Search PubMedSearch

SEARCH · Search PubMed

Search Search PubMed

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

10 recordsLinked to original sources

Effects of Esketamine on Postoperative Hospital Anxiety and Depression Scale Scores in Patients Undergoing Laparoscopic Radical Resection for Colorectal Cancer.

OBJECTIVE: To investigate the effects of intravenous esketamine on postoperative Hospital Anxiety and Depression Scale (HADS) scores in patients undergoing laparoscopic radical resection for colorectal cancer. METHODS: In this prospective, randomized, placebo-controlled study, adult patients for elective laparoscopic radical resection were randomly assigned (1:1) to a control group (group C) or an esketamine group (group PE). Group C received conventional general anesthesia and patient-controlled intravenous analgesia (PCIA). In group PE, esketamine 0.5&#x2009;mg/kg was injected during induction of anesthesia, with esketamine 1&#x2009;mg/kg added to PCIA. Primary outcome was HADS score on postoperative day 1. Secondary outcomes included HADS scores on postoperative days 3 and 7, sleep quality scores, postoperative level of consciousness, complication rate, length of hospital stay, 24&#x2009;h inflammatory factors, and satisfaction scores. RESULTS: Group PE showed significantly lower HADS-A and HADS-D scores on postoperative days 1 and 3 , reduced 24&#x2009;h interleukin-6 (IL-6) leveland higher patient satisfaction compared with group C (all p&#x2009;<&#x2009;0.05). CONCLUSIONS: Esketamine given during induction and in PCIA reduced early-stage postoperative HADS scores and improved patient satisfaction in colorectal cancer patients.

Humans

Esketamine vs. sufentanil for quality of recovery after outpatient gynecological surgery: a randomized clinical trial.

BACKGROUND: Perioperative administration of esketamine has been reported to improve early quality of recovery (QoR). However, data on its effects in outpatient surgery are limited. This study aimed to assess the impact of esketamine on QoR in patients undergoing outpatient gynecological procedures. METHODS: In this investigator-initiated, double-blind, randomized clinical trial, patients aged 18-65&#x2009;years scheduled for outpatient gynecological surgery under sedation were allocated to receive esketamine (0.2&#x2009;mg/kg) or sufentanil (0.1&#x2009;&#x3bc;g/kg) combined with propofol (1.5-3&#x2009;mg/kg). The primary outcome was quality of recovery on postoperative day (POD) 1. Secondary outcomes included quality of recovery on POD2, sedation success rate, length of post-anesthesia care unit (PACU) stay, injection pain, postoperative pain, nausea and vomiting, fatigue, patient and clinician satisfaction, sleep quality, and anxiety and depression. RESULTS: A total of 126 patients were randomized, with 63 assigned to the esketamine group and 63 to the sufentanil group. Of these, 125 patients were included in the final analysis (62 in the esketamine group and 63 in the sufentanil group), as one patient lacked follow-up data. The mean (SD) QoR-15 score on POD1 was 137.9 (14.5) in the esketamine group and 137.8 (10.7) in the sufentanil group, with no significant difference between groups (absolute difference, 0.2; 95% CI, -4.2 to 4.6; p&#x2009;=&#x2009;0.93). For secondary outcomes, the esketamine group had a longer PACU stay (median, 28.0 vs. 23.0&#x2009;min; p&#x2009;<&#x2009;0.001), a lower incidence of severe injection pain (22.6% vs. 50.8%; p&#x2009;=&#x2009;0.002), a higher proportion of patients with pain scores &#x2265; 4 at 30&#x2009;min postoperatively (30.6% vs. 6.3%; p&#x2009;=&#x2009;0.001), and higher fatigue scores (median, 3.0 vs. 2.0; p&#x2009;=&#x2009;0.01). Other secondary outcomes did not differ significantly between groups. CONCLUSION: Among patients undergoing sedation for outpatient gynecological procedures, esketamine did not significantly improve quality of recovery on POD1 compared to sufentanil. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR2500098466.

Humans

Efficacy and safety of rib-guided percutaneous thoracic sympathetic radiofrequency thermocoagulation at two different targets for primary palmar hyperhidrosis: a randomized controlled trial.

OBJECTIVES: To compare the efficacy and safety of computed tomography-guided percutaneous thoracic sympathetic radiofrequency thermocoagulation (RFT) targeting the upper versus lateral margin of the fourth rib head for severe primary palmar hyperhidrosis (PPH). METHODS: Patients with severe PPH were randomly divided into Group U (upper margin target) and Group L (lateral margin target). Outcome measures included 1-year recurrence rate, Hyperhidrosis Disease Severity Scale (HDSS), Dermatology Life Quality Index (DLQI), palm skin temperature, finger perfusion index (PI), compensatory hyperhidrosis and patient satisfaction. RESULTS: Both groups (n&#x2009;=&#x2009;55 each, 110 sides) successfully underwent RFT. No preprocedural PI differences were found (p&#x2009;>&#x2009;0.05). Immediately post-RFT, PI in Group L was significantly higher than in Group U (left p&#x2009;=&#x2009;0.025, right p&#x2009;=&#x2009;0.013). No significant differences in HDSS grades were observed between groups before and at 1&#x2009;day, 2&#x2009;weeks, 1&#x2009;month and 3&#x2009;months post-procedure. However, at 6 and 12&#x2009;months, Group L showed significantly lower HDSS grades (left p&#x2009;=&#x2009;0.033 and 0.016; right p&#x2009;=&#x2009;0.039 and 0.025) and lower DLQI scores (p&#x2009;=&#x2009;0.037 and 0.024) than Group U. Patient satisfaction did not differ within 6&#x2009;months, but Group L had significantly higher satisfaction at 12&#x2009;months (p&#x2009;=&#x2009;0.036). CONCLUSIONS: Targeting the lateral margin of the fourth rib head for RFT achieved greater efficacy, better quality of life and higher patient satisfaction compared to the upper margin target.

Humans

Diagnostic communication in functional neurological disorder: A systematic review and meta-analysis of patient acceptance and clinical outcomes.

OBJECTIVES: Diagnostic disclosure is a key therapeutic moment in Functional Neurological Disorder (FND). This systematic review aimed to evaluate quantitative evidence on diagnostic acceptance, understanding, satisfaction, symptom outcomes, and healthcare utilisation following diagnostic disclosure in FND, and to conduct a meta-analysis of diagnostic acceptance. METHODS: Systematic searches of PubMed, Scopus, PsycINFO, and Web of Science identified quantitative studies in adults with FND. Screening followed predefined inclusion criteria. Data were extracted using a structured template and risk of bias was assessed using the Newcastle-Ottawa Scale. A random-effects meta-analysis of proportions was conducted using the Freeman-Tukey transformation. RESULTS: Fifteen studies were included, four of which contributed to the meta-analysis (n&#x202f;=&#x202f;481). Reported diagnostic acceptance rates ranged from 38.7% to 90%, although the timing and method of assessment varied across studies. Pooled acceptance was 0.68 (95% CI 0.44-0.88), with substantial heterogeneity. Structured or reinforced communication was frequently associated with improved understanding and satisfaction, although its superiority for diagnostic acceptance was not established. In some studies, diagnostic acceptance was associated with more favourable clinical outcomes, although findings were inconsistent. Some studies reported reductions in healthcare utilisation or costs following satisfactory diagnostic explanation, whereas others found no sustained overall reduction. CONCLUSIONS: Diagnostic communication in FND is associated with differences in acceptance, understanding, and downstream clinical and healthcare outcomes. Approximately two-thirds of patients were reported as accepting the diagnosis following disclosure, although the timing and method of assessment varied substantially across studies. Empathic and evidence-informed communication may enhance understanding and engagement, although its effects on healthcare use and recovery remain uncertain. PRACTICE IMPLICATIONS: Diagnostic disclosure should be delivered clearly, empathically, and with reinforcement over time. Written information, reputable educational resources, and opportunities for follow-up clarification may support patient understanding and engagement, although stronger comparative evidence is needed.

Humans

Digital healthcare solutions in preoperative care: A systematic review.

OBJECTIVE: Active participation in preoperative anesthesia preparation is crucial to ensure safe and efficient care. Compliance with preoperative instructions improves clinical outcomes, enhances patient satisfaction and optimizes use of healthcare resources. As digital communication becomes increasingly integrated into healthcare, interactive digital tools such as smartphone applications and Short Message Service (SMS) reminders may offer a valuable means of engaging patients in their own care. In this review, we evaluated the role of digital tools in guiding patients during their preoperative care pathway for anesthesia. METHODS: Following registration (CRD420250655119), we conducted a systematic review of studies evaluating the use of smartphone applications or SMS reminders designed to support preoperative preparation for anesthesia or procedural sedation in adult patients undergoing elective procedures. The primary outcome was compliance with preoperative instructions. Secondary outcomes included rate of late cancellations, patient satisfaction and cost-effectiveness. Studies were eligible if they reported at least one of these outcomes. RESULTS: Ten studies (1 RCT and 9 observational studies), including 11501 participants, were identified. Compliance with preoperative instructions was assessed in 8 studies, most of which reported higher compliance in patients receiving digital interventions across multiple instruction domains, although statistical significance was not consistently observed. Evidence suggested a beneficial effect on reducing late cancellations and improving patient satisfaction. However, results varied across study designs, and data on cost-effectiveness were limited. CONCLUSIONS: Digital tools for preoperative anesthesia guidance were associated with higher compliance and showed potential reduction of late cancellations and increase of patient satisfaction. However, the current evidence is predominantly observational and heterogeneous, limiting the strength of conclusions. PRACTICAL IMPLICATIONS: With healthcare systems under pressure, digital technologies may offer a scalable and patient-centered care solution to support preoperative anesthesia preparation. Nonetheless, further high-quality research is needed to evaluate their long-term clinical, economic and equity implications.

Humans

Ultrasound-Guided Microwave Ablation Versus Open Surgery for Benign Breast Disease: Impact on Postoperative Lactation.

BACKGROUND: Benign breast disease (BBD) is common in adult women. While ultrasound-guided microwave ablation (MWA) is an established minimally invasive treatment, its comparative impact on postoperative lactation, particularly mastitis, remains understudied. This study aimed to evaluate mastitis outcomes following MWA versus open surgery for BBD. METHODS: In this retrospective study, 79 patients (105 nodules) treated between January 2018 and August 2023 were included 41 patients (62 nodules) underwent MWA and 38 patients (43 nodules) underwent open surgery. All patients lactated within 5 years post-procedure. The primary outcome was the incidence of lactational mastitis without systemic symptoms (MWoSS) and mastitis with systemic symptoms (MSS). Patient satisfaction was also assessed. RESULTS: The incidence of MWoSS was significantly lower in the MWA group (19.5%) than in the open surgery group (50.0%). Similarly, MSS occurred in 4.9% of the MWA group versus 34.2% of the open surgery group. Multivariate analysis identified open surgery as an independent risk factor, associated with a 4.13-fold increased risk of MWoSS (OR = 4.125, 95% CI: 1.517-11.218) and a 10.14-fold increased risk of MSS (OR = 10.140, 95% CI: 2.107-48.793). Patient satisfaction was significantly higher in the MWA group (9.29 &#xb1; 0.72 vs. 8.15 &#xb1; 1.13, p < 0.001). CONCLUSION: Compared to open surgery, ultrasound-guided MWA for BBD is associated with a significantly lower risk of postoperative mastitis and higher patient satisfaction, supporting its use for women of reproductive age, particularly when future breastfeeding is planned.

Humans

Evidence-based insights into medial pedicle reduction mammaplasty: A systematic review and meta-analysis.

BACKGROUND: Breast reduction relieves the physical and psychosocial burden of macromastia. Medial pedicle reduction mammaplasty may enhance vascular reliability, preserve nipple-areola complex (NAC) sensation, and sustain upper pole fullness, even in large-volume reductions. The purpose of this study was to assess the outcomes of medial pedicle breast reduction. METHODS: A search across ScienceDirect, Cochrane, and PubMed was conducted. Included studies reported on perioperative outcomes and complications of medial pedicle breast reduction. Data on demographics, surgical variables, complications, sensory recovery, volumetric changes, and patient satisfaction were extracted. Proportion meta-analysis was performed, and odds ratios were calculated for comparison with inferior pedicle breast reduction. RESULTS: Twenty-five studies comprising 1033 patients met the inclusion criteria. Mean BMI ranged from 27 to 42&#xa0;kg/m2, with mean resection weights between 412 and 3828&#xa0;g. Mean surgical times ranged from 104 to 204&#xa0;min. Pooled complication rates were low: infection 1%, seroma 1%, hematoma 1%, fat necrosis 2%, NAC necrosis 1%, dehiscence 8%, and reintervention 5%. Odds of complications did not differ significantly from inferior pedicle reductions. NAC sensation typically recovered by 6-12 months, with no long-term deficits. Volumetric analyses demonstrated stable breast shape after the first postoperative year, with superior upper pole tissue maintained. Patient satisfaction ranged 75-100%, with higher ratings for scar appearance and overall aesthetics in medial pedicle reductions. CONCLUSION: Medial pedicle breast reduction is a well-established and reproducible technique, preserving NAC sensation, achieving stable long-term shape, and enhancing upper pole fullness. It offers satisfactory aesthetic outcomes compared to other traditional methods, even in large-volume reductions.

Humans

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Analgesic effect of premixed nitrous oxide in postoperative rehabilitation for ankle fractures: a randomized controlled trial.

INTRODUCTION: The global incidence of ankle fractures is on the rise, effective postoperative rehabilitation is a crucial aspect of surgical management. However, the occurrence of severe pain during the rehabilitation continues to pose a substantial clinical challenge. METHODS: The study utilizes a dual-arm, single-center, double-blind, randomized controlled trial design. A total of 100 participants were enrolled. Participants included patients experiencing acute pain (self-reported pain score &#x2265;4) who underwent postoperative rehabilitation for ankle fractures. Participants undergoing rehabilitation training were randomized to receive either 65% nitrous oxide or 100% oxygen. The primary outcome measured was the pain score, while secondary outcomes encompassed anxiety scores, physiological indices, side effects, patient and therapist satisfaction, acceptance, and residual pain. RESULTS: Pain scores were found to be significantly lower in the nitrous oxide group than in the oxygen group (T1: median difference -3.0, [95% CI -3.4 to -2.6]; p&#x2009;<&#x2009;0.001; T2: median difference -2.0, [95% CI -2.8 to -1.2]; p&#x2009;<&#x2009;0.001). Compared with the oxygen group, both therapists (p&#x2009;<&#x2009;0.001) and participants (p&#x2009;<&#x2009;0.001) in the nitrous oxide group reported significantly higher satisfaction levels. Acceptance rate showed significant intergroup differences (p&#x2009;<&#x2009;0.001). No severe adverse effects were observed in either group. Anxiety scores between the two groups did not show a significant difference (p&#x2009;=&#x2009;0.31, &#x3b7;2 = 0.027). CONCLUSION: The safety and analgesic profile of nitrous oxide renders it a suitable option for pain management in postoperative ankle fractures rehabilitation, thus providing a safe and easily manageable alternative to the current available strategies. CLINICAL TRIAL REGISTRATION: We have registered at https://www.chictr.org.cn and the registration number is: ChiCTR2400089379.

Humans