Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Analysis of polar pesticides in water and wine samples by automated in-tube solid-phase microextraction coupled with high-performance liquid chromatography-mass spectrometry.

A simple and sensitive method for the determination of polar pesticides in water and wine samples was developed by coupling automated in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS). To achieve optimum performance, the conditions for both the in-tube SPME and the ESI-MS detection were investigated. In-tube SPME conditions were optimized by selecting the appropriate extraction parameters, especially the stationary phases used for SPME. For the compounds studied, a custom-made polypyrrole (PPY)-coated capillary showed superior extraction efficiency as compared to several commercial capillaries tested, and therefore, it was selected for in-tube SPME. The influence of the ethanol content on the performance of in-tube SPME was also investigated. It was found that the amount of pesticides extracted decreased with the increase of ethanol content in the solutions. The ESI-MS detection conditions were optimized as follows: nebulizer gas, N2 (30 p.s.i.; 1 p.s.i.=6894.76 Pa); drying gas, N2 (10 l/min, 350 degrees C); capillary voltage, 4500 V; ionization mode, positive; mass scan range, 50-350 amu; fragmentor voltage, variable depending on the ions selected. Due to the high extraction efficiency of the PPY coating and the high sensitive mass detection, the detection limits (S/N = 3) of this method for the compounds studied are in the range of 0.01 to 1.2 ng/ml, which are more than one order of magnitude lower than those of the previous in-tube SPME-HPLC-UV method. A linear relationship was obtained for each analyte in the concentration range of 0.5 to 200 ng/ml with MS detection. This method was applied to the analysis of phenylurea and carbamate pesticides in spiked water and wine samples.

Automation↗

Vortex-assisted liquid-liquid microextraction based on natural deep eutectic solvents for the determination of pyrethroid pesticides in urine.

A novel, facile, and environmentally friendly analytical method was developed based on vortex-assisted liquid-liquid microextraction and high-performance liquid chromatography with diode-array detection for detecting pyrethroid pesticides (PPs) in urine. Natural deep eutectic solvents (NADESs) were prepared using plant essential oil-derived monoterpenoids (thymol, carvacrol, and menthol) combined with aromatic primary alcohols (benzyl alcohol, phenethyl alcohol, and phenylpropyl alcohol) as hydrogen bond donors and acceptors. These solvents served as environmentally benign extraction media, thereby avoiding the use of conventional volatile, toxic organic solvents. NADESs are naturally derived, easy to prepare, biodegradable, and environmentally friendly solvents. Hydrophobic and π-π interactions between the NADESs and PPs may contribute to enhancing the affinity of PPs toward the NADESs phase. Vortex technology, accelerating mass transfer between the sample and extractant phases, enables fast extraction of PPs. Under optimized conditions, the method achieved a low detection limit (0.002 mg L-1), satisfactory precision with relative standard deviations (0.3%-2.4%), and acceptable recovery (80.7%-86.2%). The method demonstrated excellent performance in urine analysis and was feasible as a facile and green strategy for monitoring the content of PPs in biological matrices and assessing exposure risk.

Liquid Phase Microextraction↗

Analysis of estrogens in environmental waters using polymer monolith in-polyether ether ketone tube solid-phase microextraction combined with high-performance liquid chromatography.

A simple, rapid and sensitive on-line method for simultaneous determination of four endocrine disruptors (17beta-estradiol, estriol, bisphenol A and 17alpha-ethinylestradiol) in environmental waters was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC) with fluorescence detection (FLD). A poly(acrylamide-vinylpyridine-N,N'-methylene bisacrylamide) monolith, synthesized inside a polyether ether ketone (PEEK) tube, was selected as the extraction medium. To achieve optimum extraction performance, several parameters were investigated, including extraction flow-rate, extraction time, and pH value, inorganic salt and organic solvent content of the sample matrix. By simply filtered with nylon membrane filter and adjusting the pH of samples to 6.0 with phosphoric acid, the sample solution then could be directly injected into the device for extraction. Low detection limits (S/N=3) and quantification limits (S/N=10) of the proposed method were achieved in the range of 0.006-0.10 ng/mL and 0.02-0.35 ng/mL from spiked lake waters, respectively. The calibration curves of four endocrine disruptors showed good linearity ranging from quantification limits to 50 ng/mL with a linear coefficient R(2) value above 0.9913. Good method reproducibility was also found by intra- and inter-day precisions, yielding the RSDs less than 12 and 9.8%, respectively. Finally, the proposed method was successfully applied to the determination of these compounds in several environmental waters.

Benzophenones↗

High pH-resistant, surface-bonded sol-gel titania hybrid organic-inorganic coating for effective on-line hyphenation of capillary microextraction (in-tube solid-phase microextraction) with high-performance liquid chromatography.

Sol-gel titania-poly(dimethylsiloxane) (TiO2-PDMS) coating was developed for capillary microextraction (CME) to perform on-line preconcentration and HPLC analysis of trace impurities in aqueous samples. A method is presented describing in situ preparation of the titania-based sol-gel PDMS coating and its immobilization on the inner surface of a fused silica microextraction capillary. To perform CME-HPLC, the sol-gel TiO2-PDMS capillary was installed in the HPLC injection port as an external sampling loop, and a conventional ODS column was used for the liquid chromatographic separation. The target analytes were extracted on-line by passing the aqueous sample through this sampling loop. The sol-gel titania-PDMS coated capillaries were used for on-line extraction and HPLC analysis of polycyclic aromatic hydrocarbons, ketones, and alkylbenzenes. The extracted analytes were then transferred to the HPLC column using an organic-rich mobile phase followed by HPLC separation via gradient elution. To our knowledge, this is the first report on the use of sol-gel titania-based organic-inorganic material as a sorbent in capillary microextraction. The newly developed sol-gel titania-based CME coatings demonstrated excellent pH stability and enhanced extraction capability over the commercial GC coatings that are conventionally used for the same purpose. Extraction characteristics of a sol-gel titania-PDMS capillary remained practically unchanged after continuous rinsing with a 0.1 M NaOH solution (pH 13) for 12h.

Chromatography, High Pressure Liquid↗

Application of solid-phase microextraction to the recovery of explosives and ignitable liquid residues from forensic specimens.

A current review of the application of solid-phase microextraction (SPME) to the analysis of ignitable liquids and explosive residues is presented along with experimental results demonstrating the relative effects of controllable variables. Variables discussed include fiber chemistry, adsorption and desorption temperatures, extraction and desorption times, fiber sampling placement (direct, headspace, and partial headspace) and matrix effects, including water content. SPME is shown to be an inexpensive, rapid and sensitive method for the analysis of ignitable liquids and high explosives residues from solid debris samples and from aqueous samples. Explosives are readily detected at parts per trillion concentrations and ignitable liquids are reproducibly detected at levels below those using conventional methods.

Chemistry Techniques, Analytical↗

Liquid-liquid-liquid microextraction with automated movement of the acceptor and the donor phase for the extraction of phenoxyacetic acids prior to liquid chromatography detection.

A simple liquid-liquid-liquid microextraction with automated movement of the acceptor and the donor phase (LLLME/AMADP) technique is described for the quantitative determination of five phenoxyacetic acids in water using a disposable and ready to use hollow fiber. The target compounds were extracted from the acidified sample solution (donor phase) into the organic solvent residing in the pores of the hollow fiber and then back extracted into the alkaline solution (acceptor phase) inside the lumen of the hollow fiber. The fiber was held by a conventional 10-microl syringe. The acceptor phase was sandwiched between the plunger and a small volume of the organic solvent (microcap). The acceptor solution was repeatedly moved in and out of the hollow fiber assisted by a programmable syringe pump. This repeated movement provides a fresh acceptor phase to come in-contact with the organic phase and thus enhancing extraction kinetics leading to high enrichment of the analytes. The microcap separates the aqueous acceptor phase and the donor phase in addition of being partially responsible for mass transfer of the analytes from donor solution (moving in and out of the hollow fiber from the open end of the fiber) to the acceptor solution. Separation and quantitative analyses were then performed using liquid chromatography (LC) with ultraviolet (UV) detection at 280 nm. Various parameters affecting the extraction efficiency viz. type of organic solvent used for immobilization in the pores of the hollow fiber, extraction time, stirring speed, effect of sodium chloride, and concentration of donor and acceptor phases were studied. Repeatability (RSD, 3.2-7.4%), correlation coefficient (0.996-0.999), detection limit (0.2-2.8 ng ml(-1)) and enrichment factors (129-240) were also investigated. Relative recovery (87-101%) and absolute recoveries (4.6-13%) have also been calculated. The developed method was applied for the analysis of river water.

Acetates↗

Evaluation of the effects of domestic tomato processing on biopesticide residue using natural deep eutectic solvents (NADES) extractions.

The present study evaluated the fate of fourteen botanical biopesticides in processed tomato samples. Various processing methods were employed, including washing, dehydration, and the preparation of juice and sauce. The extraction was performed using more sustainable techniques, aimed at minimizing the environmental impact of conventional organic solvents by substituting them with natural deep eutectic solvents (NADES). Solid-liquid extraction (SLE) and dispersive liquid-liquid microextraction with solidification of floating organic drop (DLLME-SFOD) were utilized for solid and liquid tomato samples, respectively. The NADES used was choline chloride:2,3-butanediol (ChClBt) at a 1:4 molar ratio for both techniques, resulting in recovery values ranging from 69.2 to 106.2% for SLE, and extraction efficiencies reaching up to 46.2% for DLLME-SFOD. The impact of these processes was evaluated employing the processing factor (PF), yielding PF values of less than 1 in all cases. Compounds as pyrethrins, azadirachtin, and rotenone persisted after processing, posing a potential consumer risk.

Solanum lycopersicum↗

Determination of telmisartan in rat tissues by in-tube solid-phase microextraction coupled to high performance liquid chromatography.

A poly(methacrylic acid-ethylene glycol dimethacrylate, MAA-EGDMA) monolithic capillary was used for the direct and on-line extraction of telmisartan from Sprague-Dawley rat tissue (heart, kidney, and liver) homogenates. Under optimized conditions, the tissue homogenates were simply diluted with a mixture of phosphate buffer (pH 2)/ACN (90:8 v/v), and then injected for extraction only after centrifugation and filtration. Coupled to HPLC with fluorescence detection, the method was linear over the range of 1.25-1500 ng/g for telmisartan in heart and kidney, 12.5-15 000 ng/g in liver with correlation coefficients over 0.9992. The detection limits were found to be in the range from 0.24 to 1.8 ng/g. RSDs for intra- and inter-day ranged from 1.2 to 8.1%. The determination of telmisartan in treated rat tissues was achieved by using the proposed method.

Angiotensin II Type 1 Receptor Blockers↗

Electrochemical preparation of composite polyaniline coating and its application in the determination of bisphenol A, 4-n-nonylphenol, 4-tert-octylphenol using direct solid phase microextraction coupled with high performance liquid chromatography.

For SPME-HPLC, metal wires with better mechanical strength are preferred over the fused silica fibers. In this article, a novel composite polyaniline (CPANI) doped with PEG and polydimethylsiloxane coating (CPANI fiber) was prepared on a stainless steel wire by a three-electrode system: the fiber was used as the work electrode, a calomel electrode and a platinum electrode were used as the reference and the counter electrodes, respectively. To evaluate the new CPANI coating, the coating was used to extract three kinds of phenols (bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol) in water samples by direct-SPME mode and then desorbed in commercial SPME-HPLC interface to separation. The extraction procedure was also optimized. Five real water samples were investigated. Good recoveries were gained when environmental samples were analyzed.

Aniline Compounds↗

Determination of delorazepam in urine by solid-phase microextraction coupled to high performance liquid chromatography.

An SPME-HPLC-UV method for the determination of delorazepam, a representative benzodiazepine, in spiked human urine samples was developed for the first time. The performances of two commercially available fibers, a carbowax/templated resin (Carbowax/TPR-100) and a polydimethylsiloxane/divinylbenzene (PDMS/DVB), were compared, indicating the latter as the most suitable for urine samples analysis. All the aspects influencing adsorption (extraction time, pH, temperature, salt addition) and desorption (desorption and injection time, desorption solvent mixture composition) of the analyte on the fiber have been investigated. In particular, short extraction times were necessary to reach the equilibrium and very short desorption times were employed. The procedure required simple sample pre-treatment and was able to detect 5 ng/ml in spiked urine, regardless of the complexity of the matrix.

Anti-Anxiety Agents↗

Optimisation of solid-phase microextraction coupled to HPLC-UV for the determination of organochlorine pesticides and their metabolites in environmental liquid samples.

A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-mum polydimethylsiloxane-divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-mum PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.

Chromatography, High Pressure Liquid↗

Application of solid-phase microextraction combined with derivatization to the determination of amphetamines by liquid chromatography.

This work evaluates the utility of solid-phase microextraction (SPME) in the analysis of amphetamines by liquid chromatography (LC) after chemical derivatization of the analytes. Two approaches have been tested and compared, SPME followed by on-fiber derivatization of the extracted amphetamines, and solution derivatization followed by SPME of the derivatives formed. Both methods have been applied to measure amphetamine (AP), methamphetamine (MA), and 3,4-methylenedioxymethamphetamine (MDMA), using the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) and carbowax-templated resin (CW-TR)-coated fibers. Data on the application of the proposed methods for the analysis of different kind of samples are presented. When analyzing aqueous solutions of the analytes, both approaches gave similar analytical performance, but the sensitivity attainable with the solution derivatization/SPME method was better. The efficiencies observed when processing spiked urine samples by the SPME/on-fiber derivatization approach were very low. This was because the extraction of matrix components into the fiber coating prevented the extraction of the reagent. In contrast, the efficiencies obtained for spiked urine samples by the solution derivatization/SPME approach were similar to those obtained for aqueous samples. Therefore, the later method would be the method of choice for the quantification of amphetamines in urine.

Amphetamines↗

Optimization of solid-phase microextraction procedures for the determination of tricyclic antidepressants and anticonvulsants in plasma samples by liquid chromatography.

Simple, sensitive, and reproducible off-line solid-phase microextraction and liquid chromatography (SPME/LC) methods are described for the determination of seven anticonvulsants and tricyclic antidepressants in human plasma. Factorial design and simplex methodology were applied in the optimization of the SPME procedure for tricyclic antidepressants analyses. Important factors in the SPME efficiency are discussed, such as the fiber coatings (both lab-made and commercial), extraction time, pH, ionic strength, influence of plasma proteins, and desorption conditions. The development of the lab-made fiber coatings, namely, octadecylsilane, aminosilane, and polyurethane, are further described and applied to anticonvulsants analyses. The investigated plasmatic range for the evaluated anticonvulsants, using CW-TPR fiber, were the following: phenylethylmalonamide (3.00-40.0 microg mL(-1)), phenobarbital (5.00-40.0 microg mL(-1)), primidone (3.00-40.0 microg mL(-1)), carbamazepine and carbamazepine-epoxide (2.00-24.0 microg mL(-1)), phenytoin (2.00-40.0 microg mL(-1)), and lamotrigine (0.50-12.0 microg mL(-1)). The antidepressants' linear plasmatic concentration ranged from 75.0 to 500 ng mL(-1) for imipramine, amitriptyline, and desipramine, and from 50.0 to 500 ng mL(-1) for nortriptyline, being in all cases, the limit of quantification represented by the lowest value. The precision (interassays) for all investigated drugs in plasma sample spiked with different concentrations of each analyte and submitted to the described procedures were lower than 15%. The off-line SPME/LC methodologies developed allow anticonvulsants and antidepressants analyses from therapeutic to toxic levels for therapeutic drug monitoring.

Amitriptyline↗

Optimization of solid-phase microextraction (SPME) for the recovery of explosives from aqueous and post-explosion debris followed by gas and liquid chromatographic analysis

Solid-phase microextraction (SPME) has been evaluated for the recovery of explosives residues from aqueous samples and real post-explosion solid debris samples and optimized using gas chromatography with an electron capture detector (GC-ECD) and high-performance liquid chromatography with ultraviolet detection (HPLC-UV). A modified SPME/HPLC interface utilizing dual six-port valves allowed for independent optimization of SPME desorption and injection variables that provided improved chromatographic resolution and sensitivity. A unique combination of cyano and octadecyl columns resulted in the complete separation of the 14 explosives in EPA method 8330 mixture using HPLC with good quantitative results. At the optimum SPME conditions, the limits of detection (LOD) were found to be of 5 ng/mL to 16 ng/mL of explosives in water and 10 microg/kg to 40 microg/kg of explosives from soil. The technique has been successfully applied to the analysis of real post-explosion debris and can be adapted for use in the field utilizing portable chromatographic instruments.

Journal Article↗

Direct coupling of microcolumn liquid chromatography with in-tube solid-phase microextraction for the analysis of antidepressant drugs.

The direct coupling of in-tube solid-phase microextraction (in-tube SPME) with microcolumn liquid chromatography (micro-LC) has been investigated for the analysis of antidepressants in human urine. The use of in-tube SPME has been clearly shown to be advantageous for the on-line coupling of the SPME method, as the sample pretreatment technique, with micro-LC as the separation technique. This is because much smaller amounts of the sample solutions, desorption solvents and the mobile phase are required compared with conventional SPME-LC systems. The parameters for preconcentration have been investigated for the extraction capillary with the newly developed 'wire-in-tube' configuration.

Antidepressive Agents↗

Matrix solid-phase dispersion microextraction and determination by high-performance liquid chromatography with UV detection of pesticide residues in citrus fruit.

A multiresidue method based on matrix solid-phase dispersion (MSPD) microextraction was studied to determine the carbamate, benfuracarb, and urea insecticides, diflubenzuron, flufenoxuron hexaflumuron and hexythiazox, used in control of citrus pests. Optimisation of different parameters, such as the type of solid support for matrix dispersion, elution solvents and the clean-up step were carried out. The method used 0.5 g of orange sample, C8 bonded silica as MSPD sorbent and dichloromethane as eluting solvent. Recoveries, at spiked concentrations below the maximum residue levels established by Spanish Government, were between 74 and 84% with relative standard deviations ranging from 2 to 4%. The limits of quantification were from 0.15 to 0.25 microgram/g using high-performance liquid chromatography with UV detection at 200 nm. The method may be useful as a screening protocol for the determination of these newly developed pesticides in citrus samples.

Benzamides↗

Evaluating peats for their capacities to remove odorous compounds from liquid swine manure using headspace "solid-phase microextraction".

This paper reports on research designed to investigate the capacities of different highly characterized peats to remove odorous compounds from liquid swine manure (LSM). Peat types representing a wide range of properties were tested in order to establish which chemical and physical properties might be most indicative of their capacities to remediate odors produced by LSM. Eight percent slurries (of peat/LSM) were measured for odor changes after 24 hours using odor panel and GC/MS-Solid-phase microextraction (GC/MS-SPME) analysis. The GC/MS-SPME and odor panel results indicated that, although all peats tested in this study were found to be effective at removing odor-causing compounds found in LSM, some peats tended to work better than others. Overall, the peats that were the most effective at removing odor-causing compounds tended to have lower bulk densities, ash contents, fulvic acids contents, and guaiacyl lignins contents, and higher water holding capacities, hydraulic conductivities, "total other lignins" contents, hydrogen contents, carbon contents, and total cellulose contents. GC/MS-SPME analysis was found to be a reasonably inexpensive and efficient way of conducting this type of research. It allows one to identify a large number of the odor-causing compounds found in LSM, and more importantly, to detect with some precision specific differences in the amounts of these compounds between peat types.

Animals↗

Comparison of solid-phase extraction and solid-phase microextraction for carbofuran in water analyzed by high-performance liquid chromatography-photodiode-array detection.

In this study a direct solid-phase microextraction (SPME) procedure has been developed for the determination of carbofuran in water. Experimental parameters such as selection of SPME coating, effect of temperature, effect of salt addition and solvent desorption were studied and optimized. Analytical parameters such as linearity, precision, detection and quantitation limits, and matrix effects for solid-phase extraction (SPE) and SPME methods were evaluated for comparison purposes with the aim of selecting the most appropriate depending on the detection capabilities required. SPE and SPME were followed by high-performance liquid chromatography with diode-array detection, using a 50 x 4.6 mm I.D. guard column and a 150 x 4.6 mm I.D. analytical column, both packed with C18 silica. Both methods can be applied to real samples and give the same results, but SPE allows the detection of lower carbofuran concentrations (0.06 microg/L) as compared to

Carbofuran↗