Search PubMedSearch

SEARCH · Search PubMed

Search Search PubMed

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

4 recordsLinked to original sources

Ageing effects on chemical, physical, mechanical, and morphological properties of clear aligners - a systematic review.

BACKGROUND: Clear aligner (CA) therapy has experienced rapid use over the past two decades to treat orthodontic malocclusions. However, evidence on CA material degradation in the oral environment remains limited and often focuses on single brands or isolated material properties. OBJECTIVES: To investigate CA ageing characteristics across different materials and brands and evaluate the chemical, physical, mechanical, and morphological changes following simulated or intraoral ageing. SEARCH METHODS: Five databases (PubMed, Web of Science, MEDLINE [Ovid], ProQuest, and Scopus) were searched to 18 March 2026, with no restrictions. ELIGIBILITY CRITERIA: Studies assessing CA properties after intraoral use or simulated ageing (thermocycling, cyclic loading, or liquid immersion) were included. DATA COLLECTION AND ANALYSIS: Study selection followed PRISMA 2020. RoB was assessed using QUIN for purely in vitro studies, JBI for cohort in vivo studies, and Cochrane RoB 2 for RCTs. Results were synthesised narratively and organised by property domain, as substantial methodological heterogeneity precluded formal meta-analysis. Where protocols were comparable, a simple pooled weighted mean was calculated and presented graphically. RESULTS: Ninety-five studies were included. RoB was low in eight studies, moderate in sixty-two, and high in twenty-five. Chemical composition remained largely stable during ageing, though some brands showed trace elemental release. Physical, mechanical, and morphological properties showed material-dependent deterioration. Pooled discolouration was greatest with coffee (weighted mean ΔE = 70.9), versus tea (ΔE = 18.4) and red wine (ΔE = 11.5), with Invisalign® consistently exceeding the clinically perceptible threshold. Force decay of 40-90% typically occurred within 48 h. Thermoplastic polyurethane (TPU)-based and directly printed aligners (DPAs) generally showed greater susceptibility than polyethylene terephthalate glycol-modified (PETG)-based aligners, though findings on hardness, roughness, and stiffness were inconsistent. CONCLUSIONS: CA materials undergo clinically relevant degradation during use, particularly in TPU-based and DPAs aligners. Clinicians may need to prioritise material-specific protocols, reinforce dietary and cleaning instructions, and consider force decay when determining aligner replacement intervals. PROSPERO number: CRD420251110248.

Humans

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n = 50) of articles showed low risk-of-bias, while 7.4% (n = 4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Transforming Curcuma longa leaf waste into cellulose scaffolds.

The constant dearth of transplantable tissues and organs in India required the development of substitute biomaterials for tissue engineering. Plant-based decellularized scaffolds have become attractive options because of their abundance, ethical acceptability, architectural diversity, and lower risks of zoonotic transmission. Curcuma longa leaves were investigated in this study as a possible source of cellulose-based scaffolding for use in biomedical applications. After cuticle removal, an immersion decellularization technique utilizing sodium dodecyl sulphate (SDS) and triton-X-100 was developed to successfully remove cellular and nuclear material while maintaining leaf parenchyma architecture. Histology, DAPI staining, scanning electron microscopy, and a notable decrease in leftover DNA content all demonstrated efficient decellularization. When contrasted with native leaves, the resultant decellularized C. longa leaf scaffolds showed significant increase in porosity, water vapor transmission rate and swelling percent, and significantly lower contact angle with an optimum surface roughness promoting cell adhesion. Mechanical test manifest higher tensile strength with decreased stiffness. Fourier transform infrared spectra of leaf scaffold reveals persistence of different components except cuticle but the intensity of different peaks was decreased. The leaf scaffolds showed superior hemocompatibility and excellent compatibility with Madin-Darby canine kidney cells (MDCK) which is demonstrated by cell attachment and proliferation. MTT assay of seeded scaffold showed significantly higher metabolically active cell. In vivo subcutaneous implantation of decellularized scaffolds showed host tissue incorporation, accumulation of collagen, and neovascularization. C. longa leaf scaffolds can be utilized as cost effective and sustainable biomaterials for soft tissue engineering and regenerative medicine.

Curcuma

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans