients.

Assessment of the accuracy of diagnostic procedures is made independent of diagnostic criteria by means of a receiver-operating-characteristics (ROC) curve. We performed ROC analysis for the major serum antiproteases: alpha-1-antitrypsin (A1AT) and alpha-2-macroglobulin (A2M), in 99 cancer patients compared with 71 normal individuals. A1AT and A2M were significantly higher in cancer patients (p less than 0.0005). By comparing true positive and false positive rates for different serum levels, ROC analysis showed that serum A1AT quantification seems more useful in clinical practice than serum A2M.

Adult↗

Dynamic contrast-enhanced FMPSPGR of the pancreas: impact on diagnostic performance.

OBJECTIVE: The objective of this study was to evaluate the diagnostic impact of dynamic contrast-enhanced fast multiplanar spoiled gradient-recalled imaging (FMPSPGR) of the pancreas. MATERIALS AND METHODS: MR imaging examinations of the upper abdomen for 101 patients were evaluated retrospectively and compared with histologic and surgical results as well as imaging or laboratory and clinical follow-up results. Standard T1-weighted spin-echo images, T2-weighted fast spin-echo images with fat saturation, and FMPSPGR had been obtained for all patients. Of the 101 patients, 79 also underwent fat-saturated contrast-enhanced T1-weighted spin-echo MR imaging. Qualitative analysis consisted of evaluation of overall image quality and characterization of the pancreas as normal or abnormal, for which receiver operating characteristic curves were calculated. A contrast-to-noise ratio between the pancreas and the surrounding tissue was calculated for each patient. RESULTS: By a statistically significant margin, FMPSPGR performed better than conventional spin-echo MR imaging. For FMPSPGR, sensitivity and specificity were 87% and 100%, respectively, compared with T1-weighted spin-echo sequences (sensitivity, 50%; specificity, 96%), T2-weighted spin-echo sequences with fat saturation (sensitivity, 60%; specificity, 93%), and contrast-enhanced T1-weighted spin-echo sequences with fat saturation (sensitivity, 53%; specificity, 90%). Diagnostic confidence was highest with FMPSPGR. CONCLUSION: FMPSPGR should be used in all MR imaging examinations of the upper abdomen. This technique offers better visualization of important structures and increases confidence for a more specific and accurate diagnosis than does conventional spin-echo imaging.

Contrast Media↗

Diagnostic performance of the bidirectional Doppler velocity curve recorded at the ankle.

The diagnostic value of different parameters derived from the Doppler velocity curve recorded at the ankle was analysed in a population of 432 subjects. To document the presence or absence of obliterative arterial diseases in the lower limbs, systolic blood pressure measurements were made and oscillography before and after exercise was recorded. A descending slope below 20.5 mm as recorded during 0.40 sec, appears as a sensitive indicator of occlusive arterial diseases of the lower extremities: 84% of the limbs were correctly classified showing with a high sensitivity of 91.8% but a lower specificity of 76%. By considering a combination of two parameters (descending slope and crest-time), the overall performance increases up to 88% and specificity becomes satisfactory (85%), while sensitivity is kept at 90%. Quantitative analysis of the Doppler velocity curve recorded at the ankle is feasible and is most helpful in discriminating normal and abnormal limbs both in daily clinical practice and in large scale studies.

Adolescent↗

Diagnostic performance of the thirty-four hour dexamethasone suppression test.

The performance of the dexamethasone suppression test (DST) in the diagnostic confirmation of endogenous depression was compared according to two times of blood collection--1600 hr on day 2 (usual sample) and 0800 hr on day 3 (34 hr after dexamethasone intake)--in 14 endogenous depressives and in a control group of 17 psychiatric inpatients with other diagnoses. For the day 2 (1600 hr) sample, a 5 micrograms/dl cortisol concentration represented the best cut-off score, with sensitivity of 57% specificity of 88%, and diagnostic confidence of 80%. For the day 3 (0800 hr) sample, the best cut-off score was 20 micrograms/dl, with the same sensitivity (57%) but there was a decrease of both specificity (to 76%) and diagnostic confidence (to 67%). The mean cortisol levels were much higher on day 3 than on day 2, suggesting that the inhibitory activity of dexamethasone was no longer present.

Adult↗

Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome.

BACKGROUND: Lung auscultation and bedside chest radiography are routinely used to assess the respiratory condition of ventilated patients with acute respiratory distress syndrome (ARDS). Clinical experience suggests that the diagnostic accuracy of these procedures is poor. METHODS: This prospective study of 32 patients with ARDS and 10 healthy volunteers was performed to compare the diagnostic accuracy of auscultation, bedside chest radiography, and lung ultrasonography with that of thoracic computed tomography. Three pathologic entities were evaluated in 384 lung regions (12 per patient): pleural effusion, alveolar consolidation, and alveolar-interstitial syndrome. RESULTS: Auscultation had a diagnostic accuracy of 61% for pleural effusion, 36% for alveolar consolidation, and 55% for alveolar-interstitial syndrome. Bedside chest radiography had a diagnostic accuracy of 47% for pleural effusion, 75% for alveolar consolidation, and 72% for alveolar-interstitial syndrome. Lung ultrasonography had a diagnostic accuracy of 93% for pleural effusion, 97% for alveolar consolidation, and 95% for alveolar-interstitial syndrome. Lung ultrasonography, in contrast to auscultation and chest radiography, could quantify the extent of lung injury. Interobserver agreement for the ultrasound findings as assessed by the kappa statistic was satisfactory: 0.74, 0.77, and 0.73 for detection of alveolar-interstitial syndrome, alveolar consolidation, and pleural effusion, respectively. CONCLUSIONS: At the bedside, lung ultrasonography is highly sensitive, specific, and reproducible for diagnosing the main lung pathologic entities in patients with ARDS and can be considered an attractive alternative to bedside chest radiography and thoracic computed tomography.

Aged↗

Acute cervical spine trauma: diagnostic performance of single-view versus three-view radiographic screening.

PURPOSE: To compare the diagnostic accuracy of single-view and three-view cervical spine radiographs in acute trauma. MATERIALS AND METHODS: Radiographs of 97 patients with acute cervical spine fractures were matched with those of 92 proved normal cases. Fourteen radiologists, including three senior attending radiologists each with more than 20 years of post-residency experience, four junior attending radiologists each with less than 5 years of practice experience, three senior radiology residents in their 3rd or 4th year of radiology residency, and four junior radiology residents at the end of their 1st year of radiology training, interpreted each case twice: once as a lateral-only study and again as a three-view study. Multireader-multicase receiver operating characteristic analysis was performed. Difficult cases were reviewed for trends in the errors. RESULTS: Eight of 14 readers detected fractures better with the three-view series. Among junior attending radiologists, the differences were statistically significant. Most improvements were in fractures of the dens and fractures and unilateral dislocations of the articular mass. Overall, sensitivity increased from 81.8% to 83.3%. The reliability of fracture classification improved. Less experienced readers performed better with the three-view series. CONCLUSION: A three-view screening radiographic series will allow most readers to detect a few more fractures than a single-view series. The improvements occur primarily in a subset of difficult-to-diagnose injuries.

Acute Disease↗

Diagnostic performance of teleradiology in cervical spine fracture detection.

This study was done to assess the diagnostic accuracy of high-resolution (5 lp/mm) teleradiology for detecting cervical spine fractures. Single radiographs from 25 patients with and 25 patients without cervical spine fractures were transmitted between two units of our teleradiology system (Dupont DTR 2000) located 5 miles apart. Each image was examined by four readers. Fracture detection accuracy was assessed by generating receiver operating characteristic (ROC) curves and comparing the areas under each reader's curves for original and transmitted images. Two readers had statistically significant better fracture detection using nontransmitted images, whereas two had no significant differences in accuracy. The authors conclude that high resolution in and of itself is not adequate for fracture detection, and that issues concerning image contrast manipulation also will have to be addressed before teleradiology systems can be used for clinical cervical spine fracture screening.

Cervical Vertebrae↗

Improved diagnostic performance on the severity of left ventricular hypertrophy with body surface mapping.

To improve the diagnostic usefulness of electrocardiography (ECG) in determining the severity of left ventricular hypertrophy (LVH) with body surface mapping, 87 unipolar ECGs were recorded from 57 patients with left ventricular (LV) concentric hypertrophy and 30 with LV dilatation. Body surface ECG features due to LVH were evaluated by increase of QRS voltage and delayed local activation. We measured for each lead R voltage, net area of QRS (AQRS), ventricular activation time (VAT), and departure index (DI) of AQRS and VAT (DI = mean/SD). From these measurements, seven parameters were calculated for each patient: Rmax, the maximal R wave voltage; AQRSmax, the maximal AQRS; AQRS-Dmax, the maximal AQRS DI; AQRS-Darea, the area size where DIs of AQRS are more than 2; VATmax, the maximal VAT; VAT-Dmax, the maximal VAT DI; and VAT-Darea, the area size where DIs of VAT are more than 2. Among these parameters, the most effective for diagnosis of LVH were selected by stepwise multiple regression analysis. In the concentric hypertrophy group, the combination of VAT-Darea and Rmax was determined to be the best for estimating wall thickness. The regression equation determined from them correlated well to wall thickness (r = 0.73). In the LV dilatation hypertrophy group, only AQRSmax was selected for estimating LV dilatation. A good correlation between AQRSmax and LV internal dimension was observed (r = 0.73). With the body surface distribution of VAT prolongation, septal hypertrophy was separated from the other LVH. These were superior to the conventional method of 12-lead ECGs. ECG diagnosis of LVH severity improved by incorporating a mapping study. Also, prolongation of VAT and increase in QRS voltage were shown to be important when determining the severity of LVH.

Adolescent↗