Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Copying Processes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Health complaints attributed to the use of carbonless copy paper (a preliminary report).

Persistent health complaints attributed to the use of carbonless copy paper by office workers on the campus of the University of Washington led to this preliminary study. The goals were to estimate the extent of the problem in a population of known carbonless copy paper users; to describe those health problems which the users attribute to the use of carbonless copy paper; and to make a preliminary determination of the chemical constituents of the paper. Participants were asked to complete a health questionnaire and to attach to it copies of the forms they used. A minimum estimate of 10.7 health complainants per 100 users was similar to that found by investigators in Denmark, but lower than that reported by other investigators and of anecdotal material reported to the study group. There was a statistically significant association between complainants and the amount of paper used. Reports of headaches and irritation of the skin, eye and respiratory tract were similar to those reported elsewhere. Concurrent factors such as poor ventilation, high temperature and/or low humidity need to be investigated for possible synergistic or additive effects.

Copying Processes↗

A search for discomfort-inducing factors in carbonless copying paper.

Connections between various types of carbonless copying paper and the occurrence of work-related symptoms of the skin and mucous membranes were studied. The analysis started from the exposure factor, i.e., from the carbonless copying papers and not from the exposed persons. In total, 276 paper samples were investigated. One hundred ninety samples were carbonless copying papers for which information was obtained concerning both the handling of the papers and the symptoms occurring among those handling the papers. To distinguish between carbonless copying papers of different makes, gas chromatography of paper extracts was performed, sometimes combined with thin-layer chromatography of the color formers. By coding the paper samples, the analyses of the papers and the interviews of the exposed persons could be performed "blindly." In the carbonless copying paper most frequently associated with complaints, mono-iso-propylbiphenyl (MIPB) was used as solvent for the color formers. It is probable, however, that the symptoms connected to this paper were induced by some component of the paper other than MIPB. A covariation between papers associated with skin symptoms and mucous membrane symptoms was observed. Exposure to carbonless copying papers treated with desensitizing ink (D-ink) covariated statistically with work-related skin irritation. The causative factor was probably two specific D-inks available on the Swedish market at the period of the investigation.

Biphenyl Compounds↗

A novel method for producing x-ray test objects and phantoms.

A novel method for producing customized x-ray test objects and clinically realistic phantoms has been developed. Test objects can be created with a drawing software package and the digital images can be printed on a standard inkjet printer but using potassium iodide solution in place of the cartridge's ink. The reproducibility and the consistency, the limiting spatial resolution, the uniformity as well as the potassium iodide thickness per print have been evaluated. The relationship between the number of prints, grey levels and the radiation contrast was investigated and quantified. A copy of the Leeds TO10 contrast detail test object was printed and the x-ray images of the Leeds TO10 and of the printed Leeds TO10 were compared. In addition, the potential use of this method was demonstrated by reproducing a percutaneous transluminal coronary angioplasty clinical digital image. The reproducibility and consistency of this method was found to be better than 0.1%. The limiting spatial resolution of the printer using ink was found to be 3.55 1p mm(-1) but it deteriorated when the ink was replaced with potassium iodide and as the print density increases. The uniformity across the printed area was found to be satisfactory although an artefact due to the printer was present in the x-ray images. The comparison between the Leeds TO10 and the printed Leeds TO10 gave differences less than 10%. A good agreement between the clinical image and the printed clinical image was found. In conclusion, the method is a reliable, cost-effective, flexible and alternative way for producing x-ray test objects and clinically related phantoms.

Air↗

Calibration of a radioactive ink-based stack phantom and its applications in nuclear medicine.

This paper describes a stack phantom useful for imaging complex activity distributions. It is based on images printed with radioactive ink using a commercial ink-jet printer. The application for the phantom is in the evaluation of planar and SPECT scintillation camera images and for validation of Monte Carlo simulated images. The accuracy in generating the activity distributions on paper sheets is especially important. Here we describe the calibration procedure for the ink-jet printer. The goal of the printer calibration is to find the relationship between the digital image count (voxel grey level) and its corresponding activity on the paper sheets (radioactivity). The relationship between the voxel grey level and the radioactivity on the paper sheets (measured by scanning technique and well counter) was found to be logarithmic, and a 3rd degree polynomial was found to fit the relationship. The distribution of radioactivity in the ink cartridge was investigated by pinhole SPECT. The distribution of (99m)Tc solution was found to be homogeneous in the ink solution. Experimental studies were done directly on Monte Carlo simulated heart images from the NCAT phantom. The result showed that the simulated images are similar to the images measured using the ink-jet technique. This stack phantom could be a promising solution with an advantage that the exact geometry generated in Monte Carlo could be imitated in the phantom. The phantom is a very flexible device and clearly much more versatile than conventional phantoms which have a fixed geometry and spatial limitation.

Calibration↗

Specimen photocopying for surgical pathology reports.

A method of direct photocopying of surgical pathology specimens is described. The copy thus obtained can be included as a part of the surgical pathology report, to visually indicate locations of lesions, margins, measurements, and sites of sections taken for microscopic examination.

Copying Processes↗

Permanent records of microchromatography of hemoglobins.

In the general hematology laboratory, quantitation of hemoglobin A2 by the microchromatographic method is superior to the method of elution from cellulose acetate membranes. A permanent record of microchromatographic patterns for the detection of hemoglobins S and C at birth can be easily obtained by using a photocopying machine and a flat mirror. These copies can be stored for comparison with definitive results when the children are retested at 6 months of age or later.

Chromatography↗

FRAGMAP--a program for restriction site map comparison.

A program is described which aligns pairs of linear restriction site maps using an algorithm which maximizes the number of coincident sites through the addition of extra 'padding' fragments; and makes maps of the non-conserved sites between pairs and triplets of input maps. A range of display facilities, hardcopy functions and database management routines are also included. The program runs on a stand-alone microcomputer, and is stored along with a database of several hundred files on a single floppy disc.

Copying Processes↗

Constructing DNA by polymerase recombination.

Polymerase-mediated recombination based on DNA polymerase chain reactions (PCRs) has been used to carry out directed joining at a present point of two DNA fragments initially contained in a plasmid and a single-stranded synthetic DNA. The process includes copying of these fragments by PCR with generation of an overlapping homologous region. Such overlap of 12 base pairs in length was found to be sufficient to provide further DNA joining also by use of PCR.

Base Sequence↗

Office equipment and supplies: a modern occupational health concern?

The Helsinki Office Environment Study, a population-based cross-sectional study was carried out in Finland in 1991 among 2,678 workers in 41 randomly selected office buildings. The aim was to evaluate the relations between work with office equipment and supplies and the occurrence of eye, nasopharyngeal, skin, and general symptoms (often denoted as sick building syndrome (SBS)), chronic respiratory symptoms, and respiratory infections. Work with self-copying paper was significantly related to weekly work-related eye, nasopharyngeal, and skin symptoms, headache and lethargy, as well as to the occurrence of wheezing, cough, mucus production, sinusitis, and acute bronchitis. Photocopying was related to nasal irritation, and video display terminal work to eye symptoms, headache, and lethargy.

Acute Disease↗